Boeing 737-732
Service difficulty reports · 221
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737732' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737732' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2022042502861Battery · missing(LOG 8577603) DURING INSPECTION FOUND 2EA. EMERGENCY LIGHT BATTERIES MISSING. INSTALLED 2EA. EMERGENCY LIGHT BATTERIES IAW B737 AMM 33-51-06-960-805.SDR DALA2020092403160Battery · inoperativeDURING INSPECTION FOUND LEFT SIDE OVER WING EMERGENCY AND AFT GALLEY EMERGENCY SIGNS INOPERATIVE. R& R BATTERIES, PER B737 AMM 33-51. OPS CK NORMAL.SDR DALA2020081602799Battery Pack · inoperativeEMERGENCY LIGHT PACK ASSY M2335 FAILED OPS TEST. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK M2335 IAW B737 AMM 33-51. OPS TESTS GOOD.SDR DALA2020081402788Battery Pack · inoperativeDURING INSPECTION FOUND LH WING EMERGENCY EXIT DOOR EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY IAW B737 AMM 33-51. OPS CHECK NORMAL.SDR DALA2020081302785Battery Pack · inoperativeDURING INSPECTION FOUND MULTIPLE AISLE AND CEILING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M1670 PER B737 AMM 33-51. OPS CHECKS GOOD.SDR DALA2020081002749Battery Pack · inoperativeLEFT WING EMERGENCY EXIT LIGHTS FAILED FUNCTIONAL CHECK. REMOVED AND REPLACED LT WING EMERGENCY EXIT BATTERY PACK IAW AMM 33-51-06. OPS TESTED GOOD.SDR DALA2020072072612Battery Pack · no testDURING INSPECTION FOUND EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED 3 BATTERY PACKS AT LOCATIONS 11/12 A, AFT GALLEY IN CEILING PANEL PER B737 AMM 33-51. OPS CHECKS OK.SDR DALA2020062502509Battery Pack · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHTS INOPERATIVE AT RT OVERWING WINDOW AND SEATS 10-14 RT. R & R BATTERIES FOR RT OVERWING ESCAPE WINDOW AND SEATS 10-14 RT IAW AMM 33-51. OPS CHECKED GOOD.SDR DALA2020061852474Battery Pack · inoperativeDURING INSPECTION, FOUND MULTIPLE EMERGENCY LIGHTS IN FWD GALLEY INOPERATIVE. R/R BATTERY PACK @ LOC M1675. OPS CHK GOOD.SDR DALA2020061852476Lamp · inoperative(LOG 6898894) DURING INSPECTION FOUND ENTRY DOOR 2 L EXTERIOR EMERGENCY LIGHT INOPERATIVE. RELAMPED PER B737 AMM 33-51. RELAMPED PER B737 AMM 33-51.SDR DALA2020060802456Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY SEAT AISLE LIGHTS INOPERATIVE AT SEATS 10D-14D. R+R EMERGENCY BATTERY PACK FOR SEATS 10D-14D IAW AMM 33-51. OPS CHK GOOD.SDR DALA2020051802408Compressor Blade · damagedA/C 3603 - IFSD/ATB - RETURNED TO ATL AND DECLARED AN EMERGENCY DUE TO NUMBER 2 ENGINE FAILURE. FLIGHT CREW PERFORMED QRH AND SHUT DOWN THE ENGINE. CORRECTIVE ACTION: INSPECTION FOUND DAMAGE TO 8TH STAGE HPC BLADES. REPLACED #2 ENGINE REFER TO LOG PAGE 1558574SDR DALA2020051302386Battery Pack · dischargedEMERGENCY LIGHT BATTERY M1169 IS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2020042702304Battery Pack · discharged(LOG 7127575) DURING SVC CHECK FOUND EMERGENCY LIGHTS INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY PACK M1675 PER B737 AMM 33-51.SDR DALA2020032702056Battery Pack · discharged(LOG 7008966) LEFT OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED LEFT OVERWING EXIT LIGHT BATTERY PACK PER B737 AMM 33-51. OPS CHECK GOOD.SDR DALA2020032702057Light · broken(LOG 1538807) EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. REMOVED AND REPLACED BROKEN L2 EMERGENCY EXIT LIGHT ASSY WITH NEW PER B737 AMM 33-51. OPS CHECK GOOD.SDR DALA2020012400569Engine · failedSHIP 3603 - ATO -DURING TAKEOFF ROLL THE RIGHT ENGINE STALLED AND FLAMES WERE REPORTED FROM TAILPIPE. CREW ABORTED TAKEOFF AND SHUTDOWN THE RIGHT ENGINE. CORRECTIVE ACTION: BOROSCOPE INSPECTION REVEALED HPC DAMAGE. MAINTENANCE REPLACED THE RIGHT ENGINE, AIRCRASDR DALA2019122087458Splice Plate · wrong part(LOG 1406964) DURING INSPECTION FOUND INCORRECT SPLICE PLATE WERE INSTALLED DURING ACCOMPLISHMENT OF W/C 5331-01257-05 (PREVENTIVE MOD FOR STA 540 BULKHEAD CHORD). PREVENTIVE MOD REPLACEMENT SPLICE PLATE BS540 BTW STR22R TO STR 23R AS PER ERA 577028-14AD REV BSDR DALA2019122087457Splice Plate · wrong part(LOG 1406953) DURING INSPECTION FOUND INCORRECT SPLICE PLATE WERE INSTALLED DURING ACCOMPLISHMENT W/C 5331-01257-03 (PREVENTIVE MOD FOR STA 540 BULKHEAD CHORD). PERFORMED PREVENTIVE MOD REPLACEMENT SPLICE PLATE BS.540 BTW STR22L TO STR23L AS PER ERA 577028-14ASDR DALA2019112706965Bulkhead Web · cracked(LOG 1377182) DURING INSPECTION FOUND CRACK IN CENTER WING REAR SPAR VAPOR WEB ON RBL 40.00. REPAIRED CRACK REF B737 SRM 57-10-10 REPAIR 4.SDR DALA2019111906769Socket · damaged(LOG 6559717) DURING INSPECTION FOUND OVERHEAD AISLE EXIT LGTS BETWEEN ROW 19-22 ABC INOPERATIVE. T/S & REPLACED LIGHT SOCKET AT 19ABC AND REPLACED BATTERY PACK M1670 PER B737 WDM 33-51. OPS CHECK NORMAL.SDR DALA2019110606446Lens · damaged(LOG 1345765) DURING INSPECTION FOUND THRESHOLD LIGHT LENS / COVER DAMAGED. REPLACED LENS.SDR DALA2019110306439Battery Pack · discharged(LOG 6585871) DURING INSPECTION FOUND FLOOR AISLE EMERGENCY LIGHTRS @ ROWS 18-23 INOPERATIVE. R&R BATTERY PACK AT LOC M1670. CKS GOOD. A/C OK FOR SVC. REF. B737 AMM 33-51.SDR DALA2019103106308Lens · missing(LOG 6576892) DURING INSPECTION FOUND 2R DOOR VERTICAL EMERGENCY EXIT LIGHT LENS MISSING. REPLACED EMERGENCY LIGHT ASSEMBLY AT 2R DOOR. TESTS OK.SDR DALA2019101735955Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY ISLE LIGHTS INOPERATIVE AT ROWS 18-23 RT SIDE. R+R CHARGER AND BATTERY PACK AT LOC M1670. LIGHTS CK OK.SDR DALA2019101735954Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY ISLE LIGHTS INOPERATIVE AT ROWS 24-28 RT SIDE. R+R BATTERY PACK AT LOC M1672. LIGHTS CK OK.SDR DALA2019100325662Oven · odorF/A REPORTS STRONG ODOR FROM OVEN 3 IN AFT GALLEY. R & R AFT NR 2 AND 3 OVEN PER B737 AMM 25-35 OPS CK OK FOR SERVICE.SDR DALA2019092605515Cover · missing(LOG 58896545) DURING INSPECTION FOUND 2L DOOR EXIT SIGN COVER MISSING. INSTALLED COVER. OK FOR SVC.SDR DALA2019090305177Lens · missing(LOG 5658980) DURING INSPECTION FOUND 1 LEFT EMERGENCY EXIT LENS MISSING ON FORWARD GALLEY. REPLACED SAME OK FOR SVC.SDR DALA2019081314744Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY LIGHTS (SEAT MOUNTED) AT SEAT 10-14 INOPERATIVE. REPLACED BATTERY PACK AT 11 L FOR SEATS 10-14 PER B737-700 AMM 33-52. OPS CK GOOD.SDR DALA2019072204333Battery Pack · failed(LOG 5898238) DURING FUNCTIONAL CHECK THE TEST EMERGENCY LIGHT BATTERY PACKS FAILED. R/R BATTERY PACK OF POWER SUPPLY M1669. PER AMM 33-51-06. OPS CKD OK.SDR DALA2019063003990Battery Pack · discharged(LOG 6275858) DURING INSPECTION FOUND EMERGENCY LIGHT CHECK FOUND SEATS 18-23 LIGHTS INOPERATIVE. R&R BATTERY PACK PER AMM 33-51. OPS CHECK GOOD.SDR DALA2019062103732Battery Pack · inoperativeDURING INSPECTION, FOUND LEFT OVERWING EXIT DOOR EMERGENCY LIGHTS INOPERATIVE. REPLACED THE BATTERY M1168 PER B737 AMM 33-51. OP CKS GOOD.SDR DALA2019060433389Battery Pack · inoperativeDURING INSPECTION FOUND R2 DOOR EMERGENCY EXIT LIGHT INOPERATIVE ABOVE DOOR. R/R POWER SUPPLY BATTERY PACK M1672 IAW B37 AMM 33-51. OPS NML.SDR DALA2019052803312Warning System · false activation(LOG 5481304) L/E FLAP TRANSIT ILLUMINATED ON APPROACH WITH FLAPS AT 15 DEGREES. TEST ON FSEU PER FIM 27-51-00 NO CURRENT FAULTS CYCLED FLAPS NUMBEROUS TIMES NO FAULTS NOTED. INSPECTED L/E FLAPS AND PROX SENSORS NO DEFECTS NOTED IAW FIM 27-88.SDR DALA2019051703106Bulkhead · cracked(LOG 5662882) DURING INSPECTION FOUND FOUND TWO CRACKS IN LEFT W/W FWD BULKHEAD JUST FWD OF LT HYD FILTER ASSY. CLEANED AREA, 3" CRACK WAS BROKEN SEALER. REPAIRED 4" CRACK PER SRM 57-10-10 REPAIR 2.SDR DALA2019050302800Battery Pack · discharged(LOG 5656654) DURING INSPECTION FOUND FIRST CLASS & FWD GALLEY EMERGENCY LIGHTS INOPERATIVE. REMOVED & REPLACED BATTERY PACK M1674 PER AMM 33-51. BATTERY PACK M1675 OPS. TEST NML PER AMM 33-51.SDR DALA2019042282540Lens · missingDURING INSPECTION, FOUND CABIN L2 DOOR EXIT SIGN LENSES MISSING. REPLACED L2 DOOR EXIT SIGN LIGHT ASSY PER B737 AMM 33-51.SDR ASMF2019061307Bulkhead Web · damagedDURING OVERNIGHT CHECK, IT WAS DETECTED PRESSURIZATION LEAK IN THE NETWORK AREA OF REAR SPAR VERTICAL PRESSURE STA 663 LBL35 AND RBL35 ON DRAIN VALVE HOUSING BOTH SIDES; MAINTENANCE PERSSONNEL ISSUED THE WO 5367805 TO PERFORM WORKS; THE VALVE HOUSING BOTH SIDESDR DALA2019030301401Engine · leakingSHIP 3610 - ATO - DURING TAKEOFF FLAMES WERE REPORTED FROM TAILPIPE. CREW ABORTED TAKEOFF. MAINTENANCE REPORTED OIL LEAKAGE BEYOND AMM LIMIT. CORRECTIVE ACTION: MAINTENANCE REPLACED THE NUMBER 1 ENGINE.SDR DALA2020022001262Skin · dented(LOG 0952723) DURING 2KU WIFI UPGRADE SEVERAL MINOR DENTS WERE FOUND WITHIN THE 2KU MODIFICATION AREA. MAINTENANCE REPAIRED DAMAGE PER ERA 575609-14.SDR DALA2019022191095Terminal · shortedDURING EMERGENCY LIGHT CHECK FOUND GALLEY FLOOD EMERGENCY LIGHT OUT. T/S TO EMERGENCY CEILING LIGHT L1417 TERMINAL SHORTING TO GND. REPOSITION TERMINAL AND RESECURED. OPS CHECKS GOOD.SDR DALA2019020700861Skin Panel · crackedDURING INSPECTION FOUND 1/2 CRACK ON GROUND SVC PANEL FUSELAGE SKIN. INSTALLED CATEGORY "A" PERMANENT REPAIR PER SRM 53-10-15 REPAIR 4.SDR DALA2019020700860Tear Strap · damagedDAMAGE TO STATION A 727E TEARSTRAP REPAIRS BETWEEN STR 2LR/3LR.SDR DALA201901310642Battery · inoperative(LOG 5267966) DURING INSPECTION FOUND FIRST CLASS/GALLEY EMERGENCY LIGHTS INOPERATIVE. REPLACED FIRST CLASS/GALLEY EMERGENCY PATH LIGHTING BATTERY # M1674 PER B737-6789 AMM 33-51. OPS CHECK NORMAL.SDR DALA2018121707236Reservoir · overserviced(LOG 5212870) AFTER APU START GOT BLUE MAINT LIGHT W/ODO SMELL THROUGH PACKS USING APU AIR. FOUND BOTH HYDRAULIC RESERVOIR OVERSERVICED. DRAINED EXCESS FLUID. REMOVED AND REPLACED COALESCER BAGS PER B737 AMM 21-51. NO OIL CONTAMINATION. RAN PACKS USING APU ANDSDR DALA2018112206749Acm · frozenPACK AIR SURGED ON FINAL WITH A SMOKE/BURNT ODOR FOLLOWED BY A LEFT PACK TRIP OFF AFTER LANDING. MAINTENANCE FOUND ACM FROZEN. R&R LT PACK ACM PER AMM 21-51. OPERATIONAL CHECK OK.SDR DALA2018101506052Battery Pack · inoperative(LOG 5181344) DURING INSPECTION FOUND FUNCTIONAL CHECK EMERGENCY LIGHTING, SEAT MOUNTED LIGHT FAILED TEST POWERED BY M1669. M1670 & M1672 POWER PACK. R/R POWER SUPPLY M1669, M1670 & M1672 BATTERY PACK PER AMM 33-51-06. OPS CKD OK.SDR DALA2018090705484Eec · malfunctionedTOWER CANCELLED T/O CLEARANCE DUE TO FLAMES REPORTED FROM THE NR 1 ENGINE TAIL PIPE DURING TAXI. T/O ROLL DISCONTINUED AT APPROXIMATELY 20 KNOTS. MAINTENANCE REMOVED AND REPLACED EEC PER AMM 73-21. OPS CHECK OK.SDR DALA2018080304853Door Frame · damagedDURING INSPECTION FOUND DAMAGE TO THE E&E DOOR CUTOUT SURROUND STRUCTURE LBL 6.74 INTERCOSTAL WEB. MAINTENANCE REPAIRED DAMAGE PER ERA 570559-14.
Back to Boeing 737-732