What was found
(LOG 5662882) DURING INSPECTION FOUND FOUND TWO CRACKS IN LEFT W/W FWD BULKHEAD JUST FWD OF LT HYD FILTER ASSY. CLEANED AREA, 3" CRACK WAS BROKEN SEALER. REPAIRED 4" CRACK PER SRM 57-10-10 REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 5662882) DURING INSPECTION FOUND FOUND TWO CRACKS IN LEFT W/W FWD BULKHEAD JUST FWD OF LT HYD FILTER ASSY. CLEANED AREA, 3" CRACK WAS BROKEN SEALER. REPAIRED 4" CRACK PER SRM 57-10-10 REPAIR 2.