Boeing 737-790
Service difficulty reports · 4,137
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737790' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737790' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2017052621165Skin · crackedRIGHT HORIZONTAL STAB LOWER SURFACE SKIN AT CENTER OF HSS 138.70 FOUND TO HAVE 3/4 INCH CRACK. ACFT GROUNDED. REPAIRED THE SKIN.SDR SWAA2017052513988Light · looseLT OVERWING EXIT LIGHT LOOSE. R&R LIGHT ASSY PER MM.SDR ASAA2017051520794Roller · out of sequenceR2 DOOR WILL NOT CLOSE. ACFT GROUNDED. FOUND UPPER LATCH ROLLERS TO BE OUT OF SEQUENCE, RIGGED THE UPPER LATCH ROLLER CONTROL ROD AND HORIZONTAL CONTROL ROD IAW AMM 52-41-00. OPS CHECKED GOOD IAW AMM 52-41-00.SDR ASAA2017051420763Software · faultyUPON DIVERSION TO ANC THE FMC DID NOT DISPLAY TIME, WIND, AND FUEL CALCULATIONS. LNAV WAS OPERATIONAL. GROUNDED - YES. KNOWN ANOMALY WITH THE U11.0 OP PROGRAM SOFTWARE. NO FAULT LOGGED ON PREV FLT. NO HISTORY - 60 DAYS. OPS CHECK LT & RT FMC GOOD REF MM 34-61-SDR SWAA2017060514082Doubler · crackedL1 DOOR CUTOUT INTERNAL DOUBLER CLOSEOUT CRACKED BELOW LOWER HINGE CUTOUT. R & R DOUBLER IAW SRM AND DWG.SDR ASAA2017051020708Battery Pack · dischargedF/A REPORTS EMERGENCY EXIT LIGHTS IN AFT CABIN & EMERGENCY EXIT ROW ON WITH THE SWITCH IN THE ARMED POSITION. AFT GALLEY L/H EXIT, OVERWING RIGHT, AFT GALLEY OVERHEAD WITH EMERGENCY LIGHT SWITCH IN ARMED POSITION. GROUNDED - YES. EMERGENCY LIGHTS OPS CHECK GOOSDR SWAA2017052614011Web · corrodedTHRESHOLD SUPPORT WEB CORRODED AT BS 440 TO 496, RBL 25. REPAIRED THE SUPPORT WEB PER SRM.SDR SWAA2017052614009Sidewall Support · corrodedSIDEWALL SUPPORT CORRODED AT BS 500A TO 500D, RBL 20. REPAIRED THE SIDWALL SUPPORT IAW SRM.SDR SWAA2017052614008Sidewall Support · corrodedSIDEWALL SUPPORT CORRODED AT BS 400 TO 420, RBL 20. REPAIRED THE SIDWALL SUPPORT IAW SRM.SDR SWAA2017052614007Sidewall Support · corrodedSIDEWALL SUPPORT CORRODED AT BS 727 TO 767, RBL 21. REPAIRED THE SIDEWALL SUPPORT IAW SRM.SDR SWAA2017060614161Bulkhead Web · crackedMAIN WHEEL WELL VERTICAL PRESSURE WEB CRACKED AT BS 663, LBL 45. REPAIRED THE BULKHEAD WEB IAW SRM.SDR SWAA2017060614160Bulkhead Web · crackedMAIN WHEEL WELL VERTICAL PRESSURE WEB CRACKED AT BS 663, BETWEEN RBL 35 TO 45. REPAIRED THE BULKHEAD WEB IAW SRM.SDR ASAA2017042020514Guide Arm · out of adjustFA REPORTS L1 DOOR DIFFICULT TO OPEN. GROUNDED - YES. FOUND GUIDE ARM OUT OF ADJUSTMENT ADJUSTED GUIDE ARM REF AMM 52-11-00-820-801 STEP 2H(1) CHECKED HANDLE FORCE, HANDLE FORCE AND FLIGHT DECK LIGHTS CHECKED GOOD REF AMM 52-11-00-700-804.SDR SWAA2017042013255Holder · out of adjustR1 DOOR EMERGENCY EVAC SLIDE FORWARD GIRT BAR HOLDER OUT OF ADJUST. ADJUSTED HOLDER PER AMM.SDR SWAA2017060514107Threshold · corrodedFORWARD CARGO BAY LOWER MAIN SILL THRESHOLD WEB CORRODED BETWEEN BS 440 TO 492. R & R THE THRESHOLD IAW SRM AND DWG.SDR SWAA2017060514102Sidewall Support · corrodedFLOOR TO SIDEWALL BETWEEN CORRODED BETWEEN BS 500 TO 500D, LBL 24. R & R THE SIDEWALL SUPPORT IAW SRM.SDR SWAA2017060514085Sidewall Support · corrodedAFT CARGO BAY ON FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 847 TO 867, RBL 25. R & R THE SIDEWALL SUPPORT IAW SRM.SDR SWAA2017060514084Sidewall Support · corrodedAFT CARGO BAY ON FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 727 TO 767, RBL 25. R & R THE SIDEWALL SUPPORT IAW SRM.SDR SWAA2017060514083Threshold · corrodedAFT CARGO BAY ON SUB WEB THRESHOLD CORRODED. R&R THRESHOLD IAW SRM AND DWG.SDR SWAA2017060114103Support Angle · corrodedBULKHEAD SUPPORT ANGLE CORRODED AT BS 500D, LBL 26, WL 157. R & R THE SUPPORT ANGLE IAW SRM.SDR SWAA2017042713413Support · corrodedAFT CARGO BAY ON FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 727 TO BS 847, LBL 25. R&R SUPPORT PER SRM.SDR SWAA2017051613711Web · corrodedLEFT CREASE BEAM WEB CORRODED AT BS 710, WL 208. R & R THE WEB IAW SRM & EA.SDR ASAA2017031321295Stop Fitting · crackedAFT CARGO DOOR STOP PAD CRACKED ALL THE WAY ACROSS (AFT FITTING 3RD FROM BOTTOM). GROUNDED - YES. REMOVED AND REPLACED AFFECTED BEARING PLATE (STOP PAD) REF DRAWING 146A8214-2 SHEET 1 OF 3. VERIFIED STOP PIN GAP AT AFFECTED LOCATION. GAP WITHIN LIMITS, REF AMMSDR SWAA2017031412497Slide · unsecureL1 DOOR EVAC SLIDE FELL OUT OF CONTAINER. (DID NOT DEPLOY) REINSTALLED SLIDE PER MM.SDR ASAA2017030220220Support · corrodedLAVATORY SUPPORT BS 947 TO 967 IS CORRODED, FOUND UPON REMOVAL OF LAV MOUNT FITTING. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE SUPPORT IAW SRM 51-40-02-0G-0.SDR ASAA2017030220133Floor Support · corrodedLAVATORY SUPPORT BS 947 - 967 IS CORRODED, FOUND DURING REMOVAL OF THE LAVATORY MOUNT FITTING. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0.SDR ASAA2017030120162Floorbeam · corrodedSTA 986 FLOORBEAM HAS CORR AT RBL 34 TO RBL 44. GROUNDED - YES. CORROSION FOUND TO BE OUT OF LIMITS, REPAIRED DAMAGE TO BEAM UPPER CAP LBL 60 TO RBL 60 IAW SRM 53-70-51-2R-4 W 1.0 O .150 R .36 L 3.5 D .014.SDR ASAA2017030120160Floorbeam · corrodedSTA 947 FLOORBEAM HAS CORR NEAR LAV MOUNT AT RBL24. GROUNDED - YES. CORR FOUND TO BE OUT OF LIMITS, REPAIRED FLOORBEAM UPPER CAP IAW SRM 53-70-51-2R-5W 2.0 O .180 R .120 L 3.0 D .060".SDR ASAA2017030120052Angle · corrodedAPU AIR INLET BS 1088 BOTTOM SUPPORT STRUCTURE IS CORRODED ALONG ENTIRE LENGTH OF BOTTOM EDGE APPROX. 8 INCHES IN LENGTH. ACFT GROUNDED. REMOVED AND REPLACED THE ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA2017030120048Angle · corrodedAPU INLET TOP SURFACE AT BS 1088 HAS CORROSION ON TOP SUPPORT ANGLE. ACFT GROUNDED. REMOVED AND REPLACED THE ANGLE IAW SRM 51-40-02.SDR ASAA2017030120108Floorbeam · corrodedBS 986 FLOORBEAM HAS CORROSION LBL 30 -- 43. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED THE FLOORBEAM.SDR ASAA2017030120106Frame · crackedBS 727 BULKHEAD LT FRAME CRACKED. ACFT GROUNDED. REPAIRED THE FRAME.SDR ASAA2017030119986Lamp · inoperativeEMERGENCY FLOODLIGHT ON AFT WINDSCREEN ADJACENT TO LAVATORY D HAS SEVERAL LAMPS INOPERATIVE AND WITH CRACKED LENS. ACFT GROUNDED. REPLACED THE LAMPS AND LENS. TESTED IAW AMM 33-51-01-960-801. OPS NORMAL.SDR ASAA2017030119985Lens · brokenEMERGENCY LIGHT EXIT LOCATOR SIGN AT THE R2 DOOR HAS A BROKEN LENS. ACFT GROUNDED. REMOVED AND REPLACED THE LENS AND TESTED THE LIGHT ASSY IAW AMM 33-51-01-960-801, OPS NORMAL.SDR ASAA2017022820049Transition Panel · corrodedAFT CARGO BAY RT TRANSITION PANEL BS 727E - 787 CORRODED. ACFT GROUNDED. REPAIRED IAW SRM 53-00-53-2R-5.SDR ASAA2017022820129Tee Fitting · corrodedAFT CARGO, FLOOR SPLICE, BS 887 IS CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW DRAWING 146A9401 REV D, AND 1505-100543 REV B. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. LOCATED AND DRILLED NEW SPLICE ASSEMBLY IAW DRAWING 146A9401 REV A. REMOVED ASDR ASAA2017022820128Transition Panel · corrodedAFT CARGO BAY LT TRANSITION PANEL HAS CORROSION BS 727 + 4 - 847. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-40-02. FOUND BEYOND LIMITS IAW SRM 53-00-53-1A-2, FIG. 103. LOCATED, DRILLED A NEW TRANSITION PANEL AND FABRICATED A REPAIR SPLICE IAW DWG 146A75SDR ASAA2017022820109Cargo Track · crackedAFT CARGO BAY, CARGO TRACK CRACKED AT BS 727E - 747, RBL 13.84. ACFT GROUNDED. REPAIRED THE CARGO TRACK IAW SRM 53-00-53-2R-3.SDR ASAA2017022720105Transition Panel · crackedFWD CARGO COMPARTMENT RT TRANSITION PANEL BS 492-500A CRACKED. ACFT GROUNDED. REMOVED & REPLACED THE TRANSTION PANEL BS492-500AS IAW B737 700 SRM 51 40 02 0G 0.SDR SWAA2017030212244Shield · brokenAFT EMERGENCY FLASH LIGHT SHIELD BROKEN. R&R SHIELD IAW AMM.SDR ASAA2017020319677Battery Pack · dischargedFWD CABIN COMPARTMENT OVERHEAD EMERGENCY LIGHT INOPERATIVE. ACFT GROUNDED. CHECKED WIRING IAW WDM 33-51-12. REMOVED & REPLACED BATTERY PACK ASSY, M1674, IAW WDM 33-51-12. OPS CHECKED GOOD.SDR ASAA2017020319642Floor Panel · gougedAFT CARGO FLOOR PANEL 140 BF GOUGED. ACFT GROUNDED. FABRICATED A NEW FLOOR PANEL IAW GPM SECTION 05-00-854-A(2), AND DWG 453A2610 REV E.SDR SWAA2017020211647Lens · defectiveR1 DOOR LOWER EMERGENCY EXIT SIGN LENS MISSING DIRECTIONAL ARROW. R&R LENS IAW AMM.SDR SWAA2017020211624Lens · defectiveL2 DOOR EXIT SIGN COVER LENS MISSING ARROW. R&R LENS IAW AMM.SDR SWAA2017020211623Lens · defectiveR2 DOOR EXIT SIGN COVER LENS MISSING ARROW. R&R LENS IAW AMM.SDR SWAA2017020211622Lens · defectiveL1 DOOR LOWER EMERGENCY EXIT SIGN LENS MISSING DIRECTIONAL ARROW. R&R LENS IAW AMM.SDR ASAA2017012719843Cargo Track · crackedAFT CARGO BAY, RT CARGO TRACK IS CRACKED IN RADIUS OF VERTICAL LEG AT BS 747. ACFT GROUNDED. REPAIRED THE CARGO TRACK IAW SRM 53-00-53-2R-3, REPAIR 3.SDR ASAA2017012719824Cargo Track · crackedAFT CARGO BAY, RT CARGO TRACK IS CRACKED IN RADIUS OF VERTICAL LEG AT BS 727E. ACFT GROUNDED. REPAIRED THE CARGO TRACK IAW SRM 53-00-53-212-3.SDR ASAA2017012319706Crease Beam · corrodedRIGHT CREASE BEAM OUTER ANGLE CORRODED AT AFT CORNER OF R1 DOOR OPENING. ACFT GROUNDED. FOUND TO HAVE 100% MATERIAL LOSS AND OUT OF LIMITS IAW SRM 53-10-15, REPAIRED IAW EA 700-53EA-18397 REV 00.SDR ASAA2017011819450Sign · brokenEMERGENCY LIGHT EXIT LOCATOR SIGN BROKEN AT L2 DOOR. GROUNDED. REMOVED, REPLACED, AND TESTED L1190 EXIT SIGN IAW AMM 33-51-01-960-802. OPS NORMAL.
Back to Boeing 737-790