SDR ASAA2017010819455Floor Support · gougedAFT CARGO BAY FLOOR SUPPORT UPPER STRAP GOUGED AT BS 831, RBL 6. ACFT GROUNDED. REMOVED DAMAGED UPPER STRAP IAW SRM 51-40-02. FABRICATED A NEW UPPER STRAP IAW DWG 146A8134 REV-, ALODINED AND PRIMED THE STRAP IAW SRM 51-20-01, INSTALLED IAW DWG 146A8130 REVSDR ASAA2017010819454Transition Panel · corrodedAFT PIT RIGHT TRANSITION PANEL HAS CORROSION NUMEROUS SPOTS BETWEEN BS 727+5 AND 767. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED THE TRANSITION PANEL IAW SRM 51-40-02 AND SRM 53-00-SDR ASAA2017010719580Transition Panel · dentedFWD PIT RT TRANSITION PANEL DENTED AT STA 500B. GROUNDED - YES. REMOVED TRANSITION PANEL IAW SRM 51-40-02, DAMAGE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53. REMOVED AND REPLACED NEW TRANSITION PANEL IAW SRM 53-00-53-2R-6.SDR ASAA2017010519268Gust Lock · stuckL1 DOOR IS DIFFICULT TO CLOSE. ACFT GROUNDED. FOUND THE GUST LOCK STUCK. CLEANED, LUBED, AND EXERCISED THE GUST LOCK. OPS CHECKED GOOD.SDR ASAA2017010419641Floor Panel · gougedAFT CARGO FLOOR PANEL 140AF GOUGED. ACFT GROUNDED. FOUND TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-1 STEP 5A 1(B), FABRICATED A NEW FLOOR PANEL IAW DWG 453A2610 REV B, AND EPM 05-00-85 4.A.2.SDR ASAA2017010419632Floor Panel · gougedAFT CARGO FLOOR PANEL 140CF GOUGED. ACFT GROUNDED. FLOOR PANEL SCRATCHES AND GOUGES OUT OF LIMITS IAW SRM 53-00-53-1A-1 STEP 5.B.1. FABRICATED A NEW FLOOR PANEL IAW DWG 453A2610 REV C AND GPM 05-00-85 STEP 4.A.(2),SDR ASAA2017010419579Floor Panel · gougedAFT CARGO FLOOR PANEL 140 DF GOUGED ALL OVER. GROUNDED - YES. GOUGE ON PANEL 140DF IN AFT CARGO IS OUT OF LIMITS IAW SRM 53-00-53-1A-1. FABRICATED NEW PANEL IAW BAC DWG 453A2610 REV B & GPM 05-00-85 SECT 4-A-2. ALODINED, AND PRIMED ALSO IAW AMM 51-21-41, AMM51SDR ASAA2017010319687Floor Panel · gougedFWD PIT FLOOR PANEL 120AF IS GOUGED ALL OVER. GROUNDED - YES. FWD PIT FLOOR PANEL 120AF EXCEEDING ALLOWABLE DAMAGE, OUT OF LIMITS IAW SRM 53-00-53-1A-1, MAT ID FOR PANEL IS 2024-T3 .071 PO 875620.3 IAW DWG 453A1610 REV T. FABRICATED NEW FLOOR PANEL 120AF IAW DSDR ASAA2017010319640Floor Panel · gougedFWD CARGO FLOOR PANEL 120CF IS GOUGED. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. FABRICATED A NEW FLOOR PANEL IAW GPM 05-00-85 4.A.2 & DWG 453A1610 REV C.SDR ASAA2017010319639Floor Panel · gougedFWD CARGO FLOOR PANEL 120BF IS GOUGED. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1, FABRICATED A NEW FLOOR PANEL IAW GPM SECT. 05-00-85,4.A2 & DWG 453A1610 REV B.SDR ASAA2017010219235Connector · disconnectedRIGHT OVERWING EMERGENCY EXIT SIGN INOPERATIVE. ACFT GROUNDED. FOUND L1188 CONNECTORS DISCONNECTED & STOWED. RECONNECTED D3666 & D3668. IAW SSM 33-51-21. OPS CHECKED NORMAL.SDR ASAA2017010219234Connector · disconnectedAISLE EMERGENCY LIGHT AT 8ABC INOPERATIVE. ACFT GROUNDED. FOUND LIGHT ASSY CONNECTOR DISCONNECTED. CONNECTED THE LIGHT ASSY. OPS CHECKED NORMAL, IAW SSM 33-51-13.SDR ASAA2016122619169Lens · detachedEMERGENCY LIGHT EXIT SIGN LENS FALLING OFF OF LIGHT ASSY AT L-2 DOOR. ACFT GROUNDED. REMOVED AND REPLACED THE LENS AND TESTED LIGHT ASSY IAW AMM 33-51-01-960-801 - OPS NORMAL.SDR ASAA2016122021276Battery Pack · no testEMERGENCY LIGHT BATTERIES FAILED CAPACITY CHECK DURING ACCOMPLISHMENT OF T/C 78233001. ACFT GROUNDED. REPLACED THE BATTERY PACKS. OPS CHECKED OK, IAW AMM 33-51-06-960-805.SDR ASAA2016122019113Battery Pack · no testALL EMERGENCY LIGHT BATTERIES FAILED CAPACITY CHECK DURING ACCOMPLISHMENT OF T/C 78233001. ACFT GROUNDED. REPLACED THE EMERGENCY LIGHT BATTERIES. OPS CHECKED OK IAW AMM 33-51-06-960-805.SDR SWAA2016121910619Slide · looseL1 DOOR EMERGENCY EXIT SLIDE LOOSE. SECURED SLIDE PER MT.SDR ASAA2016121219025Circuit Breaker · trippedDURING CRUISE AT FL380, RECEIVED A FUEL IMBALANCE. DECIDED NO FUEL LEAK AND PROCEEDED TO CROSSFEED AND CROSSFEED WOULD NOT OPEN. FUEL FLOW NORMAL. BOTH ENGINE TAKING FUEL FROM NR 1 TANK. ACFT GROUNDED. INSPECTED FUEL CROSSFEED VALVE & FOUND MANUAL INDICATIONSDR ASAA2016120818996Door · dirtyL1 DOOR DIFFICULT TO CLOSE. GROUNDED - YES. CLEANED & LUBED L1 DOOR, OPS CK OK.SDR ASAA2016120618963Light · inoperativeEMERGENCY LIGHT AREA LIGHT (AISLE LIGHT) INOP AT ROW 8 LEFT. GROUNDED - YES. RELAMPED AND TESTED PER AMM 33-51-03-960-801. OPS NORMAL.SDR SWAA2016120610255Lens · looseLT OVERWING EXIT INDICATOR LENS LOOSE. SECURED LENS IAW SIP.SDR ASAA2016113018946Flange · corrodedBS 1088 BULKHEAD APU AIR INTAKE LOWER FLANGE IS CORRODED. ACFT GROUNDED. REMOVED CORRSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-80-08-1A-1 STEPS 4E.2.A.1 FIG 103 DETAIL E. REMOVED AND REPLACED THE FLANGE IAW SRM 51-40-02 0G 0 FIG 8.SDR ASAA2016112821269Stop Fitting · crackedFWD CARGO DOOR LOWER FWD STOP FITTING CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE STOP FITTING BEARING PLATE IAW DWG 146A8214-2. VERIFIED RIG ON LOWER FWD STOP FITTING PLATE IAW AMM 52-31-00. OPS CHECKED GOOD.SDR ASAA2016112619015Angle · corrodedAFT CARGO COMPARTMENT BULKHEAD ANGLE IS CORRODED ON UPPER AND LOWER SURFACES. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE ANGLE IAW SRM 1 40 02 0GSDR ASAA2016112618947Transition Panel · corrodedAFT CARGO COMPARTMENT TRANSITION PANEL AT BS 847-867, STRINGER 25R IS CORRODED ON UPPER AND LOWER SURFACES. ACFT GROUNDED. REMOVED AND REPLACED IAW SRM 51-40-02-0G.SDR ASAA2016112618934Transition Panel · corrodedAFT CARGO COMPARTMENT TRANSITION PANEL AT BS 767 - 787 STRINGER 25R IS CORRODED ON UPPER AND LOWER SURFACES. ACFT GROUNDED. REMOVED AND REPLACED IAW SRM 51-40-02-0G-0 PARA 4 AND 7D.SDR ASAA2016112618924Frame Splice · corrodedAFT CARGO BAY FRAME SPLICE AT BS 787 STRINGER 25R IS CORRODED. ACFT GROUNDED. BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE FRAME SPLICE IAW SRM 53-00-07-1A-1, 43-00-07-01-1, AND 51-40-02-0G-0.SDR ASAA2016112518933Angle · crackedFWD CARGO COMPARTMENT BAFFLE ANGLE CRACKED AT RT BS 500C. ACFT GROUNDED. REMOVED, FABRICATED NEW AND INSTALLED NEW BAFFLE ANGLE IAW DWG 143A7502 AND SRM 51-40-02-0G-0.SDR ASAA2016112418833Lens · detachedEMERGENCY EXIT PLACARD (LEFT SIDE) FELL OFF. GROUNDED, YES. RE-INSTALLED LEFT SIDE EMERGENCY EXIT SIGN LENS COVER REFERENCE AMM TASK 33-51-01-960-801.SDR ASAA2016112318937Attach Bracket · corrodedTAIL COMP (H HOLE) BS 1088 BULKHEAD APU AIR INTAKE UPPER ATTACH FLANGE ON BULKHEAD CORRODED. ACFT GROUNDED. REMOVED CORRORSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53 80 08 1A 1 STEPS 4E.2.A.1 FIG 103 DETAIL E. REMOVED DAMAGE IAW SRM 51 40 02 0G 0 FIG 8, FABRSDR ASAA2016111719502Web · corrodedCORROSION FOUND ON AFT PIT LWR MAIN SILL WEB. ACFT GROUNDED. REPLACED SILL WEB.SDR ASAA2016111718730Door Sill · corrodedAFT CARGO PIT CENTER SCUFF PLATE CENTER AREA HAS SUSPECTED CORROSION. GROUNDED - YES. REPLACED SILL WEB IAW SRM 51-40-02SDR ASAA2016111518705Floor Panel · corrodedCOCKPIT STEP FLOOR PANEL 141A5133-15 SEVERELY CORRODED. GROUNDED - YES. LOCATED AND DRILLED NEW FLOOR PANEL IAW B737-700 SRM 51-40-05, TOP COATED PANEL IAW B737-700 AMM 25-00-00.SDR ASAA2016111318660Sign · detachedEXIT PLACARD FELL OFF ADJACENT TO R1 DOOR. ACFT GROUNDED. REPLACED R1 DOOR EMERGENCY EXIT FLOOR PROXIMITY LIGHT ASSY, IAW AMM 33-51-14, OPS CHECKED GOOD.SDR ASAA2016111318661Sign · missingEXIT SIGN FOR L2 DOOR MISSING. ACFT GROUNDED. REPLACED MISSING EXIT SIGN FOR L2 DOOR.SDR ASAA2016111318659Lamp · failed19 LT OVERHEAD BIN EMERGENCY LIGHT INOPERATIVE. ACFT GROUNDED. REPLACED THE LAMP IAW AMM 33-51-03. OPS CHECKED GOOD.SDR SWAA2016112809947Rib · crackedLEFT WING NR 1 SLAT LEADING EDGE LOWER AT ACTUATOR RIB CRACKED. R & R NR 1 SLAT IAW AMM.SDR ASAA2016110518760Floor Support · corrodedCOCKPIT FLOOR BS 270 BL 0 ANGLE CORRODED. ACFT GROUNDED. REPAIRED BS 270 THE FLOOR SUPPORT IAW 700-53EA-18037 REV 00, AND REO-G20417 REV A.SDR ASAA2016110518597Channel · corrodedAFT CARGO RT TRANSITION PANEL CHANNEL IS CORRODED AT BS 727D. ACFT GROUNDED. REMOVED CORROSION, FOUND BEYOND ALLOWABLE SRM LIMITS, IAW SRM 53-00-53. INSTALLED REPAIR IAW DWG 146A7500 REV C AND SRM 53-00-53. .SDR ASAA2016110418716Floor Support · corrodedCOCKPIT FLOOR STA 270 BL0 FLOOR SUPPORT IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED SUPPORT CHANNEL IAW DWG 141A5210 REV- AND SRM 51-40-02.SDR SWAA2016111509724Scuff Plate · crackedFORWARD CARGO DOOR CUTOUT CENTER SCUFF PLATE CRACKED AT AFT END. R&R SCUFF PLATE IAW AMM & EA.SDR ASAA2016110219825Strap · corrodedFRAME BS 540 BETWEEN STRINGERS 9 & 10L. FOUND CORROSION ON STRAP ATTACHED ON INNER FRAME. ACFT GROUNDED. THE STRAP WAS REMOVED IAW SRM 51-40-02. A NEW STRAP WAS FABRICATED IAW A0098068002. THE. STRAP WAS INSTALLED IAW SRM 51-40-02.SDR ASAA2016110218725Support Fitting · corrodedSUPPORT FITTING CORRODED BS 947-967 LBL 45. GROUNDED - YES. LOCATED AND DRILLED NEW SUPPORT FITTING IAW DWG 147A5660. FITTING TO BE INST ON CARD G754113 N/R 26613.SDR ASAA2016110218724Support Fitting · corrodedSUPPORT FITTING CORRODED BS 947-967 RBL 25 45. GROUNDED - YES. LOCATED AND DRILLED NEW SUPPORT IAW DWG 147A5660. SUPPORT WILL BE INST ON CARD G754113 N/R 26613.SDR ASAA2016103118703Floor Support · crackedFLOOR SUPPORT CRACKED BS 986 - 1006 LBL 30. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02 AND SRM 53-70-51 & DWG 147A5700 REV-.SDR ASAA2016103118614Web · corrodedRIGHT CREASE BEAM WEB CORRODED BS 947 - 992. ACFT GROUNDED. REMOVED CORRODED WEB IAW SRM 51-10-2, FABRICATED NEW WEB IAW DWG 147A8510-51 REV E AND INSTALLED WEB IAW DWG 147A8501 REV-.SDR ASAA2016103018704Web · corrodedCREASE BEAM WEB AT RT BS 992-1006 CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02 AND FOUND OUT OF LIMITS IAW SRM 53-70-15-1A-1 FIG 103. REMOVED AND REPLACED THE WEB IAW SRM 51-40-02, DWG 147A8510 REV A, SRM 51-20-01.SDR ASAA2016102918759Frame · corrodedFRAME AT LEFT SIDE WALL CORRODED . BS 559, STRINGERS 16 - 17L. ACFT GROUNDED. ACCOMPLISHED REPAIR IAW REO-G20407 REV A AND EA 700-53EA-18015 REV 00.SDR ASAA2016102918722Seat Track · corrodedSEAT TRACK CORRODED AT SEVERAL SPOTS. BS 540 - BS 706, RBL 45.57. GROUNDED - YES. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-40-52-1A-1, ORIGINAL MATERIAL THICKNESS IS 0.146 IN, REMAINING THICKNESS IS 0.080 IN, REMOVED 0.066 IN. REMOVED SEASDR SWAA2016111409614Skin · crackedRT WING NR 8 SLAT LEADING EDGE LOWER NOSE SKIN AT ACTUATOR RIB CRACKED AT STA 451.9. REPAIRED NR 8 SLAT IAW SRM.SDR ASAA2016102818758Frame · corrodedMAIN CABIN LT STUB FRAME BS 693.75 HAS CORROSION. ACFT GROUNDED. REPAIRED THE FRAME BETWEEN STRINGERS 16 -17L IAW 700-53EA-18018 REV 00, AND REO-G20401 REV A.
Back to Boeing 737-790