SDR SWAA2016102409017Skin · crackedRT WING NR 8 SLAT NOSE SKIN CRACKED AT STA 451.97. REPAIRED SKIN IAW SRM AND DWG.SDR SWAA2016101308719Skin · crackedLT WING NR 4 SLAT NOSE SKIN CRACKED AT STATION 85.19. REPAIRED SKIN IAW SRM.SDR SWAA2016092308063Stiffener · crackedRIGHT MLG CENTER WING SECTION REAR SPAR BULKHEAD STIFFENER CRACKED AT STA 663, RBL 25. R & R STIFFENER IAW SRM.SDR SWAA2016092308062Stiffener · crackedLEFT MLG CENTER WING SECTION REAR SPAR BULKHEAD STIFFENER CRACKED AT STA 663, LBL 10.54. R & R STIFFENER IAW SRM.SDR COZA20160921095Controller · intermittentRIGHT PACK LIGHT ILLUMINATED DURING RECALL TEST DURING DESCENT INTO OAKLAND. PERFORMED BITE CHECK ON RIGHT PACK/ZONE TEMPERATURE CONTROLLER PER FIM 21-61 TASK 801. FOUND RAM AIR ACTUATOR, TRIM VALVE ZONE FWD, TCV AND FLIGHT DECK TRIM AIR VALVE LIGHT ILLUMINASDR SWAA2016091255688Battery · dischargedLEFT OVERHEAD BIN EMERGENCY LIGHT INOPERATIVE BETWEEN ROW 3 TO ROW 6. R & R BATTERY IAW MM.SDR SWAA2016091255689Battery Pack · dischargedRIGHT OVERWING EXIT SIGN LIGHT INOPERATIVE. R & R BATTERY PACK IAW AMM.SDR COZA20160825091Spar · corrodedCORROSION WAS FOUND ON THE FORWARD SIDE OF THE RIGHT WING SPAR AT THE NR 2 FORWARD BOOST PUMP. THE CORROSION WAS LOCATED DIRECTLY ABOVE AND BELOW THE PUMP RADIATING OUT FROM THE BONDING JUMPER ATTACH POINTS. THE CORROSION WAS REMOVED, SPAR NDT'D AND REMAININSDR SWAA2016071553840Lens · brokenFORWARD ENTRY DOOR EMERGENCY EXIT SIGN LENS BROKEN. R & R LIGHT ASSEMBLY IAW MM.SDR SWAA2016062253111Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MAINTENANCE.SDR COZA20160608078Controller · faultedAMBER, AUTO FAIL, ANNUNCIATOR ON THE PRESSURIZATION PANEL ILLUMINATED IN THE COCKPIT. BITE CHECKS WERE PERFORMED ON THE PRESSURE CONTROLLERS. 1 CONTROLLER SHOWED A MESSAGE FOR AN INTERNAL FAULT. CONTROLLER WAS REPLACED AND OPS CHECK NORMAL.SDR SWAA2016062153084Skin · delaminatedLEFT WING OTBD AFT FLAP AFT INBD CORNER SKIN DELAMINATED. R & R AFT FLAP IAW AMM.SDR SWAA2016052452042Battery · dischargedAFT RT FLASHLIGHT INOPERATIVE. R & R BATTERY IAW AMM.SDR SWAA2016051951947Support Bracket · crackedLEFT WING UPPER SHELF PANEL ABOVE PYLON CTR AFT SUPPORT BRACKET CRACKED. R & R BRACKET IAW SRM.SDR SWAA2016051951946Latch · looseR2 DOOR EMER EVAC SLIDE LATCH LOOSE. SECURED LATCH IAW AMM.SDR SWAA2016050451541Lens · looseR1 DOOR EMER LIGHT LENS COVER LOOSE. R & R LIGHT ASSEMBLY IAW AMM.SDR SWAA2016050451540Girt Bar · out of positionR1 DOOR EMER EVAC SLIDE OUT OF POSITION. REPOSITIONED GIRT BAR IAW MT.SDR COZA20160226077Pressure Switch · failedDURING APU START, APU LOW OIL PRESSURE LIGHT ILLUMINATED AND APU AUTO SHUTDOWN. TROUBLESHOOTING USING THE FAULT ISOLATION MANUAL FOUND THE LOW OIL PRESSURE SWITCH FAILED. REPLACED THE SWITCH, OPS CHECK NORMAL.SDR SWAA2016022349336Cover · missingRIGHT LOWER OVERWING EXIT SIGN COVER MISSING. R & R SIGN ASSEMBLY IAW MM.SDR SWAA2016012548342Light · inoperativeRIGHT BULLNOSE EMER EXIT LIGHT INOPERATIVE AT ROW 19. R & R LIGHT IAW AMM.SDR COZA20151218073Pitot Tube · failedLEFT ELEVATOR PITOT, AMBER ANNUNCIATION CAME ON AND ELEVATOR PITOT LT, CIRCUIT BREAKER TRIPPED. REPLACED LT ELEVATOR FEEL PITOT PROBE AND OPS CHECK NORMAL.SDR SWAA2015111946231Slide · unsecureL1 DOOR EMER EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. R & R SLIDE IAW MT.SDR COZA20151119066Control Panel · malfunctionedLANDING ALTITUDE WINDOW BLANK ON THE CABIN PRESSURIZATION CONTROL PANEL. USING THE DIM AND LIGHTS TEST, CONFIRMED CONTROL PANEL FAILED INTERNALLY. REPLACED THE PRESSURIZATION CONTROL PANEL AND OPS CHECK NORMAL.SDR COZA20151119065Panel · stuckWHILE PERFORMING CENTER FUEL TANK AUTO SHUTOFF TEST, FOUND RT CENTER FUEL TANK TEST SWITCH STICKING. REPLACED FUEL TEST PANEL P61-8 AND OPS TEST NORMAL.SDR COZA20151112064Antenna · inoperativeNUMBER 2 ADF FAILED TO OPERATE & WAS TROUBLE SHOT TO THE ANTENNA. REPLACED THE ANTENNA & NR 2 ADF OPERATES CORRECTLY.SDR COZA20151112063Pcu · leakingUPPER AILERON PCU LEAKING FLUID FROM OUTPUT SHAFT. REPLACED AILERON PCU & NO LEAKS FOUND.SDR COZA20151112062Pcu · leakingLOWER AILERON PCU LEAKING FLUID FROM OUTPUT SHAFT. REPLACED AILERON PCU & NO LEAKS FOUND.SDR COZA20151112061Metering Valve · leakingLEFT BRAKE METERING VLV LEAKING FLUID FROM VLV BODY. REPLACED VLV & NO LEAKS FOUND.SDR SWAA2015110245633Battery Pack · dischargedRIGHT SIDE EMER EXIT LIGHT INOPERATIVE. R & R BATTERY PACK IAW AMM.SDR COZA20150819060Overheat Sensor · false indicationRT WING BODY OVERHEAT LIGHT ILLUMINATED. BITE CHECK OF THE COMPARTMENT OVERHEAT DETECTION CONTROL UNIT DISPLAYED FAULT CODE 64. RESISTANCE CHECKS ON SENSING ELEMENTS ASSOCIATED WITH THIS CODE WERE PERFORMED. THE RT INBD L/E ELEMENT M1269 WAS FOUND OUT OF LISDR SWAA2015081442845Battery Pack · dischargedRIGHT CABIN CTR AISLE EMER EXIT LIGHT INOPERATIVE BETWEEN BS 500D TO 680. R & R BATTERY PACK IAW AMM.SDR SWAA2015072742227Retaining Clip · looseR1 DOOR EVAC SLIDE GIRT BAR FWD RETAINER CLIP LOOSE. SECURED CLIP PER MM.SDR SWAA2015072742224Battery · failedEMERGENCY LIGHT BATTERY PACK M1672 FAILED CAPACITY TEST. R & R BATTERY IAW MM.SDR SWAA2015071341862Engine · failedABORTED TAKEOFF. AT APPROX 50 KNOT ON TAKEOFF ROLL, NR 2 ENG FAILED. R & R NR 2 ENG IAW MT.SDR COZA20150702055Switch · stickingNR 2 AUDIO PANEL SELECT, SWITCH STICKS WHEN NR 1 SELECTED. REPLACED NR 2 AUDIO PANEL AND OPS CHECK NORMAL.SDR SWAA2015062541111Battery · failedFORWARD RT EMER BATTERY PACK FAILED FUNCTIONAL CHECK. R & R BATTERY IAW MM.SDR COZA20150625054Smoke Detector · faultyAFT CARGO BAY FIRE LOOP "B" INOPERATIVE. REPLACED AFT CARGO PIT FIRE DETECTOR, OPS CHECK OK.SDR COZA20150615053Pitot Tube · inoperativeRT ELEVATOR FEEL PITOT HEAT LIGHT CAME ON AND THE CIRCUIT BREAKER TRIPPED. REPLACED THE ELEVATOR FEEL PITOT PROBE. OPS CHECKED NORMAL.SDR SWAA2015061140577Lens · missingTHE R2 DOOR EXIT LIGHT LENS FOUND TO BE MISSING. R & R THE EXIT LIGHT ASSY IAW MM.SDR COZA20150604052Sensor · false indicationINTERMITTENT RT WING BODY OVERHEAT LIGHT. BITE CHECK ON THE COMPARTMENT OVERHEAT DETECTION CONTROL UNIT SHOWED FAULT CODE 64. LEAK CHECK PERFORMED ON PNEUMATIC DUCTS IN THE RT WING, RT PYLON AND ECS BAY WITH NO LEAKS FOUND. USING THE FIM AND OVERHEAT DETECTSDR COZA20150604051Sensor · false indicationINTERMITTENT RT WING BODY OVERHEAT LIGHT. BITE CHECK ON THE COMPARTMENT OVERHEAT DETECTION CONTROL UNIT SHOWED FAULT CODE 64. LEAK CHECK PERFORMED ON PNEUMATIC DUCTS IN THE RIGHT WING, RIGHT PYLON AND ECS BAY WITH NO LEAKS FOUND. USING THE FIM AND AN OVERHESDR SWAA2015052740084Sign · misalignedR1 DOOR EMER EXIT SIGN MISALIGNED. R & R SIGN IAW SIP.SDR SWAA2015052740083Sign · misalignedL1 DOOR EMER EXIT SIGN MISALIGNED. R & R SIGN IAW SIP.SDR SWAA2015052039870Battery · dischargedAFT OTBD EMER FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT BATTERY IAW SIP.SDR SWAA2015040238869Light · inoperativeRIGHT OVERWING EMER EXIT LIGHT INOPERATIVE. RELAMPED LIGHT IAW MM.SDR SWAA2015042138731Relay · failedAIR TURN BACK LT CTR FUEL PUMP INOPERATIVE. R & R UNIVERSAL FAULT INTERRUPTER RELAY IAW MM.SDR COZA20150226047Sensor · defectiveON DECENT, RT DUCT PRESSURE INDICATED 15 PSI WITH LT PRESSURE AT 40 PSI. BLEED TRIP LIGHT ILLUMINATED. REPLACED PRE-COOLER CONTROL VALVE SENSOR AND BLEED SYSTEM OPERATED NORMALLY.SDR COZA20150226046Control Valve · inoperativeON DECENT, RT DUCT PRESSURE INDICATED 15 PSI WITH LT PRESSURE AT 40 PSI. BLEED TRIP LIGHT ILLUMINATED. REPLACED PRE-COOLER CONTROL VALVE AND BLEED SYSTEM OPERATED NORMALLY.SDR SWAA2015021636636Light · missingFWD ENTRY EMER EXIT LIGHT MISSING. INSTALLED LIGHT ASSEMBLY IAW MM.SDR SWAA2015012035914Window Frame · crackedRIGHT NR 3 FLIGHT DECK WINDOW FRAME CRACKED AT 2ND TO BOTTOM FASTENER HOLE ALONG THE E-F POST. REPAIRED FRAME IAW ACO.
Back to Boeing 737-7BX