Service difficulty report · Sensor · Boeing 7377BX

Difficulty date
June 1, 2015
Submitted
June 5, 2015
Operation
Air carrier
Aircraft
N737KA
Make and model
Boeing 7377BX
Aircraft serial
30740
Aircraft time
27,986 hours, 16,835 cycles
Part
Sensor
Part number
3571279
Condition
False Indication
Location
Rt Overheat
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INTERMITTENT RT WING BODY OVERHEAT LIGHT. BITE CHECK ON THE COMPARTMENT OVERHEAT DETECTION CONTROL UNIT SHOWED FAULT CODE 64. LEAK CHECK PERFORMED ON PNEUMATIC DUCTS IN THE RT WING, RT PYLON AND ECS BAY WITH NO LEAKS FOUND. USING THE FIM AND OVERHEAT DETECTION MODULE TEST BOX FOUND SENSING ELEMENT M1763 IN THE RT ENGINE PYLON TO BE FAILING A VOLTAGE TEST. REPLACED SENSING ELEMENT M1763 AND ALSO SENSING ELEMENT M1764. SDR COZA20150604051 FOR REPLACEMENT OF ELEMENT M1764. NO OVERHEAT LIGHT DURING SUBSEQUENT FLIGHT.