Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024041564299Strap · corrodedCORROSION ON NUT-PLATE STRAP ACB STA-787+3'' RBL-21<[01] REMOVED AND INSTALLED NEW NUT-PLATE STRAP ON AFT CARGO BAY BS 787+3'; RBL 21 I.A.W. SRM 51-40-02-0G-0; DWG# 146A8340 SHEET 19;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2024041564284Strap · corrodedCORROSION ON TENSION STRAP THRESHOLD AREA ACB DOOR<[01] REMOVED AND INSTALLED NEW TENSION STRAP ON ACB P/N 146A8128U14 I.A.W. SRM 51-40-02-0G-0 DWG.# 146A8120SDR SWAA2024041564285Web · corrodedCORROSION ON THRESHOLD WEB ACB<[01] UPDATE TO WATERLINE;[02] CERTIFY;[03] 01 - REMOVED AND REPLACED PER [SRM 51-40-02-0G-0-A00729 (GENERAL - FASTENER INSTALLATION AND REMOVAL - AIRFRAME - PERMANENT)]<BR><BR>TASK CARD COMPLETED.;[04] VERIFIED CORRECTIVE ACTION SDR SWAA2024041564291Cargo Track · corrodedCORROSION ON RAIL TRACK ACB STA-927+18'' RBL-8<[01] REMOVED AND REPLACED RAIL TRACK BETWEEN BS 887 TO BS 947+3'; RBL 8 AT ACB PER SRM 51-40-02.AND DWG 147A7500 REV: - DUE TO FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2;[02] VERIFIED CORRECTIVE ACTION COMPLETSDR SWAA2024041564296Cargo Track · corrodedCORROSION CARGO TRACK TIE-DOWN ACB LBL-17 STA-807. UPON FURTHER INVESTIGATION DEFECT IS FOUND AT CARGO TRACK TIE-DOWN ACB LBL-17 STA- 787<[01] REMOVED CORROSION ON CARGO TRACK TIE-DOWN ACB LBL-17 STA-787. DEFECT FOUND TO BE IN LIMITS. TREATED AND PRIMED REWORKSDR SWAA2024041164430Fitting · crackedREPLACE SLAT 8 DUE TO INTERNAL CRACK WAS FOUND ON ACTUATOR FITTING. REMOVED LEADING EDGE SLAT # 8 IN UNSERVICEABLE CONDITION AND REINSTALLED LEADING EDGE SLAT #8 IN SERVICEABLE CONDITION IAW AMM 27-81-21-401. <BR>SEE TTG8Q00S5Z06 FOR REMOVAL AND INSTALLATIONSDR SWAA2024040364435Scuff Plate · crackedFORWARD SERVICE DOOR SCUFF PLATE IS CRACKED ALONG EDGE. (MARKED)<[01] STEPS # 1 AND STEP # 4 COMPLETE;;[02] REPAIR COMPLETE;[03] VERIFIED TASK COMPLETEDSDR SWAA2024042664037Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED BS 727D CEILING AREA AFT CARGO COMPARTMENT 2024-195702 CRACK ANGLE - SUPPORT LOCATED BS727A TO BS747 CEILING AREA AFT CARGO COMPARTMENT<[01] PERFORMED DETAILED VISUAL INSPECTION ON ANGLE - SUPPORT LOC. AT BS727A TO BS747 CEILING ASDR SWAA2024041563769Floor Support · crackedCRACKED INTERCOSTAL AT STA 344+9; LBL 11; WL 208.1.<[01] UPDATED MEASUREMENT TABLE AND STEPS 1-3;[02] UPDATED STEPS 4;5;[03] STEP 5 COMPLETE;[04] MEASURMENT TABLE EDIT. PART IS NOT RII FOR REMOVAL AND REPLACEMENT.;[05] CERTIFY EDIT TO MEASUREMENT TABLE;[06] STSDR SWAA2024041563776Floor Support · crackedCRACKED INTERCOSTAL AT STA 344+9 BL 0; WL 208.1<[01] STARTED FASTENER REMOVAL IAW SRM 51-40-02-0G-0;[02] UPDATED STEPS 1-3;[03] STEPS 4;5 UPDATED;[04] UPDATED MEASUREMENT TABLE;[05] STEP 5 COMPLETE;[06] EVALUATED CRACKED INTERCOSTAL AND FOUND IT TO BE OUT OF LSDR SWAA2024041563770Floor Support · corrodedCORROSION ON INTERCOSTAL FASTENER HOLES AT STA 328+3; AND STA 328+11; LBL 12; WL 208.1<[01] UPDATE STEPS 1;2;[02] UPDATED MEASUREMENT TABLE;[03] UPDATE STEP 3;[04] STEP 3 COMPLETE.;[05] ADDED SUMMARY STATEMENT TO STEP 3.;[06] SUMMARY STATEMENT: INTERCOSTAL OUTSDR SWAA2024041563771Floor Support · crackedCRACKED INTERCOSTAL AT STA 312+8; LBL 46; WL 208.1<[01] UPDATED MEASUREMENTS TABLE;[02] REMOVED AND REPLACED INTERCOSTAL AT BS312-BS328 LBL46; PER SRM 51-40-02 AND DWG#141A5400.;[03] VERIFIED ACTION #2SDR SWAA2024041563782Floor Support · crackedCRACKED INTERCOSTAL AT STA 277+7 AND 277+13; BL 0; WL 208.1<[01] REMOVED AND REPLACED INTERCOSTAL AT BS 277-BS294.5 PER SRM 51-40-02 AND DWG#141A5400.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563795Floorboard · delaminatedDELAMINATION ON 242TF FLOORBOARD AFT WET AREA.<[01] DELAMINATION ON 242TF FLOORBOARD AFT WET AREA WAS REPAIRED IAW SRM 53-00-50-2R-1;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024041563792Floorboard · delaminatedDELAMINATION ON 241AEF FLOORBOARD AFT WET AREA.<[01] FLOOR PANEL 241AEF AFT WET AREA DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563791Floor Panel · delaminatedDELAMINATION ON 241ADF FLOORBOARD AFT WET AREA.<[01] FLOOR PANEL 241ADF AFT WET AREA DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563790Floorboard · delaminatedDELAMINATION ON 241ZF FLOORBOARD AFT WET AREA.<[01] FLOORBOARD 241ZF DELAMINATION DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024041563789Floorboard · delaminatedDELAMINATION ON 241YF FLOORBOARD AFT WET AREA.<[01] IDENTIFIED FLOOR PANEL 241YF IAW SRM 53-00-50-01-1 FIG. 6 TABLE 6 AND FOUND DELAMINATION TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A PARA 4.F. <BR>REPAIR TO BE ACCOMPLISHED PER SRM 53-00-50-2R-1;[02] FLSDR SWAA2024041563788Floor Panel · delaminatedDELAMINATION ON 242RF FLOORBOARD AFT WET AREA.<[01] FLOOR PANEL 242RF WET AREA DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563787Floorboard · delaminatedDELAMINATION ON 241XF FLOORBOARD AFT WET AREA.<[01] 241XF FLOORBOARD AT AFT WET AREA WITH DELAMINATION WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024041563786Door Frame · crackedSTA 312 FRAME INNER RADIUS IS CRACKED ABOVE L1 DOOR CUT-OUT.<[01] REPAIRED CRACK ON BS 312 FRAME STR 6 L ON FAULT ATTACHED TTG8Q00S70JT PER EA M-21-153-01244;[02] CORRECT EA NUMBER IS M-22-153-01244.;[03] VERIFIED TASK COMPLETESDR SWAA2024041563783Support · corrodedCORROSION ON R1 DOOR THRESHOLD SUPPORT FROM STA 294+9 TO 312+13; RBL 58-60; WL 209.<[01] UPDATED P/N;[02] CERTIFY;[03] REMOVED CORROSION ALONG FSD R1 DOOR THRESHOLD SUPPORT AT RBL55; WL208; BS58-60 + 5'; L:1' X W:1' D: 0.013' FROM ORIGINAL THICKNESS IS 0.090' SDR SWAA2024041563780Channel · corrodedCORROSION ON R1 MOP SILL FROM STA 294.5 TO STA 328; RBL 55-61; WL 208 TO 209.<[01] UPDATE TO P/N;[02] CERTIFY;[03] REMOVED AND REPLACED MOP SILL BETWEEN BS 259 TO BS 360; RBL 53;WL 208 PER SRM 51-40-02 AND DWG 141A8310 REV.-.SDR SWAA2024041563779Floor Support · crackedCRACKED INTERCOSTAL AT STA 312+5; RBL 30; STA 208.<[01] UPDATED TABLE;[02] UPDATED STEPS 1-4;[03] REMOVED AND REPLACED INTERCOSTAL PER SRM 51-40-02-0G-0 AND DWG: 141A5400.;[04] UPDATED MEASUREMENTS TABLE.SDR SWAA2024041563777Channel · corrodedCORROSION ON L1 DOOR MOP SILL FROM STA 294.5+16 TO STA 344; LBL 55-61; WL 208.2<[01] UPDATED MEASUREMENT TABLE;[02] UPDATE STEPS 1;2;[03] PARTIAL UPDATE STEP 3;[04] STEP 3 COMPLETE;[05] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024041563784Floorbeam · corrodedCORROSION ON STA 328 FLOOR BEAM AT RBL 20; WL 208.1<[01] BS 328 FLOOR BEAM TO BE REPAIRED ON CARD# TTG8Q00S6FCK.;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2024041563800Shear Web · corrodedCORROSION ON SHEAR WEB AFT WET AREA STA-1016 LBL-3 WL 208.<[01] UPDATED MEASUREMENTS TABLE;[02] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.;[03] UPON FSDR SWAA2024041563801Shear Web · corrodedCORROSION ON SHEAR WEB AFT WET AREA STA-1016 RBL-3 WL 208<[01] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.;[02] UPDATED MEASUREMENTS TABLE.;[03] VERIFISDR SWAA2024041563804Shear Web · corrodedCORROSION ON SHEAR WEB AFT WET AREA STA-1016 LBL-40 APPROX. WL 208<[01] UPON FURTHER INVESTIGATION FOUND PRIMER CHIPPED AND RIVETS DAMAGED AT BS 1006+3 AND 1006+4 AND 1016. CLEANED AREA AROUND THE FASTENERS AT BS 1006+3 AND 1006+4 AND WEB AT BS 1006 PER SRM 51SDR SWAA2024041564063Stiffener · crackedLH HORIZONTAL STAB RIB 4 STIFFENER #4 (AFT) HAS A CRACK.<[01] L/H HORIZONTAL STAB RIB #4 ( STA. 120.3 ) WILL BE REPLACED ON FAULT #TTG8Q00S5BZ7. NO FURTHER ACTION REQUIRED;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024041564262Doubler · crackedDURING REMOVAL R/H VAPOR BARRIER BS 663 FOUND DOUBLER P/N 111A1511-24 CRACKED<[01] REMOVED AND REPLACED IAW SRM 51-40-02 AND DWG 111A1001 REV.- AND DWG 111A1000 REV;;[02] VERIFIED CORRECTIVE ACTION & MEASUREMENTS FIELDS. CARD COMPLETE.SDR SWAA2024041564260Plate · crackedR/W T/E WIGGLE PLATE LOCATED JUST O/B OF PANEL 651DB IS CRACKED<[01] REMOVED AND REPLACED R/W T/E WIGGLE PLATE LOCATED JUST O/B OF PANEL 651DB IAW SRM 51-40-02-0G-0 PARA. 4.;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2024041163995Rib · crackedCRACK ON OUTBOARD LOWER FLANGE INSPAR RIB STAB STA 120.30 FRONT SPAR LT HORIZONTAL STABILIZER. REPAIRED INSPAR RIB STAB STA 120.30 FRONT SPAR LT HORIZONTAL STABILIZER I.A.W B737-700 SRM 55-10-09-2R-5 REPAIR 5 PARAGRAPH 4(N) THRU 4(S) AND B737-700 SRM 51-40-02SDR SWAA2024041164122Stringer · corrodedCORROSION ON STRINGER 28L BTW BS360 TO 380 WL 148.5 AT ELECTRONIC COMPARTMENT. REPAIRED STRINGER 28L LOCATED BTW BS 360 - 380 WL148.5 IAW SRM 53-00-03-2R-1, REPAIR 1.SDR SWAA2024041163993Nut Plate · corrodedCORROSION ON RAIL NUT PLATES INTERNAL CAVITY OF LEADING EDGE OFSS289 RT WING. REPLACED NUT PLATES RAIL LOCATED ON INTERNAL CAVITY OF LEADING EDGE OF SS289 RT WING IAW SRM 51-40-02 AND DWG 112A4402; SHEET: 13 AND REV-.SDR SWAA2024041164121Bracket · damagedELONGATED HOLES ON SUPPORT BRACKET PNEUMATIC DUCT INBOARD LEADING EDGE IFSS151 AT LT WING. REPLACED SUPPORT BRACKET PNEUMATIC DUCT INBOARD LEADING EDGE IFSS151 AT LT WING IAW SRM 51-10-02-0G-0 ITEM 9. & SRM 51-40-02-0G-0.SDR SWAA2024041063996Strap · damagedENGINE #1 UPPER OUTER INLET COWL STRAP P/N 314-2154-2 AT 3 O' CLOCK POSITION #3 HOLE FROM FWD END ELONGATED<[01] REMOVED AND PARTIALLY REPLACED STRAP AT ENGINE #1 UPPER OUTER INLET COWL AS PER SRM 51-40-020G-0 & CMM 71-11-22.;[02] CORRECTION TO STEP #1 <BR>STRSDR SWAA2024040964014Angle · crackedCRACK ON ANGLE LOCATED OUTBOARD AUXILIARY TRACK AT SLAT 1 2024-176928<[01] REPLACED ANGLE LOCATED OUTBOARD AUXILIARY TRACK AT SLAT 1 IAW B737-700 SRM 51-10-02; B737-700 SRM 51-40-02 AND DRAWING 114A5010 SHEET 16 REV A MEASURE OF CRACK IS L:1.506 TOOL USED CALISDR SWAA2024031864980Tray · brokenTRAY TABLE 12C BROKEN WILL NOT STAY UP<[01] RESECURED TRAY TABLE HINGE SCREWS AT ROW 12C IAW CMM 25-23-46. OP CHECK GOOD. THIS CLEARS MEL 25-10-01. PLACARDS REMOVED.SDR SWAA2024031864395Light · missingAFT ISLE PHOTO ILLUMINESCENCE STRIP MISSING (10 INCHES)<[01] R+R PHOTO ILLUMINESCENCE STRIP PER MM 33-51-15SDR SWAA2024031563951Cover · missingAT RIGHT DOOR YELLOW CAUTION COVER FOR SLIDE PULL TO INFLATE HANDLE MISSING. RESECURED R2 DOOR SLIDE CAUTION COVER HOOK AND LOOP IAW AMM INTRO SIPSDR SWAA2024031563936Vapor Barrier · crackedRH WHEEL WELL FWD BULKHEAD VAPOR BARRIER PANEL HAS 2 CRACKS. ONE APPROXIMATELY 2 THE OTHER 4<[01] REPAIRED PER M-21-157-00675-REPREF.SDR SWAA2024042663458Frame · crackedCRACK ON FRAME LOCATED BS 259.5 AT LEVEL STR 9L AT PASSENGER CABIN 2024-195616<[01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60007161486; DUE DATE: 28-JUL-24.;[02] PERFORMED PERMANENT REPAIR LOCATED ON FRAME LOCATED BS 259.5 AT LEVEL STR SDR SWAA2024042663456Rib · crackedCRACK INSPAR RIB 120.30 AT 36 INCHES OF FRONT SPAR AT RT HORIZONTAL STABILIZER 2024-195612<[01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 11-MAR-25.;[02] TOOL UED: EDDY CUREENT EQUIPMENT; PN: NORTEC 600D; SN: 6000716SDR SWAA2024041763744Door · out of adjustFWD ENTRY DOOR IS SAGGING AND CONTACTING UPPER AFT AND LOWER FWD LOWER REVEALS<[01] UPON FURTHER INVESTIGATION FED NEEDED ADJUSTMENT. PERFORMED ADJUSTMENT AND OPC ON FED ON FAULT TTG8Q00S5BF2;[02] VERIFIED CORRECTIVE ACTION STEP 1. TASK CARD COMPLETE.SDR SWAA2024041763214Web · corrodedAFT CARGO BAY SUB-THRESHOLD WEB IS CORRODED FROM STA 787+4 TO STA 827+11; RBL 23-28; WL 156.<[01] REMOVED AND REPLACED SUB-THRESHOLD WEB FROM BS 787 TO BS 847 IAW SRM 51-40-02 AND DWG 146A8340.;[02] VERIFIEDSDR SWAA2024041763208Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM STA 727 TO STA 807+10; LBL 21; WL 156.<[01] REOMVED AND REPLACED ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM BS 727 TO BS 847 LBL 21 IAW SRM 51-40-02 AND DWG 146A7500SDR SWAA2024041763206Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM STA 727 TO STA 807+10; LBL 21; WL 156.<[01] TASK CARD WILL BE COMPLETED ON FAULT TTG8Q00S4HL0;[02] VERIFIED TASK CARD WILL BE COMPLETED ON FAULT TTG8Q00S4HL0;[03] VERIFIED TASK CARD WILL BE COMPLETED ONSDR SWAA2024041763205Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM STA 727B+6 TO STA 767; RBL 21; WL 156.<[01] REMOVED AND REPLACED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM BS 727 TO BS 767 RBL 21 PER SRM 51-40-02 AND DWG 146A7500;[02] VERIFIEDSDR SWAA2024041763203Shield · corrodedCORROSION ON AFT CARGO BAY DOOR FWD SHIELD FROM STA 767 TO 787; RBL 22; WL 156.<[01] REMOVED AND REPLACED ACB AFT SHIELD IAW SRM 51-40-02 AND DWG 146A0081.
Back to Boeing 737-7H4