What was found
CORROSION ON SHEAR WEB AFT WET AREA STA-1016 LBL-3 WL 208.<[01] UPDATED MEASUREMENTS TABLE;[02] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.;[03] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP DGW#147A5600 INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.;[04] UPON FURTHER INVESTIGATION FOUND CORROSION TO BE IN THE STRAP DGW#147A5600 INSTEAD OF SHEAR WEB; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 PARA 9.C.<BR>INSTALLED STRAP AFT WET AREA STA-1016 LBL-3 WL 208 PER SRM 52-40-02-0G-0 AND DWG 147A5600.;[05] REJECT - 2EA SOLID FASTENERS REQUIRE FURTHER FASTENING AT FWD OF STRAP. (MARKED);[06] VERIFIED CORRECTIVE ACTION COMPLETE WITH STEP 1