SDR SWAA2023061243166Access Panel · crackedAFT CARGO COMPARTMENT ACCESS PANEL 141MW EXTERNAL SKIN SURFACE CRACKED.<[01] RESTORED ORIGINAL FINISHED AFT CARGO COMPARMENT ACCESS PANEL 141MW AS PER AMM 25-00-00-370-801.;[02] VERIFIED STEP 1SDR SWAA2023060543508Barrier · crackedCUSTOMER REQUEST CRACK ON VAPOR BARRIER LOCATED AT STA 663 RH SIDE. 2023-299201<[01] TOOL USED: CALIPER P/N: 500-464 S/N: B17030933 DUE DATE: 17/OCT/23.;[02] TOOL USED HOT BONDER P/N: HCS9200B S/N: 15102320 DUE DATE: 22/JAN/24.;[03] TOOL USED: SCALE P/N: CR520SDR SWAA2023060143546Cover · brokenBROKEN EMERGENCY EXIT LIGHT COVER ON HEADER PANEL RH SIDE AT FWD GALLEY AREA (1 EA) 2023-295361<[01] REPLACED EMERGENCY EXIT LIGHT COVER ON HEADER PANEL RH SIDE AT FWD GALLEY AREA (1 EA) IAW B737 AMM 33-51-01-960-802 STEP 3.C (5)(A) AND (7)(10).;[02] TASK CARDSDR SWAA2023060143540Angle · crackedCRACK BRACKET LOCATED AT LEVEL STA 727 AND BETWEEN RBL3.00 AND RBL8.10 AT AFT CARGO COMPARTMENT 2023-295358<[01] REPLACED ANGLE ON AFT CARGO COMP I.A.W SRM B737-700 51-40-02 AND DRAWING 144A2600 REV:-;[02] TASK CARD COMPLETEDSDR SWAA2023060143550Support · corrodedCORROSION CHANNEL SUPPORT FROM STA 767 TO STA 794 AT RBL 21.00 AT AFT CARGO COMPARTMENT 2023-295372<[01] REPLACED CHANNEL SUPPORT AND FASTENER I.A.W SRM B737-700 51-40-02 AND DRAWING 146A0081 REV:A.SEE INDIVIDUAL SIGN OFF BELOW;[02] TASK CARD COMPLETED <BR>REPSDR SWAA2023060143542Floor Support · corrodedCORROSION ANGLE FLOOR STRUCTURE LOCATED BETWEEN BS303.9 TO BS344; WL208.1 AND LBL58 AT FWD GALLEY AREA 2023-295354<[01] REPLACED NEW ANGLE FLOOR STRUCTURE LOCATED BETWEEN BS303.9 TO BS344; WL208.1 AND LBL58 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG SDR SWAA2023053143529Sign · brokenLAV A EXIT SIGN COVER IS BROKEN ON AFT LOWER WALL.<[01] REMOVED AND REPLACED LAV-A EMERGENCY EXIT SIGN ON AFT WALL BY FED PER AMM 33-51-01-960-802; 3.C EXCEPT FOR FOR STEP 3.C.(7); OPERATIONAL TEST.;[02] COMPLETED STEP 1;[03] VERIFIED CORRECTIVE ACTION ITEM 1-SDR SWAA2023053043455Angle · crackedRT WING FIXED TE UPPER PANEL; VERTICAL BULB SEAL RETAINER ANGLE CRACKED; DIRECTLY AFT OF THE PYLON; MARKED.<[01] THERE IS NO SRM ALLOWABLE DAMAGE FOR RT WING FIXED TE UPPER PANEL; VERTICAL BULB SEAL RETAINER ANGLE CRACK. PART TO BE REPAIRED BY REPLACEMENT IAW SDR SWAA2023050443644Cover · out of positionOVERWING EXITG SIGN COVER FELL OFF UPON LANDING<[01] REINSTALLED COVER PER AMM 33-51-01.SDR SWAA2023050443333Battery Pack · inoperativeINTERIOR EMERGENCY LIGHTS OUT AT 23ABC; 22DEF; AND 14ABC<[01] R AND R AFT LEFT BATTERY PACK AND BATTERY PACK CHARGER IAW MM 33-51-06;[02] R/R AFT L/H EMERGENCY LIGHT POWER SUPPLY PER AMM 33-51-06. FOUND WIRES CROSSED AT STA 850 R/H BULLNOSE LIGHT. CONNECTED ANSDR SWAA2023050443304Battery Pack · inoperativeFWD LEFT EMERGENCY LIGHT BATTERY PACK INOP<[01] R&R FWD LEFT EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06. OPS CHECK GOOD.SDR SWAA2023050443449Slide · out of adjustFWD ENTRY DOOR SLIDE COMING OUT ON BOTTOM<[01] PERFORMED GVI OF FWD ENTRY DOOR SLIDE. NO DEFECTS NOTED PER AMM 25-66-00SDR SWAA2023061343152Strip · elongatedAFT CARGO; L/H SIDE CAP STRIPS WITH HOLES ELONGATED<[01] RECEIVED NEW CAP STRIPS P/N 453A2611-4; 453A2611-10; 453A2611-13; NEW CAP STRIPS TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00KS1MU.;[02] VERIFIED FINAL CORRECTIVE ACTION.SDR SWAA2023061343150Strip · elongatedAFT CARGO COMPARTMENT R/H SIDE CAP STRIPS WITH HOLES ELONGATED<[01] RECEIVED NEW AFT CARGO CAP STRIPS P/N 453A2611-9; 453A2611-11 AND 453A 2611-13; NEW CAP STRIPS TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00KS1MU;[02] VERIFIED FINAL CORRECTIVE ACTION.SDR SWAA2023061343153Plate · elongatedLEFT WING REAR SPAR WIGGLE PLATE LOOSE WITH ELONGATED HOLES AT RSS 261.(51-001)<[01] REMOVED AND REPLACED WIGGLE PLATE AT LEFT WING REAR SPAR RSS 261 REF SRM 51-40-02-0G-0;[02] VERIFIED STEP 1SDR SWAA2023060542926Slat · crackedCRACK SLAT 7 LOCATED SLAT STATION 322.71 LOWER SKIN AT RT WING 2023-299144<[01] TOOL USED: EDDY CURRENT EQUIPMENT. P/N: NORTEC 600D. S/N: 210138003. DUE DATE: 27-MAR-24.;[02] PERFORMED PERMANENT REPAIR ON SLAT 7 BTW LEVEL SLAT STATION 313.21 TO SLAT STATION 33SDR SWAA2023060542927Slat · crackedCRACK SLAT 1 LOCATED SLAT STATION 451.97 LOWER SKIN AT LT WING 2023-299150<[01] TOOL USED: NORTEC 500 D; S/N: N500X1693P030456; DUE DATE: 12-MAR-24.;[02] PERFORMED PERMANENT REPAIR ON SLAT 1 BTW LEVEL SLAT STATION 443 TO SLAT STATION 462 LOWER SKIN AT LT WING SDR SWAA2023060143183Light · inoperativeBROKEN PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (10 EA) 2023-295238<[01] REPLACED PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (10 EA) IAW MT 733-50-01 WITH TTG8Q005L765 STEP 4;[02] REPLACED PHOTOLUMINESCENT FLOOR PROXIMITY SDR SWAA2023060143190Stringer Clip · crackedCRACK FRAME ON BS 277 TIE CLIP AT STR10R AT FWD GALLEY AREA 2023-295258<[01] REPLACED TIE CLIP LOCATED ON BS 277 AT STR10R AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02 AND DWG# 141A1110; SHEET 18; REV.-. SEE INDIVIDUAL SIGN OFF BELLOW;[02] CERTIFIED RII WORKSDR SWAA2023060143209Intercostal · crackedCRACK ENTRY DOOR CUT OUT INTERCOSTAL LOCATED BETWEEN BS294.5 TO BS303.9 AND STR16L AT FWD GALLEY AREA 2023-295284<[01] REPLACED INTERCOSTAL WEB AND FASTENERS LOCATED ENTRY DOOR CUT OUT BETWEEN BS294.5 TO BS303.9 AND STR16L AT FWD GALLEY AREA. IAW B737-700 SRM SDR SWAA2023060143206Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TO BS 360 AND RBL 34 FWD GALLEY AREA 2023-295285<[01] REPLACED WEB-INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TO BS 360 AND RBL 34 FWD GALLEY AREA IAW: 51-10-02 AND DWG: 141A5400 SHEET 33 RSDR SWAA2023060143202Scuff Plate · crackedCRACK FWD CORNER SCUFF PLATE AT AFT CARGO COMPARTMENT 2023-295274<[01] TOOL USED DIGITAL CALIPER P/N:500-197-30;S/N:15121570;DUE DATE:05-NOV-23.;[02] REPAIRED BY WELDING FWD CORNER SCUFF PLATE AT AFT CARGO COMPARTMENT I.A.W. BOEING 737-700 SRM 53-60-15-2R-1 RESDR SWAA2023060143196Scuff Plate · crackedCRACK FWD CORNER SCUFF PLATE AT FWD CARGO COMPARTMENT 2023-295270<[01] TOOL USED DIGITAL CALIPER P/N:500-197-30;S/N:15121570;DUE DATE:05-NOV-23.;[02] REPAIRED BY WELDING FWD CORNER SCUFF PLATE AT FWD CARGO COMPARTMENT I.A.W. BOEING 737-700 SRM 53-30-15-2R-1 RESDR SWAA2023060143189Floor Support · crackedCRACK ON FLOOR STRUCTURE INNER CHORD LOCATED BS 303.9 AT LEVEL STR 17L AT FWD GALLEY AREA 2023-295254<[01] REPLACED INNER CHORD LOCATED ON FLOOR STRUCTURE LOCATED ON BS 303.9 AT LEVEL STR 17L AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; DWG 141A8110; SHEET 11SDR SWAA2023060143198Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY AND LAV 2023-295269<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY AND LAV. IAW B737-700 SRM 51-40-02 AND DWG 141A5SDR SWAA2023060143186Scuff Plate · crackedCRACK SCUFF PLATE CENTER POSITION ON FWD SERVICE DOOR AT FWD GALLEY AREA 2023-295245<[01] TOOL USED DIGITAL CALIPER P/N:500-197-30;S/N:B20189515;DUE DATE:19-DEC-23.;[02] TOOL USED RADIOMETER PHOTOMETER PN:XRP-3000; SN: 1753759; DUE DATE: 14-OCT-23;[03] REPAIRESDR SWAA2023060143197Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS328 TO BS344 AND LBL45 FWD GALLEY AND LAV 2023-295272<[01] REPLACED WEB-INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN BS328 TO BS344 AND LBL45 FWD GALLEY AND LAV. IAW B737-700 SRM:51-40-02 AND DWG: 141A54SDR SWAA2023060143199Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND RBL31 FWD GALLEY AND LAV 2023-295266<[01] REPLACED NEW WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND RBL31 FWD GALLEY AND LAV AND FASTENERS IAW B737-700 SRM 51-40SDR SWAA2023060143200Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND RBL31 FWD GALLEY AND LAV 2023-295265<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND RBL31 FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-10-02SDR SWAA2023060143208Support · crackedCRACK BS 294.5 ANGLE - SUPPORT AND STR17R FWD GALLEY AND LAV 2023-295282<[01] REPLACED NEW BS 294.5 ANGLE - SUPPORT AND STR17R FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A8310 SHEE:25 REV- SEE INDIVIDUAL SIGN OFF BELOW;[02] CERTIFIED AS RII <BR>REPLASDR SWAA2023060143210Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS344 TO BS360 AND LBL13 FWD GALLEY AND LAV 2023-295287<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS344 TO BS360 AND LBL13 FWD GALLEY AND LAV IAW SRM B737-700 51-10-02 ITEM 9 AND DRASDR SWAA2023060143257Floor Panel · pulledFLOOR PANEL 231DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 231DF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1525675-1; LOCATED AND INSTALLED ALL INSERTS USING BMS5-107 LOT#AK2KP8383K-1 THEN CURED USING HEAT LAMP AND THERMOMESDR SWAA2023060143258Floor Panel · pulledFLOOR PANEL 231EF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 231EF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION #SDR SWAA2023060143259Floor Panel · pulledFLOOR PANEL 231GF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 231GF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1525675-1; APPLIED TAPE AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 THEN CURED USING HEAT LAMPS AND THERMOSDR SWAA2023060143267Floor Panel · pulledFLOOR PANEL 231JF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 231JF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1525675-1; APPLIED TAPE AND INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 THEN CURED USING HEAT LAMPS AND THERMOSDR SWAA2023060143268Floor Panel · pulledFLOOR PANEL 231UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED NEW FLOOR PANEL 231UF OUT OF BMS 4-23 TY2 LOT#1525675-1. INSTALLED INSERTS USING BMS 5-107 LOT#AK2KP8383K-1 AND CURED UNDER HEAT LAMP USING THERMOMETER ID:ATS2208 DUE:10/23. PART MARKED SDR SWAA2023060143271Floor Panel · pulledFLOOR PANEL 241KF UPPER SKIN HAS ARAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 241KF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 5 TABLE 5. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. DAMAGE TO FLOOR PANEL IS BEYOND ECONOMICAL RSDR SWAA2023060143262Floor Panel · pulledFLOOR PANEL 241SF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 241SF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1525675-1; LOCATED AND INSTALLED ALL INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETSDR SWAA2023060143263Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FABRICATED NEW 241UF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1525675-1; LOCATED AND INSTALLED ALL INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING HEAT LAMP AND THERMOMETSDR SWAA2023060143264Floor Panel · pulledFLOOR PANEL 242MF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] PART/MATERIAL IDENTIFIED PER SRM 53-00-50-0I-1 FIGURE 5 TABLE 5 SECTION 46.UPPER SKIN STRAND DAMAGE EXCEEDS THE ALLOWABLE LIMITS AS GIVEN IN SRM 53-00-50-1A-1. PARA 4. F. <BR>MULTIPLE AREAS OF STRASDR SWAA2023060143201Intercostal · corrodedCORROSION WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS294.5 TO BS312; WL208.1 AND LBL11 FWD GALLEY AND LAV 2023-295271<[01] REPLACED WEB-INTERCOSTAL LOCATED BETWEEN BS294.5 TO BS312; WL208.1 AND LBL11 FWD GALLEY AND LAV. IAW B737-700 SRM: 51-10-02 AND SDR SWAA2023050343407Sign · looseFWD EXIT SIGN COMING LOOSE<[01] RE-ATTACHED FASTNERS ON FWD GALLEY OVERHEAD EXIT SIGN HOUSING PER AMM 33-25-00SDR SWAA2023050343398Light · out of adjustRIGHT OVERWING EXIT SIGN LENS NOT SECURE LOWER EXIT LIGHT LENS TAPED IN PLACE.<[01] C/W EA M-21-133-00720. OK TO CONTINUE ON TLD.SDR SWAA2023050343233Attach Bracket · crackedLEFT WING UPPER ACCESS PANEL INBD FWD SUPPORT ATTACH BRACKET (Z BRACKET) CRACKED.<[01] R&R LEFT WING UPPER ACCESS PANEL INBD FWD SUPPORT ATTACH BRACKET (Z BRACKET) IN REF TO SOPM 20-50-18.SDR SWAA2023050343419Slide · out of positionSLIDE ON MAIN CABIN DOOR (L1) DISPLACED FROM CONTAINER<[01] R&R FE ESCAPE SLIDE PER AMM 25-66-01 AND MT725-61-06SDR SWAA2023050343290Light · inoperativeROW 16DEF AND 18DEF EMERGENCY AISLE LIGHTS INOP<[01] SLAVED IN AFT R/H EMERGENCY NEW POWER PACK AND NEW BATTERY PER AMM 33-51-06. NO FIX.;[02] REF WDM 33-51-14 FOUND HOUSING ASSY AT ROW 16 SHORTED INTERNALLY CAUSING FUSE IN CHARGER M1672 TO BLOW. REF AMM 33-51SDR SWAA2023050343293Light · inoperativeAFT ENTRY/SLIDE EMERGENCY LIGHT INOP.<[01] RELAMPED AFT ENTRY/SLIDE EMERGENCY LIGHT IAW AMM 33-51-04. OPS CHECK GOOD.SDR SWAA2023050343316Panel · elongatedPANEL 193B HAS SEVERAL ELONGATED; OVERSIZED FASTENER HOLES AND DAMAGED COUNTERSINKS.<[01] LOCATED HOLES IN NEW PANEL PER SRM 51-40-05;[02] REMOVED AND REPLACED 193BB PANEL PER AMM 53-51-21SDR SWAA2023061342523Panel · elongatedCENTER WHEEL WELL ACCESS PANEL 193D LOWER SKIN SURFACE HAS FASTENER HOLE ELONGATED.<[01] REPAIRED ACCESS PANEL #193D AS PER B737 SRM 51-70-04-2R-9; MATERIAL USED RESIN PO#1800550 AND CLOTH PO#1738579.;[02] VERIFIED STEP 2;[03] CORRECTION: VERIFIED STEP 1SDR SWAA2023061343145Panel · elongatedACCESS PANEL 193B HAS ENLONGATED HOLES (COMPOSITE AREA)<[01] APPLIED REPAIR ON DAMAGED AREA AT ACCESS PANEL#193B AS PER B737 SRM 51-70-04-2R-9. MATERIAL USED RESIN PO#1800550 AND CAB PO#1776837 AND CLOTH PO#1738579 AND APPLIED TOPCOAT TO ACCESS PANEL 193B PER
Back to Boeing 737-7H4