SDR SWAA2023061343135Vapor Barrier · crackedFOUND LT SIDE STA 663 VAPOR BARRIER CRACKED<[01] FINAL;[02] REPAIRED CRACK DAMAGE ON L/H VAPOR BARRIER WITH A PERMANENT REPAIR AS PER B737 SRM 51-70-04-2R-10. MATERIAL USED PO#1800550 AND PO#1738579SDR SWAA2023061342526Panel · crackedL/H WING T/E ACCESS PANEL 561AB INTERNAL SKIN SURFACE HAS CRACKS AROUND MULTIPLE FASTENER HOLES.<[01] MEASUREMENT;[02] CLEANED AND PREPARED AREA AT L/H WING ACCESS PANEL 561AB; REPAIRED DAMAGE AREAS AT L/W ACCESS PANEL #561AB AS PER SRM 51-70-04-2R-9 .MATERIALSDR SWAA2023061342527Panel · crackedL/H WING T/E ACCESS PANEL 561CB INTERNAL SKIN SURFACE HAS CRACKS AROUND MULTIPLE FASTENER HOLES.<[01] APPLIED REPAIR ON DAMAGED AREA AT ACCESS PANEL #561CB AS PER B737 SRM 51-70-04-2R-9; MATERIAL USED CAB PO# 1776837 AND RESIN PO#1800550 AND CLOTH PO#1738579.;SDR SWAA2023061343149Panel · crackedL/H WING T/E ACCESS PANEL 561BB INTERNAL SKIN SURFACE HAS CRACKS AT MULTIPLE FASTENER HOLES.<[01] REPARED ACCESS PANEL #561BB AS PER B737 SRM 51-70-04-2R-9; MATERIAL USED RESIN PO#1800550 AND CLOTH PO#1738579.;[02] VERIFIED STEP 1SDR SWAA2023060143175Girt Bar · out of adjustDETERIORATED GIRT BAR FITTING HARDWARE AT FWD GALLEY AREA 2023-295225<[01] REPLACED GIRT BAR FITTING HARDWARE AT FWD GALLEY AREA I.A.W. B737-700 AMM 25-66-02-400-801 STEP 3 D (1) (G)(H)(I);[02] REPLACED GIRT BAR FITTING HARDWARE AT FWD GALLEY AREA I.A.W. B737-SDR SWAA2023060143181Angle · crackedCRACK SERVICE DOOR CUT OUT ANGLE LOCATED BETWEEN BS294.5 AND STR8R TO STR10R AT FWD GALLEY AREA 2023-295233<[01] REPLACED ANGLE AND FASTENER I.A.W SRM B737-700 51-40-032 AND DRAWING 141A8370 REV:D LOC BS294.5 AND BTW S-8R TO S-10R . SEE INDIVIDUAL STEP SIGN OFSDR SWAA2023060143182Floorbeam · crackedCRACK FLOOR STRUCTURE BEAM LOCATED BETWEEN BS294.5 AND RBL51 AT FWD GALLEY AREA 2023-295235<[01] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC500D; S/N: N500X12101V022240; CAL DUE DATE: 12-MAR-24;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/SDR SWAA2023060142663Floor Panel · crackedFWD FLOOR PANEL 221BF O/B TANG IS CRACKED.<[01] IDENTIFIED PANEL 221BF IAW SRM 53-00-50-0I-1 FIG 2; TABLE 2 FOUND CRACKE ALONG BOTH UPPER AND LOWER SKINS OF TANG TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F.<BR><BR>COMPLETELY REMOVED TANG; PRESDR SWAA2023060142675Floor Panel · pulledAFT FLOOR PANEL 241YF UPPER SKIN HAS AN AREA OF PULLED STRANDS.<[01] IDENTIFIED FLOORBOARD MATERIAL IAW SRM 53-00-50-0I-1 SHEET 1 FIG 6 TABLE 6<BR><BR>PANEL UPPER SKIN DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR 4.F.<BR><BR>PANEL SKIN DASDR SWAA2023060142672Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] IDENTIFIED PANEL 241AAF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6. DAMAGE TO UPPER SURFACE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. FLOOR PANEL 241AASDR SWAA2023060142677Skin · pulledAFT FLOOR PANEL 242UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 242UF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6.<BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. <BR><BR>DAMAGE IS REPAIRABLE IAWSDR SWAA2023060143179Floorbeam · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BETWEEN BS986.5; WL208.1 AND RBL44 AT AFT GALLEY AREA 2023-295231<[01] EQUIPMENT P/N 45MG; S/N 130063701; DUE DATE 16-JUN-23 WAS USED.;[02] TOOL USED PN:38DL PLUS; SN:120398603; DUE DATE:07-NOV-23;[03] TOOL USED EDDY CURRSDR SWAA2023060143253Support · corrodedMULTIPLE AREAS OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727+5-807 WL 155-157.<[01] VERIFIED APPLICABILITY SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY FLOSDR SWAA2023060143254Support · corrodedMULTIPLE AREAS OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727C-767 WL 154-155.<[01] VERIFIED APPLICABILITY SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORTSDR SWAA2023060143255Shield · corrodedMULTIPLE AREAS OF CORROSION ON AFT CARGO BAY FWD DOOR SHIELD AT RBL 21 BS 767-787+5 WL 155.<[01] NO ALLOWABLE DAMAGE LIMITS IN SRM. REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PARAGRAPH # 9;[02] VERIFIED CORRECTION ACTION ITEM 1.;[03] RECEIVED NEW SHIELD PSDR SWAA2023060143256Threshold · corrodedMULTIPLE AREAS OF CORROSION ON AFT CARGO BAY THRESHOLD AT RBL 21-27 BS 787+8-847 WL 156.<[01] VERIFIED APLICABILITY FOR IDENTIFICATION<BR>IAW SRM 53-60-15-01-1<BR>AND SRM 53-60-15-1A-1 FOR ALLOWABLE DAMAGE<BR><BR>REMOVED CORROSION ON AFT CARGO BAY THRESHOLD<BRSDR SWAA2023053142519Gusset · crackedFORWARD CARGO BAY GUSSET AT BS 500D STRINGER 19 R/H IS CRACKED<[01] REMOVED CARGO BAY R/H GUSSET AT BS 500D STR 19 PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW GUSSET BS 500D STR 19R PER SRM 51-40-05-0G-0 AND DWG 143A7902. OK TO INSTALL GUSSET;[03] VERIFSDR SWAA2023053143125Angle · corrodedCORROSION AFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS MULTIPLE AREAS UNDER NUT PLATES BS767 TO BS787 RBL21 WL156<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED DAMAGEDSDR SWAA2023053143126Shield · corrodedCORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767 TO BS794 RBL22 WL156<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED DAMAGE AFT SDR SWAA2023053042815Stringer · crackedMAIN DISTRIBUTION BAY CRACK ON END OF STR 26R BS 540<REMOVED DAMAGED SECTION OF STRINGER 26R BS 500D+11'-540 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B.;[04] PERFORMED GVI ON REPAIR AREA AND NO ADDITIONAL DAMAGED FOUND IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B(1).;[05]SDR SWAA2023052542812Stringer · crackedMAIN DISTRIBUTION BAY CRACK ON END OF STR 26L BS 540<[01] UPDATED MEASURING TABLE. REMOVED DAMAGED SECTION OF STRINGER 26L BS 500D+11'-540 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B. PERFORMED GVI ON REPAIR AREA AND NO ADDITIONAL DAMAGED FOUND IAW SRM 53-00-03-2SDR SWAA2023052542814Stringer · crackedMAIN DISTRIBUTION BAY CRACK ON END OF STR 23R BS 540. PERFORMED GVI ON REPAIR AREA AND NO ADDITIONAL DAMAGE FOUND IAW EA 23-153-01413 AND SRM 53-00-03-2R-1 REP.1 PAR 4 B(1). INSTALLED ALL FASTENERS COMMON TO SKIN AND STRINGER SECTION STR-23R BS 500D+11'-54SDR SWAA2023052542829Fitting · looseAFT SERVICE DOOR FWD GIRT BAR FITTING LOOSE.<[01] REMOVED CLEANED & REINSTALLED FT SERVICE DOOR FWD GIRT BAR FITTING TORQUED TO SPEC PER AMM 25-66-02-400-801; 25-66-02-000-801; 20-50-11-910-801.<BR>OPS CHECK GOOD.;[02] REMOVED CLEANED & REINSTALLED AFT SERVICESDR SWAA2023052542475Web · crackedCRACK ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; LBL 33; WL 202.5. APPROXIMATE LENGTH: 1.5'<[01] DAMAGE FOUND ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; LBL 33; WL 202.5 TO BE REPAIRED IN TTG8Q00KQ86N I.A.W SRM 53-40-51-2R-2 REPAIR 2;[02] VERIFIED CORRECSDR SWAA2023052542477Web · crackedCRACK ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; RBL 40; WL 202.5. APPROXIMATE LENGTH: .75'<[01] DAMAGE FOUND ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; RBL 40; WL 202.5. TO BE REPAIRED IN TTG8Q00KQ8UG I.A.W SRM 53-40-51-2R-2 REPAIR 2;[02] VERIFIED CORRESDR SWAA2023052542478Web · crackedCRACK ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; RBL 42.5; WL 202.5. APPROXIMATE LENGTH: .5'<[01] DAMAGE FOUND ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; RBL 42.5; WL 202.5. TO BE REPAIRED IN TTG8Q00KQ8UG I.A.W SRM 53-40-51-2R-2 REPAIR 2;[02] VERIFIED COSDR SWAA2023052542479Web · crackedCRACK ON HORIZONTAL PRESSURE DECK WEB AT STA 663+9.5; RBL 41; WL 202.5. APPROXIMATE LENGTH: .75'<[01] HORIZONTAL PRESSURE DECK WEB AT 663+9.5; RBL41; WL202.5 FOUND TO BE OUT LIMITS AND WILL BE REPAIR IAW SRM 53-40-51-2R-2. VERIFIED SRM 53-40-51-2R-2 IS APPLICASDR SWAA2023052542476Web · crackedCRACK ON HORIZONTAL PRESSURE DECK WEB AT STA 663+2; LBL 37.5; WL 202.5. APPROXIMATE LENGTH: .85'<[01] UPDATED MEASUREMENTS. HORIZONTAL PRESSURE DECK WEB AT 663+2; LBL37.5; WL202.5 FOUND TO BE OUT LIMITS AND WILL BE REPAIR IAW SRM 53-40-51-2R-2. VERIFIED SRM 53SDR SWAA2023052542482Stringer · crackedCRACK ON STRINGER S-23L TERMINUS. STA 540<[01] UPDATED MEASUREMENT TABLE.[08] RECEIVED NEW STRINGER SECTION S-23L FROM OSS RO. 917127-SWA-3 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4D AND EA 23-153-01405.;[09] VERIFIED CORRECTIVE ACTION 8.;[10] RECEIVED STRINGER SPLISDR SWAA2023052542487Stringer · crackedCRACK ON STRINGER S-25R TERMINUS. STA 540<[01] UPDATED MEASUREMENT TABLE AND STEP 1.;[02] VERIFIED CORRECTIVE ACTION 1.;[03] ACCOMPLISHED HFEC SURFACE SCAN OF CUT EDGE IAW 737 NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 23. NO CRACKS NOTED.<BR><BR>ACCOMPLISHED HFECSDR SWAA2023052542483Stringer · crackedCRACK ON STRINGER S-24L TERMINUS. STA 540<[01] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1 REP.1 AND UPDATED OF MEASUREMENT TABLE.;[02] REMOVED DAMAGED SECTION OF STRINGER 26L BS 500D+11'-540 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B.;09/2023;[07] RECEIVED NEW STRSDR SWAA2023052542484Stringer · crackedCRACK ON STRINGER S-25L TERMINUS. STA 540<[01] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1 REP.1.;[02] REMOVED DAMAGED SECTION OF STRINGER 25L BS 500D+11'-540 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B.;[03] PERFORMED GVI ON REPAIR AREA AND NO ADDITIONAL DAMAGED FOSDR SWAA2023051142918Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221DF FOUND DELAMINATED: P/N 141A5810-59<[01] RECEIVED MAIN CABIN FLOOR PANEL 221DF P/N 141A5810-59; PANEL WILL BE INSTALLED ON T/C TTG8Q00JCQTE;[02] VERIFIED STEP 1SDR SWAA2023050243353Slide · failedAFT ENTRY DOOR SLIDE BOX OPENED WHILE PROVO WAS ENTERING SLIDE DID NOT DEPLOY<[01] REINSTALLED EMER EXIT SLIDE TO AFT ENTRY DOOR AMM 25-66-01SDR SWAA2023050242627Light · inoperativeRH OVER WING EXIT SIDEWALL LIGHT OUT<[01] REMOVED AND REPLACED WINDOW LIGHT AT RH OVERWING EXIT IAW AMM 33-21-00.SDR SWAA2023050242692Light · inoperativeR2 DOOR EXTERIOR EMERGENCY EXIT LIGHT INOP<[01] RELUMPED R2 DOOR EXTERIOR EMERGENCY EXIT LIGHT PER AMM 33-51-04. OPS CHECKED GOODSDR SWAA2023050243366Handle · brokenFWD SERVICE DOOR ASSIST HANDLE IS BROKEN<[01] R & R FWD SERVICE DOOR ASSIST HANDLE IAW AMM 52-41-31SDR SWAA2023050143371Slide · looseL1 DOOR SLIDE FELL OUT OF CONTAINER<[01] REINSTALLED L1 DOOR SLIDE IN CONTAINER IAW MT 725-61-06.SDR SWAA2023061242235Girt Bar · out of adjustL2 DOOR SLIDE GIRT Z FOLD DRAGGING AT DOOR LOWER CUT OUT.<[01] ACCOMPLISHED AFT ENTRY DOOR ESCAPE SLIDE REPOSITIONING OF GIRT; REF SOUTHWEST MT 725-61-06; GENERAL NOTES 1.C.;[02] VERIFIED STEP 1SDR SWAA2023061242234Slide · out of adjustR2 DOOR SLIDE GIRT Z FOLD DRAGGING AT DOOR LOWER CUT OUT.<[01] ACCOMPLISHED AFT ENTRY DOOR ESCAPE SLIDE REPOSITIONING OF GIRT REF SOUTHWEST MT 725-61-06 GENERAL NOTES 1.C.;[02] VERIFIED STEP 1SDR SWAA2023060142228Panel · crackedCRACKED BREAK PANEL STA 540; BL0-LBL 25; WL 208.<[01] UPDATED MEASUREMENT TABLE;[02] LOCATED AND DRILLED NEW BREAK PANEL AT STA 540; BL 0 - LBL 25; WL 208 IAW SRM 51-40-05-0G-0 AND AIPC 53-42-11-66. OK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION 2<BR>OK TO INSTSDR SWAA2023060142230Angle · crackedCRACKED ANGLE COMMON TO CABLE GUARD INTERCOSTAL STA 694; RBL 24; WL 203. (MARKED).<[01] REMOVED AGLE AT BS 694; RBL 24;WL 203 IAW SRM 51-40-02<BR><BR>CRACK ON ANGLE IT'S OUT OF LIMITS WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[02] FABRICASDR SWAA2023060142649Intercostal · crackedCRACK ON PASSENGER CABIN INTERCOSTAL AT BL 0 BS 277+8 WL 208.<[01] REMOVED INTERCOSTAL PER SRM 51-40-05 LOCATED AND DRILLED NEW P/N 141A5410U3AAR PER DWG #141A5410-3 OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION ITEM 1; OK TO INSTALL.;[03] PARTIAL INSTALLED INSDR SWAA2023060142247Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOC BTW STA 685 TO STA 706 RBL 0 AT PASSENGER CABIN 2023-295171<[01] REPLACED NEW ANGLE FLOOR STRUCTURE LOC BTW STA 685 TO STA 706 RBL 0 AT PASSENGER CABIN IAW B737-700 SRM 51-40-02 AND DWG 273A9110 SHEET:6 REV:-SEE INDIVIDUAL SIGN SDR SWAA2023060142650Fitting · corrodedCORROSION ON PASSENGER CABIN L/H FITTING AT LBL 59 BS 344 WL 208.<[01] FOUND NO ALLOWABLE LIMITS ON IAW SRM 53-10-15-1A-1;[02] FOUND NO ALLOWABLE LIMITS ON IAW SRM 53-10-51-1A-1;[03] REMOVED FITTING PER B737-700 SRM 51-40-02;[04] VERIFIED CORRECTIVE ACTION ITESDR SWAA2023060142658Strap · corrodedCORROSION ON PASSENGER CABIN FLOOR STRAP AT RBL 18 BS 1016+12 WL 208.<[01] REMOVED CORROSION ON FLOOR STRAP IAW SRM 51-10-02-0G-0; MEASURES L=1.020'' X W=0.825'' ORIGINAL THICKNESS=0.050'' PER DWG# 147A5744; TOOL USED CALIPER ID: ATS2739 S/N:A22004232 DUE DATESDR SWAA2023053142229Crease Beam · corrodedCORROSION ON CREASEBEAM INNER CHORD STA 685-727; RBL 65; WL 208.<[01] SRM 53-40-13-1A-1 IS APPLICABLE ALLOWABLE DAMAGE; UPDATED TABLE.;[02] UPDATED P/N IN MEASUREMENTS TABLE;[03] REMOVED 21 EA FASTENERS FOR ACCESS ON CREASEBEAM INNER CHORD STA 685-727; RBL 65;SDR SWAA2023052442214Baffle · crackedATTACH CLIP COMMON TO BAFFLE IS CRACKED; BS 400 LBL 20 WL 156; AFT SIDE OF BS 400 FRAME<[01] REMOVED CLIP LOCATED ON BS.400; FRAME; AFTER SIDE IAW SRM 51-40-02.;[02] RECEIVED CLIP WITH P/N 143A7502-155. LOT: 1519478-4.<BR>LOCATED AND DRILLED NEW CLIP IAW SRM 5SDR SWAA2023051142219Intercostal · crackedFOUND INTERCOSTAL CRACKED AT MAIN CABIN FLOOR AREA LBL 13.24; BETWEEN STA. 380 & STA. 400.<[01] REMOVED AND REPLACED UPPER CHORD ON INTERCOSTAL AT MAIN CABIN FLOOR AREA LBL 13.24 BETWEEN STA 380 AND STA 400 AS PER B737-700 SRM 51-40-02-0G-0 AND DWG 143A5400.;[SDR SWAA2023051142218Intercostal · crackedFOUND INTERCOSTAL CRACKED AT MAIN CABIN FLOOR AREA BL 0; BETWEEN STA. 380 & 400.<[01] REMOVED AND REPLACED ANGLE AT BL 0; BETWEEN STA 380 & STA 400 REF. 737-700-SRM 51-40-02-0G-0 AND DWG 143A5400.;[02] VERIFIED STEP 1;[03] VERIFIED WORK COMPLETED
Back to Boeing 737-7H4