SDR CALA2016042800262Unknown · malfunctionedLEFT ENG ACCELERATED RAPIDLY ON TAKEOFF ROLL, IDLE THRUST DISCONTINUED TAKEOFF. PERFORMED FIM TASK 73-00-00-810-801-FOO, EEC BITE PROCEDURE, NO FAULTS FOUND PERFORMED HIGH POWER ENG RUN NO FAULTS ACFT OK TO CONTINUE.SDR CALA2016042600251Door Frame · crackedR1 DOOR STUB FRAME ASSEMBLY CRACKED AT APPROX STATION 296, WL 210. R & R R1 DOOR STUB FRAME IAW SRM 51-40-02, PN 141A8371U8.SDR CALA2016042500250Floorbeam · corrodedCABIN FLOOR STRUCTURE FLOORBEAM STATION 328 AT RBL 12 SHOWS SIGNS OF CORROSION. INSTALLED UPPER CHORD FLOORBEAM REPAIR IAW SRM 53-10-51 REPAIR 7 ALTERNATIVE 2.SDR CALA2016042500246Reminder · smokeDURING TAXI IN, SMOKE COMING FROM FIRST OFFICERS YOKE FLIGHT NR WHEEL. TURNED OFF RHEOSTAT. SMOKE STOPPED TRACED DOWN TO BAD REMINDER ASSEMBLY ON FIRST OFFICERS YOKE. REPLACED REMINDER ASSEMBLY IAW MM 33-11-00 & IPC REF 33-11-51-04. REPLACED CAPTAINS REMINSDR CALA2016042200243Battery Pack · failedSUPPORT TASK, EMER LIGHT BATTERY PACK M1574 FAILS CAPACITY CHECK. R & R M1674 BATTERY PACK IAW AMM 33-51-06. BATTERY CAPACITY CHECK GOOD IAW AMM 33-51-06, M1674 LOCATION, STATION 322, WL 291, RBL 7, CONNECTOR D10748.SDR CALA2016042200244Warning System · false activationAPU SHUTDOWN IN FLIGHT DUE TO AMBER LOW OIL PRESS LIGHT. TROUBLE SHOT IAW FIM 49-90-10. BITE SHOWS FAULT 49-91007. CHECKED APU OIL AT CDU, SHOWS FULL. PHYSICALLY CHECKED APU OIL SIGHT GLASS, JUST ABOVE ADD. ADDED OIL IAW AMM 12-13-31. INSPECTED MAG CHIP,SDR CALA2016042100238Frame · dentedFORWARD CARGO LT FRAME STATION 500E, JUST ABOVE SIDE PLATE THE FRAME IS SEVERELY DENTED ON TOP SIDE. IAW ECRA 5310-06802 COMPLIED WITH PART 1 INTERIM REPAIR. ITEM PLACED ON DIP IAW PART 1 STEP 17 OF ECRA 5310-06802.SDR CALA2016042100237Floorbeam · corrodedFORWARD ENTRY FLOORBEAM HAS CORROSION ON TOP SURFACE LOCATED AT BS 328 & RBL 0 - RBL 55, LOCATION IS APPROX. REMOVED DAMAGED SECTION OF UPPER FLOORBEAM CHORD. FABRICATED & INSTALLED UPPER T CHORD REPAIR IAW ECRA 5321-01930.SDR CALA2016042100236Floorbeam · corrodedFORWARD ENTRY FLOORBEAM HAS CORROSION ON TOP SURFACE LOCATED AT STATION 344 & BL 0. INSTALLED UPPER FLOORBEAM CHORD REPAIR IAW ECRA 5321-01929.SDR CALA2016042100235Bulkhead · crackedONE INCH CRACK FOUND IN WEB OF RT WW FWD BULKHEAD LOCATED BETWEEN RBL 31.83 & RBL 40.00 & WL 200.6 - 192.0. INSTALLED CATEGORY B REPAIR AT RT VERTICAL PRESS DECK IAW SRM 57-10-10 REPAIR 3 ALT 1 PARA 4 FIG 203.SDR CALA2016042100234Skin · crackedLEFT HORIZONTAL STAB EXTERIOR LOWER SKIN CRACKED AT STATION 101.90, 11" FWD OF REAR SPAR. PAINTED REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11 STEP 4.O. FLIGHT TEST NOT NECESSARY IAW SRM 55-10-01 REPAIR 11 STEP 4 P PGH 1 H. DIP INITIATED IAW SRM 55-10-01 REP 1SDR CALA2016041800230Skin · crackedCRACK INDICATION ON LT HORIZONTAL STABILIZER LOWER SKIN AT STATION 157.10 AT APPROX 9.5 INCHES FROM REAR SPAR. REMOVED DAMAGE & INSTALLED EXTERNAL REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11.SDR CALA2016041800229Skin · crackedCRACK INDICATION ON RT HORIZONTAL STABILIZER LOWER SKIN, AT STATION 101.90, AT APPROX 11.5 INCHES FROM REAR SPAR. REMOVED DAMAGE & INSTALLED EXTERNAL REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11. DIP INITIATED TO INSPECT REPAIR AT INITIAL THRESHOLD OF 56,000 TOSDR CALA2016041800228Bulkhead · cracked2" CRACK FOUND IN WEB OF LT WW FWD BULKHEAD, LOCATED BETWEEN LBL 40.00 - 45.64 & WL 200.6 - 192.0. INSTALLED CATEGORY B REPAIR AT WING CTR SECTION REAR SPAR VERTICAL PRESS DECK LT SIDE IAW SRM 57-10-10 REPAIR 3 ALTERNATIVE 2 PARAGRAPH 5 FIGURE 204.SDR CALA2016041100218Skin · crackedRIGHT HORIZONTAL LOWER SKIN, STABILIZER STATION 129.5 HAS A 1.0 INCH CRACK, 17.50 INCHES FROM TE. REF EA 5510-01843 REV E. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016041100217Skin · crackedRIGHT HORIZONTAL LOWER SKIN, STABILIZER STATION 138.70, HAS A 0.50 INCH CRACK, 16.50 INCHES FROM LE. REF EA 5510-01843 REV E. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016040700214Skin · crackedLEFT HORIZONTAL LOWER SKIN STAB STATION 129.5 HAS A 0.25 INCH CRACK, 10.50 INCHES FROM TE REF EA 5510-01843 REV E. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016040400212Sensor · defectiveAFTER TAKEOFF HAD FLAPS LE, FLAP TRANSIT LIGHT REMAIN ON WITH THE FLAPS UP. NR 1 SLAT SHOWED STILL IN THE FULLY EXTENDED POSITION. DID CHECKLIST & RETURNED. FOUND SENSOR S994 BAD. REPLACED SENSOR IAW MM 27-88-11. SYS GND CHECKED GOOD.SDR CALA2016033100203Skin · not reportedINSTALL DOUBLER REPAIR IAW STEPS 14 - 15. INSTALLED DOUBLER IAW AVO4991 STEPS 14 PARA 15.SDR CALA2016032900196Proximity Sensor · faultyAT FL 380 LE FLAP TRANSIT LIGHT ILLUMINATED. AFTER CONDUCTING QRH & DESCENDING TO FL 200, THE LIGHT FLICKERED ON & OFF UNTIL LEVEL AT FL 200. LIGHT EXTINGUISHED AT FL 200. REPLACED S1006 IAW MM 27-88-11.SDR CALA2016032900194Skin · crackedRIGHT HORIZONTAL STABILIZER, LOWER INSPAR SKIN HAS A CRACK, AT STAB STATION 129.5, 34" AFT OF THE LE SPAR. INSTALLED REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11.SDR CALA2016032800192Skin · crackedRIGHT HORIZONTAL LOWER INSPAR SKIN HAS A CRACK AT STAB STATION 147.9 8, 5" AFT OF LE SPAR. INSTALLED REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11.SDR CALA2016032800191Skin · corrodedCORROSION AT STATION 500+10, ON BELLY OF ACFT, REFER TO LOG PAGE 9090297 & 9090298. ACCOMPLISHED INTERIM REPAIR IAW ECRA 5331-02088 PART 1. DIP ISSUED TO ACCOMPLISH A PERMANENT REPAIR ON OR BEFORE MARCH 23 2017. PLANNING TO CONTACT ENGINEERING AFTER JANUARYSDR CALA2016032800188Beam · crackedPLEASE COMPLY WITH ECRA 5210-02705. ACFT 0268, R1 DOOR BEAM CRACK INSPECTION & REPAIR R & R R1 DOOR LOWER DOOR BEAM IAW SRM 51-40-02 & DWG 141A6516.SDR CALA2016032800187Skin · dentedDENT IN RT FWD FUSELAGE, 14" FWD OF GND POWER RECEPTACLE CUT OUT, AT STATION 215. REPAIRED DENT IAW SRM 53-00-01 REPAIR 3.SDR CALA2016032400184Charger · defectiveWHILE TROUBLESHOOTING EMER EXIT LIGHTS, BURNT 2 EA CHARGER ASSEMBLY. R & R M1695 RT FWD OVERWING EXIT BATTERY PACK CHARGER IAW AMM 33-51-06. NOW OPERATIONS CHECKED GOOD.SDR CALA2016032100175Battery Pack · dischargedSUPPORT TASK, EMER LIGHTS INOPERATIVE AT FWD ENTRY WAY. REMOVED & INSTALLED SERVICEABLE BATTERY PACK IAW AMM 33-51-06-960-805 & TESTED GOOD.SDR CALA2016031700167Floorbeam · corrodedCABIN FLOORBEAM AT STATION 328, RBL 10 - 13, HAS CORROSION ON TOP SURFACE & FWD LE. REPAIRED FLOORBEAM IAW SRM 53-00-51 REPAIR 11.SDR CALA2016031400163Actuator · leakingRIGHT MLG RETRACT ACTUATOR LEAKING AT CYLINDER HOUSING. REPLACED RT MLG RETRACT ACTUATOR IAW AMM 32-32-11-400- 801. OPERATIONS & LEAK CHECKED GOOD. ROTABLE PARTS CHANGE WAS INDICATED. TT 1885502, SN OFF 05830, ACTUATOR, MLG, OFF 29-3211-9-0001 5830 ON 29-3SDR CALA2016031400162Wire Harness · defectiveDURING CLIMB OUT, PASSING 15,000 FT NR 1 ENG OVERHEAT LIGHT ILLUMINATED IAW QRH. REDUCED THRUST LIGHT WENT OUT. DECLARED EMER & PERFORMED OVERWEIGHT LANDING AFTER REPLACEMENT OF NR 1 ENG B LOOP HARNESS & CLEAR FIRST OFFICERS MEL ITEM 2602C. PERFORMED 4 MIN.SDR CALA2016031400161Wire Harness · shortNUMBER 1 FIRE HANDLE FAILED TEST B LOOP SHORTED, A OK PLACED ON MEL, FOUND SHORTED WIRE HARNESS MW0326. R & R IAW AMM 26-11 -02-000-802. CHECKED OK IAW AMM 26-11-00-710-801.SDR CALA2016031100160Skin · not reportedECRA 5331-02078 REPAIR TO FUSELAGE SKIN, BS 907 - 927, BETWEEN STRINGER -20L & -23L.SDR CALA2016031100158Skin · crackedLEFT HORIZONTAL LOWER SKIN, AT STATION 147.90, 18" FWD OF REAR SPAR HAS A CRACK. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016030300142Power Supply · inoperativeEMERGENCY EXIT LIGHTS ROWS 23 - 31 INOPERATIVE. REPLACED LT MID-SECTION BATTERY SUPPLY & BATTERY AT STATION 727 IAW MM 33-51-06 & TESTED OK.SDR CALA2016030300141Skin · crackedLEFT HORIZONTAL STAB CRACK AT STATION 138.70, 19" FWD OF AFT SPAR. REPAIRED IAW SRM 55-10-01 REPAIR 11.SDR CALA2016030300140Skin · crackedLEFT HORIZONTAL STAB CRACKED AT STATION 138.70, 8" AFT OF FWD SPAR. REPAIRED IAW SRM 55-10-0 REPAIR 11.SDR CALA2016030300139Skin · crackedLEFT HORIZONTAL STAB FOUND A CRACK AT STATION 129.50, 6" AFT OF REAR SPAR. REPAIRED IAW SRM 55-10-01 REPAIR 11. INITIATED A DIP TO PERFORM INSPECTION IAW SRM 55-10-01 REPAIR 11 STEP 5 TABLE 204.SDR CALA2016030300138Switch · defectiveAFTER TAKEOFF & RAISING GEAR HANDLE, ALL 3 GEAR WOULD NOT COME UP. INDICATION WAS 3 GREEN & 3 RED WITH HANDLE IN UP POSITION. RAN CHECKLIST, NO HELP. PUT HANDLE DOWN, REDUCED WEIGHT & LANDED. TROUBLE SHOT IAW FIM 32-30-00-810-815, FOUND MANUAL DOOR EXTENSISDR CALA2016021900119Bracket · misinstalledPREVIOUS INFLIGHT CREW NOTICED THAT GIRT BAR BRACKETS IN FLOOR ON BOTH FWD ENTRY DOORS ARE 180 DIFFERENT DIRECTION FROM BOTH AFT DOORS. R & R ALL FOUR FLOOR BRACKETS IAW 25-66-02-400-801, FOR BOTH DOORS. ALL OPERATIONS CHECKED GOOD.SDR CALA2016021900118Light · inoperativeSUPPORT TASK, LT AFT OVERWING EMER SLIDE LIGHT INOPERATIVE, UPON INBOUND. R & R LAMP, PN GE767, AT LT OVERWING EMER SLIDE LIGHT IAW AMM 33-51-04. THE LIGHT TESTED OK IAW AMM 33-51-04-960-801.SDR CALA2016021900116Battery · weakEPL LIGHTS AT SEATS 15 - 21 & LT OVERWING FWD HAVE WEAK BATTERY PACK. R & R BATTERY AT M1694. OPERATIONS CHECKED GOOD IAW AMM 33-51-06-960-805.SDR CALA2016021900115Battery Pack · weakRIGHT AFT SERVICE DOOR, EMER LIGHTS HAVE WEAK BATTERY PACK. R & R EMER EXIT BATTERY PACK, RT AFT SERVICE DOOR M1672. PERFORMED TEST IAW AMM. 33-51-06. TESTED OK.SDR CALA2016021600111Tire · blownON TAKEOFF, ADVISED BLOWN TIRE ON TAKEOFF. OVERWEIGHT LANDING, 151.3 WEIGHT. SINK RATE 600 FPM, REF SPEED 149K. REPLACED NR 2 MLG TIRE & WHEEL ASSEMBLY IAW AMM 32-45-11. SEE LOG PAGE 8355523 FOR BURST INSPECTION WHEEL OFF B0086.SDR CALA2016021500109Warning System · false activationTAKEOFF CONFIGURATION. WARNING WENT OFF AT 100 KTS. ACFT WAS PROPERLY CONFIGURED, NO WARNING DURING TAKEOFF ROLL UNTIL 100 KTS & NO WARNING DURING THE TEST ON THE BEFORE TAKEOFF FINAL ITEMS. TROUBLESHOOTING IAW FIM TASK 31-51-00-810-801, FOUND 3 FAULTS MGS 3SDR CALA2016021200106Transmitter · malfunctionedFLAPS WOULD ONLY EXTEND TO THE FLAPS 2 POSITION IN NORMAL. HAD TO USE ALTERNATE FLAPS TO EXTEND THE FLAPS TO 30. FLAPS WHERE SYMMETRIC. TROUBLE SHOT IAW FIM 27-51-00. R & R RT FLAP TRANSMITTER IAW AMM TASK 27-58-01. OPERATIONAL TESTS PASSED.SDR CALA2016021200103Stringer · corrodedSTRINGER L25 CORRODED AT FWD SPLICE, AT STATION 371. INSTALLED STRINGER REPAIR IAW SRM 53-00-03 REPAIR 1. SEE ATTACHED FORM 44.0008 FOR ALL WORK STEPS COMPLETED.SDR CALA2016021200102Stringer · damagedDAMAGED RIVET STRINGER 27L, STATION 371. INSTALLED REPAIR IAW SRM 53-00-03 REPAIR 1. SEE ATTACHED FORM 44.0008 FOR ALL WORK STEPS COMPLETED.SDR CALA2016021200101Skin · crackedTHERE IS A CRACK IN THE LOWER LT HORIZONTAL STAB SKIN, AT STATION 138.70, APPROX. 18.5" FWD OF THE REAR SPAR, APPROX 3/8" LONG. INSTALLED REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11.SDR CALA2016020800095Frame · damagedFORWARD PIT, RT SIDE, FRAME AT STATION 500 I, BELOW Z CHANNEL, HAS DAMAGE. ACCOMPLISHED INTERIM REPAIR IAW ECRA 5310-06749 PT 1.SDR CALA2016020800094Unknown · malfunctionedAIR RETURN FOR CABIN ACT LIGHT & HORN ON IN CLIMB. ACFT WOULD NOT PRESS. PRESSURIZATION TESTED GOOD. PRESSURIZATION SYS GND BITE TEST IAW MM 21-31-00, CHECKED OK. SUSPECT PACKS WERE NOT TURNED ON.
Back to Boeing 737-824