As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB OUT, PASSING 15,000 FT NR 1 ENG OVERHEAT LIGHT ILLUMINATED IAW QRH. REDUCED THRUST LIGHT WENT OUT. DECLARED EMER & PERFORMED OVERWEIGHT LANDING AFTER REPLACEMENT OF NR 1 ENG B LOOP HARNESS & CLEAR FIRST OFFICERS MEL ITEM 2602C. PERFORMED 4 MIN. 85% N1 POWER RUN ON NR 1 ENG. BLEED PRESS 42PSI NO OVERHEAT OR FAULTS NOTED.