Boeing 737-824
Service difficulty reports · 9,839
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737824' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737824' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2011080400526Sign · brokenAFT GALLEY EXIT SIGN CAME OFF. REPLACED AFT GALLEY EXIT SIGN ASSY NEXT TO AFT ENTRY DOOR & OPS CHECKED GOOD.SDR CALA2011080100524Skin · dentedSUPPORT TASK - LEFT HORIZONTAL STABILIZER LEADING EDGE HAS MULTIPLE ABRASIONS, TOOLING MARKS, AND SMALL DENTS BETWEEN STA 271 AND 281. REMOVED AND REPLACED LEFT HORZ STAB L/E SKIN BETWEEN STA 271 AND 281 REF SRM 51-40-02.SDR CALA2011080100523Skin · dentedSUPPORT TASK FUSE EXTERIOR SKIN HAS DENT AT STA 500D + 17" BETWEEN STR 16L AND 17L. REPAIRED FUSE EXTERIOR SKIN STR 16L AND 17L DENT PER SRM 53-00-01 REPAIR 3 PG 201-208.SDR CALA2011080100522Skin · scratchedSCRATCH AT EXTERIOR SKIN BETWEEN STR 5L AND STR 6L STA 271 APPROX FUSE AREA. REPAIRED AS PER SRM 53-00-01 REPAIR 6. DIP INSPECTION REQUIREMENTS IAW SRM 53-00-01 REPAIR 6 PARAGRAPH 5 B. INITIAL INSPECTION THRESHOLD OF 50,000 FLIGHT CYCLES. FUSELAGE SKIN DAMSDR CALA2011072900519Beam · corrodedCORROSION AT STA 986 LBL 20 - LBL 44 AT N/P HOLE S. REMOVED DAMAGE PER ECRA 5321-01429, FABRICATED REPAIR ANGLES, STRAPS & FILLERS PER ECRA 5321-01429, TREATED & PRIMED REPAIR PARTS PER SRM 51-20-01 & INSTALLED PER ECRA 5321-01429.SDR CALA2011072800516Access Panel · corrodedLOWER LEADING EDGE ACCESS PANEL 621 RB SLAT STATION 337.62HAS 2 AREAS OFF CORROSION (MARKED) REF W/C 29-2700-1-2109 REPAIR PER EC/RA 5730-02680 SEE ADDTL WORK COMPLETED ON FORM 44.0008 INITIATING DIP TO PERFORM A PERMANENT REPAIR W/IN 12 MONTHS PLANNING TO CONSDR CALA2011072800518Intercostal · crackedINTERCOSTAL CRACKED FWD CABIN FLOOR STRUCTURE BETWEEN STA 344-360 AT BL 0. REMOVED AND REPLACED INTERCOSTAL BETWEEN STA 344-360 AT BL 0 REF SRM 51-40-02.SDR CALA2011072800515Skin · corrodedFX STA 727J LBL 10 DRAIN HOLE CUTOUT AREA FOUND CORROSION AFTER DRAIN PLUG REMOVED FX STA 727J LBL 10 DRAIN HOLE CUTOUT AREA CORROSION REMOVED. DEPTH 0.024" (ORIG 0.98") OUT OF SRM 53-00-01 ALLOWABLE DAMAGE 1 FIG 103 LIMIT AND CORRODED SKIN AREA REPAIRED AS PSDR CALA2011072800514Skin · corrodedFX STA 727E RBL 10 DRAIN HOLE CUTOUT AREA FOUND CORROSION. AFTER DRAIN PLUG REMOVED. FX STA 727E RBL 10 DRAIN HOLE CUTOUT AREA CORROSION REMOVED. DEPTH 0.019" (ORIG 0.116") OUT OF SRM 53-00-01 ALLOWABLE DAMAGE 1 FIG 103 LIMIT AND SKIN CORRODED AREA REPAIREDSDR CALA2011072700513Floor Support · corrodedCABIN STA 992 RBL 35-38 FLOOR SUPPORT HAT SECTION CORRODED. CABIN STA 992 RBL 35-38 FLOOR SUPPORT HAT SECTION CORROSION REMOVED DEPTH 0.012 ORIG 0.055 OUT OFF SRM 53-70-51 ALLOWABLE DAMAGE 1 FIG 103 LIMIT AND CORRODED HAT SECTION REPLACED SRM 51-10-02 AND NEWSDR CALA2011072600512Skin · crackedCRACK FOUND ON LT HORIZONTAL STAB AT 3RD RIB FROM INBD (STA 101.90) APPROX 10 INCHES FWD OF AFT SPAR. CRACK APPROX 1 INCH LONG. INSTALLED REPAIR DOUBLER ON LT HORIZONTAL STAB AT 3RD RIB FROM INBD (STA 101.90) IAW SRM 55-10-01 FIG 204 REPAIR 11. DIP INSPECTISDR CALA2011072600510Probe · faultyCLIMBING THROUGH 10000FT-11000FT WITH AUTO THROTTLES ENGAGED.NR 1 ENG EGT SURGED TO AROUND 945 DEGREE TURNING GAUGE RED. RETARDED THROTTLE AND EGT COOLED TO MANAGEABLE TEMP WITH EGTS MATCHED, N1S SPLIT 10 PERCENT. WITH N1S MATCHED, NR 1 EGT 30 DEGREES HOTTER SDR CALA2011072500509Wire Harness · brokenENG NR 2 OVERHEAT CAME ON ABOUT 400FT AGL. LIGHT CAME ON INTERMITTANTLY FOR ABOUT 8 MINS & THEN WENT STEADY. QRH CHECK LIST RUN. ENG NR 2 WAS SHUT DOWN. RETURNED TO FIELD. WINDMILL 10-12 MINS. T/S PER FIM TASK 26-10-00-810-811, PERFORMED BITE TEST OF ENSDR CALA2011071800499Skin · damagedSUPPORT TASK - THE C2 DOOR HAS 2 CREASES SIDE BY SIDE 32 INCHES FROM THE BOTTOM EDGE OF THE DOOR, AND 16 AND 19 INCHES FROM THE FWD EDGE. REPAIRED C2 DOOR REF SRM 52-00-01 REPAIR 3.SDR CALA2011071800498Light · failedFWD GALLEY LIGHT INOP BURNING SMELL NOTED AND THEN LIGHT BURNED OUT. REMOVED AND REPLACED FWD AREA GALLEY LIGHT ASSY. OPS GOOD.SDR CALA2011071800497Probe · malfunctionedL ELEV PITOT INOP R&R L ELEV PITOT PROBE PER AMM 27-31-94-400-801. NO LEAKS NOTED, OPERATION NORMAL. LEAK TEST PER AMM 27-31-17-790-801.SDR CALA2011071500495Door · openNOISE AND VIBRATION AFTER TAKEOFF AT ALL SPEEDS & ALTITUDES NEAR F/O WINDOW. FOUND EXT POWER PANEL DOOR OPEN, CHECKED DOOR AND LATCHES--IN SERVICEABLE CONDITION. ALL OTHER PANELS AND DOORS ARE CLOSED.SDR CALA2011071500494Skin · crackedSUPPORT TASK RT HORIZONTAL STAB LOWER SKIN HAS CRACKED AT SS 13 8.70. INSTALLED REPAIR REF:SRM 55-10-01 REPAIR 11.SDR CALA2011071400493Control Valve · inoperativeBLEED TRIP OFF LIGHT ILLUMINATED--WILL NOT RESET-- CAME ON AT LEVEL 33K REPLACED PRECOOLER CONT VLV PER 36-12-02. CHECKS GOOD ROTABLE PARTS CHANGE WAS INDICATED - TT 1380503 /N OFF 05309 VALVE, PRECOOLER OFF 29-3617-9-0001 5309 ON 29-3617-9-0001 4648.SDR CALA2011071400492Pressure Switch · defectiveFAIL O2 MASK DROP PER W/C 29-3520-1-7100, REPLACED PRESSURE SWITCH PER 35-22-41.SDR CALA2011071800496Valve · malfunctionedDURING FLAP EXTENSION TO FLAPS 30 TRAILING EDGE EXTEND NORMALLY LEAD EDGE DEVICE (SLATS) DID NOT EXTENDED NORMALLY LEADING EDGE FLAPS DID NOT EXTEND NORMALLY. PERFORMED T/S PER FIM 27-81-00-810-806 FOUND INTERMITTENT FAULT. OK TO CONTINUE. REMOVED AND REPLASDR CALA2011071400491Valve · malfunctionedDURING FLAP EXTENSION TO FLAPS 30 TRAILING EDGE EXTEND NORMALLY LEAD EDGE DEVICE (SLATS) DID NOT EXTENDED NORMALLY LEADING EDGE FLAPS DID NOT EXTEND NORMALLY. PERFORMED T/S PER FIM 27-81-00-810-806 FOUND INTERMITTENT FAULT. OK TO CONTINUE AND REMOVED AND REPSDR CALA2011071300489Switch · inoperativeL/E FLAPS TRANSIT LIGHT REMAINED ILLUMINATED DURING FLAPS 5 EX TEND ON TAXI. FSEU HAS MSG 27-81222, 4 L/E FLAP RETRACT SWITCH FAULT. T/S PER FIM 27-88-00-810-805. R&R'D S174, 4 L/E RETRACT SWITCH IAW AM M27-88-11, L/E FLAP/SLAT POS IND SYS OPS CHECK GD PER SDR CALA2011071300488Probe · failedLT ELEV PITOT LIGHT ILLUMINATED 8 MINUTES AFTER T/O AT 2236Z. FOUND ELEV PITOT LT CB OUT. RESET CB AT 2231Z. CB POPPED OUT AGAIN AT 2236Z. REMOVED AND REPLACED LT ELEV PITOT PROBE IAW 27-31-94, OPS & LEAK CHECK GOOD REF M/M 27-31-17-790-801, 30-31-00-730-8SDR CALA2011071300487Electronic Unit · faultedFLAPS WOULD NOT EXTEND BEYOND 25DEG WITH FLAP HANDLE AT 30DEG PERF GO AROUND AND RAN QRH LANDED WITH FLAPS 15DEG PER PROCEDURE REMOVED AND REPLACED FSEU AS PRECAUTIONARY IAW MM 27-51-01 PERF TESTS OPS CHECKS GOOD CYCLED FLAPS SEVERAL TIMES OPS AND IND CHECK GOSDR CALA2011071200484Proximity Sensor · malfunctionedAT TOP OF CLIMB AMBER L/E TRANSIT LIGHT ILL. NR 1 FLAP L/E DEVICE LT ILLUMINATED. REMOVED AND REPLACED L/E FLAP RETRACT SENSOR (S168) PER AMM 27-88-11. PERFORMED L/E FLAP/SLAT PROX SENSOR TEST PER AMM 27-88-11-700-801. ALL INDICATIONS NORMAL.SDR CALA2011071100482Unknown · malfunctionedAFTER TAKEOFF WENT TO RAISE THE GEAR AND WITH GEAR HANDLE IN UP POSITION ALL 3 RED GEAR LIGHTS STAYED ON. MOVED GEAR HANDLE TO OFF POSITON AND 3 RED GEAR LIGHTS STILL STAYED ON. CHECKED THE 5 ROWS OF CIRCUIT BREAKERS ON P6-3 ALL WERE IN AFTER 1 TO 1.5 MINUTESDR CALA2011071100480Floorbeam · corrodedSTA 986.5 FLOORBEAM HAS CORR AT FASTENER HOLE LBL 43. REPAIRED CABIN FLOORBEAM STA 986.5 LBL 43 PER ECRA 5321-01429 ATTACH FORM 44.0008,PAGE 1 TO PAGE 2- ITEM 1 TO ITEM 12.SDR CALA2011071100479Floorbeam · corrodedSTA 986.5 FLOORBEAM HAS CORR AT FASTENER HOLE RBL 43 REPAIRED CABIN FLOORBEAM STA 986.5 RBL 43 PER ECRA 5321-01429 ATTACHED FORM 44.0008 PAGE 1 TO PAGE 2, ITEM 1 TO ITEM 10.SDR CALA2011071100478Skin · crackedSUPPORT TASK FOUND CRACK ON LEFT LOWER HORIZONTAL SKIN AT STA 129.5 9 INCHES FROM THE FWD SPAR ACCOMPLISHED PER ECRA 5510-02188 SEE 44.0008 REINSPECT AS PER SRM 55-10-01 REPAIR 11 INSPECTION THRESHOLD OF 56000 CYCLES AND EVERY 9000 CYCLES THEREAFTER REFERENCE SDR CALA2011071100477Skin · crackedSUPPORT TASK FOUND CRACK ON LEFT LOWER HORIZONTAL SKIN AT STA 1 38.70 25 INCHES FROM THE FWD SPAR. ACCOMPLISHED REPAIR AS PER ECRA 5510-02188 SE 44.0008. REINSPECT AS PER SRM 55-10-01 REPAIR 11 INSPECTION THREASHOLD OF 56000 FLT CYCLES AND EVERY 9000 CYCLE TSDR CALA2011071100476Frame · crackedSUPPORT TASK FOUND ON GV INSP OF EA 5310-04716 REV C OP 2 STEP 3.0 STRUCTURAL DAMAGE CRACK BETWEEN STR 8R AND STR 9R ON FRAME 480 RT. REPAIRED CRACK AT FRAME 480 RT BETWEEN STR 8R AND STR 9R IAW EA 5310-04716 REV C OP 2.SDR CALA2011070800472Stop Fitting · out of adjustEXTREMELY LOUD RUSH OF AIR COMING FROM THE MIDDLE HINGE OF FWD ENTRY DOOR (1L) FOUND DOOR STOP OUT OF RIG. ADJUSTED DOOR STOPS PER AMM 52-11-00-820-801. PRESSURIZED AIRCRAFT PER TASK 05-51-91-750-801 NO LEAKS NOTED. OK FOR SERVICE.SDR CALA2011070800470Frame · crackedSUPPORT TASK FOUND ON GENERAL VISUAL INSPECTION OF EA 5310- 04716 REV C OPS 2 STEP 3 STRUCTURE DAMAGE (CRACK ) BETWEEN STRINGER 8R & 9R. REPAIRED FRAME AT STA 440 RT PER EA 5310 04716 REV C OPS 2 FIG 3.SDR CALA2011070700466Frame · crackedSUPPORT TASK PAX CABIN HAS CRACKED FRAME 500FL BETWEEN STR 9L AND 8L. REPAIRED CRACKED FRAME AT STA 500F LEFT SIDE. REF EA 5310-04716 REV C OPS 2.SDR CALA2011070700468Frame · crackedSUPPORT TASK FOUND ON GV INSP OF EA 5310-04716 REV C OP 2 STEP 3.0 STRUCTURE DAMAGE CRACK BETWEEN STR 8R AND STR 9R ON FRAME 380 RT SIDE REPAIRED DAMAGE AT FRAME 380 RT SIDE PER EA 5310-04716 REV C FIG 3.SDR CALA2011070700467Skin · crackedSUPPORT TASK RT HORIZ STAB LOWER SKIN SHOW CRACK INDICATION C-SCAN APPROX STA 138.70 I/B OF DRAIN HOLE COMING OUT OF FASTENER APPROX .250 OF INCH ACCOMPLISHED REPAIR PER ECRA 5510-02173 AND SRM 55-10-01 REPAIR 11. REINSPECTION REQ PRIOR TO 56000 FLT CYC'S TO SDR CALA2011070700463Frame · crackedPASSENGER CABIN, RT SIDEWALL,STA 480 & S-8R. FRAME APPEARS TO BE CRACKED AT I/B FASTENER WHERE PSU BRACKET ASSEMBLY ATTACHES TO FRAME (MARKED). REPAIRED CRACKED FRAME PER EA5310-04716 REV C OP02.SDR CALA2011070700464Frame · crackedSUPPORT TASK STA 400R HAS CRACKED FRAME BETWEEN STR8-9 AT PSU ATTACH BRACKET. REPAIRED PER EA 5310-04716 REV C.SDR CALA2011070700465Frame · crackedSUPPORT TASK - STA 380R HAS CRACKED FRAME BETWEEN STR 8-9 PSU AT TACH BRACKET. REPAIRED FRAME STA 380R, STR 8-9 PER EA 5310-04716 REV C.SDR CALA2011070700462Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED AT BL 0 STA 344-360. INSTALLED NEW INTERCOSTALL REF SRM 51-40-02.SDR CALA2011070700460Spar · corrodedLT WING L/E FRONT SPAR FOUND CORROSION AT OFFS 449 AREA L WING L/E FRONT SPAR WEB. CORROSION REMOVED AS PER SRM 51-10-02, REMOVED AREA DEPTH 0.121" (ORG. 0.185") WIDTH 1"X LENGTH 3" OUT OF SRM 57-20-10 ALLOWABLE DAMAGE 1 FIG 103 LIMIT AND FRONT SPAR WEB CORROSDR CALA2011070100457Indicator · inoperativeAFT EMERGENCY FLASHLIGHT INOP. REPLACED EMERGENCY FLASHLIGHT OPS CHECK GOOD AMM 25-64-00. (NOTE: FLIGHT ATTENDANT PREFLIGHT NOTED BATTERY INDICATOR INOP. HOWEVER FLASHLIGHT ILLUMINATES WHEN REMOVED FROM STOWED POSITION.)SDR CALA2011062900455Bulkhead · canningSUPPORT TASK TOP LT SIDE AFT 1016 PRESSURE B/H BETWEEN STR 1L AND 2L HAS OIL CAN (PRESSURE WEB DEVIATED FWD). REPAIRED PER ECRA 5311-01531 PARTIAL WORKED ACCOMPLISHED BACK F NR AND 44.0008 ATTACHED. ISSUE A DIP TO ACCOMPLISH A PERMANENT REPAIR BEFORE 46797 FSDR CALA2011062800454Skin · crackedREF EA 5510-01843 PERFORMED C-SCAN INSP OF RT STAB LOWER SKIN. FOUND CRACK INDICATION AT STA 138.70 AND 17 INCHES FROM AFT SPAR. CRACK LENGTH 1 INCH LONG. REPAIRED RT STAB LOWER SKIN IAW EC/RA 5510-02183 AND SRM 55-10-01 REPAIR 11. DIP INITIATED FOR AN INSSDR CALA2011062200449Skin · crackedPER EA 5510-01843 PERFORMED C-SCAN INSPECTION, FOUND CRACK INDICATION ON LEFT HORIZONTAL STAB LOWER SKIN STA 129.5 17 INCHES AFT OF FRONT SPAR (CRACK 1.250" LONG). REPAIRED LT HORIZONTAL STAB LOWER SKIN IN ACCORDANCE WITH EC/RA 5510-02182 AND SRM 55-10-01 REPSDR CALA2011062200448Floor Support · crackedFLOOR SUPPORT CRACKED BL 0 STA 344-360 CTN 53-390-00. REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL AT STA 344-360 BL-0 REF- DWG 141A5410 REV IR AND SRM 51-40-02.SDR CALA2011062200447Floor Support · crackedFLOOR SUPPORT CRACKED RBL 32 STA 312-328. CTN 53-390-00. REMOVED AND REPLACED FLOOR SUPPORT REF SRM 51-40-02.SDR CALA2011061600439Clamp · looseENGINE 2 OVERHEAT LIGHT CAME ON ONE MINITE AFTER TAKE OFF. WENT WITH POWER REDUCTION PER CHECK LIST. INSPECTED NR 2 ENGINE OVERHEAT SYSTEM PER THE AMM 26-10-00-710- 801. FOUND 2 EA LOOSE CLAMPS ON DUCTS. SECURED BOTH CLAMPS INSPECTED ALL WIRES TO OVERHEAT SDR CALA2011061400436Skin · crackedPER EA 5510-01843, PERFORMED C-SCAN INSPECTION ON LT HORIZONTAL STAB, FOUND CRACK INDICATION AT STA 129.5 17" AFT OF FRONT SPAR 1.0" LONG. CORRECTED TO READ AIRCRAFT 272 REPAIRED LT LOUVER HORIZONTAL STAB PER ECRA 5510-02181.
Back to Boeing 737-824