As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ENG NR 2 OVERHEAT CAME ON ABOUT 400FT AGL. LIGHT CAME ON INTERMITTANTLY FOR ABOUT 8 MINS & THEN WENT STEADY. QRH CHECK LIST RUN. ENG NR 2 WAS SHUT DOWN. RETURNED TO FIELD. WINDMILL 10-12 MINS. T/S PER FIM TASK 26-10-00-810-811, PERFORMED BITE TEST OF ENG/AP U FIRE DET MODULE. NO FAULTS FOUND. FOUND CONNECTION ON RT ENG CORE LOOP BROKEN. REPLACED BOTH LT AND RT CORE WIRE HARNESS ASSY'S MWO325 & MNO326.RAN ENG'S AT VARIOUS POWER SETTING, NO FAULTS, NO LIGHTS CHECKS GOOD.