SDR ASAA2017101422195Bulb · failedTEMP INDICATOR IN LEFT PACK POSITION INDICATES ZERO. PRESSURE NORMAL. ACFT GROUNDED. REMOVED AND REPLACED THE LEFT PACK TEMP BULB IAW AMM 21-51-60-000-801, AND 21-51-60-400-801, OPS CHECKED GOOD.SDR ASAA2017101422192A/C Pack · malfunctionedONCE GROUND AIR WAS DISCONNECTED AND ON APU BLEED AIR CABIN TEMP INCREASED AND WOULD NOT COOL. CONTROL CABIN AIR WAS COOL. FA'S AND PAX WERE EXTREMELY UNCOMFORTABLE. ACFT GROUNDED. PERFORMED A PACK TEMP CONTROL BITE PROCEDURE IAW AMM 21-62-801. NO FAULT FSDR ASAA2017101422191Warning Light · illuminatedLEFT PACK ANNUNCIATOR ACTIVATED DURING RECALL. ACFT GROUNDED. RAN THE LT PACK AND PACK LIGHT DID NOT COME ON, INTERMITTENT FAULT IAW FIM 21-53, TASK 809. PERFORMED BITE OF PACK ZONE TEMP CONTROLLER AND BITE SHOWED A FAULT FOR THE RAM AIR ACTUATOR. NO FAULTSDR ASAA2017101322362Bulkhead Web · corrodedAFT PRESSURE BULKHEAD WEB AT BS 1016, LBL 13 CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS. REMVOED & REPLACED THE BULHEAD WEB IAW SRM 51-40-02 & DWG 147A5700, REV A.SDR ASAA2017101322206Fault Message · false activationSHORTLY AFTER TAKE OFF, XB APPEARED ON NR 2 ENGINE N2. NO INDICATION OF ENGINE FAILURE OR MALFUNCTION. AFTER 11000 FT AND APPROXIMATELY 300 KTS, XB EXTINGUISHED. XB ANNUNCIATED AGAIN DURING DESCENT, SLOWING THRU 290 KTS. ACFT GROUNDED. FOUND PSEU MESSAGESDR ASAA2017101222193Control Valve · faultedLEFT PACK LIGHT ILLUMINATED IN FLIGHT AND EXTINGUISHED. ACFT GROUNDED. PERFORMED A PACK ZONE TEMERATURE CONTROL BITE TEST IAW AMM 21-61-00-700-806-002, FAULTED LEFT PACK TCV. REMOVED LEFT PACK TCV IAW AMM 21-51-10-000-801, AND INSTALLED IAW AMM 21-51-10-400SDR ASAA2017101222181Interlock · malfunctionedAFCS ENGAGE INTERLOCK A ON P18-3 AND AFCS ENGAGE INTERLOCK B ON P6-2 FOUND OUT. ACFT GROUNDED. RESET BOTH CIRCUIT BREAKERS IAW AMM 20-60-01. DFCS FAULT HISTORY SHOWS NO ASSOCIATED DISCREPANCIES. ACCOMPLISHED FIM 22-13, TASK 821 AND FIM 22-13, TASK 822. CURRSDR ASAA2017101122361Web · corrodedMAIN CABIN AT BS 989, LBL 30 WEB CORRODED. GROUNDED - YES. REMOVED CORROSION FROM WEB REF SRM 51-10-02 (LENGTH -1.9" X .84" WIDE) BEYOND ALLOWABLE LIMITS MORE THAN 50% LOSS OF MATERIAL (ORIG.020, REMOVED .012, REMAINING .008 REF BAC DWG 147A5712) REMOVED & REPSDR ASAA2017101122285Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS 380 - 400, LBL 3. ACFT GROUNDED. REMOVED THE FLOOR SUPPORT UPPER ANGLE IAW SRM 51-40-02. LOCATED, AND DRILLED IAW SRM 51-40-05, AND INSTALLED IAW SRM 51-40-02.SDR ASAA2017101122284Floor Support · crackedFLOOR SUPPORT UPPER FLANGE CRACKED, BETWEEN BS 380 - 400, RBL 7. ACFT GROUNDED. REMOVED THE FLOOR SUPPORT IAW SRM 51-40-02. LOCATED, AND DRILLED A NEW FLOOR SUPPORT IAW SRM 51-40-05, AND INSTALLED IAW SRM 51-40-02.SDR ASAA2017101122249Web · corrodedAFT CARGO DOOR CUTOUT, LOWER SILL WEB CORRODED AND HAS LARGE AREAS OF BARE METAL AND PEELING PAINT. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1. REMOVED AND REPLACED THE LOWER SILL WEB IAW SRM 51-40-02, DWG 146SDR ASAA2017101122177Lens · damagedEMERGENCY EXIT SIGN ADJACENT TO RIGHT FORWARD OVERWING EXIT HAS A DAMAGED LENS. ACFT GROUNDED. REMOVED AND REPLACED THE LENS AND TESTED THE LIGHT ASSEMBLY IAW AMM 33-51-01-960-801. OPS NORMAL.SDR ASAA2017101122176Bulb · failedEXTERIOR SLIDE EMERGENCY LIGHT ON OUTSIDE FUSELAGE, ADJACENT TO L2 DOOR IS INOPERATIVE. ACFT GROUNDED. REPLACED THE BULB AND TESTED IAW AMM 33-51-04-960-801. OPS NORMAL.SDR ASAA2017101122173Transceiver · failedNR 2 HF INOPERATIVE. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 HF TRANSCEIVER IAW AMM 23-11-21/401. THE NR 2 HF OPS CHECKED NORMAL.SDR ASAA2017101122162Floor Support · corrodedBS 340, LBL 12 FLOOR SUPPORT CORRODED. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW DWG 141A5400, AND SRM 51-40-02.SDR ASAA2017101022360Web · corrodedCORROSION ON WEB AT RBL 30, BS 1016. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS. REMOVED & REPLACED THE WEB IAW SRM 51-40-02 & DWG 147A5700, REV A.SDR ASAA2017101022338Strap · corrodedCORROSION ON STRAP AT RBL 27.95, BS 1019. ACFT GROUNDED. REMOVED THE CORROSION IAW SRM 51-10-02, AND DWG 147A5712, FOUND TO BE BEYOND ALLOWABLE LIMITS. REMOVED & REPLACED THE STRAP IAW SRM 51-40-02 & DWG 147A5700, REV A.SDR ASAA2017101022337Strap · corrodedCORROSION ON STRAP AT LBL 17.62, BS 1028. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE STRAP IAW SRM 51-40-2, & DWG 147A5700, REV A.SDR ASAA2017101022336Floorbeam · corrodedCORRODED FLOORBEAM BS 986, LBL44. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51, AND FOUND TO BE BEYOND ALLOWABLE LIMITS. REPAIRED THE FLOORBEAM IAW SRM 53-70-51, REPAIR 4.SDR ASAA2017101022263Skin · crackedONE CRACK INDICATION, INBOARD OF HSS 101.90, RT LOWER SKIN, 12 INCHES FORWARD OF REAR SPAR. ACFT GROUNDED. REMOVED DAMAGE ON THE SKIN AND INSTALLED A DOUBLER IAW SRM 55-10-01-2R-11.SDR ASAA2017101022186Bulkhead Web · crackedLEFT MLG WW BS 663, LBL 48 BULKHEAD WEB FOUND CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE BULKHEAD WEB IAW SRM 51-40-02, DWG 111A1000 REV F, AND DWG 111A1112 REV-.SDR ASAA2017101022174Idg · failedNR 1 GENERATOR AT FL 360, DRIVE LIGHT DID NOT ILLUMINATE. TRIED TO RESET THE GENERATOR IAW QRH BUT DID NOT COME BACK ONLINE. APU STARTED AND POWERED LEFT TRANSFER BUSS FOR REMAINDER OF FLIGHT. ACFT GROUNDED. REMOVED AND REPLACED THE NR 1 IDG IAW AMM 24-11-11.SDR ASAA2017101022178Filter · damagedNR 2 ENGINE SCAVENGE FILTER ASSEMBLY BOWL HAS DAMAGED THREADS. ACFT GROUNDED. REMOVED AND INSTALLED A NEW SCAVENGE OIL FILTER ASSEMBLY IAW AMM 79-21-04--000-801-F00, AND 79-21-04-400-801-F00. LEAK CHECKED GOOD.SDR ASAA2017101022161Warning Light · false activationPACK LIGHT ILLUMINATED DURING DESCENT CHECKLIST RECALL. RAN CHECKLIST 2.12, PACK LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP BITE BOTH CONTROLLERS IAW AMM 21-61-00, SHOWED FAULT ON THE NR 1 CONTROLLER RAM AIR ACTUATOR. RESET AND PERFORMEDSDR ASAA2017101022157Warning Light · false activationWINDOW OVERHEAT ILLUMINATED, ACCOMPLISHED QRH AND LIGHT EXTINGUISHED. ACFT GROUNDED. ALL WINDOW HEAT TESTED AND OPS CHECKED GOOD IAW AMM 30-41-41.SDR ASAA2017101022156Indicator · failedCENTER TANK REFUELING CONTROL PANEL QUANTITY INDICATOR BLANK. ACFT GROUNDED. CHECKED VOLTAGE AT PIN 24, NO DEFECTS NOTED. REMOVED AND REPLACED CENTER REFUELING QUANTITY INDICATOR. OPS CHECKED GOOD IAW IAW AMM 28-41-61.SDR ASAA2017101022154Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED AFTER TAKEOFF. EXTINGUISHED AFTER MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED FIM 21-62 TASK 801. RT PACK TEMP CONTROL BITE CHECK FAULTED TCV VALVE. PERFORMED FIM 21-62, TASK 831, & FAULT CLEARED. GROUND FUNCTIONAL CHECKED PASSSDR ASAA2017101392183Probe · dirtyFAULT CODE 77-20862 THE BOTTOM LEFT EGT SIGNAL (T495S3) IS OUT OF RANGE ECONOMIC DEFERRED PER T/C 78273000. GROUNDED - YES. DEFERRED CODE PLT, ECONOMIC FAULT 500 FLT HRS, DEFERRED PER T/C 78273000. FOUND T49.5 S3 SIGNAL TEMP HAD ALL DASHES WHEN LOOKING AT CONSDR ASAA2017100922171Warning Light · false activationFWD CABIN ZONE TEMP LIGHT ON MASTER CAUTION RECALL. GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. THE NR 2 PACK ZONE TEMP CONTROLLER SHOWS ZONE SELECTOR. ACCOMPLISHED FIM 21-62, TASK 806. FAULT CLEARED.SDR ASAA2017100922148Oil Cooler · contaminatedAFTER ENGINE START, THE NR 1 GENERATOR WOULD NOT COME ONLINE WITH DRIVE LIGHT ILLUMINATED. ACFT GROUNDED. REMOVED AND REPLACED THE NR 1 IDG IAW AMM 24-11-11. FOUND CONTAMINATION IN FILTERS. REMOVED AND REPLACED IDG AIR/OIL COOLER IAW AMM 24-11-21. REMOVED ANSDR ASAA2017100822150Display · failedISFD FAILURE DURING CLIMB OUT. SHOWED A TURNING DECENT. ACFT GROUNDED. REMOVED AND REPLACED ISFD IAW AMM 34-24-02-400-801. OPS TESTED NORMAL.SDR ASAA2017100822149Warning Light · false activationON VECTORS FOR APPROACH, NR 1 SOURCE OFF LIGHT ILLUMINATED. FOLLOWED QRH AND PUT APU ONLINE. ACFT GROUNDED. PERFORMED THE INSTRUMENT LANDING OPERATIONAL TEST IAW AMM 34-31-00-710-801 AND THE AIR DATA REFERENCE SYSTEM SELECT OPERATIONAL TEST IAW AMM 34-21-0SDR ASAA2017100822147Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. CONTROL CABIN ZONE TEMP LIGHT EXTINGUISHED WHEN MASTER CAUTION SYSTEM RESET. ACFT GROUNDED. PERFORMED THE PACK ZONE TEMPERATURE CONTROL BITE TEST IAW AMM 21-61-00-806-002. NO FAULTS FOUNSDR ASAA2017100822144Lens · missingAFT EMERGENCY SIGN LENS MISSING FROM BULKHEAD. ACFT GROUNDED. INSTALLED A NEW LENS AMM 33-51-14.SDR ASAA2017100822131Pitot Tube · shortedAFTER ENGINES STARTED THE LT ELEVATOR PITOT LIGHT ILLUMINATED. ACFT GROUNDED. IAW WDM 30-31-11 FOUND THE LT ELEVATOR PITOT HEATER OPEN D644 PIN 40 TO GND OPEN. REPLACED LT ELEVATOR PITOT TUBE IAW AMM 27-31-94-000-801 & -400-801. OPS NORMAL. LEAK CHECKED GOODSDR ASAA2017100722159Sensor · dirtyGE DIAGNOSTICS REPORTED THE NR 2 ENGINE TREND DATA SHOWS A SUDDEN DELTA EGT INCREASE AND EGT HDM DECREASE. EGT INDICATION ERRORS ARE SUSPECT. ACFT GROUNDED. ACCOMPLISHED EGT CLEANING IAW AMM 77-21-00-140-801. BEFORE TEMPS: S1/44.39, S2/19.19, S3/18.56, S4/43SDR ASAA2017100722141Connector · looseDURING TROUBLESHOOTING, FOUND THE NR 2 ENGINE CONNECTOR DP0803 TO BE LOOSE. ACFT GROUNDED. REMOVED, INSPECTED, CLEANED, INSTALLED, AND TESTED THE CONNECTOR DP0803. ALL TESTS PASSED.SDR ASAA2017100722140Wire Harness · damagedNR 1 ENGINE FILTER BYPASS LIGHT ILLUMINATED. ACFT GROUNDED. IAW WDM 73-31-11 WHILE SHAKING DOWN HARNESS NEAR DP0803 NR 1 ENG FUEL FILTER BYPASS LIGHT ON P5-2 FLICKERS ON & OFF. ACCOMPLISHED EEC TEST FOR THE NR 1 ENGINE, FOUND 73-31071. REMOVED, REPLACED ANDSDR ASAA2017100722135Unknown · unknownDURING TAXI IN, THE CAPTAIN`S SIDE FMC FAILED WITH VTK ON DISPLAY. RAN THE QRH, PG 11.3 AND CONFIRMED THAT THE LEFT FMC FAILED. ACFT GROUNDED. OPS CHECKED THE CAPTAIN`S FMC SYSTEM, CHECKED GOOD IAW AMM 34-61-00.SDR ASAA2017100722133Sign · detachedFA REPORTED AN EXIT SIGN IS HANGING BY THE WIRE MID CABIN. ACFT GROUNDED. ENGAGED THE RETAINER. LIGHT OPS NORMAL.SDR ASAA2017100622143Heat Exchanger · leakingTHE NR 1 ENGINE FUEL - OIL HEAT EXCHANGER HAS A RUNNING LEAK FROM MOUNTING BASE GASKET. ACFT GROUNDED. REMOVED AND REPLACED THE NR 1 ENGINE FUEL - OIL HEAT EXCHANGER IAW AMM 79-21-02-000-801-F00, AND 79-21-02-400-801-F00. ACCOMPLISHED TESTS LISTED IN THE POSDR ASAA2017100622139Pin · migratedFOUND THE THIRD STAGE ANTI-ROTATION PIN LOCATED AT 3 OCLOCK ROTATED 90 DEGREES & MIGRATING ON THE NR 1 ENGINE. ACFT GROUNDED. REMOVED & REPLACED THE ENGINE.SDR ASAA2017100622137Screw · brokenNR 1 ENGINE HAD A BROKEN LOCK SCREW ON THE HIGH STAGE VALVE. ACFT GROUNDED. REMOVED AND INSTALLED A NEW HIGH STAGE VALVE IAW AMM 36-11-06-400-801, AND 36-11-06-000-801. LEAK & OPS CHECKED.SDR ASAA2017100622130Circuit Breaker · openPROBE HEAT AUTO CIRCUIT BREAKER FOUND IN OPEN POSITION. ACFT GROUNDED. INSPECTED BEHIND P18-3, CAPTAIN`S PITOT TUBE AND P5-9 MODULE. NO DEFECTS NOTED. RESET THE CIRCUIT BREAKER IAW AMM 20-60-01. NO PREVIOUS HISTORY. OPS CHECKED NORMAL IAW AMM 30-31-00-730-801SDR ASAA2017100622127Actuator · malfunctionedON INITIAL DESCENT, LEFT PACK LIGHT ILLUMINATED. IAW QRH PUSHED MASTER CAUTION RESET AND PACK LIGHT EXTINGUISHED. ACFT GROUNDED. LEFT PACK/TEMP CONTROLLER LOGGED THE RAM AIR ACTUATOR ON LAST FLIGHT. FAULT RESET, BITE CHECK OF THE LT TEMP CONTROLLLER WAS NSDR ASAA2017100522129Pump · failedCENTER, RIGHT FUEL PUMP SHOWING LOW PRESSURE, CTR TANK SHOWS 2340 LBS. ACFT GROUNDED. REMOVED AND REPLACED THE FUEL PUMP IAW AMM 28-22-41. OPS CHECKED FAILED. HAS A HUMMING SOUND. NO VISIBLE DEFECTS NOTED ON CONNECTOR OR WIRING. PRIMMED THE BOOST PUMP IAW SDR ASAA2017100422110Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING PUSH BACK. COMPLIED WITH QRH PROCEDURE, LIGHT RESET WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED A BITE TEST IAW AMM 21-51-00-700-803 - NO FAULTS FOUND. PERFORMED CABIN TEMP CONTROL OPS CHECK IAW AMM 21SDR ASAA2017100422112Controller · failedLEFT FWD WINDOW OVERHEAT. COMPLIED WITH QRH. LIGHT REMAINED ILLUMINATED. ACFT GROUNDED. FOUND THE CIRCUIT BREAKER C228 TRIPPED. OPENED THE CIRCUIT BREAKER PANEL AND FOUND TERMINALS DISCOLORED. REPLACED THE TERMINALS AND CIRCUIT BREAKER IAW SWPM 20-30-11. SDR ASAA2017100422109Outflow Valve · obstructedAFTER ENGINE START AND PACKS RUNNING, AUTO FAIL LIGHT ILLUMINATED. THE LIGHT EXTINGUISHED WHEN ALTERNATE MODE SELECTED. ACFT GROUNDED. PERFORMED A NR 1 AND 2 PRESSURE CONTROLLER BITE IAW FIM 21-31-00. FOUND AUTO FAIL ON. PLACED SWITCH TO MANUAL. FAULT LISDR ASAA2017100322117Fault Code · false activationNR 2 ENGINE BITE SHOWS A LONG TIME FAULT 73-31072, THE FUEL FILTER SIGNALS DISAGREE. ACFT GROUNDED. PERFORMED T/C 78273000, VERIFIED NO FAULT MESSAGES LOGGED FOR THE LAST 10 FLT LEGS FOR THE NR 2 ENGINE, EEC BITE TESTED WITH NO FAULTS.
Back to Boeing 737-890