What was found
AFCS ENGAGE INTERLOCK A ON P18-3 AND AFCS ENGAGE INTERLOCK B ON P6-2 FOUND OUT. ACFT GROUNDED. RESET BOTH CIRCUIT BREAKERS IAW AMM 20-60-01. DFCS FAULT HISTORY SHOWS NO ASSOCIATED DISCREPANCIES. ACCOMPLISHED FIM 22-13, TASK 821 AND FIM 22-13, TASK 822. CURRENT STATUS TEST PASSED. INITIAL EVALUATION SHOWS NO FAULTS. ACCOMPLISHED DFCS, AT LRU REPLACEMENT TEST AND LAND VERIFY BITE 49. ALL TEST PASSED. NO HISTORY LAST 30 DAYS.