Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2016031815992Knob · detachedPRESSURIZATION MODE SELECTOR KNOB FELL OUT. ACFT GROUNDED. TIGHTEN PRESSURIZATION MODE SELECTOR KNOB.SDR ASAA2016031716010Indicator · failedAIRCRAFT FUELER REPORTS NR 2 TANK GAUGE FAIL RT WING TANK. ACFT GROUNDED. R & R NR 2 TANK REFUELING QTY INDICATOR REF AMM 28-41-61. BONDING AND OPS CHECKS OK.SDR ASAA2016031716004Starter · failedAIR STARTING NR 2 ENGINE, HAD START VALVE LIGHT ON BUT NO ROTATION. APU AIR PRESSURE WAS STABLE AT 40 PSI. NR 1 ENGINE STARTED OK FROM APU BLEED AIR. TRIED 3 TIMES TO START NR 2 ENGINE WITH SAME RESULT, START VALVE LIGHT ON, NO ROTATION OF N2. ACFT GROUNDESDR ASAA2016031716003Start Valve · failedSTART VALVE OPEN LIGHT ILLUMINATING NR 2 SIDE ON GROUND ENGINES NOT RUNNING. ACFT GROUNDED. VERIFIED NR 2 START VALVE CLOSED. MANUALLY CYCLED VALVE OPEN TO CLOSE. LIGHT EXTINGUISHED. PERFORMED START VALVE LEAK CHECK REF AMM 71-00-00-700-809-F00, CHECKS NORMSDR ASAA2016031715995Autopilot Sys · malfunctionedON RECALL FLT CONTINUED AND SPEED TRIM FAIL LIGHT ILLUMINATE. AUTOPILOTS A AND B WILL NOT ENGAGE. ACFT GROUNDED. MOVED A/P STABILIZER TRIM CUTOUT SWITCH TO NORMAL. PERFORMED DFCS BITE REF FIM TASK 22-11, TASK 801. TEST PASSED. NO FURTHER FAULTS FOUND.SDR ASAA2016031615963Valve · failedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES DURING RECALL. LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. R & R CONTROL CABIN TRIM MOD VALVE V143 IAW AMM 21-61-21/401. NR 1 AND NR 2 ZONE TEMP CONTROLLER BITE TESTED GOOD. VALVE LEAKS CHECKED GOODSDR ASAA2016031615967Switch · failedLEFT THROTTLE LEVER, TAKEOFF WARNING SYSTEM INTERMITTENT. ACFT GROUNDED. R & R LEFT AUTOTHROTTLE SWITCHPACK ASSY, REF AMM 76-11-020-802-F00 AND AMM 76-11-07-400-802-F00. ACCOMPLISHED AUTOTHROTTLE SWITCHPACK ASSY TEST, REF AMM 76-11-07-400-802-F00 PARA, H, ALSDR ASAA2016031615964Static Inverter · inoperativeAFTER ENGINES STARTED, RECEIVED AN ELECTRIC LIGHT. ACFT GROUNDED. ACCOMPLISHED FIM 24-31, TASK 801. FOUND 1 FAULT STATIC INVERTER INOPERATIVE. CLEARED FAULT DID NOT REAPPEAR. ALL INDICATIONS NORMAL.SDR ASAA2016031615962Sensor · faultedAFTER ENGINE START, RECEIVED A CONTROL CABIN "ZONE TEMP" LIGHT. ACFT GROUNDED. FOUND NR 2 TEMP CONTROLLER HAD A FLIGHT CONTROL TEMP SENSOR FAULT. CLEARED FAULT TEST GOOD IAW AMM 21-61-20-860-005.SDR ASAA2016031615961Control Panel · malfunctionedCABIN ALTITUDE CONTROL PANEL DOES NOT DIM AND OUTFLOW VALVE POSITION NEEDLE IS BLANK. PRESSURIZATION NORMAL. ACFT GROUNDED. UNABLE TO DUPLICATE, VERIFY ON ACFT POWER UP. PERFORMED FIM 21-31, TASK 803. FLIGHT ALT AND LAND ALT DISPLAYS DIM AND BRIGHTEN WITH SDR ASAA2016031615960Warning Light · false activationON PREFLIGHT FOUND AUTO FAIL LIGHT ON PRESSURIZATION PANEL. ACFT GROUNDED. CHECKED MODE SELECTOR SWITCH ON CABIN PRESSURE CONTROL PANEL, FAULT CLEARED, REF FIM 21-31, TASK 801. VERIFIED BOTH CONTROLS HAD NO FAULTS.SDR ASAA2016031515943Fmc · malfunctionedFMC WOULD NOT SELECT TO POWER OR ALLOW MANUAL SELECTION OF TO POWER. ACFT GROUNDED. RESET FMCS COMPUTER 1 AND 2 CB'S, REF FIM TASK 34-61, TASK 836 AND ACARS CMU-1 AND CMU/ACARS DC C/B'S REF FIM TASK 23-27, TASK 815. NO HELP. FOUND TAT TEMP NOT DISPLAYING ANSDR ASAA2016031415911Blower · failedF/A REPORTS ALL LAVS NOT FLUSHING. ACFT GROUNDED. REPLACED LAVATORY WASTE BLOWER IAW AMM 38-32-05. ALL SYSTEMS OPS NORMAL.SDR ASAA2016031415907Magnetic Plug · failedRIGHT ENGINE STARTER MAGNETIC PLUG CHECK VALVE INOPERATIVE. ACFT GROUNDED. R & R RIGHT ENGINE STARTER MAGNETIC PLUG ASSY IAW AMM 80-11-01.SDR ASAA2016031415905Power Supply · failedREF TC 78233001, BATTERY PACKS AT LT, RT ROW 15, LT & RT ROW 22, AND RT AFT GALLEY FAILED CAPACITY CHECK. ACFT GROUNDED. R & R BATTERY PACKS AT LT, RT ROW 15, LT, RT ROW 22, AND RT AFT GALLEY. R & R POWER SUPPLY AT LT ROW 22. AMM 33-51-06, OPS CHECKS GOOD.SDR ASAA2016031415904Control Panel · failedMODE CONTROL PANEL AMBIENT LIGHT SENSOR WILL NOT DIM MCP DISPLAY. ACFT GROUNDED. REPLACED MODE CONTROL PANEL. ALL OPS NORMAL AMM 22-11-34. ACCOMPLISHED DFCS LRU INTERFACE TEST FOR MCP, BITE GROUP NR 32, LAND VERIFY TEST, BITE GROUP 49, AND HGS SENSOR TEST SDR ASAA2016031315912Arm · out of adjustUPON TAKEOFF AND CLIMB OUT CABIN ALTITUDE WAS CLIMBING AT 2000 FPM. F/A CALLED TO REPORT AN EXTREME WIND NOISE FROM THE L1 DOOR. DOOR ACFT WAS NOT PRESSURIZING. ACFT GROUNDED. UPON ACFT ARRIVAL, FOUND L1 DOOR AFT UPPER AND LOWER ROLLERS NOT ENGAGED IN TRACK SDR ASAA2016031315894Compensator · failedFUELER REPORTED LT UNDER WING FUEL GAUGE FLASHING. ACFT GROUNDED. VERIFIED TANK 1 AND TANK 2 COMPENSATOR BAD FAULTS. R & R NR 1 TANK COMPENSATOR IAW AMM 28-41-21-400-801. REPLACED NR 2 TANK COMPENSATOR UNIT IAW AMM 28-41-21-400-801. FQIS SYS TEST NORMAL, RSDR ASAA2016031315891Starter Gen · failedAPU START-GEN UNIT FAILED OPS TEST. WOULD NOT COME ONLINE, FEEDER FAULT. ACFT GROUNDED. R & R APU STARTER-GENERATOR UNIT IAW AMM 49-41-21. LEAK AND OPS TEST GOOD.SDR ASAA2016031315890Fmc · failedMOMENTARY DUAL FMC FAILURE AND "VTK" FLAG ON BOTH CAPT AND F/O'S SIDES AT ABOUT 6000' DECENDING INTO DESTINATION, CAME BACK ON BOTH SIDES WITHIN 1 MINUTE. ACFT GROUNDED. GROUND FUNCTIONAL CHECK GOOD IAW AMM 34-61-00-710-801 AND 34-61-00-730-801.SDR ASAA2016031315889Satcom · malfunctionedNO SATCOM PROMPT ON MCDU. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURE IAW QRH. SATCOM OPS NORMAL.SDR ASAA2016031215860Warning Light · false activationFWD CABIN ZONE TEMP LIGHT CAME ON DURING PUSHBACK. MASTER CAUTION RECALL RAN QRH, LIGHT WENT OUT. ACFT GROUNDED.SDR ASAA2016031215873Radar · malfunctionedWEATHER RADAR NOISE 70-90 DEGREES LT AND RT OF NOSE 5-10 MILE RANGE ENTIRE LEG. RADAR OPERATES NORMALLY OTHERWISE. ACFT GROUNDED. INBOUND CREW SAID IT WAS WORKING OK. ACFT WAS TOWED TO PERIMETER PARKING WITH NO METAL OBJECTS/BUILDINGS IN FRONT. FACING SFO FSDR ASAA2016031215871Indicator · failedFUELER ADVISES UNABLE TO FUEL ACFT. TANK 2 GAUGE AT SINGLE POINT PANEL A BLANK, TANK 2 INDICATION IN FLIGHT DECK NORMAL. ACFT GROUNDED. R & R 2 REFUEL QUANTITY INDICATORS IAW AMM 28-41-61, OPS CHECK GOOD.SDR ASAA2016031215868Satcom · lockedSATCOM LOCKUP OCCURRED. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURE IAW QRH. SATCOM OPS NORMAL.SDR ASAA2016031215866Satcom · lockedSATCOM LOCKUP ON POWER TRANSFER. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURE IAW QRH. SATCOM OPS NORMAL.SDR ASAA2016031215865Autothrottle Sys · malfunctionedAUTO THROTTLE WOULD NOT STAY ENGAGED. ACFT GROUNDED. NR 1 THROTTLE LEVER DOES NOT RESPOND TO SERVO MOTOR TEST. MULTIPLE ASM 1 FAULTS. CYCLED AUTOTHROTTLE DC1 C/B. SYS RESTORED. SERVO MOTOR TEST PASS, A/T OPS CHECK IAW AMM 22-31-00 PASS AND DFCS BITE GRP SDR ASAA2016031115886Actuator · leakingNR 2 ENGINE HAS FUEL LEAKING FROM LEFT VSV. ACFT GROUNDED. R & R NR 2 ENG LT VSV ACTUATOR IAW AMM 75-31-01. ACCOMPLISHED VSV ACTUATOR LEAK TEST IAW AMM 75-31-01-790-801-F00 TO STEP 7E2D. NOTE HMU ACT HEAD AND ROD LEAK TEST REQUIREMENT ACCOMPLISHED. VSV ACSDR ASAA2016031115880Battery Pack · failedEMERGENCY LIGHTS L1063, L730, L1417 FAILED TO ILLUMINATE DURING TEST. ACFT GROUNDED. R & R BATTERY & CHARGER. OPS GOOD REF AMM 33-51-00.SDR ASAA2016031115869Fire Detector · no testDURING ENGINE FIRE TEST THE NR 2 ENGINE FIRE HANDLE WOULD NOT ILLUMINATE. A SYSTEM FAULT LIGHT ON NR 2 ENGINE OVERHEAT DETECTION. ACFT GROUNDED. ENGINE & APU FIRE/OVERHEAT DETECTION MODULE INDICATED NR 2 ENGINE "A" LOOP UPPER FAN DETECTOR FAULT. INSPECTED UPSDR ASAA2016031115867Satcom · lockedSATCOM LOCK-UP. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURE IAW QRH. SATCOM OPS NORMAL.SDR ASAA2016031015878Power Supply · failedEMERGENCY LIGHTS FAIL DEEP CYCLE AFT OF OVERWING EXITS BOTH SIDES & L2 DOOR. ACFT GROUNDED. R & R BATTERY PACKS, OPS CHECK GOOD.SDR ASAA2016031015876Wire Harness · failedWHILE ACCOMPLISHING T/C 78273000, FOUND NR 1 ENGINE WITH SHORT TIME FAULT 78-11541, EACH REVERSER SLEEVE HAS ONE POSITION SIGNAL OUT OF RANGE. ACFT GROUNDED. REPLACED MW0303 HARNESS, ALL OPS NORMAL, REF AMM 71-51-03, 71-00-00. GROUND VERIFICATION SATISFACTORSDR ASAA2016031015875Valve · failedLT DUCT PRESSURE 15 PSI, RT DUCT PRESSURE 21 PSI AT FL 340 LT DUCT PRESSURE 19 PSI, RT DUCT PRESSURE 21 PSI. CABIN PRESSURE 7,000 FT PSID 7.9 AND STEADY. AFTER 1+30 AT FL 370 LT DUCT PRESSURE 29 PSI, RT PACK PRESSURE 38 PSI. TOP DESCENT LT PACK 15 PSI, RT PSDR ASAA2016031015863Control Panel · malfunctionedMCP BLANK ON PREFLIGHT. ACFT GROUNDED. RESET 9 C/B. MCP R2 REF AMM 22-11-34. ACCOMPLISHED MCP INSTALL TEST IAW AMM 22-11-34-740-001. SYS OPS NORMAL. ALL TESTS PASSED. PROBLEM OCCURRED AT POWER TRANSFER. BOTH APU AND GROUND POWER OK.SDR ASAA2016030915849Connector · dirtyELECTRONIC ENGINE CONTROL RECORDED FAULT 77-10842. ACFT GROUNDED. BEFORE CLEANING, S1-41.07, S2-18.80, S3-18.63, S4-39.04. AFTER CLEANING, S1-34.82, S2-18.23, S3, 17.87, S4-33.23. CLEANED EGT HARNESS IAW AMM 77-21-00-140-801. OPS NORMAL IAW FIM TASK 77-21-8SDR ASAA2016030915847Warning Light · false activationAPU BLUE MAINTENANCE LIGHT ILLUMINATED ON APU START AFTER LANDING. ACFT GROUNDED. ACCOMPLISHED APU BITE, OIL LEVEL FULL, NO FAULTS NOTED, NO FAULTS IN HISTORY. OPERATED APU, GENERATORS, AND AIR CONDITIONING. APU OPS NORMAL. BLUE MAINTENANCE LIGHT IS A NUISANSDR ASAA2016030915846Switch · failedRIGHT BLEED TRIP OFF LIGHT ILLUMINATED ON DECENT. ACCOMPLISHED QRH PROCEDURE. NORMAL OPS RESTORED. ACFT GROUNDED. R & R NR 2 ENGINE THERMO SWITCH, 490 IAW AMM 36-11-08.SDR ASAA2016030915843Radio · malfunctionedDURING ACFT TOW, ALL ATC RADIO READ BACKS UNREADABLE. ACFT GROUNDED. PERFORMED RADIO CHECK. OPS CHECK OF RADIOS IAW AMM 23-12-00. UNABLE TO DUPLICATE DEFECT. ALL GROUND TESTS PASS.SDR ASAA2016030915842Heat Exchanger · crackedLEFT PRIMARY HEAT EXCHANGER CRACKED ON LOWER SURFACE. ACFT GROUNDED. R & R THE LT PRIMARY HEAT EXCHANGER REF AMM 21-51-03-400-804-002. LEAK AND OPS CHECK GOOD.SDR ASAA2016030915841Warning Light · illuminatedAUTO FAIL LIGHT ON PRESSURIZATION SYS WITH MASTER CAUTION. SWITCHED TO ALTN, NORMAL OPERATION IN ALTN MODE. ACFT GROUNDED. NR 2 DCPC LOGGED OF VLRU FAIL FAULT NR 011. ACCOMPLISHED SYS TEST AND GROUND TEST REF FIM 21-31, TASK 801. MESSAGE NO LONGER ACTIVE OSDR ASAA2016030815848Heater · leakingENGINE NR 2 FUEL LEAK NOTED ON WALK AROUND. ACFT GROUNDED. PERFORMED ENGINE RUN ON NR 2 ENGINE. DURING ENGINE RUN NOTED A LEAK OF 8 DROPS PER MINUTE COMING FROM THE MAIN HEAT EXCHANGER OIL FUEL DRAIN LINE, DRIP IS WITHIN LIMITS IAW AMM 71-71-00-200-801 PARASDR ASAA2016030815838Manifold · wornNR 1 ENGINE TURBINE COOLING DUCT-Y HAS AREA OF HEAVY WEAR, CHAFING FROM CONTACT WITH C-DUCT HEAT SHIELD. ACFT GROUNDED. REPLACED NR 1 ENGINE TURBINE COOLING Y-DUCT, REF CFM56-7, ESM 720000430-006C60.SDR ASAA2016030815836Switch · failedNR 2 FUEL FILTER BYPASS LIGHT ILLUMINATED FOR 1 MINUTE AFTER ENGINE START. ACFT GROUNDED. ACCOMPLISHED ELECTRONIC ENGINE CONTROL TEST REF AMM 73-21-00-700-804- F00, OPS TEST GOOD. R & R THE NR 2 ENGINE FUEL FILTER DIFFERENTIAL PRESSURE SWITCH REF AMM 73-34-SDR ASAA2016030815835Lens · detachedEMERGENCY EXIT SIGN FELL OFF. ACFT GROUNDED. RE-ATTACHED EXIT SIGN, OK FOR SERVICE.SDR ASAA2016030815834Bleed Valve · failedDURING ACCOMPLISHMENT OF TC NG-36WC-00001 ENGINE NR 2 BLEED AIR SYS HEALTH CHECK, FOUND HIGH STAGE REGULATOR OUT OF LIMITS. ACFT GROUNDED. R & R NR 2 ENGINE HIGH STAGE REGULATOR REF AMM 36-11-07. OPS AND LEAK CHECK GOOD.SDR ASAA2016030815831Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. ACCOMPLISED CTC BITE WITH NO FAULTS NOTED, OR EXISTING FAULTS IN HISTORY. ZONE TEMP LIGHT DOES NOT COME ON ON RECALL. RE FIM 21-61, TASK 801.SDR ASAA2016030815829Warning Light · false activationZONE TEMP CONTROL CABIN ILLUMINATES ON RECALL. ACFT GROUNDED. NR 2 TEMP CONTROLLER SHOWS TRIM VALVE FLIGHT DECK ON BITE & PREVIOUS FLIGHT. VERIFY PASSES. RESET FAULT. FAULT DID NOT RETURN. BITE TEST SAME GOOD. REF FIM 21-62, TASK 832. FUNCTIONAL CHECK CONSDR ASAA2016030715801Lens · brokenEMERGENCY LIGHT AT L-1 DOOR LENS, FELL OFF & BROKE. ACFT GROUNDED. INSTALLED NEW L-1 DOOR EMERGENCY LIGHT LENS.SDR ASAA2016030715799Guide Vane · icedAPU START PRESSURE LOW. ACFT GROUNDED. TURNED APU OFF ALLOWED TO SIT FOR 8 MINUTES. STARTED APU, APU TESTS GOOD IAW AMM 49-11-00. SUSPECT APU INLET GUIDE VANE ICING DUE TO BRW WEATHER CONDITIONS. OK FOR SERVICE.
Back to Boeing 737-890