What was found
START VALVE OPEN LIGHT ILLUMINATING NR 2 SIDE ON GROUND ENGINES NOT RUNNING. ACFT GROUNDED. VERIFIED NR 2 START VALVE CLOSED. MANUALLY CYCLED VALVE OPEN TO CLOSE. LIGHT EXTINGUISHED. PERFORMED START VALVE LEAK CHECK REF AMM 71-00-00-700-809-F00, CHECKS NORMAL. TSR ACCOMPLISHED, R & R NR 2 ENGINE START VALVE WITH A SERVICEABLE UNIT IN REF TO AMM 80-11-03. NR 2 ENGINE START VALVE OPS CHECKS AND LEAK CHECK GOOD AT THIS TIME.