Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2013022293972Start Valve · failedHUNG START NR 2 ENGINE, AFTER ABORTING START NR 2 ENGINE START VALVE REMAINED OPEN FOR 4.5 MINUTES. CHECKED NR 2 ENG CDU NO DEFECTS NOTED. FOUND START VALVE INOPERATIVE. REPLACED NR 2 ENG START VALVE. REFER TASK 80-11-03. MEASURED BONDING JUMPER RESISTANCESDR ASAA2013022293969Bleed Valve · leakingRIGHT BLEED TRIP OFF LIGHT ILLUMINATED AT TOP OF DESCENT. RESET IAW QRH- LIGHT WENT OUT. PERFORMED FIM TASK 36-10-/801, FAILED STEP F-7 HIGH STAGE BLEED VALVE LEAK. REPLACED HIGH STAGE VALVE REF AMM 36-11-06 LEAK CHECKED AND OPS CKD OK . AS PRECAUTION ALSOSDR ASAA2013022293964Shroud · crackedAPU SHROUD HAS A CRACK ON AFT BASE 2.1 LONG. ACFT GROUNDED. R & R APU DRAIN SHROUD.SDR ASAA2013022193968Shutoff Valve · failedON CLIMBOUT THROUGH TOP OF CLIMB AT 35,000 DUCT SPLIT RT=21 L=41 GRADUALLY EVENED OUT BOTH AT 41 PSI DURING CRUISE. ACCOMPLISHED NR 2 ENG BLEED AIR SYS HEALTH CHECK REF MM 36-11-00. FOUND PRSOV LEAKING. REPLACED PRSOV. ACCOMPLISHED PRECOOLER VALVE SYS HEASDR ASAA2013022193965Unknown · unknownON BOARDING, NOTED FUEL 39.8. AT DEPARTURE, 5 MIN, STARTED APU. RUNNING PRIOR TO PUSH CHECKLIST NOTED FUEL 39.3. THIS IS AN ABNORMAL BURN FOR APU. PERFORMED COMPARISON CHECK IAW MM 28-41-00-720-801, ALL TANKS, FUEL QTY CHECKED GOOD. NR 1 TANK 8.55, STICK SDR ASAA2013022093960Sensor · brokenSTART NR 1 FAULT FL380. CSS START NR 2 RESULT FAULT FL 350. UNABLE TO CONDUCT START NR 3, DUE 5 MIN FAULT TIMER AND BELOW FL 290. FOUND BROKEN SHIELD TERMINAL AT BACKSHELL OF OIL TEMP SENSOR CONNECTOR P-15. REPLACED SHIELD TERMINAL ON OIL TEMP SENSOR CONNECSDR ASAA2013022093948Fuel Cell · contaminatedWHILE BURNING CENTER TANK FUEL, THE LT FUEL QUANTITY DROPPED TO 8.6K FOR APPROX 20 MINUTES AT CRUISE, THEN RETURNED TO 8.94K. THE RT FUEL QUANTITY REMAIN AT 8.94 DURING THIS TIME. REMOVED ICE AND RESIDUAL WATER FROM LT FUEL TANK. NR 1 FUEL QTY OPS NORMAL RESDR ASAA2013021993959Transceiver · failedNO ACARS PROMPT ON MCDU FOR SATCOM. R & R THE SATCOM TRANSCEIVER IAW AMM 23-15-00-000-801 AND PERFORMED SATISFACTORY TEST OF SATCOM IAW AMM 23-15-00-730-801.SDR ASAA2013021993952Shutoff Valve · failedAFTER DEPARTURE, DUCT PRESSURE INDICATED 55 PSI IN LT DUCT, 22PSI IN RT DUCT, GOT BETTER AS FLIGHT CONTINUED. REF MM 36-11-00-700-804, FOUND PRSOV BAD. REPLACED PRSOV REF MM 36-11-04-400-801. LEAK & OPS CHECKED GOOD. ACCOMPLISHED ENGINE BLEED AIR CROSSOVESDR ASAA2013021993947Light · inoperativeF/A REPORTS EMERGENCY LIGHT NEAR AFT LT LAVATORY INOPERATIVE. R & R EMERGENCY LIGHT IAW AMM 25-27-21.SDR ASAA2013021993946Connector · damagedWEATHER RADAR AURAL WARNING GO AROUND WINDSHEAR AHEAD VOLUME MUTED AND TOO QUIET. TEST VOLUME ALSO NOT THE SAME WITH SUBSEQUENT TEST PORTIONS ARE LOUDER THAN OTHERS, BUT NOT EVERY TIME. INTERMITTENT VOLUME CHANGES. FOUND WIRE MISPINNED ON CONNECTOR D189B (WESDR ASAA2013021993945Warning Light · false activationAFTER ENGINE START, NOTICED THE FMC DISAGREE LIGHTS ON. PERFORMED QRH 11.2, FMC MESSAGE NO LONGER DISPLAYED.SDR ASAA2013021993943Controller · malfunctionedCONT CAB ZONE TEMP ILLUMINATED ON RECALL AFTER ENGINE START. RACKED NR 2 ZONE TEMP CONTROLLER IAW 21-61-20 AND PERFORMED SATISFACTORY BIT CHECK OF NR 2 ZONE TEMP CONTROLLER IAW AMM 21-61-20.SDR ASAA2013021893939Idg · leakingDURING NR 2 ENGINE IDLE RUN, FOUND IDG PAD DRAIN TUBE DRIPPING 60 DROPS. REPLACED NR 2 ENGINE IDG AMM 24-11-11. LEAK AND OPS CHECKED GOOD.SDR ASAA2013021893938Satcom · malfunctionedSATCOM INOPERATIVE. NO SAT OPTION APPEARS ON FMC MENU PAGE. RESET POWER TO SATCOM BY PULLING & RESETTING SATCOM CIRCUIT BREAKER ON P18-2 PANEL. SAT OPTION RE-APPEARED ON FMC MENU AND SUCCESSFULLY CONTACTED DISPATCH ON BOTH SATCOM-1 & SATCOM-2, OPS NORMAL RESDR ASAA2013021793915Indicator · malfunctionedLT FUEL TANK DIGITAL QUANTITY INDICATOR WENT BLANK FOR 10 SECONDS, THEN CAME BACK ON. TOTALIZER SHOWED CORRECT AMOUNT OF FUEL. STABLE CRUISE AT FL 380. FUEL QUANTITY INDICATION SYS PASSED GROUND TEST REF MM 28-41-00-710-801. NO HISTORY PAST 30 DAYS.SDR ASAA2013021793909Controller · trippedLEFT PACK LT ILLUMINATES ON RECALL. INITIAL EVALUATION HAD A TCV FAULT ON NR 1 CONTROLLER. RESET CONTROLLER IAW MM 21-62 TASK 801. FAULT CLEARED.SDR ASAA2013021693914Compensator · contaminatedLEFT FUEL GAUGE READ 8600 - DROPPED TO 8200 AFTER FUELING - SAME NOTED ON CKPT GAUGES. ACFT GROUNDED. ACCOMPLISHED FQIS BITE PROCEDURE REF FIM 28-41-801, FOUND FAULT 28-41208, 2 TANK COMPENSATOR DATA BAD, NO FAULTS NOTED FOR TANK NR 1. FAULT HISTORY SHOWS FSDR ASAA2013021693912Drain Mast · crackedPOSSABLE CRACK IN HYD AND APU FUEL FEED DRAIN MAST. VERIFIED CRACK W HFEC JM 83433 NR 6. R & R DRAIN MAST REF MM 28-25-07.SDR ASAA2013021693908Warning Light · illuminatedDURING RECALL OF MASTER CAUTION LIGHT THE RT PACK LIGHT ILLUMINATED. ON RESET LIGHT EXTINGUISHED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST. NR 2 CONTROLLER FLAGGED RAM AIR ACT. (RT) FAULT IS INTERMITTENT. ABLE TO CLEAR WITH VERIFY. NO HISTORY PAST 3SDR ASAA2013021693907Heat Exchanger · failedLEFT PACK LEAKING BETWEEN HEAT EXCHANGER AND PLENUM. REMOVED LT ACM IAW MM 21-51-04-000-802-002. REMOVED LT HEAT EXCHANGER/PLENUM ASSY IAW MM 21-51-03-000-805-002. REPLACED BOTH (2) PRIMARY AND SECONDARY HEAT EXCHANGERS ASSY IAW MM 21-51-03-400-804-002. RESDR ASAA2013021693906Warning Light · false activationCONT CAB ZONE TEMP LIGHT ON. IAW FIM 21-62 / 842 C/W INIT EVAL - NO DEFECT NOTED, & C/W ZONE TEMP CONTROLLER BITE - NO DEFECT NOTED.SDR ASAA2013021593898Engine · fluctuatesAT CRUISE FL 200, FLUCTUATION IN NR 1 ENGINE N1 NOTED. COMPLIED WITH QRH PROCEDURES, REDUCED THRUST RETURNED N1 TO NORMAL CONDITION FOR DURATION OF FLIGHT. ACCOMPLISHED STEPS E. (4) & (5) OF FIM TASK 73-06, 809 IAW EA 800-71EA-09794 STEP 9. NO DISCREPANCIESDR ASAA2013021493917Shutoff Valve · inoperativeDURING CLIMBOUT DUCT PRESS LT 25, RT 45. AFTER LEVEL OFF LT DUCT PRESSURE STABILIZED TO 33 PSI. TOP OF DESCENT LT & RT DUCT EVEN AT 48. ACCOMPLISHED T/C NG-36WC-00001, BLEED SYS HEALTH CHECK. PRECOOLER VALVE FAILED, AND PRSOV FAILED TEST, NO OTHER DISCREPASDR ASAA2013021493919Oil Cooler · leakingAPU SHUTDOWN. PERFORMED FIM 49-90, TASK 801, HIGH OIL TEMP SHUTDOWN, FOUND OIL LEAKAGE AT OIL COOLER SUPPLY LINE. REPLACED APU OIL COOLER IAW AMM 49-91-41. NO LEAKS NOTED. PERFORMED APU BITE PROCEDURE IAW AMM 49-60, TASK 801, NO CURRENT FAULTS FOUND AND CDSDR ASAA2013021493918Apu · malfunctionedAPU FAULT LIGHT ON START. APU DID NOT LIGHT OFF AT ALL. RAN SYS TEST IAW FIM 49-40, TASK 803 STEP A THRU E ALSO STARTED APU 3 TIMES NO DEFECTS NOTED. SYS OPS CHECK GOOD.SDR ASAA2013021493916Valve · failedNR 1 ENG COWL VALVE OPEN LIGHT REMAINED BRIGHT WITH SWITCH IN THE ON POSITION TAI LIGHT ON UPPER DU WAS ILLUMINATED GREEN. ACCOMPLISHED FIM TASK 30-21, TASK 805 THRU STEP E (3)(A) PG2. LIGHT REMAINS ON BRIGHT. REPLACED ENG 1 COWL TAI VALVE NO LEAKS NOTED,SDR ASAA2013021493913Compensator · failedAT GATE RT MAIN FUEL GUAGE COUNTED DOWN FROM 8.5 TO 8.14 IN APPROX 30 SECONDS. NO FUEL LEAK VERIFIED. REPLACED TANK COMPENSATOR UNIT (RT) REF AMM 28-41-21. OPS CHECKED GOOD.SDR ASAA2013021493911Idg · failedCLIMBING OUT, AROUND 12,500 HAD THE MASTER CAUTION ILLUMINATE DUE TO NR 1 ENGINE SOURCE OFF LIGHT. THE DRIVE LIGHT ALSO ILLUMINATED AND COMPLETED THE CHECKLIST WHICH INCLUDED DISCONNECTING THE GENERATOR DRIVE. RETURNED TO DEPARTURE. R & R NR 1 IDG REF MM 2SDR ASAA2013021393876Apu · shutdownAPU SHUTDOWN AT GATE JUST PRIOR TO PUSHBACK. PERFORMED VISUAL INSPECTION OF APU. NO OIL LEAKS NOTED AND OIL LEVEL VISUALLY CONFIRMED TO BE FULL. PERFORMED FAULT ISOLATION PROCEDURES IAW FIM AR49-90-00-810-803. DURING MULTIPLE STARTS AND STOPS THERE WERE NO SDR ASAA2013021393875Radar · malfunctionedRADAR MANUAL & AUTO ANNUNCIATOR MISSING FROM ND. VERIFIED DISCREPANCY. RETURNED ACFT TO NORMAL REF SAME MM PROCEDURES. PERFORMED RELOAD OF DEU 1 & 2 OPC SOFTWARE REF 31-62-21. WX OPS & DISPLAY NORMAL REF 34-43-00. PERFORMED CDS DEU OPS REF 31-62-21. DEUSDR ASAA2013021293868Wire · damagedNR 2 COWL VALVE LIGHT GOES FROM BRIGHT, OFF AND DIM. POSITION IS INOPERATIVE. MANUALLY CYCLED RT COWL TAI VALVE, LIGHT GOES FROM BRIGHT TO DIM WITH ENG BLEED AIR, LIGHT GOES FROM BRIGHT TO OFF. REPLACED A/I VALVE REF MM 30-21-11-400, STEPS 3A-3H(5). FOUND WSDR ASAA2013021293869Warning Light · false activationON WINDOW, PITOT HEAT MODULE OVERHEAT LIGHT REMAINS ON FOR LT FWD AND RT SIDE WINDOWS. RESET SIX PACK AFTER TRYING SYS TEST AND EVERYTHING WENT TO NORMAL OPERATION. TRIED TO GET SYS TO FAIL AGAIN BUT IT WOULDNT FAIL. GROUND FUNCTIONAL GOOD IAW AMM 30-41-00SDR ASAA2013021193870Connector · looseWHILE IN CRUISE, AT FL360 DUCT SPLIT NOTED. LT 34 PSI N2 87.3, RT 8 PSI N2 87.1. TECH SERVICES REQUEST TO T/S AND REPAIR RT ENG PNEUMATIC SYS. ACFT GROUNDED. R & R THE FOLLOWING ON NR 2 ENGINE 390 PRECOOLER CONT SENSOR REF 36-12-03-000-801, 36-12-03-400-80SDR ASAA2013021193862Valve · malfunctionedDURING CLIMB FROM FLT 380 TO FL400 LEFT AC DUCT PRESSURE WAS 45PSI, RT PRESSURE WAS 19 PSI. (A 26 PSI DIFFERENCE ON LEVEL OFF FL 400 WITH POWERBACK AT CRUISE (90.4/90.2 N1 RESPECTIVELY) LT PSI WAS 37 PSI AND RT SIDE WAS 21 PSI. R & R HIGH STAGE REGULATOR, PRSDR ASAA2013021093854Module · failedAPU GEN INOPERATOR. GROUND RAN APU AND FOUND P5-4 PANEL GEN SWITCH FAULTY. REPLACED P5-4 PANEL, REF 24-21-51. GROUND RAN APU IAW 24-21-00. PERFORMED OWR OPS CHECKED. GROUND RAN ENGINES 1 AND 2. TRANSFERRED POWER MANY TIMES. APU DID NOT DROP OFF LINE.SDR ASAA2013021093853Servo · failedAUTOTHROTTLE TRIPPED OFF SHORTLY AFTER TOGA SELECTED ON TAKEOFF. NR 2 RT THRUST LEVER AHEAD OF LT AT TIME OF EVENT. WOULD NOT STAY ARMED WHEN RESELECTED IN FLIGHT. DUPLICATED DEFECT ON GROUND VERIFICATION, FOUND ASM NR 1 HARD FAIL. REPLACED NR 1 ASM REF SDR ASAA2013020993845Ground Wire · looseON PREFLIGHT, F/O FOUND LIGHT ON OVERHEAD ILLUMINATED, AUX BATTERY CHARGER FAULT NOTED. R & R MAIN AND AUX BATTERIES IAW AMM 24-31-11. R & R AUX BATTERY CHARGER IAW 24-31-31. PERFORMED BATTERY OPS CHECK IAW AMM 24-31-11, OPS CHECKED GOOD. PERFORMED AUX BATTSDR ASAA2013020993847Indication Sys · malfunctionedAT CRUISE, FL360, RT MAIN TANK WENT FROM 8.51 TO 8.13, THEN LATER 8.22 LT MAIN FROM 8.51 TO 8.94 CENTER WAS AR 14.74 TOTAL 31.9 ALL PUMPS ON 30 MIN LATER - RT MAIN 8.64 LM 8.94 CTR 13.77. CW FIM 28-41 814 FQIS BITE CURRENT STATUS = NO PRESENT FAULTS & GROSDR ASAA2013020893846Connector · looseNR 2 FUEL GAUGE LIGHT FLASHING IN UNDERWING FUEL PANEL. SEATED CONNECTOR ON NR 2 FUEL QUANTITY INDICATOR. REFUEL QUANTITY INDICATION SYS OPS CHECK GOOD. REF MM TASK 28-21, TASK 816.SDR ASAA2013020893844Warning Light · illuminatedLIGHT ILLUMINATED. CLEARED FAULT REF 24-31-TASK 801, OPS CK GOOD, NO FAULTS NOTED.SDR ASAA2013020893843Charger · inoperativeELEC LIGHT ILLUMINATED. ACFT GROUNDED. PERF ELEC LT MSG BITE PROC REF FIM 24-31-TASK 801 FOUND MAIT MSG FOR BATT CHG INOP. ABLE TO RESET MSG. PERF FIM 24-31 TASK 825 MAIT MSG CLEARED., VEFIRIED TWO GREEN LTS ON AUX BATT CHGR. FAULT DETERMINED TO BE INT GRND SDR ASAA2013020793850Unknown · unknownDIAGNOSTICS REPORTS NR 1 ENGINE CORE VIBRATION DATA INTERMITTENTLY REPORTS ZEROS FROM THE FRONT AND REAR SENSORS. AAVM STILL LOGS LOSS OF N2 SIGNAL, ALSO CDS LOGGED 31-63150, ENGINE 1 N2 RPM INVALID ON BOTH DEUS AS INTERMITTENT AND ON VARIOUS FLT LEGS. VERIFSDR ASAA2013020793849Shutoff Valve · failedDUE TO RECENT HISTORY OF THE RT ENG DUCT PRESS SPLITING DURING CLIMB (RT-18/ LT-44). THE RT PNEUMATIC SYS NEEDS TO BE CHECKED FOR OVER ALL HEALTH. ACCOMPLISHED T/C NG-36WC-00001, FOUND PRSOV OUT OF LIMIT. REPLACED PRSOV IAW AMM 36-11-04-400-801. OPS CHECKEDSDR ASAA2013020693878Power Supply · failedEMERGENCY LIGHTS POWER SUPPLY, M1676. R & R POWER SUPPLY AND TEST GOOD IAW AMM 33-51-06-960-806.SDR ASAA2013020693839Control Panel · crackedRADAR CONTROL PANEL CRACKED AROUIND IDNT BUTTON. REPLACED RADAR CONTROL PANEL, REF M/M 34-43-91. TESTS NORMAL.SDR ASAA2013020693838Terminal · miswiredLEFT SIDE WINDOW OVERHEAT LIGHT ILLUMINATED. COMPLETE QRH LIGHT EXTINGUISHED. ON DESCENT WINDOW OVERHEAT LIGHT ILLUMINATED AGAIN. C/W QRH. LT SLIDING WINDOW SENSOR FAILED FIM TASK 30-41-00-810-811, PG 4, PAR 6. RESISTANCE HIGH. SWAPPED WIRE TO SPARE TEMP SESDR ASAA2013020693837Autothrottle Sys · malfunctionedAUTOTHROTTLE LIM ANNUNCIATED ON UPPER DISPLAY UNIT. AUTOTHROTTLE OPS NORMAL WITH COMPUTED FMC LIMITS. AUTOTHROTTLE LIMIT RESPONDS TO MANUAL SELECTION ON FMC. FAULT CODE 223-220-00. ACCOMPLISHED AUTOTHROTTLE BITE IAW FIM 22-31, TASK 801. CURRENT STATUS SHOWSDR ASAA2013020693822Sensor · intermittentDIAGNOSTIC REPORTS NR 1 ENGINE CORE VIBRATION DATA INTERMITTENTLY REPORTS ZEROS FROM THE FRONT AND REAR SENSORS. ACFT GROUNDED. PERFORMED AAVM SYS BITE CHECK. BITE CHECK LOGGED N2 SENSOR LOSS OF SIGNAL FOR NR 1 ENG. REPLACED NR 1 ENG N2 SENSOR. OPS CK GOODSDR ASAA2013020593831Warning Light · false activationDURING TAKE OFF WITH TOGO 90N1 BOTH EEC LIGHTS CAME ON. LOW SPEED ABORT OF ABOUT 50 KNOTS. RETURNED TO GATE. PERFORMED EEC BITE PROCEDURE FOR NR 1 & 2 ENGINES IAW FIM 73-00 TASK 801, NO FAULTS NOTED. ACCOMPLISHED FIM 73-05, TASK 811, NO DEFECTS FOUND. ACC
Back to Boeing 737-890