SDR ASAA1058691Control Valve · failedRIGHT PACK LIGHT ILLUMINATES ON MASTER CAUTION RECALL. LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. REMOVED & REPLACED RIGHT PACK TEMP CONTROL VALVE. REF AMM 21 51 10 000 801 & 21 51 10 400 801 OPS CHECK GOOD.SDR ASAA1058693Fuel Control · failedAPU FAULT LIGKT W/2 START ATTEMPTS AND QRH CHECK LIST. FAULT CODE 49 41011 FCU RESOLVER. MAINT CODE 49 31175 FUEL FLOW DOES NOT MATCH SCHEDULE. REPLACED FCU ON APU. OPS CHECK/LEAK CHECK GOOD. REF MM 49 31 11. NO FAULTS FOUND.SDR ASAA1058692Unknown · malfunctionedUNABLE TO TRANSMIT OR RECEIVE ON HF1 RETURNED AT LEAST 4 TIMES. DATA SEEMED TO WORK INTERMITTANTLY. "NO COMM" MESSAGE DISPLAYED OFTEN DURING FLIGHT. HF2 WORKED FINE ON ALL FREQUENCIES. PERFORMED HF COMM SYSTEM TEST 23 11 00 NO FAULTS FOUND PERFORMED HF COMMSDR ASAA1058690Unknown · malfunctionedRIGHT PACK LIGHT ILLUMINATED W/RECALL CHECK. LIGHT WENT OUT W/MASTER CAUTION RESET PUSHED. NR 2 CTRLR SHOWS "TCV THIS PACK" ON BIT & PREV FLT TEST. VERIFY TEST GO. RESET FAULT. FAULT DID NOT RETURN. BITE TEST NR 2 CTRLR GOOD. REF FIM 21 62 T801. FUNCTSDR ASAA1058689Starter · failedSTARTED ENG NR 1 NORMALLY ENG NR 2 N2 WENT TO 15 PERCENT THEN ROLLED BACK TO 0 PERCENT N2 WITH START SWITCH IN "GROUND" AND "START VALVE OPEN" LIGHT ILLUMINATED. REMOVED AND REPLACED STARTER REF AMM 80 11 01. OPS CHECK GOOD.SDR ASAA1058688Starter · failedRT ENGINE WOULD NOT START. ZERO RPM SMOKE REPORTED FROM ENGINE. REMOVED RT ENGINE STARTER REF AMM 80 11 01 000 801 INSTALLED STARTER PER AMM 80 11 01 400 801 F00 OPS CHECK GOOD.SDR ASAA1058687Unknown · malfunctionedF/O FLIGHT DISPLAY NOT SHOWING V SPEEDS. FOUND RT FMC INOP MAP FLAG ON F/O'S SIDE. PERFORMED FIM 34 61 TASK 807. RT FMC OPS RESTORED. ETOPS GROUND VERIFICATION TEST SUCCESSFUL.SDR ASAA1058669Strip · brokenMAIN CABIN LT SIDE ESCAPE PATH LIGHTING HAS A PIECE BROKEN BY THE AFT LT LAVATORY. REMOVED AND REPLACED MAIN CABIN LT ESCAPE PATH LIGHTING STRIP IAW B737 MM 33 51 15 960 801.SDR ASAA1058666Unknown · malfunctionedPERFORMED TASK CARD 78273000 "INTERROGATE THE FMC CDU FOR ENGINE FAULTS" NR 1 ENGINE HAD CODE 73 31711 / NR 2 ENGINE HAD CODE 73 31712 BOTH ARE "ADIRU 1 TAT DATA AND ADIRU 2 TAT DATA DISAGREE" SHORT TERM FAULT. PERFORMED FIM 73 28 TASK 808 EEC TEST PASSES FORSDR ASAA1058664Unknown · malfunctionedLEFT SIDE WINDOW OVERHEAT LIGHT ON.UNABLE TO CONFIRM DISCREPANCY KEPT SYSTEM ON FOR 45 MINUTES THEN 30 MINUTES LATER ON IN EVENING NEVER HAD OVERHEAT LIGHT COME ON. PERFORMED GROUND VERIFICATION CHECK IAW MM 30 41 00 710 801 OPS CHECK GOOD.SDR ASAA1058665Unknown · malfunctionedFMC DISAGREE AFTER PUSH BACK. ACCOMPLISHED FMC DISAGREE FAULT ISOLATION PER FIM 34 61 00 810 835, NO FAULT AFTER 5 MIN A/C OK FOR SERVICE.SDR ASAA1058653Converter · failedDURING THE EEP CHECK THE APU GEN VOLTS & FREQS SHOWING 0 FREQS AND 2 VOLTS. DIVERSION TIME 121 MINUTES. VERIFIED DISCREPANCY. PERFORMED APU AND GCU BITE. NO FAULTS NOTED. REMOVED AND REPLACED APU START CONVERTER PER AMM 49 41 61. OPS NORMAL. APU GEN BUS SDR ASAA1058652Converter · faultyAPU WILL NOT START. (NOTE: ON BATTERY PWR) CHANGED A/C MAIN BATTERIES, NO HELP. CHANGED START CONVERTER UNIT REF AMM 49 41 61 000 801 AND AMM 49 41 61 400 801. OPS NORMAL. REF AMM 24 31 11 FOR BATTERIES OPS NORMAL PER SAME.SDR ASAA1058651Unknown · malfunctionedGOT FAIL LIGHT ON NR 2 HF. REBOOTED HF 2 PERFORMED FIM 23 11 00 810 803 BITE TESTED PER MM 23 11 00 810 801 TESTS OK, NO HISTORY.SDR ASAA1058667Gearbox · making metalWHILE ACCOMPLISHING T/C 78472040 AGB/TGB CHIP DETECTORS INSPECTION FOUND ALUMINUM DEBRIS IN NR 1 ENGINE AGB/TGB CHIP DETECTOR. NR 1 ENGINE AGB TGB CHIPS DETERMINED TO BE SILVER FLAKING NO MAGNETIC MATERIAL NOTED. CHIPS ROUTED FOR LAB ANALYSIS. ENGINE MAY COSDR ASAA1058656Sensor · failedLEFT SIDE WINDOW HOT. CORRESPONDING OVERHEAT LIGHT ILLUMINATED AFT OVERHEAD PANEL. T/S: WINDOW OHMS GOOD TAP IS CORRECT BITE SHOWS WINDOW SENSOR FAULT IN HISTORY. REMOVED WINDOW CHANGED WIRE TO SPARE SENSOR RE-INSTALLED WINDOW. OPS TEST REF 30 41 00 OPS NSDR ASAA1058655Controller · faultyLEFT SIDE WINDOW OVERHEAT LIGHT ILLUMINATED. WHILE WINDOW OVERHEAT LIGHT WAS ILLUMINATED WINDOW HEAT CONT SHOWS NO FAULTS. REMOVED & REPLACED LT SIDE WINDOW HEAT CONTROLLER REF MM 30 41 11. GROUND VERIFICATION TESTS PASSED.SDR ASAA1058654Pin · backed outLEFT SIDE WINDOW OVERHEAT LIGHT ILLUMINATED. AFTER TURNING SWITCH OFF FOR TWO MINUTES AND BACK TO ON OVER HEAT LIGHT EXT. ON LIGHT REILLUMINATED AFTER 1 MINUTE WITH SWITCH ON. WINDOW HEAT BITE CHECK LOGGED SENSOR FAULT. NO CURRENT FAULTS. PERFORMED FIM 30SDR ASAA1058648Idg · defectiveON WALK AROUND NR 1 ENG IDG DELTA P INDICATORS (RED BUTTON) POPPED. CHECKED HISTORY FOUND 3 NUISANCE FAULTS THIS IS THE 4TH NUISANCE FAULTS PER FIM 24 11 00 810 803 THE IDG NEED TO BE REPLACED. REMOVED AND REPLACED ENG NR 1 IDG. PER MM 24 11 11 000 & 24 11 SDR ASAA1058647Unknown · malfunctionedDURING TAXI OUT FMC DISAGREE ILLUMINATED. FOLLOWED QRH CHECKLIST LIGHT EXTINGUISHED. OPS NORMAL.SDR ASAA1058643Unknown · malfunctionedLT "PACK" LIGHT ON RECALL CLEARS WITH MASTER CAUTION RESET. RESET LEFT RAM AIR SENSOR FAULT LIGHT GROUND VERIFICATION OPS NORMAL REF MM 21 62 00 810 801. NO PREVIOUS FLT'S FAULTS AND NO HISTORY LAST 60 DAYS.SDR ASAA1058646Unknown · malfunctionedAFTER START DURING RECALL CONT CAB ZONE TEMP ANNC ILLUMINATED. RESET MASTER CAUTION ANNC LIGHT EXTINGUISHED. NR 2 TEMP CTRLR SHOWS "FLT DECK TRIM VALVE" FAULT ON BIT & PREV FLT TESTS. VERIFY TEST GO. RESET FAULT. FAULT DID NOT RETURN. INTERMITTENT FAULT.SDR ASAA1058645Acm · malfunctionedVERY STRONG DIRTY SOCK ODOR DURING CLIMBOUT AND DESCENT. DID NOT OCCUR DURING CRUISE. FOUND SMELL COMING FROM LT PACK. FOUND LT PACK ACM BAD. REMOVED REPLACED ACM REF AMM 21 51 04. REPLACED LT PACK O-ZONE CONVERTER REF AMM 21 73 01. ALL WORK ACCOMPLISHEDSDR ASAA1058644Transmitter · failedDURING TAXI OUT THE NR 2 ENGINE OIL FILTER BYPASS LIGHT CAME ON TWICE THEN WENT OUT. REPLACED SCAVENGE OIL FILTER CLOGGING TRANSMITTER REF MM 79 21 07 000 801 F00 & 79 21 07 400 801 F00. RAN MOTOR FOR 5 MIN OPS CHECK & LEAK CHECK GOOD. NEW FILTER & O-RINGS SDR ASAA1058642Unknown · malfunctionedTHE "ZONE TEMP" LIGHT ILLUMINATED FOR "CONT CAB" AFTER ENGINE START AND 'RECALL" ON CHECKLIST. FOLLOWED QRH LIGHT RESETS WITH SIX PACK PUSH. ACCOMPLISHED TASK 21 61 00 PACK/ZONE TEMP CONTR. BITE OPS CHECK NORMAL.SDR ASAA1058641Unknown · malfunctionedUPON RECALL LEFT PACK LIGHT ILLUMINATED. RESET VIA MASTER CAUTION RESET BUTTON OK. LIGHT ILLUMINATES ON RECALL. NR 1 TEMP CTRLR SHOWS "TCV THIS PACK" FAULT ON BIT AND LAST FLT. VERIFY TEST GO. RESET FAULT. FAULT DID NOT RETURN. FUNCT CHECK LT PACK GOOD. SDR ASAA1058628Unknown · malfunctionedNR 2 ENGINE HAS LONG TERM FAULTS: MESSAGE NR 73 10122 INTERNAL EEC FAULT MESSAGE NR 73 10812 THE T12 SIGNAL IS OUT OF RANGE. MESSAGE NR 75 10822 THE T25 SIGNAL IS OUT OF RANGE. MESSAGE NR 75 10832 THE T3 SIGNAL IS OUT OF RANGE. MESSAGE NR 77 10842 : THE TSDR ASAA1058626Actuator · malfunctionedAT 2.5 HRS INTO CRUISE FLIGHT CROSSFEED VALVE CIRCUIT BREAKER POPPED. REMOVED & REPLACED ACTUATOR OF THE ENG FUEL CROSSFEED VLV PER MM 28 22 21 OPS OK.SDR ASAA1058625Circuit Breaker · trippedAUTO THROTTLE WILL NOT ARM. FOUND "AFCS A WARN LIGHT (BAT)" CB OUT. CHECKED BEHIND P18 1 FOR CONTAMINATION OR DEFECTS NONE NOTED. RESET CB REF MM 20 60 01. ACCOMPLISHED DFCS BITE 30 & 49 & HGS TEST REF MM 34 36 00. BOTH OPS NORMAL.SDR ASAA1058624Actuator · failedDURING CLIMBOUT LEFT RAM DOOR FULL OPEN LIGHT REMAINED ILLUMINATED. FOLLOWED BY LEFT PACK ILLUMINATING. QRH CHECKLIST COMPLETED. LIGHTS EXTINGUISHED. OPS NORMAL. ON DEFERRAL. DURING CLIMB OUT LEFT RAM DOOR FULL OPEN LIGHT REMIANED ILLUMINATED. FOLLOWED BSDR ASAA1058620Display · malfunctionedCDU SHOWS "SINGLE FMC OPERATION". PERFORMED NAV DATA CROSSLOAD. PERFORMED FIM 34 61 00 810 807. TESTS OK.SDR ASAA1058619Display · damagedF/O'S MCDU (FMC) BUTTON R6 RUBBER TORN. REMOVED & REPLACED F/O'S MCDU REF MM 34 61 01 400 802, OPS NORMAL.SDR ASAA1058617Unknown · malfunctionedNR 2 ENGINE GENERATOR NO VOLTS NO FREQS. PERFORMED OPERATION TEST 24 11 00 IT PASSED. GROUND VERIFICATION OF NR 2 ENG GENERATOR OPS CHECK GOOD.SDR ASAA1058616Unknown · malfunctionedAFTER ENGINE START FMC DISAGREE LIGHT ILLUMINATED. ACCOMPLISHED CHECKLIST. FMC RETURNED NORMAL OPS.SDR ASAA1058618Unknown · malfunctionedFMC DISAGREE ILLUMINATED. PERFORMED QRH TASK OPS NORMAL.SDR ASAA1058603Pressure Switch · failedCABIN OXYGEN DROP FAILED AUTOMATIC ACTUATION TEST. REMOVED AND REPLACED ALTITUDE PRESSURE SWITCH.SDR ASAA1058602Floor Support · corrodedFWD CARGO COMPARTMENT RT FLOOR SUPPORT ZEE CHANNEL IS CORRODED FROM STA500E TO 500I. REPLACED WITH NEW ZEE CHANNEL.SDR ASAA1058615Apu · malfunctionedDESCENDING THROUGH 5000 FEET SOUR "DIRTY SOCKS" SMELL PRESENT IN FLT DECK. CONFIRMED APU IS THE SOURCE OF CABIN ODOR REF TASK 05 60 00 280 801C1. ALSO RAN BOTH PACKS WITH BOTH ENGINES. SMELL ONLY RETURNED WHEN APU WAS SELECTED. REMOVED AND REPLACED APU PERSDR ASAA1058604Skin · corrodedCORROSION ON AFT LEFT LEFT FUSELAGE. REMOVED CORROSION AND REPLACED RIVETS.SDR ASAA1058614Shield · looseF/O'S FMC FROZEN. RE-TERMINATED SHIELD THAT GOES TO GB524. RE-TERMINATED 2504R 24 & 2504B 24 AT D2179A REF WDM 34 61 11 PAGE 4 SHEET 2. OPS CHECKED GOOD REF AMM 34 61 00.SDR ASAA1058600Unknown · malfunctionedRIGHT FMC FAIL DUAL OPS NOT RE-STORED. EXPANDED DETAILS: LNAV WOULD DROP TO CWS NO R FMC INFO ON POSITION PAGE 3 (FNC ) BLANK.AFTER 20 MIN " MAP" DISPLAY ON F/O SIDE DID NOT GET "VTK". PERFORMED FIM TASK 34 61 00 810 836 INITIALK EVALUATION. NO FAULTS FOUSDR ASAA1058605Trans Panel · corrodedTRANSITION PANEL CORRODED AND DENTED 500B+12 TO 500I. REMOVED AND REPLACED PANEL.SDR ASAA1058598Unknown · malfunctionedPWS FAIL ON CAPT AND F/O ND SWITCHED POWER SOURCE AND STILL HAD PWS FAIL/ WXR FAIL. CYCLED C/B WXR RT PER MM 20 10 05. PERFORMED WEATHER RADAR FIM CHECK PER 34 43 00 OPERATIONAL CHECK NORMAL.SDR ASAA1058597Outflow Valve · failedAFTER LANDING OUTFLOW VALVE STAYED CLOSED AND PRESURIZED THE A/C, WENT TO MANUAL AND OPENED THE VALVE, WENT BACK TO AUTO AND AGAIN THE VALVE CLOSED. LEFT IN MANUAL OPEN. NR 2 PRESS CNTLR SHOWS FAULT OFV LRU FAIL FAULT CODE 009. FLTS 00 ANDC 01 SHOW 090 FAULTSDR ASAA1058601Seal · crackedLEFT WING FIXED TRAILING EDGE LOWER SURFACE INBOARD FIXED TRAILING EDGE SEAL CRACKED AROUND FASTENER NUTS. REMOVED AND REPLACED FITTING.SDR ASAA1058587Unknown · malfunctionedAPU ELECTRICS DROPPED OFF LINE 2 TIMES. GVI ON APU NO DEFECT FOUND. APU GCU LRU TEST PASSED. APU BITE NO CURRENT FAULT NO RELATED FAULT FOUND ON FAULT HISTORY & NO HISTORY IN TRAX. PERFORMED OPERATIONAL TEST FOR AC GENERATION & CONTROL SYSTEM REF MM 24 21 SDR ASAA1058613Stop Fitting · gougedL2 AFT ENTRY DOOR TOP FWD STOP FITTING GOUGED. CONTACT DAMAGE WITH DOOR JAMB STOP FITTING TOP BOLT. REMOVED AND REPLACED STOP FITTING.SDR ASAA1058592Floor Support · corrodedFWD CARGO COMPARTMENT FLOOR SUPPORT ANGLE AT STA 500I LBL 22 IS CORRODED. REMOVED AND REPLACED FLOOR SUPPORT ANGLE.SDR ASAA1058585Unknown · malfunctionedON RECALL GOT A PACK (RIGHT) LIGHT THAT GOES OUT WHEN RESET IS PUSHED (MASTER CAUTION). NR 2 CTRLR SHOWS "TCV THIS PACK" FAULT LAST FLT. RESET FAULT. FAULT DID NOT RETURN. INTERMITTENT FAULT. GND VERIFICATION TEST GOOD. REF FIM 21 62 T801 & 21 62 T831. SDR ASAA1058584Guide Arm · out of adjustFOUND L1 DOOR NOT PARALLEL WITH DOOR CUTOUT IN FINAL STAGES OF CLOSING MAKING DOOR DIFFICULT TO CLOSE ADJ. L1 DOOR GUIDE ARM ADJUSTMENT PER B737 800 MM 52 11 00 820 801 STEP H PAGES 2 AND 3. DOOR NOW CLOSES NORMALLY.
Back to Boeing 737-890