What was found
WHILE ACCOMPLISHING T/C 78472040 AGB/TGB CHIP DETECTORS INSPECTION FOUND ALUMINUM DEBRIS IN NR 1 ENGINE AGB/TGB CHIP DETECTOR. NR 1 ENGINE AGB TGB CHIPS DETERMINED TO BE SILVER FLAKING NO MAGNETIC MATERIAL NOTED. CHIPS ROUTED FOR LAB ANALYSIS. ENGINE MAY CONTINUE IN SERVICE WITH A REDUCED MCD INSPECTION INTERVAL AT 50-75 HOURS RETURN TO NORMAL INSPECTION INTERVAL WHEN THE MCD IS FOUND TO BE CLEAN REF MM 79-00-00-200-804-F00. AGB/TGB CHIP DETECTOR INSPECTED AND FOUND CLEAN, NO METAL. PLT CLEARED. RETURN TO NORMAL INSPECTION INTERVAL.