Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2025010272136Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BTW BS 380 TO BS 400 RBL 41 WL 208.1 AT PASSENGER CABIN 2024-728433<[01] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BTW BS 380 TO BS 400 RBL 41 WL 208.1 AT PASSENGER CABIN I.A.W B737-800 SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND SDR SWAA2025010271956Web · crackedCRACK ON INTERCOSTAL WEB BTW BS 344 TO BS 360 BL 0 WL 208.1 AT FWD GALLEY AREA 2024-728421<[01] REPLACED INTERCOSTAL WEB LOCATED FLOOR STRUCTURE BTW BS 344 TO BS 360 BL 0 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02 AND DRAWING 141A5400 SHEET 32 REV - SEE INDISDR SWAA2025010272137Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED FLOOR STRUCTURE BTW BS 380 TO BS 400 LBL 14 WL 208.1 AT PASSENGER CABIN 2024-728434<[01] REPLACED ANGLE AND FASTENERS LOCATED FLOOR STRUCTURE BTW BS 380 TO BS 400 LBL 14 WL 208.1 AT PASSENGER CABIN IAW B737-800 SRM-51-40-02-0G-0 SDR SWAA2024123171953Floor Support · crackedCRACK ON WEB LOCATED BTW BS 277 TO BS 294.5 RBL 1 AT FWD GALLEY AREA. REPLACED WEB INTERCOSTAL AND FASTENERS LOCATED BTW BS 277 TO BS 294.5 RBL 1 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02-OG-0. AND DRAWING 141A5400; SHEET 20; REV-.SDR SWAA2024123171954Structure · crackedCRACK ON INNER CHORD LOCATED BS 303.9 LBL 54 WL 208.1 AT FWD GALLEY. REPLACED INNER CHORD AND FASTENERS LOCATED ON BS270 TO BS360 WL 208.10 BTW STR 17L AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02. SRM 51-10-02 Ï¿½TEM 9. DWG 141A8110 SHEET 9 REV:A. DWG 141A8SDR SWAA2024123171955Web · crackedCRACK ON WEB LOCATED BTW BS 312 TO BS 328 LBL 47.5 WL 208.1 AT FWD GALLEY AREA. REPLACED WEB AND FASTENERS LOCATED BTW BS 312 TO BS 328 LBL 47.5 WL 208.1 AT FWD GALLEY AREA IAW B737-800 SRM-51-40-02-0G-0 AND DRAWING 141A5400 SHEET 26; REV-.SDR SWAA2024123172141Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222AF AT FWD GALLEY AREA. REPLACED FLOOR PANEL 222AF IAW B737-800 AMM 53-21-00-400-801 THE INSTALLATION IS DOCUMENTED ON TASK TTG8Q00WL0W3SDR SWAA2024123172142Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222BF AT FWD GALLEY AREA. REPLACED FLOOR PANEL 222BF AT FWD GALLEY AREA WILL BE INSTALLED ON OTHER TASK CARD SEE TTG8Q00WL0W1.SDR SWAA2024123172143Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222BF AT FWD GALLEY AREA. DELAMINATED FLOOR PANEL 222CF AT FWD GALLEY AREA. REPLACED FLOOR PANEL 222CF AT FWD GALLEY AREA THE INSTALLATION IS DOCUMENTED ON TASK TTG8Q00WL1RS.SDR SWAA2024123172144Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222DF AT FWD GALLEY AREA. REPLACED FLOOR PANEL 222DF AT FWD GALLEY AREA THE INSTALLATION IS DOCUMENTED ON TASK TTG8Q00WL1RQ.SDR SWAA2024123172145Floor Panel · delaminatedDELAMINATED FLOOR PANEL 221CF AT FWD GALLEY AREA. REPLACED FLOOR PANEL 221CF AT FWD GALLEY AREA THE INSTALLATION IS DOCUMENTED ON TASK TTG8Q00WL1S2.SDR SWAA2024123172146Floor Panel · delaminatedDELAMINATED FLOOR PANEL 221BF AT FWD GALLEY AREA 2024-728437<[01] REPLACED FLOOR PANEL 221BF IAW B737-800 AMM 53-21-00-400-801 THE INSTALLATION IS DOCUMENTED ON TASK TTG8Q00WL1S4;[02] REPLACED FLOOR PANEL 221BF IAW B737-800 AMM 53-21-00-400-801 THE INSTALLATIOSDR SWAA2024123172148Floor Panel · delaminatedDELAMINATED FLOOR PANEL 221EF AT FWD GALLEY AREA 2024-728442<[01] REPLACED FLOOR PANEL 221EF IAW B737-800 AMM 53-21-00-400-801 THE INSTALLATION IS DOCUMENTED ON TASK TTG8Q00WL1RY;[02] CERTIFIED WORK PERFORMED. <BR>FOR INSTALLATION SEE TTG8Q00WL1RY.SDR SWAA2024122772047Bracket · crackedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE INTERCOSTAL WEB; FWD CLIP/BRACKET CRACKED @ STA 400. (MARKED)<[01] REMOVED AND REPLACED PER SRM 51-40-02.SDR SWAA2024122771918Angle · corrodedFWD ENTRY DOOR THRESHOLD L-ANGLE VERTICAL LEG AT STA 312 LBL 52 HAS CORROSION.(MARKED)<[01] BLENDED AREA OF CORROSION ON FWD ENTRY DOOR THRESHOLD L-ANGLE VERTICAL LEG AT STA 312 LBL 52; BLEND FOUND TO BE OUT OF LIMITS ALL IAW SRM 53-10-15-1A-1.;[02] REMOVED; LSDR SWAA2024122771915Angle · corrodedFWD ENTRY DOOR THRESHOLD L-ANGLE HORIZONTAL LEG AT STA 328+12 LBL 56 HAS CORROSION.(MARKED)<[01] BLENDED AREA ON FWD ENTRY DOOR THRESHOLD L-ANGLE HORIZONTAL LEG AT STA 328+12 LBL 56; BLENDS FOUND TO BE OUT OF LIMITS ALL IAW SRM 53-10-15-1A-1.;[02] REMOVED AND SDR SWAA2024122772048Web · corrodedFWD CARGO COMPARTMENT; SCUFF PLATE WEB HAS SURFACE CORROSION AROUND FASTENERS HOLES.<[01] LOCATED AND DRILLED HOLES FOR NUT PLATES. ALODINE AND PRIMED HOLES. INSTALLED NEW NUT PLATES IAW SRM 51-40-02;[02] REMOVED OLD WEB AND ALLOCATED HOLES ON NEW SERVICEABLE SDR SWAA2024121872029Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500A-500B AROUND FASTENER HOLES.<[01] THE CORROSION IS OUT OF LIMIT PER SRM 53-00-53-1A-2.;[02] REMOVED FWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE STA.500A TO 5SDR SWAA2024121872040Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500B-500C AROUND FASTENER HOLES.<[01] TOOL UPDATE.;[02] THE CORROSION IS OUT OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED FWD CARGO RH TRANSITION ANGLE BETWSDR SWAA2024121872031Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500C TO 500D AROUND FASTENER HOLES.<[01] TOOL UPDATE.;[02] THE CORROSION IS OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED FWD CARGO RH TRANSITION ANGLE BETWESDR SWAA2024121872032Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500D TO 500E AROUND FASTENER HOLES.<[01] TOOL UPDATE.;[02] THE CORROSION IS OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED FWD CARGO RH TRANSITION ANGLE BETWESDR SWAA2024121872033Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500E TO 500F AROUND FASTENER HOLES.<[01] TOOL UPDATE.;[02] THE CORROSION IS OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED FWD CARGO RH TRANSITION ANGLE BETWESDR SWAA2024121872045Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500F TO 500G AROUND FASTENER HOLES.<[01] TOOL UPDATE.;[02] THE CORROSION IS OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED FWD CARGO RH TRANSITION ANGLE BETWESDR SWAA2024121872034Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 500H TO 500I AROUND FASTENER HOLES.<[01] TOOL UPDATE.;[02] THE CORROSION IS OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED FWD CARGO RH TRANSITION ANGLE BETWESDR SWAA2024121872035Intercostal · crackedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE INTERCOSTAL WEB HAS CRACK @ STA 400. (MARKED)<[01] FABRICATED INTERCOSTAL WEB/BAFFLE P/N 143A7510-39 PER GRANTED SMAL AND BOEING DWG 143A7510.;[02] VERIFIED WORK COMPLETED IN CORRECTIVE ACTION #1 PER GRANTSDR SWAA2024121872038Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 480-500 AROUND FASTENER HOLES.<[01] BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT SRM 53-00-53-1A-2.;[02] REMOVED FWD CARGO COMPARTMENT L/H TRANSITION ANGLE FROM STA 400SDR SWAA2024121872039Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500-500A AROUND FASTENER HOLES. BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2. L/H TRANSITION ANGLE BEING REPLACED FROM BS 400 - 500I ON TTG8Q00SDR SWAA2024121872027Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500A-500B AROUND FASTENER HOLES. BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2. TRANSITION ANGLE REPLACED FROM BS 400 - 500I ON TTG8Q00XLZZH. PERSDR SWAA2024121872028Plate · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500B-500C AROUND FASTENER HOLES. BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2. LT TRANSITION ANGLE REPLACED FROM BS 400 - 500I ON TTG8Q00XLZZH. SDR SWAA2024121872030Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500H TO 500 I AROUND FASTENER HOLES. BLENDED THE CORROSION; FOUND TO BE OUT OF LIMIT I.A.W SRM 53-00-53-1A-2. LT TRANSITION ANGLE REPLACED FROM BS 400 - 500I ON TTG8Q00XLZSDR SWAA2024121872041Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500G TO 500H AROUND FASTENER HOLES. BLENDED THE CORROSION; FOUND TO BE OUT OF LIMIT I.A.W SRM 53-00-53-1A-2. LT TRANSITION ANGLE REPLACED FROM BS 400 - 500I ON TTG8Q00XLZZSDR SWAA2024121872042Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500F TO 500G AROUND FASTENER HOLES.<[01] TOOL UPDATES.;[02] BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.SDR SWAA2024121872043Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500E TO 500F AROUND FASTENER HOLES.<[01] TOOL UPDATES.;[02] BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.SDR SWAA2024121872044Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500D TO 500E AROUND FASTENER HOLES.<[01] TOOL UPDATES.;[02] BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.SDR SWAA2024121872046Attach Angle · corrodedFWD CARGO COMPARTMENT FLOOR STRUCTURE; ATTACH ANGLE CORRODED SEVERAL PLACES STA 500 I BETWEEN STRINGER 26 L AND 26 R AROUND FASTENER HOLES.<[01] THE CORROSION IS OUT OF LIMIT PER SRM 53-30-08-1A-1. REMOVED FWD CARGO COMPARTMENT FLOOR STRUCTURE; ATTACH ANGLE SDR SWAA2024112771859Battery Pack · inoperativeEMERGENCY LIGHT BATTERY INOP (STA727C+13 WL212 LBL68)<[01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY (STA727C+13 WL212 LBL68) IN REFERENCE WITH AMM 33-51-06. OPS CHECK GOOD AT THIS TIME.SDR SWAA2024112771840Light · inoperativeEMERGENCY LIGHT INOP OUTSIDE OF AFT LEFT SERVICE DOOR<[01] RELAMPED AFT LEFT SERVICE DOOR EXT EMER LITE PER AMM 33-51-04.SDR SWAA2024112772246Lens · out of adjustMID CABIN OVERHEAD EMERGENCY EXIT SIGN COVER LENS CAME OFF<[01] RESECURE AFT LENS ON MID CABIN EXIT SIGN PER SIPSDR SWAA2024112772134Battery Pack · inoperativeR/H AFT EXTERIOR OVER WING EMERGENCY EXIT LIGHT INOP.<[01] REMOVED AND REPLACED EMERGENCY BATTERY PACK I.A.W AMM 33-51-06. OPS CHECK GOOD.;[02] VERIFIED REMOVED AND REPLACED EMERGENCY BATTERY PACK I.A.W AMM 33-51-06. OPS CHECK GOOD.SDR SWAA2024122771542Floorbeam · corrodedPOSSIBLE HIDDEN CORROSION UNDER GALLEY TIEDOWN FITTING AT STA 947 RBL 224.<[01] C/W DAMAGE CUTOUT PER NDT MANUAL PART 6 51-00-00 PROCEDURE 23. NO DEFECTS NOTED.;[02] ACCOMPLISHED HOLE PROBE INSPECTION OF EXISTING FASTENERS COMMON TO REPAIR PER NDT MANUAL PART SDR SWAA2024122771541Beam · corrodedLIGHT CORROSION ON LONGITUDINAL STUB BEAM LOCATED AT STA 947+3 RBL 24.(MARKED)<[01] REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS REMOVED .030? FROM .071. OUT OF LIMITS PER SRM 53-70-51-1A-1.;[02] REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS REMOVED .030?SDR SWAA2024122071571Angle · crackedL/H ECS BAY AFT AREA; ANGLE ATTACHED TO THE LOWER REAR SPAR CRACKED AT BS 663 APPROX. LBL-40.<[01] REMOVED LH VAPOR BARRIER ATTACHMENT ANGLE; VAPOR BARRIER CHANNEL SUPPORT FROM STA LBL45 TO LBL 65; STIFFENER AT STA LBL33 APPOX; AND FITTING AT LBL 70; FORMED LHSDR SWAA2024122071573Attach Angle · crackedR/H ECS BAY AFT AREA; ANGLE ATTACHED TO THE LOWER REAR SPAR CRACKED AT BS 663 APPROX. RBL-40<[01] REMOVED RH VAPOR BARRIER ATTACHMENT ANGLE; VAPOR BARRIER CHANNEL SUPPORT FROM STA RBL45 TO RBL 65; STIFFENER AT STA RBL33 APPOX; AND FITTING AT RBL 70; FORMED RH SDR SWAA2024122071578Flap · delaminatedR/H WING O/B AFT FLAP DELAMINATED AT THE I/B AFT CORNER.<[01] REMOVED DELAMINATED R/W I/B AFT FLAP (PN:113A3700-28 SN:005141); RECEIVED NEW R/W I/B AFT FLAP (PN:113A3700-8 SN:000362); FOUND TO BE BAD FROM STOCK. R/W I/B AFT FLAP (PN:113A3700-8 SN:000362) TO BESDR SWAA2024121371711Scuff Plate · crackedAFT CARGO DOOR FWD CORNER SCUFFPLATE (PN 146A8341-7) IS CRACKED<[01] REMOVED DAMAGED CORNER SCUFF PLATE AND INSTALLED NEW SERVICEABLE CORNER SCUFF PLATE PER AMM 53-11-02.;[02] VERIFIED. REMOVED DAMAGED CORNER SCUFF PLATE AND INSTALLED NEW SERVICEABLE CORNER SCSDR SWAA2024121371712Scuff Plate · crackedFWD CARGO DOOR FWD CORNER SCUFFPLATE (PN 143A8331-3) IS CRACKED<[01] INSTALLED NEW FWD CARGO DOOR CORNER SCUFFPLATE PER AMM 53-11-02;[02] VERIFIEDSDR SWAA2024112971451Strip · looseFLOOR EGRESS ILLUMINATION STRIP AT ROW 2 LIFTING FROM FLOOR<[01] FOUND APPROX 2 IN SECTION LIFTING FROM FLOOR. SECURED WITH 3 IN OF TAPE. OK TO CONTINUE PER MEL 33-19-01 SP-1;[02] RESECURED FLOOR EGRESS ILLUMINATION STRIP AT ROW 2 IAW SIP.SDR SWAA2024112671193Flashlight · inoperativeONE FORWARD FLIGHT ATTENDANT FLASHLIGHT INOP<[01] REPLACED BATTERY REF AMM 25-64-00SDR SWAA2024112671386Battery Pack · inoperativeFWD RH EMERGENCY LIGHTS INOP<[01] REMOVED AND REPLACED EMERGENCY BATTERY PACK LOCATED AT ROW 8DEF PER AMM 33-51-06. OPS CHK GOODSDR SWAA2024112671271Seal · crackedRIGHT; AFT; UPPER SLIDING SEAL IS CRACKED ON THE HORIZONTAL STABILIZER.<[01] R&R RH HORIZONTAL STAB AFT UPPER SLIDING SEAL REF. SRM 51-40-02.
Back to Boeing 737-8H4