What was found
FWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500F TO 500G AROUND FASTENER HOLES.<[01] TOOL UPDATES.;[02] BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 500F TO 500G AROUND FASTENER HOLES.<[01] TOOL UPDATES.;[02] BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.