Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023101601494Door · out of adjustL1 DOOR IS SAGGING AT FWD UPPER GAP LESS THAN 0.060 INCH.<[01] PERFORMED L1 DOOR ADJUSTMENT REF AMM 52-11-00-820-801. CALIPER USED 175310-R DD: 26-MAY-24; FORCED GAUGE USED 159992 DD: 28-MAR-24.;[02] REMOVED AND REPLACED UPPER AND LOWER PLATE BEARINGS DOOR DOESDR SWAA2023092101312Battery Pack · failedRH AFT (R2 DOOR) EMERGENCY LIGHTS WILL NOT ILLUMINATE<[01] REPLACED THE BATTERY PACK; LIGHTS TEST NORMAL. IWA AMM 33-51-06;[02] SEE TTG8Q00MLVD5 (LINE 794) FOR PARTS REQUIREMENT;[03] INSPECTION C/WSDR SWAA2023092001664Flap · lockedMOVED FLAP HANDLE TO 5; NO MOVEMENT OR FLAPS OR LEADING EDGE DEVICES; PLACED HANDLE BACK TO 0; PREPARED FOR ALTERNATE EXTENSION; AFTER PLACING FLAP HANDLE TO 5; FLAPS THE OPERATED NORMALLY<[01] PER DISCREPANCY FOLLOW FIM 27-51 TASK 836; FOUND FLAP TRANSMISSIONSDR SWAA2023102601326Gusset · crackedFWD CARGO BAY AFT BULKHEAD SUPPORT GUSSET IS CRACKED BS500I S-19R WL193. MARKED<[01] UPDATED STEP 1;[02] UPDATED STEP 2;[03] UPDATED MEASUREMENT TABLE.;[04] UPDATED STEPS 4-5.;[05] UPDATED STEP 2.;[06] UPDATED STEP 3.;[07] UPDATED STEP 6;[08] EDITED MEASUREMENSDR SWAA2023102601321Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500G AFT SIDE RBL25 WL155.<[01] UPDATED STEP#1;2;3;[02] UPON FURTHER INVESTIGATION CRACKED INTERCOSTAL ATTACH ANGLE IS LOCATED AT FCB BS500G FWD SIDE RBL25 WL155;[03] REMOVED AND REPLACED INTERCOSTAL ATTACH ANGLE AT FCSDR SWAA2023102601328Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500I FWD SIDE RBL25 WL155. CRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500H FWD SIDE RBL25 WL155<[01] UPDATE STEP #1;2;3;[02] UPON FURTHER INVESTIGATION CRACKED INTERCOSTAL ATTACH ANGLE IS LOCATED AT FCB BS500H FWD SIDE SDR SWAA2023102601329Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500I AFT SIDE RBL25 WL155.<[01] UPON FURTHER INVESTIGATION CRACKED INTERCOSTAL ATTACH ANGLE WAS FOUND TO BE AT BS 500H AFT SIDE RBL 25 WL 155.;[02] REMOVED AND REPLACED INTERCOSTAL ATTACH ANGLE AT FCB BS500H AFT SIDE RSDR SWAA2023102601322Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500I FWD SIDE LBL25 WL155.<[01] RECEIVED NEW ATTACH ANGLE<BR>ITEM# : 143A7502U159<BR>PO# : 938941/1<BR><BR>REMOVED AND REPLACED NEW ATTACH ANGEL IAW SRM 51-40-02-0G-0 AND DWG 143A7505 ID:0109 REV:-;[02] VERIFIED STEPS SDR SWAA2023102601323Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500I AFT SIDE LBL25 WL155.<[01] REMOVED AND REPLACED NEW ATTACH ANGEL IAW SRM 51-40-02-0G-0 AND DWG 143A7505 ID:0109 REV:-;[02] VERIFIED STEPS 1;2;3; COMPLETE AND MEASUREMENT TABLE; CARD COMPLETE.SDR SWAA2023102601330Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500F FWD SIDE RBL25 WL155.<[01] UPON FURTHER INVESTIGATION INTERCOSTAL ATTACH ANGLE AT FCB BS500E FWD SIDE RBL25 WL155 FOUND NOT TO BE CRACKED. CLEANED AREA IAW SOPM 20-30-03;[02] VERIFIED MEASUREMENT TABLE<BR><BR>VERISDR SWAA2023102601324Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500E FWD SIDE RBL25 WL155.<[01] UPON FURTHER INVESTIGATION INTERCOSTAL ATTACH ANGLE AT FCB BS500E FWD SIDE RBL25 WL155 FOUND NOT TO BE CRACKED. CLEANED AREA IAW SOPM 20-30-03;[02] VERIFIED JOB COMPLETE;[03] RII STEP ENSDR SWAA2023102601325Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500G FWD SIDE LBL25 WL155.<[01] REMOVED AND REPLACED INTERCOSTAL ATTACH ANGLE AT FCB BS500G FWD SIDE LBL25 WL155 IAW BOEING DWG 143A7505 AND SRM 51-40-02;[02] VERIFIED CORRECTIVE ACTION 1.;[03] TASK COMPLETESDR SWAA2023102601327Support Angle · corrodedCORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT FCB BS500I LBL23 TO RBL23 WL156.<[01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS OF FCB ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE 500I LBL 23 RBL 23 WL 156 IAW SRM 53-30-08-1A-1;[02] SRM 53-30-08-1A-1 ISSDR SWAA2023102601317Sidewall Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT BS500B+11 - BS500E; BS500G - BS500H RBL23 WL156.<[01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS OF FCB FLOOR TO SIDEWALL SUPPORT BS 500B+11-BS 500E;BS 500G-500H RBL 23 WL 156 IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGSDR SWAA2023102601332Strap · corrodedCORROSION ON TENSION STRAP AT AFT WET AREA BS1016+12 LBL17 WL208.<[01] EDITED STATUS FROM PENDING TO PARTIAL;;[02] UPDATED MEASUREMENT TABLE;[03] REMOVED CORROSION FROM AFT WET AREA ON TENSION STRAP BS1016+12; LBL17; WL208; THE FINAL REPAIR PROCESS WILL BE ACCSDR SWAA2023102601333Intercostal · corrodedCORROSION AROUND FASTENERS ON FLOOR SUPPORT AT AFT WET AREA BS947+4 LBL24 WL208.<[01] UPDATED STEP 1;[02] REMOVED AND REPLACED INTERCOSTAL AT BS 947.5 TO 967; LBL 24; WL 208 PER SRM 51-40-02-0G-0 AND BOEING DWG 147A5650.;[03] VERIFIED CORRECTIVE ACTION 2.<BR>VSDR SWAA2023102601334Channel · corrodedCORROSION ON AED MOP SILL BS947+4 LBL54 WL208.<[01] UPDATED STEP 1;[02] UPDATED STEP 2. ADDED ORIGINAL MATERIAL THICKNESS.;[03] REMOVED CORROSION FROM AED MOP SILL BS947+4 LBL54 WL208 FOUND TO BE WITHIN LIMITS PER RM 53-70-15-1A-1; PAR. 4.D.(2). (A). FIG. 103;SDR SWAA2023102601335Channel · corrodedCORROSION ON ASD MOP SILL BS947 - BS991 RBL54 WL208.<[01] UPDATED STEP 1;[02] UPDATED STEP 2. ADDED ORIGINAL MATERIAL THICKNESS.;[03] REMOVED CORROSION FROM ASD MOP SILL BS947 - BS991 RBL54 WL208; FOUND TO BE WITHIN LIMITS PER SRM 53-70-15-1A-1; PAR. 4.D.(2). SDR SWAA2023102510436Flap · delaminatedR/H OUTBOARD AFT FLAP LOWER SKIN IS DELAMINATED AT THE I/B EDGE. (MARKED)<[01] VERIFIED STEP 2 IN PARTIAL.;[02] REMOVED AND REINSTALLED R/H O/B AFT FLAP IAW AMM27-51-22-400-801.;[03] REMOVED AND REPLACED R/W O/B AFT FLAP IAW AMM 27-51-22;[04] COMPLETED MEASURESDR SWAA2023102501320Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FCB BS500G FWD SIDE RBL25 WL155.<[01] REMOVED AND REPLACED INTERCOSTAL ATTACH ANGLE AT FCB BS500G FWD SIDE RBL25 WL155 IAW BOEING DWG143A7505 AND SRM 51-40-02;[02] WORK WAS ACCOMPLISHED ON CUSTOMER CARD #TTG8Q00NFNQX;[03] VESDR SWAA2023102501331Gusset · crackedFWD CARGO BAY AFT BULKHEAD SUPPORT GUSSET IS CRACKED BS500I S-21L WL177. MARKED<[01] UPDATED STEPS 1-2.;[02] UPDATED MEASUREMENT TABLE.;[03] UPDATED STEP 3.;[04] UPDATED STEP 4.;[05] UPDATED STEP 3.;[06] UPDATED STEP 3;[07] UPDATED STEP 2.;[08] UPDATED STEP 5.SDR SWAA2023101800668Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED LBL-13 BETWEEN STA-380-400 (MARKED)<[01] REMOVED UPPER ANGLE FROM WEB PER 51-40-02.;[02] REMOVED AND REPLACED DISCREPANT CHORD WITH NEW 143A5410-174 CHORD IAW SRM 51-40-02;[03] CWSDR SWAA2023101800948Scuff Plate · crackedFWD CARGO DOOR FWD SCUFF PLATE CRACKED<[01] REPLACED FWD SCUFF PLATE PER AMM 53-11-02 AND PERFORMED PRESSURIZATION LEAK CHECK PER AMM 05-51-91; CHECKS GOOD.;[02] C/W INSPECTION LEAK CHECK GOODSDR SWAA2023101800966Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS EVIDENCE OF CORROSION FROM STA.500E TO STA.500F<[01] BLENDED AREAS; FOUND GOUGE .020 DEEP; OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED SECTION OF TRANSITION ANGLE FROM STA. 500E + 10 TO 500F + 10. FABRICATED REPAIRED PASDR SWAA2023101800967Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS EVIDENCE OF CORROSION FROM STA.500F TO STA.500G<[01] BLENDED AND REMOVED .003' MATERIAL; WITHIN LIMITS PER SRM 53-00-53-1A-2. SECTION OF TRANSITION ANGLE FROM STA. 500E + 10 TO 500F + 10 TO BE REPLACED ON NR #TTG8Q00NFN2J.;[0SDR SWAA2023101800957Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS EVIDENCE OF CORROSION FROM STA.500D TO STA.500E (MARKED)<[01] REMOVED CORROSION ON TRANSITION ANGLE PER SRM 51-10-02-0G-0-B00070.FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-!A-2;[02] FABRICATED REPAIR SECTION AND SPLICE REPAIRSDR SWAA2023101800958Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS EVIDENCE OF CORROSION FROM STA.500E TO STA.500F (MARKED)<[01] REMOVED CORROSION ON TRANSITION ANGLE PER SRM 51-10-02-0G-0-B00070.FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-!A-2;[02] REMOVED CORROSION ON TRANSITION ANGLE PER SSDR SWAA2023101801184Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727D-727E AROUND FASTENER HOLES<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO STA 847. PN 146A7502-31 IAW SRM 51-40-02;[02] C/W INSP .REMOVED AND REPLACED L/SDR SWAA2023101801185Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727E-727F AROUND FASTENER HOLES.<[01] C/W INSP.SDR SWAA2023101801186Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727F-727G AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP REMOVED ANSDR SWAA2023101801183Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727G-727H AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP. REMOVED ASDR SWAA2023101801187Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727H-727I AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP. REMOVED ASDR SWAA2023101801188Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727I-727J AROUND FASTENER HOLES<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP. REMOVED ANSDR SWAA2023101801189Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727J-747 AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP. REMOVED ANSDR SWAA2023101801190Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 747-767 AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] CC/W INSP. REMOVED ANSDR SWAA2023101801191Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 767-787 AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP. REMOVED ANDSDR SWAA2023101801192Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 787-807 AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP. REMOVED ANDSDR SWAA2023101801203Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 807-827 AROUND FASTENER HOLES.<[01] REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA 727 TO 847 WORK PERFORMED ON LINE ITEM 2317 SEE TTG8Q00NFPVB;[02] C/W INSP .REMOVED ANDSDR SWAA2023101802745Web · corrodedAFT CARGO DOOR THRESHOLD WEB HAS AREAS OF LIGHT SURFACE CORROSION FROM BS 787+16 THROUGH BS 847-9.<[01] REMOVED CORROSION AFT CARGO DOOR THRESHOLD WEB FROM BS 787+16 THROUGH BS 847-9. ORIGINAL THICKNESS IS 0.050?; MATERIAL LOSS IS 0.010?; MAX ALLOWED IS 0.005?SDR SWAA2023101801193Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727A-727B AROUND FASTENER HOLES<[01] REMOVED AND REPLACED R/H TRANSITION ANGLE 146A7502-52 IAW SRM 51-40-02;[02] REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA 727 TO STSDR SWAA2023101801204Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727D-727E AROUND FASTENER HOLES.<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801194Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727E-727F AROUND FASTENER HOLES<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801195Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727F-727G AROUND FASTENER HOLES<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801196Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727G-727H AROUND FASTENER HOLES.<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801197Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727H-727I AROUND FASTENER HOLES<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801198Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727I-727J AROUND FASTENER HOLES.<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801199Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727J-747 AROUND FASTENER HOLES.<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801205Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 747-767 AROUND FASTENER HOLES.<[01] TRANSITION ANGLE IS OUT OF LIMITS SEE TTG8Q00NFPWP FOR R&R OF TRANSITION ANGLE.;[02] VERIFIED CORRECTIVE ACTION #1.<BR> INSPECTION C/W.SDR SWAA2023101801200Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 767-787 AROUND FASTENER HOLES.<[01] REMOVED CORROSION ON AFT CARGO FLOOR STRUCTURE R/H PLATE (SHIELD) AROUND FASTENER HOLE LOCATIONS FROM STA 767-787 . ORIGINAL THICKNESS ISSDR SWAA2023101801182Sidewall Support · crackedAFT CARGO COMPARTMENT; BS 867; LBL 10; AT FLOOR LEVEL; ANGLED BRACKET AT LOWER END OF SIDEWALL SUPPORT STANCHION IS CRACKED ON OUTBD SIDE. (MARKED)<[01] REMOVED DISCREPANT PART AND PARTIALLY REPLACED WITH NEW ANGLED BRACKET PART #149A8109U114 BN 311961;[02] RE
Back to Boeing 737-8H4