SDR SWAA2023052431322Floor Panel · pulledPASSENGER FLOOR PANEL 231MF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REMOVED AND REPLACED CABIN FLOOR PANEL 231MF PER A.M.M. 53-21-00SDR SWAA2023052431321Floor Panel · pulledPASSENGER FLOOR PANEL 231QF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REMOVED AND REPLACED CABIN FLOOR PANEL 231QF PER A.M.M. 53-21-00SDR SWAA2023052431320Floor Panel · pulledPASSENGER FLOOR PANEL 242QF HAS MULTIPLE DENTS/ PULLING FIBER<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052431331Floor Panel · pulledPASSENGER FLOOR PANEL 242PF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052431335Floor Panel · pulledPASSENGER FLOOR PANEL 241WF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052431336Floor Panel · pulledPASSENGER FLOOR PANEL 241UF HAS MULTIPLE DENTS/ PULLING FIBERS<[01] REPLACED WITH NEW FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR FLOOR PANEL REPLACEMENT.SDR SWAA2023052441434Support · crackedPASSENGER CABIN STA 540 LBL1 FLOORBOARD 'T' SUPPORT CRACKED.<[01] REMOVED AND REPLACED PANEL BREAK PER SRM 51-40-02.;[02] INSPECTED AS EREQUIRED. CORRECTIVE ACTION #1SDR SWAA2023052441435Support · crackedPASSENGER CABIN STA 540 RBL1 FLOORBOARD 'T' SUPPORT CRACKED.<[01] REMOVED FLOORBOARD 143A5810-535 TO FOM;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1. RAISED NEW FAULT FOR PASSENGER FLOOR PANEL 231UF REMOVE FOR FOM ACCOMPLISHED ON TTG8Q00KPT9L;[03] REMOVEDSDR SWAA2023050131180Light · inoperativeR2 DOOR SLIDE LIGHT INOP.<[01] RELAMPED R2 DOOR SLIGHT LIGHT & OPS CHECK GOOD REF AMM 33-51-04.SDR SWAA2023042831249Slide · out of adjustAFT SLIDES PREVENT DOORS FROM CLOSING WITHOUT HAVING TO LEAN DOWN AND PULL SLIDE UP<[01] REMOVED DEBRIS FROM BLOCKING AFT DOORS FROM CLOSING AND REATTACHED VELCRO WITH NO FURTHER DEFECTS NOTED. REF AMM 25-66-00.SDR SWAA2023052530833Flange · corrodedCORROSION ON FORWARD EDGE OF STA 947 FLOORBEAM UPPER FLANGE AT RBL 24.75; FORWARD OF R/H AFT LAV INBOARD; AFT TIEDOWN FITTING<[01] REMOVED TIE DOWN FITTING AT STA 947 RBL 24 TO F.O.M.;[02] REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. SDR SWAA2023052530667Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500G TO 500H RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530668Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500H TO 500I RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530658Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500H TO 500I LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I PER SRM 53-00-53-2R-5.REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK COMPLETED.;[02] INSPECTISDR SWAA2023052530654Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500G TO 500H LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I PER SRM 53-00-53-2R-5.REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK COMPLETED.;[02] INSPECTISDR SWAA2023052530660Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500D TO 500E LBL 24 WL 156.<[01] REMOVED CORROSION AT FASTENER HOLES PER SRM 51-10-02; FOUND TO BE OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2.;[02] INSPECTION C/W REMOVED CORROSION AT FASTESDR SWAA2023052530661Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500C TO 500D LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I PER SRM 53-00-53-2R-5.REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK COMPLETED.;[02] INSPECTISDR SWAA2023052530659Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500E TO 500F LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I PER SRM 53-00-53-2R-5.REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK COMPLETED.;[02] INSPECTISDR SWAA2023052530656Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500B TO 500C LBL 24 WL 156.<[01] REMOVED CORROSION ON L/H TRANSITION ANGLE PER SRM 51-10-02.REMOVED .001 OF MATERIAL THICKNESS; WITHIN ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMESDR SWAA2023052530662Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500 TO 500A LBL 24 WL 156.<[01] REMOVED CORROSION ON L/H TRANSITION ANGLE PER SRM 51-10-02.REMOVED .002 OF MATERIAL THICKNESS; WITHIN ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMEDSDR SWAA2023052530836Floorbeam · corrodedCORROSION ON FORWARD EDGE OF STA 947 FLOORBEAM UPPER FLANGE AT LBL 24.75; FORWARD OF AFT LAV INBOARD; AFT TIEDOWN FITTING<[01] REMOVED L/H LAV INBOARD AFT TIEDOWN FITTING TO FOM;[02] REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. FAILEDSDR SWAA2023052530666Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500F TO 500G RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530670Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500E TO 500F RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530669Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500C TO 500D RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530665Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500D TO 500E RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530664Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500B TO 500C RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530663Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500A TO 500B RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FSDR SWAA2023052530653Angle · corrodedFWD CARGO R/H TRANSITION ANGLE HAS SURFACE CORROSION STA. 500H TO 500I RBL 24 WL 156.<[01] COMPLETE PART REPLACEMENT ON NR# TTG8Q00KQJLZ LINE #2446.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1. FWD CARGO R/H TRANSITION ANGLE TO BE REPLACED ON FAULT TTG8QSDR SWAA2023052530655Angle · corrodedFWD CARGO L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES STA. 500F TO 500G LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I PER SRM 53-00-53-2R-5.REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK COMPLETED.;[02] INSPECTISDR SWAA2023052531027Seal · crackedFUSELAGE FWD UPPER COOKIE SHEET (SLIDING METAL SEAL THAT'S ATTACHED TO RT STAB) CRACKED.<[01] REMOVED AND REPLACED UPPER SLIDER SEAL PER AMM 53-31-31SDR SWAA2023052430835Intercostal · corrodedAFT GALLEY AREA FLOOR SUPPORT INTERCOSTAL BETWEEN FLOORBEAM STA 947 AND 967 LBL 24.75 HAS CORROSION AT FWD END<[01] REMOVED INTERCOSTAL FOR REPLACEMENT PER SRM 51-40-02;[02] INSTALLED NEW INTERCOSTAL PER SRM 51-40-02.;[03] ADD TOOL;[04] INSPECTEDSDR SWAA2023052442225Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500H TO 500I LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I PER SRM 53-00-53-2R-5.REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK COMPLETED.;[02] INSPECTION C/W L/H SDR SWAA2023052442511Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500G TO 500H LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I.<BR>REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK TO BE ACCOMPLISHED.;[02] INSPECTION C/W L/H TRANSITIOSDR SWAA2023052442512Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500F TO 500G LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I.<BR>REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK TO BE ACCOMPLISHED.;[02] INSPECTION C/W L/H TRANSITIOSDR SWAA2023052442513Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500E TO 500F LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I.<BR>REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK TO BE ACCOMPLISHED.;[02] INSPECTION C/W L/H TRANSITIOSDR SWAA2023052442514Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500D TO 500E LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I.<BR>REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK TO BE ACCOMPLISHED.;[02] INSPECTION C/W L/H TRANSITIOSDR SWAA2023052441480Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 420 TO 440 LBL 24 WL 156.<[01] BLENDED SCRIBE MARK PER 51-10-02.REMOVED .002 OF MATERIAL THICKNESS; WITHIN ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMED PER SRM 51-20-01.;[02] VERIFIED DAMAGSDR SWAA2023052443072Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500B TO 500C LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I.<BR>REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK TO BE ACCOMPLISHED.;[02] INSPECTION C/W L/H TRANSITIOSDR SWAA2023052443071Angle · scratchedFWD CARGO L/H TRANSITION ANGLE HAS SCRIB MARKS FROM STA. 500C TO 500D LBL 24 WL 156.<[01] L/H TRANSITION ANGLE WILL BE REPLACED FROM STA 500B+12 TO 500I.<BR>REFERENCE NON ROUTINE CARD #TTG8Q00KM7HK FOR WORK TO BE ACCOMPLISHED.;[02] INSPECTION C/W L/H TRANSITIOSDR SWAA2023052430622Angle · corrodedFWD CARGO COMPARTMENT LH TRANSITION ANGLE STA.500B +10INCH CORROSION AT FASTENER HOLE.<[01] SECTION OF TRANSITION ANGLE TO BE REPLACED FROM STA. 500B + 10 TO 500E + 10 ON TASK # TTG8Q00KM6SY.;[02] SECTION OF TRANSITION ANGLE TO BE REPLACED FROM STA. 500B + 10 SDR SWAA2023052430623Angle · corrodedFWD CARGO COMPARTMENT LH TRANSITION ANGLE STA.500C TO 500D CORROSION AT NUMEROUS FASTENER HOLES.<[01] SECTION OF TRANSITION ANGLE TO BE REPLACED FROM STA. 500B + 10 TO 500E + 10 ON TASK # TTG8Q00KM6SY.;[02] C/ C/A #1SDR SWAA2023052430624Angle · corrodedFWD CARGO COMPARTMENT LH TRANSITION ANGLE STA.500D TO 500E CORROSION AT NUMEROUS FASTENER HOLES.<[01] SECTION OF TRANSITION ANGLE TO BE REPLACED FROM STA. 500B + 10 TO 500E + 10 ON TASK # TTG8Q00KM6SY.;[02] C/ C/A #1SDR SWAA2023052430625Angle · corrodedFWD CARGO COMPARTMENT LH TRANSITION ANGLE STA.500E TO 500F CORROSION AT NUMEROUS FASTENER HOLES.<[01] CUT AND REMOVED DAMAGED SECTION OF TRANSITION ANGLE FROM STA. 500B +10 TO 500E +10. FABRICATED REPAIR PARTS PER SRM 53-00-53-2R-5.;[02] REPAIRED TRANSITION ANSDR SWAA2023052430628Angle · corrodedFWD CARGO COMPARTMENT RH TRANSITION ANGLE STA.500A TO 500B CORROSION AT NUMEROUS FASTENER HOLES.<[01] REMOVED CORROSION PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.STEP 2.;[02] VERIFIED CORROSION OUT OF LIMITS. SIGN OFF FOR CORRECTIVE ACTSDR SWAA2023052430973Seal · crackedPANEL 343AT STAINLESS BLADE SEAL CRACKED<[01] REMOVED AND REPLACED PANEL 343AT STAINLESS BLADE SEAL PER SRM 51-40-02.SDR SWAA2023052430657Angle · corrodedFWD CARGO AFT BULKHEAD SUPPORT ANGLE HAS HEAVY SURFACE CORROSION AT STA. 500I LBL 24 TO RBL 24 WL 156.<[01] REMOVED AND REPLACED FWD CARGO AFT BULKHEAD SUPPORT ANGLE STA 500 LBL 24 TO RBL 24 WL 156 PER SRM 51-40-02.SDR SWAA2023051530765Panel · crackedCRACKED BREAK PANEL STA 540; BL0- LBL 25; WL 208.<[01] UPDATED MEASUREMENTS. ON BS 540; BL0-LBL25; WL208; BREAK PANEL WILL BE A PART REPLACEMENT IAW SRM 51-10-02 STEP 9. REMOVED BREAK PANEL; AND RECEIVED A NEW BREAK PANEL; LOCATED HOLES; DRILLED; AND DEBURRED SDR SWAA2023051530761Support Angle · brokenBROKEN WIRE SUPPORT ANGLE BS867 AT STR. 3R.<[01] REMOVED AND REPLACED WIRE SUPPORT ANGLE BS867 AT STR 3R PER SRM 51-40-02-0G-0 REF DWG 146A7901;[02] VERIFIED CORRETIVE ACTION 1.;[03] WORKSCOPE IS COMPLETESDR SWAA2023050930636Support · corrodedAFT CARGO TEE SUPPORT P/N 146A9410-16 HAS CORROSION AROUND 1 FASTENER HOLE AFT CARGO TEE SUPPORT ASSY P/N 146A9401-4 HAS CORROSION AROUND 1 FASTENER HOLE<[01] ACCOMPLISHED PART TRANSACTION;[02] REMOVED CORROSION TO AFT CARGO TEE SUPPORT ASSY PER SRM 51-10-02-0SDR SWAA2023042731214Flashlight · failedAFT F/A FLASHLIGHT NOT WORKING<[01] REPLACED BATTERY PER AMM 25-64-00
Back to Boeing 737-8H4