What was found
FWD CARGO COMPARTMENT RH TRANSITION ANGLE STA.500A TO 500B CORROSION AT NUMEROUS FASTENER HOLES.<[01] REMOVED CORROSION PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.STEP 2.;[02] VERIFIED CORROSION OUT OF LIMITS. SIGN OFF FOR CORRECTIVE ACTION 1.;[03] REMOVED FASTENERS;CUT OUT DAMAGE SECTION ON RH TRANSITION ANGLE FROM STA 500A TO STA 500A+10 FOR REPAIR PER SRM 53-00-53-2R-5.;[04] LOCATED AND DRILLED RH TRANSITION ANGLE REPLACEMENT SECTION FROM STA 500A TO STA 500A+10 ; AND SIDE PLATE REPAIR SPLICE PER SRM 53-00-53-2R-5.TREATED AND PRIMED REPAIR PARTS PER SRM 51-20-01.;[05] INSTALLED THE RH TRANSITION ANGLE REPLACEMENT SECTION FROM STA 500A TO STA 55A+10 AND THE REPAIR SPLICE PER SRM 53-00-53-2R-5.;[06] INSTALLED 3 BONDING NUT PLATED PER SRM 51-40-10.ON MAY3;2023 @ 19:45;[10] REMOVED DAMAGED SECTION OF RH TRANSITION ANGLE ;AND INSTALLED THE RH TRANSITION ANGLE SECTION REPLACEMENT FROM STA 500A TO STA 55A+10 AND THE REPAIR SPLICE PER SRM 53-00-53-2R-5.INSTALLED 3 EACH BONDED NUT PLATES ;AND PERFORMED PUSH TEST GOOD PER SRM 51-40-10.;[11] INSPECTED CA #10