SDR SWAA2022081140916Flashlight · inoperativeAFT FLASHLIGHT INOP. / [01] R AND R FLASHLIGHT BATTERY FOR AFT RT LITE PER AMM 25-64-00.SDR SWAA2022081140946Light · out of positionCEILING EMERGENCY EXIT SIGN COVER CAME OFF / [01] RESECURED CEILING EMERGENCY EXIT SIGN COVER PER SIP.SDR SWAA2022081740841Flap · delaminatedLH OUTBOARD AFT FLAP HAS LARGE DELAMINATION ON THE INBOARD END. / [01] OK TO INSTALL L/H O/B AFT FLAP;[02] REMOVED AND INSTALLED NEW FLAP PER AMM 27-51-26;[03] COMPLIED WITH ADJUSTMENT CHECK AMM 27-51-22;[04] VERIFIED ADJUSTMENT CHECK AMM 27-51-22SDR SWAA2022081140641Light · inoperativeEXIT LIGHTS ASSOCIATED WITH BATTERY PACK M2816 ARE INOP. / [01] REMOVED NON-OPERATIONAL BATTERY PACK; INSTALLED AND PERFORMED GOOD INSTALLATION TEST OF NEW BATTERY PACK PER AMM 33-51-06-960-805.;[02] VERIFIED WORK ACCOMPLISHED AS NOTED IN ACTION ITEM 1.;[03] VSDR SWAA2022081140389Flashlight · inoperativeDURING MAIN CABIN CHECK IT WAS FOUND THAT FLIGHT ATTENDANTS FLASH LIGHT OUTBOARD SEAT (NEXT TO L1 DOOR) IS NOT TESTING / [01] REMOVED AND REPLACED FLIGHT ATTENDANTS FLASH LIGHT OUTBOARD SEAT (NEXT TO L1 DOOR) AS PER AMM 25-64-00. OPS CHECK NORMAL AND NO DEFECTSDR SWAA2022081140433Flashlight · inoperative3 AFT CABIN EMERGENCY FLASHLIGHTS WILL NOT TEST PROPERLY / [01] RESECURED 3AFT EMERGENCY. FLASHLIGHTS AS PER AMM 25-64-00SDR SWAA2022081140874Light · inoperativeEXIT SIGN MISSING F/A REPORTS EMERGENCY EXIT SIGN BY OVER WING EXITS CENTER AISLE MISSING FORWARD FACING LENS / [01] INSTALLED NEW EMERGENCY EXIT LENS IAW SIPSDR SWAA2022083040348Post · corrodedLAVATORY D. UPON INSPECTION FOUND VISUAL EVIDENCE OF CORROSION ON BOTTOM OF AFT DOOR POST . / [01] REMOVED HEADER AND AFT DOOR POST FROM LAVATORY D TO BE REPAIRED PER CMM25-48-25;[02] REMOVED 6'FROM THE BOTTOM OF LAV D DOOR POST AS INSTRUCTED IN YOKOHAMA CMM 2SDR SWAA2022082440115Baffle · crackedCRACKED INTERCOSTALL BAFFLE P/N# 143A7510-22 AT STA 500D - 500E RBL 25. / [01] VERIFIED APPLICABILITY; AREA FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 PARA. 4-C FIG. 103;[02] REMOVED BAFFLE IAW SRM 51-40-02-0G-0;[03] LOCATED AND DRILLED NEW BAFFLE P/N 143A7510-SDR SWAA2022082440116Baffle · crackedCRACKED INTERCOSTALL BAFFLE P/N# 143A7510-24 AT STA 500C - 500D RBL 25. / [01] VERIFIED APPLICABILITY; AREA FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2; PARA. 4-C FIG. 103;[02] REMOVED BAFFLE IAW SRM 51-40-02-0G-0;[03] LOCATED AND DRILLED NEW BAFFLE P/N 143A7510SDR SWAA2022081240190Floor Panel · crackedBREAK PANEL IS CRACKED AT STA 540; BL 0-LBL 25; WL 208. / [01] UPDATED TABLE;[02] REMOVED FLOOR PANEL 231UF PER AMM 53-21-00-000-801;[03] REMOVED BRAKE PANEL AT STA 540 BL0 - LBL 25 WL 208 PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW BREAK PANEL AT STA 5SDR SWAA2022081040106Panel · damaged#2 ENGINE FAN DUCT PANELS #2 AND #3 HAVE HARDWARE HOLES ELONGATED / [01] REMOVED AND REPLACED #2 ENGINE FAN DUCT PANELS #2 AND #3 POSITIONS PER AMM 72-23-07SDR SWAA2022081040177Radome · delaminatedRADOME ASSY HAS DELAMINATION. / [01] REMOVED AND REPLACED RADOME PER AMM 53-52-00.;[02] VERIFIED DALE BOMGARDNER (TECHNICIAN); 10-AUG-2022 07:23 UTC<BR>REMOVED AND REPLACED RADOME PER AMM 53-52-00.SDR SWAA2022080940032Light · loosePASSENGER CABIN R/H OVER WING EXIT DOOR EMERGENCY EXIT LIGHT WIRES LOOSE AT BOTH UPPER CORNERS. / [01] RESECURE WIRES ON PASSENGER CABIN R/H OVER WING EXIT DOOR; EXIT LIGHT WIRES AT BOTH UPPER CORNERS PER SIPSDR SWAA2022090249508Floor Panel · brokenPANEL 221BF AFT O/B EDGE IS BROKEN. (228-003) / [01] RECEIVED NEW FLOOR PANEL ; PANEL WILL BE INSTALLED ON WORK CARD TTG8Q00DAN6K;[02] VERIFIED STEP 1SDR SWAA2022090249509Floor Panel · brokenPANEL 222DF I/B SIDE AT 23 ' TO THE FWD SIDE IS BROKEN. / [01] RECEIVED NEW FLOOR PANEL ; PANEL WILL BE INSTALLED ON WORK CARD TTG8Q00DAN5K;[02] VERIFIED STEP 1SDR SWAA2022083039526Intercostal · crackedFOUND CRACK ALONG THE HOLE AT FWD AREA INTERCOSTAL AT STA 312 + 8' LBL 45.6 WL 208.1 (228- 002) / [01] REMOVED INTERCOSTAL AT STA 312 + 8' LBL 45.6 IRW SRM 51-40-02;[02] LOCATED AND DRILLED NEW INTERCOSTAL AT STA 312 + 8' LBL 45.6 IRW SRM 51-40-05;[03] VERIFIESDR SWAA2022083039524Intercostal · crackedFOUND CRACK ALONG THE HOLE AT FWD AREA INTERCOSTAL AT STA 277 + 13' ;LBL 00 ;WL 208.1 (228- 004) / [01] REMOVED FWD AREA INTERCOSTAL AT STA 277+13 LBL 00 WL 208.1 IAW B737-800 SRM 53-10-51-0I-2;[02] LOCATED AND DRILLED NEW INTERCOSTAL AT STA 277+13 LBL 00 IRW SDR SWAA2022081539653Battery Pack · inoperativeEMERGENCY LIGHTS AROUND FWD ENTRY DOOR INOP / [01] REMOVED REPLACED AND OPS CHECKED EMERGENCY LIGHT BATTERY PACK AT FWD ENTRY DOOR PER AMM 33-51-06;[02] VERIFIEDSDR SWAA2022080939996Strip · looseCAPT SIDE ROW 13 PHOTOLUMINESCENT STRIP LOOSE / [01] RESECURED STRIP IAW AMM 33-51-15SDR SWAA2022083139523Intercostal · corrodedCORROSION. AT AFT CABIN WET AREA FLOOR SUPPORT FASTENER HOLE LBL. 50 BETWEEN STA 947.5 AND STA 967 WL208.1 / [01] LOCATED AND DRILLED AT AFT CABIN WET AREA FLOOR SUPPORT LBL 50 BETWEEN STA 947.5 AND STA 967 WL 208.1 AS PER SRM 51-40-05-0G-0;[02] LATE ENTRY REMSDR SWAA2022080939457Light · inoperativeEMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1672 ARE INOP<[01] REMOVED AND REPLACED M1672 BATTERY PACK PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION #1;[03] PERFORMED GOOD TEST OF NEW BATTER PACK PER AMM 33-51-06-960-805 STEPS 4.E.6.A-C.;[0SDR SWAA2022080939456Light · inoperativeEMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1675 ATE INOP<[01] REMOVED AND REPLACED M675 BATTERY PACK PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION #1;[03] PERFORMED GOOD TEST OF NEW BATTERY PACK PER AMM 33-51-06-960-805 STEPS 4.E.6.A-C.;[0SDR SWAA2022080939458Light · inoperativeEMERGENCY EXIT LIGHTS ASSOCIATED WITH BATYERY PACK M1676 ARE INOP<[01] REMOVED AND REPLACED M1676 BATTERY PACK PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION #1;[03] PERFORMED GOOD TEST OF NEW BATTER PACK PER AMM 33-51-06-960-805 STEPS 4.E.6.A-C.;[0SDR SWAA2022080839437Battery · inoperativeFA REPORTS FWD GALLEY INBOARD EMERGENCY FLASHLIGHT NOT TESTING. REPLACED BATTERY IN FLASHLIGHT; CHECKS GOOD. REF AMM 25-64-00. FLASHLIGHT WILL NOT TEST IN FLASHLIGHT HOLDER. OK TO CONTINUE ON MEL 25-64-02 AUTH# 80532. REMOVED AND RESEATED FWD INB FLASHLIGHTSDR SWAA2022080839366Power Supply · inoperativeFWD ENTRY DOOR EMERGENCY LIGHT NOT ILLUMINATING / [01] REMOVED AND REPLACED L/H FWD ENTRY EMERGENCY POWER SUPPLY UNIT . TEST OK. REF AMM. 33-51-06. -END-SDR SWAA2022082539251Stringer · crackedL/H FIXED LEADING EDGE STRINGER 15 INCHES FWD OF WING LEADING EDGE SPAR NEXT TO SEAL RIB IN ZONE 1A JUST INBOARD OF PYLON THE SECOND STRINGER IS CRACKED AT OUTBOARD END. / [01] REMOVED THE EXISTING CRACKED STRINGER PER SRM 51-40-02 AND DRILLED THE NEW STRINGERSDR SWAA2022080839245Flashlight Assy · brokenFLASHLIGHT BRACKET BROKEN AT AFT R/H ATTENDANCE SEAT OUTBOARD POSITION / [01] REPLACED FLASHLIGHT ASSY PER AMM 25-64-00-200-802 STEPS (4); (6); (7);[02] REPLACED FLASHLIGHT BRACKET ASSY PER AMM 25-64-00-200-802 SEC 10 B STEPS (3); (4); (6); (7) & AMM SWAD633A1SDR SWAA2022080839407A/C Pack · overheatedOVERHEAT ODOR POSSIBLY FROM PACKS AT HIGH POWER SETTING AT HIGH ALTITUDE (FL350) NOT ASSOCIATED WITH ANY ANNUNCIATOR LTS OR ANY ABNORNAL INDICATION.FAINT ORDOR ALSO BRIEFLY AT EARLY CLIMB OUT AND BRIE / [01] PERFORMED FIM TASK 21-00 TASK 806. R AND R LH AND RHSDR SWAA2022080839622Acm · overheatedOVERHEAT ODOR POSSIBLY FROM PACKS AT HIGH POWER SETTING AT HIGH ALTITUDE (FL350) NOT ASSOCIATED WITH ANY ANNUNCIATOR LTS OR ANY ABNORNAL INDICATION.FAINT ORDOR ALSO BRIEFLY AT EARLY CLIMB OUT AND BRIE / [01] PERFORMED FIM TASK 21-00 TASK 806. R AND R LH AND RHSDR SWAA2022080838762Nozzle · cracked#2 ENGINE PRIMARY EXHAUST NOZZLE PERFORATED FACE SHEET HAS A CRACK IN ZONE 2 AT THE 6:00 POSITION MEASURING 1 INCH IN LENGTH; 13 INCHES FWD OF THE AFT WELD LINE. / [01] REMOVED AND REPLACED #2 ENGINE PRIMARY EXHAUST NOZZLE IAW AMM 78-11-01.SDR SWAA2022080538772Light · inoperativeAFT ENTRY DOOR EMERGENCY LT INOP / [01] RELAMPED AFT ENTRY EMERGENCY SLIDE LT PER AMM 33-51-04. OPS CHK OK.SDR SWAA2022091538528Stringer Clip · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS727E S-10L. MARKED. / [01] NO FOUND ALLOWABLE DAMAGE LIMITS ON SRM ; MUST BE REPLACED IAW SRM 51-10-02 PARAGRAPH 9;[02] REMOVED STRINGER CLIP AT PASSENGER CABIN BS727E S-10L. IAW SRM 51-40-02;[03] LOCATED AND DRILLED SDR SWAA2022091538529Stringer Clip · crackedCRACKED STRINGER CLIP AT PASSENGER CABIN BS727H S-10L. MARKED. / [01] NO FOUND ALLOWABLE DAMAGE LIMITS ON SRM ; MUST BE REPLACED IAW SRM 51-10-02 PARAGRAPH 9;[02] REMOVED STRINGER CLIP AT PASSENGER CABIN BS727H S-10L. IAW SRM 51-40-02;[03] LOCATED AND DRILLED SDR SWAA2022082538757Channel · corrodedCORROSION ON FWD CARGO BAY RAIL AT RBL 9 BS 480+2. / [01] SRM 53-00-53-1A-2 IS FOUND TO BE APPLICABLE;[13] FABRICATED; LOCATED; DRILLED; DEBURRED; APPLIED CHEM. CONV. COATING AND PRIMER TO REPAIR PARTS; REWORKED AREA PER SRM 53-00-53-2R-2 ALTERNATIVE 3. STEP 4SDR SWAA2022082538755Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500H+2; BS 500H+7; BS 500H+11; BS 500H+15. / [01] SRM 53-00-53-1A-2 FOUND TO BE APPLICABLE. REMOVED CORRSION FROM FCB R/H FLOOR TO SIDEWALL SUPPORT AT RBL 24;<BR><BR>BS 500H+2 L=1' W=0.8' D=0.00SDR SWAA2022082538743Attach Angle · corrodedCORROSION ON FSD THRESHOLD ATTACH ANGLE BS308-318 RBL 58 WL208 / [01] REMOVED COROSION ON FSD THRESHOLD ATTACH ANGEL AT BS 308 RBL 58 WL 208; 1''X1''X.015'' FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-2.;[02] CERTIFY;[03] VERIFIED OUT OF LIMITS.;[04] REMOVEDSDR SWAA2022082538748Web · corrodedCORROSION ON FWD CARGO BAY THRESHOLD AT RBL 28 BS 440+8; BS 440+14; BS 460+2; BS 460+4; BS 460+9; BS 460+11; BS 460+18; BS 480+2; BS 480+4. / [01] REMOVED CORROSION FROM FCD THRESHOLD WEB AT BS 440+8 MEASURED 1.8'W X 1.8'L AND 0.004' DEEP; ORIGINAL THICKNESS OSDR SWAA2022082538749Shield · corrodedCORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 23 BS 500+18. / [01] UPDATED MEASUREMENTS;[02] FIXED MEASUREMENTS 7-12;[03] REMOVED DAMAGE IN A 0.5'X0.5'DEPTH 0.005. AT BS500+18 RBL23. SHIELD IS OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE LIMIT. REPAIR BY REPLASDR SWAA2022082538754Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500D+15; BS 500D+20; BS 500E+2; BS 500E+7; BS 500E+11; BS 500E+20; BS 500F+2; BS 500F+7; BS 500F+2; BS 500F+7. / [01] REMOVED CORROSION FROM FCB R/H FLOOR TO SIDEWALL SUPPORT AT BS 500D+20 RBL 2SDR SWAA2022081538725Intercostal · corrodedINTERCOSTAL BELOW RT ZEE CHANNEL FROM STA 747 TO STA 767 HAS AREAS OF CORROSION. INTERCOSTAL BELOW RT EE CHANNEL FROM STA 747 TO STA 767 HAS AREAS OF CORROSION. / [01] REMOVED AND REPLACED AFT CARGO RT INTERCOSTAL FROM STA 747 TO STA 767 IAW SRM 51-40-02.SDR SWAA2022081138546Floor Panel · distortedFORWARD CARGO PANEL 120CF; FASTENER HOLES DISTORTED. FORWARD CARGO FLOOR PANEL 120CF HAS SEVERAL DISTORTED FASTENER HOLES. / [01] OBTAINED REPLACEMENT PANEL FROM STOCK. PANEL TO BE INSTALLED ON ROUTINE CARD TTG8Q00DA024.;[02] VERIFIED.SDR SWAA2022091538093Stringer Clip · crackedREJECT STRINGER 10R CLIP AT B S 927 IS CRACKED / [01] UPDATED MEASUREMENT TABLE;[02] SRM DOES NOT HAVE REPAIR LIMITS FOR CRACKED STR CLIPS. OUT OF LIMITS AND TO BE REPLACED IAW SRM 51010-02-0G-0 STEP 9.;[03] REFERENCE IS SRM 51-10-02-0G-0 STEP 9;[04] CERTIFY;[SDR SWAA2022082437843Floor Panel · pulledCABIN FLOOR PANEL 232CF UPPER SKIN HAS PULLED STRANDS AT THE AFT O/B CORNER. (MARKED) / [01] IDENTIFIED PANEL 232CF IAW SRM 53-00-50-0I-1 TABLE 3 FIG 3.<BR><BR>DAMAGE NOTED IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4B<BR><BR>TO BE REPAIRED ISDR SWAA2022082437844Floor Panel · pulledFLOOR PANEL 232DF UPPER SKIN HAS PULLED STRANDS ALONG THE AFT EDGE. (MARKED) / [01] IDENTIFIED PANEL 232DF IAW SRM 53-00-50-0I-1 TABLE 3 FIG 3.<BR><BR>DAMAGE NOTED IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4B OK TO POT EXPOSED CORE IAW SRM 5SDR SWAA2022082438246Transition Panel · corrodedLIGHT CORROSION ON R/H TRANSITION ANGLE AROUND NUT PLATE HOLES; STA 492 TO 500A; RBL 24. / [01] CHANGED FAULT NAME FROM - LIGHT CORROSION ON R/H TRANSITION ANGLE AROUND NUT PLATE HOLES; STA 500 TO 500B; RBL 24. TO - LIGHT CORROSION ON R/H TRANSITION ANGLE AROUSDR SWAA2022080438083Sliding Sleeve · crackedR/H UPPER FORWARD SLIDING SEAL TRACK DAMAGED NOTED DURING SEAL R/R; REF TTG8Q00DXYUM RIGHT HORIZONTAL STABILIZER UPPER FWD SLIDING SEAL CRACKED. TRACK NO STOCK NEVER STOCK. FWD TRACK DAMAGED / [01] OK TO CONTINUE PER CDL 55-10-01 AUTHORIZATION 79955SDR SWAA2022080337678Seal · crackedLEFT HORIZONTAL STABILIZER UPPER FWD SLIDING SEAL CRACKED.<[01] REPLACED LT HORZ STAB UPPER SLIDING FWD SLIDING SEAL REF 53-31-31.SDR SWAA2022080337679Seal · crackedRIGHT HORIZONTAL STABILIZER UPPER FWD SLIDING SEAL CRACKED. TRANSFERRED TO TTG8Q00DZPBA FURTHER DAMAGE NOTED TO FWD TRACK.SDR SWAA2022082537833Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727F+6; BS 727F+16; BS 727G+8; BS 727G+10; BS 727G+19; BS 727H; BS 727H+6. / [01] REMOVED CORROSION FROM ACB L/H FLOOR TO SIDEWALL SUPPORT AT BS 727H LBL 21 MEASURED 2'W X 1'L AND 100% MATERIAL
Back to Boeing 737-8H4