Boeing 737-8H4
Service difficulty reports · 24,363
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020112431915Slide · out of toleranceFWD ENTRY DOOR (L1) SLIDE GAUGE IS IN RED. REMOVED AND REPLACED FWD ENTRY DOOR SLIDE ASSEMBLY, IAW SWA WORK INSTRUCTION NO 725-61-06 A TAG YF0100 POS: L1 TAG/GRB NO: 139798 P/N OFF: 5A3307-7 S/N OFF: BNG8456 P/N ON: 5A3307-7 S/N ON: BNG18047.SDR SWAA2020112331594Slide · out of positionL-2 DOOR SLIDE LINT BAR, LINT TOO LONG NEEDS REINSTALLED. REMOVED & REPOSITIONED L-2 DOOR SLIDE, PER WI 725-61-06AMT 117477INSP 43511 P44.SDR SWAA2021081331428Strake · damagedDAMAGE NOTED ON RIGHT WINGTIP LOWER STRAKE/WINGLET (BOTH REMOVED) ( SPLIT SCIMITAR WINGLET VENTRAL STRAKE ) / INSTALLED LT/RT VENTRAL STRAKES I/A/W AVIATION PARTNERS BOEING CMM TASK 57-31-00 CL# 82668SDR SWAA2020112331333Holder · looseFWD SERVICE DOOR GIRTH BAR HOLDER IS LOOSE. PERFORMED W/O 722120 EA 20-125-02324-TLD AND MT 725-61-06. PERMANENT REPAIR REQUIRED IN 10 DAYS. PERMANENT REPAIR REQUIRED. RESOLVED ON W/O: 721057 TASKCARD: N/R-00001.SDR SWAA2020112330856Battery Pack · inoperativeEMERGENCY LIGHTS AT ROW 15C, 19C, 23C, AND AFT LEFT OVERWING EXIT WILL NOT ILLUMINATE. REPLACED BATTERY PACK AT CHARGER (M1670) ROW 21, IAW AMM 33-51-06 LIGHTS OPERATE NORMALSDR SWAA2020112330861Skin · cracked7' CRACK FROM FASTENER TO FASTENER AT RBL 54.0, JUST ABOVE HYDRAULIC SERVICE PUMP IN GFRP WEB MATERIAL. PERFORMED INTERIM REPAIR, IAW SRM 57-10-10-1A-2 2C (3)(A). SPEED TAPE TO BE REINSPECTED FOR CONDITION EVERY 600 FLT CYCLES, REF EA OTHER 57 EA 03738, REF SDR SWAA2020111830912Flashlight · inoperativeFWD CABIN FLASHLIGHT INOPERABLE. CABIN EMERGENCY FLASHLIGHT HOLDERS/FLASHLIGHTS. INSTALLED NEW FLASHLIGHT, PER AMM 25-64-00CL NR 82281.SDR SWAA2021062930712Angle · corrodedAFT CARGO RH TRANS ANGLE LOWER SURFACE NUT PLATE HAS CORROSION STA 767+5' / REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA 767-794 PER SRM 51-40-02 ( PN# 146A8127-12)SDR SWAA2020120830699Angle · corrodedCORROSION ON ANGLE AT FLOOR STA 986.5 + 6 RBL 32. REMOVED AND REPLACED FLOOR SUPPORT ANGLE WITH NEW ANGLE AT STATION 986.5 + 6 RBL 32, IAW SRM 51-40-02.SDR SWAA2020111830925Lens · looseFLOOR EXIT SIGN COVER ROW 14 FED EXIT SEATS. REINSTALLED EXIT LIGHT LENS AT ROW 14DEF, IAW AMM 33-51-01.SDR SWAA2020111730857Cradle · inoperativeAFT EMERGENCY FLASHLIGHT INOPERABLE. CABIN EMERGENCY FLASHLIGHT HOLDERS/FLASHLIGHTS.SDR SWAA2021080530627Strip · damagedTHE CAPSTRIP AT STA 727 FLOOR BEAM AREA DAMAGED. / REPLACED PART PER SRM 51-10-02SDR SWAA2021072030607Attach Angle · corrodedFWD CARGO AFT BULKHEAD WALL LOWER RAIL HAS HEAVY CORROSION FROM LBL 24- RBL 24 STA. 500I. MRKD / REMOVED AND REPLACED AFT BULKHEAD LOWER ATTACH ANGLE PER SRM 51-40-02.SEE SA-M 326SDR SWAA2021062930549Baffle · crackedINTERCOSTAL / BAFFLE CRACKED AT STATION 500E TO 500F UNDER RIGHT HAND TRANSITION ANGLE / REMOVED AND REPLACED INTERCOSTAL/BAFFLE FROM STA. 500E TO STA. 500F UNDER R/H TRANSITION ANGLE @ RBL 22' PER SRM 51-40-02SDR SWAA2021040730601Floor Panel · damagedAFT CARGO PIT FLOOR BOARD 140 BF HAS NUMEROUS AREAS OF DAMAGE. / FABRICATED AFT CARGO FLOOR PANEL 140BF IAW DWG 453A2610; PANEL TO BE INSTALL ON SAM 5655SDR SWAA2020111730551Flashlight · inoperativeCREW REPORTS FWD F/A FLASHLIGHT WILL NOT TEST. RESET AND RESEALED FWD F/A FLASHLIGHT, PER AMM 25-64-00.SDR SWAA2020111730550Light · inoperativeEMERGENCY PATH LIGHT STRIP ON AIRCRAFT RIGHT ROW 10 DEF AND 2 DEF WILL NOT RECHARGE OR ILLUMINATE. REMOVED AND REPLACED EMERGENCY PATH FLUORESCENT STRIP, PER AMM 33-51-12. OPERATIONS CHECK GOOD.SDR SWAA2020111730586Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT L1 DOOR INOPERABLE. RELAMPED EXTERIOR EMERGENCY EXIT LIGHT AT L1 DOOR, IAW AMM 33-51-04.SDR SWAA2021082630597Bracket · brokenRIGHT WING FIXED TRAILING EDGE PANEL ABOVE DEFELCTION ARM HAS BROKEN ANGLE BRACKET. ( MARKED) / REMOVED AND REPLACED BRACKET PER SRM 51-40-02SDR SWAA2021071530593Angle · corrodedAFT CARGO COMPARTMENT ANGLE BELOW FWD SHIELD AT BS 767-787; RBL 24; WL 156; IS CORRODED / REMOVED CORROSION AT AFT CARGO ANGLE BELOW FWD SHIELD AT STA 767-787 RBL 24 IA-W SRM 51-10-02-0G-0. VERIFIED MATERIAL LOSE ORIGINAL 0.050 REMOVED .015 REMAIN .035 ALLOWABSDR SWAA2020111730536Battery Pack · inoperativeLT AFT OVERWING EMERGENCY LIGHTS AND INTERIOR EMERGENCY LIGHT AT ROW 23 INOPERABLE. REMOVED AND REPLACED EMERGENCY EXIT LIGHT BATTERY PACK AT ROW 21, REF AMM 33-51-06. OPERATIONS CHECK NORMAL.SDR SWAA2020111730228Vapor Barrier · crackedRIGHT WHEEL WELL VAPOR BARRIER CRACKED AT BS 663.75 BETWEEN RBL 31.83 AND RBL 45.64 8 INCHES ABOVE LOWER PANEL. CRACK MEASURES 14 INCHES, PERFORMED INTERIM REPAIR BY APPLYING BMS SEALANT AND ONE PLY OF BMS 9-3 FIGERGLASS CLOTH TO DAMAGED AREA, PER SRM 57-10-1SDR SWAA2021062929782Angle · corrodedTHE R/H TRANSITION ANGLE HAS CORROSION FROM STA 787-767 / REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA 767-787 PER SRM 51-40-02SDR SWAA2021062929783Angle · corrodedTHE RIGHT HAND TRANSITION ANGLE IN THE AFT CARGO PIT HAS CORROSION FROM STA 767 TO 727H / REMOVED PART; FABRICATED AND INSTALLED AFT CARGO R/H TRANSITION ANGLE FROM 727H TO 767 PER SRM 53-00-53-2R-5. INSTALLED AND PUSH TESTED NUTPLATES PER SRM 51-40-10.(SA-M 3SDR SWAA2021051229675Skate Angle · damagedRH FWD SKATE ANGLE IS WOEN OUT OF LIMITS / REMOVED AND REPLACED DAMAGED SKATE ANGLE PER SRM 51-40-02; RESTORED INTERIOR FINISH PER AMM 51-21-99.SDR SWAA2021040729660Floor Panel · corrodedAFT CARGO FLOOR PANEL 140CF HAS LIGHT CORROSION ON FLOOR PANEL AROUND DOOR CUT OUT. / FABRICATED AFT CARGO FLOOR PANEL 140CF PER AMM 25-52-01 AND BOEING DRAWING 453A2610-18SDR SWAA2020120329784Angle · corrodedTHE LT TRANSITION ANGLE IN THE AFT CARGO PIT HAS CORROSION FROM STA 817 TO 727J. REMOVED AND REPLACED SECTION OF LT TRANSITION ANGLE IN AFT CARGO FROM STA 727H + 10' TO STA 807 +10' LBL 21', PER SRM 53-00-53-2R-5. SEE SA-M 326; S/N 1200891 FOR INDIVIDUAL WORSDR SWAA2020111630162Position Sensor · faultedON APPROACH INTO MDW THE FLAPS STOPPED AT 8 DEGREE WHEN SELECTED TO 15 ON THE LEVER. DIVERTED TO MKE AND FLAPS WORKED USING ALTERNATE FLAP SELECTOR TO 15 DEGREE. REMOVED AND REPLACED FLAP POSITION SENSOR, PER AMM 27-58-01. OPERATIONS CHECK GOOD ISSUE NR 3078SDR SWAA2021072029524Attach Angle · elongatedFLIGHT DECK DOOR POST FLOOR ATTACH ANGLE ON R/H SIDE HAS 2 EA ELONGATED HOLES / 2EA ELONGATED FLOOR BOARD ATTACH HOLES AT FLIGHT DECK DOOR POST BS 273- BS 276; RBL 10 FOUND OUT OF LIMITS PER SRM 53-10-51-1A-1 REPAIRED DAMAGEDD HOLES IAW EA 20-153-02298SDR SWAA2021071529401Web · corrodedFWD CARGO CENTER THRESHOLD WEB CORRODED IN SEVERAL AREAS. / DAMAGE WAS FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-1. REPLACED WEB PER SRM 51-40-02. (SA-M 326 A1200878)SDR SWAA2021062929528Angle · corrodedFORWARD CARGO RIGHT SIDE TRANSITION HAS CORROSION FIS 500C + 500E / REPAIRED FWD CARGO R/H TRANSITION ANGLE STA 500C TO STA 500E IAW SRM 53-00-53-2R-5SDR SWAA2021060229442Angle · corrodedAFT CARGO COMPARTMENT; AFT BULKHEAD; FLOOR ANGLE; BS947; RBL 24-18; WL 156 CORRODED / REMOVED CORROSION AFT CARGO COMPARTMENT; AFT BULKHEAD FLOOR ANGLE STA 947 RBL 24 - 18 IAW B737 SRM 51-10-02-0G-0 ITEM 15. ORIGINAL 'T' .080 REMAINING .078 LOSS .002. NO PUBLISDR SWAA2020111629451Shuttle Valve · faultyWHEN TAXIING SLOWLY (1-2 KTS) AND TRYING TO STOP THE BRAKES 'RELEASE' SIMILAR TO ANTI-SKID CYCLING AND THE AIRCRAFT COASTS UNTIL YOU PRESS HARDER ON THE BRAKES. PERFORMED AACU BITE CHECK, PER AMM 32-42-00. FOUND FAULT A/B CONT. PERFORMED FIM TASK 32-42 TASSDR SWAA2021082529433Strip · corrodedAFT CARGO COMPARTMENT; FLOOR PANEL LATERAL UNION STRIP; BS773; RBL20-LBL20; WL 156 CORRODED / REPLACED DEFECTIVE PART FOR NEW PART ON PARTS RACK; VERIFIED PART AS MPN 1469401-4 IAW AIPC 53-41-11-26; ITEM 95. PART IS AFT CARGO COMPT. FLOOR PANEL LATERAL UNION SSDR SWAA2021080329275Floorbeam · corrodedCORROSION IN FASTENER HOLF FLOOR BEAM BS 947 LBL 53 (UNDERSIDE) / REMOVED CORROSION FROM NUT PLATE HOLE IAW SRM 51-10-02. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5 & EA 20-153-00267. SEE INDIVIDUAL SIGN OFFS FOR ALL WORK ACCOMPLISHED. SEE ALSO N/R 176705SA-M 3SDR SWAA2021072729195Angle · corrodedCORROSION ON L ANGLE BS 986.5 + 7 RBL 36 / REPLACED ANGLE PER SRM 51-40-02; SEE INDIVIDUAL SIGNOFFS FOR ALL WORK ACCOMPLISHED. (SA-M 326 A1200889)SDR SWAA2021071529419Rail · corrodedFWD PIT LATERAL FLOOR SUPPORT UPPER SURFACE CORRODED AT STA 500I FROM RBL24 TO LBL24 AND W/L157 / NO LIMITS PUBLISHED; FOUND PART OUT OF LIMITS. 100% MATERIAL LOSS ON FWD PIT LATERAL FLOOR SUPPORT (RAIL) STA 500I RBL 24 TO LBL 24. REMOVED AND REPLACED RAIL P/NSDR SWAA2021071529437Channel · crackedRIGHT WING UPPER FIXED T/E PANEL; JUST INBD OF DEFLECTION CONTROL RIB; SUPPORT ANGLE UPPER FLANGE CRACKED THROUGH OTBD FASTENER. / R/H WING FIXED T/E SUPPORT ANGLE CHANNEL CRACKED. DRILLED AND REMOVED CRACKED CHANNEL I/A/W SRM 51-40-02-0G-0. LOCATED AND DRILLESDR SWAA2021060229431Shield · corrodedAFT CARGO COMPARTMENT FLOOR SHIELD BS767-787; RBL 24; WL 156 CORRODED / REMOVED CORROSION AT AFT CARGO FLOORSHIELD BS767 - 787 RBL 24 I-A-W 51-10-02-0G-0. VERIFIED MATERIAL LOOSE ORIGINAL .050 REMOVED .012 REMAIN .038 ALLOWABLE 10% FOUND OUT OF LIMITS USED AARSDR SWAA2021040729416Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140EF CORRODED / EVALUATED CORROSION ON AFT CARGO COMPARTMENT FLOOR PANEL 140EF CORROSION IS MORE THAN 20' IN LONG IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW FLOOR PNL 140EF IAW AMM 25-52-01-201-801 AND BOEING DWG #SDR SWAA2021040729413Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140BF CORRODED / EVALUATED CORROSION AT AFT CARGO COMPARTMENT FLOOR PANEL 140BF FOUND CORROSION EXCESS 20' IN IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW PANEL 140BF IAW AMM 25-52-01-201-801 AND BOEING DWG # 453A2610SDR SWAA2021040729415Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140AF CORRODED / MEASURED LENGTH OF CORROSION DAMAGE TO BE = 42' LIMIT = 20' PANEL 140AF IS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102 FABRICATED NEW PANEL IAW AMM 25-52-01-201-801 AND DWG 453A2610 REV E TREATED ASDR SWAA2021040729412Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140CF CORRODED / AFT CARGO FLOOR PNL 140CF IS CORRODED PNL 140CF IS 'OUT OF LIMITS' IS HAS MORE THAN 20' ACCUMULATED OF CORROSION IAW SRM 53-00-53-1A-1 FIG 102 FABRICATED NEW PNL 140CF IAW AMM 53-00-53-1A-1 STEP F (2) (3) (4) SDR SWAA2021040729414Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140DF CORRODED / EVALUATED CORROSION ON AFT CARGO COMPARTMENT FLOOR PANEL 140DF AND FOUND LENGTH OF ACCUMULATED CORROSION DAMAGE TO EXCEED THE 20' MAXIMUM ALLOWED OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW PANEL 140DF SDR SWAA2021040729233Floorbeam · crackedCABIN FLOOR SUPPORT AT STA 540 BL0 -LBL25 UNDER PANEL 231UF IS CRACKED / REMOVED AND REPLACED CABIN FLOOR PANEL BREAK AT STA 540 BL0 - LBL 25 IAW SRM 51-40-02-0G-0 AND BOEING DWG # 143A0060 REV A APPLIED CIC IAW AMM 51-21-91-620-802SDR SWAA2021040729226Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120AF HAS CORROSION AROUND EDGES / EVALUATED CORROSION AROUND EDGES ON FWD CARGO COMPT FLOOR PANEL 120AF AND FOUND TOTAL ACCUMULATED CORROSION DAMAGE TO EXCEED THE 20' MAXIMUM ALLOWED OUT OF LIMITS IAW SRM 53-00-53-1A-1 NEW PANEL 1SDR SWAA2021040729227Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120CF HAS CORROSION AROUND EDGES / MEASURED CORROSION DAMAGE TO BE = 27' LIMIT = 20' PANEL 120CF IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102 FABRICATED NEW PANEL 120CF IAW AMM 25-52-01-201-801 AND DWG 453A1610 REV - TREATED AND SDR SWAA2021040729225Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120DF HAS CORROSION AROUND EDGES / EVALUATED CORROSION ON FWD CARGO FLOOR PANEL # 120DF DAMAGE EXCEEDS 20IN TOTAL LENGTH OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW PANEL IAW AMM 25-52-01-201-801 APPLIED CHEMICAL CONVERSION SDR SWAA2020120829201Mount · damagedFWD ENTRY DOOR GRIT BAR MOUNTS DAMAGED AT FASTENER HOLES FWD & AFT STA 312 AND 344. REMOVED & REPLACED FWD ENTRY DOOR GRIT BAR MOUNTS FWD & AFT, PER SOPM 25-50-01.SDR SWAA2020120829202Floor Support · crackedMAIN CABIN STA 344-360 LBL 12' INTERCOSTAL CRACKED,AREA MARKED. REMOVED AND REPLACED INTERCOASTAL AT STA 344-360 LBL 12, IAW SRM 51-40-02. SEE SAM FORM A1200877 FOR INDIVIDUAL SIGNOFFS OF WORK PERFORMED. (SA-M 326 A1200877)
Back to Boeing 737-8H4