As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION IN FASTENER HOLF FLOOR BEAM BS 947 LBL 53 (UNDERSIDE) / REMOVED CORROSION FROM NUT PLATE HOLE IAW SRM 51-10-02. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5 & EA 20-153-00267. SEE INDIVIDUAL SIGN OFFS FOR ALL WORK ACCOMPLISHED. SEE ALSO N/R 176705SA-M 326 A1200876INSP D122