Boeing 737-8H4
Service difficulty reports · 24,363
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020052680394Cover · missingEXIT SIGN AT MID CABIN HAS SMALL PANEL MISSING ON THE BACK SIDE CEILING MOUNTED) ( NEF ITEMS LISTED IN MEL APPENDIX 25-10 NON-ESSENTIAL EQUIPMENT & FURNISHINGS (NEF) ) INSTALLED EXIT SIGN COVER IAW AMM 33-51-01.SDR SWAA2021081880446Drain · crackedFWD CABIN FWD ENTRY DOORWAY SCUPPER DRAIN PLASTIC FITTING IS CRACKED / BROKEN AT STA 314 LBL 56. MRKD / REMOVED AND REPLACED FWD CABIN MAIN ENTRY DOORWAY SCUPPER DRAIN PER AMM 53-21-00 AND SRM 51-40-02SDR SWAA2020061780447Support Angle · corrodedFWD SERVICE DOORWAY THRESHOLD SUPPORT ANGLE HAS CORROSION ON UPPER SURFACE STA 305 - STA 325 RBL 57. / REMOVED AND REPLACED FWD SERVICE DOORWAY THRESHOLD SUPPORT ANGLE FRM STA 305 TO STA 325; RBL 57 PER SRM 51-40-02. SEE SA-M 326; S/N A1165195 FOR INDIVIDUAL WSDR SWAA2020061780449Web · corrodedAFT CARGO DOOR THRESHOLD WEB HAS CORROSION. REMOVED & REPLACED AFT CARGO DOOR THRESHOLD WEB IAW SRM 51-40-02SA-M 326 A1165197.SDR SWAA2020061780444Support Angle · corrodedFOWARD ENTRY DOORWAY THRESHOLD SUPPORT ANGLE HAS CORROSION ON UPPER SURFACE AT STA 314 -STA 320 LBL 61.SDR SWAA2021062989454Scuff Plate · brokenFWD CARGO FWD CORNER THRESHOLD PIECE BROKEN. / REMOVED AND REPLACED FWD CARGO FWD CORNER LWR. SCURR PLATE PER SRM 51-40-05; SRM 51-40-08 AND MM 53-11-02SA-M 326 A1165220INSP D54SDR SWAA2021062489455Scuff Plate · brokenFWD CARGO AFT CORNER THRESHOLD PIECE BROKEN / REMOVED AND REPLACED FWD CARGO LWR AFT CORNER SCUFF PLATER PER SRM. 51-40-05; SRM. 51-40-08 AND MM. 53-11-02SA-M 326 A1165023SDR SWAA2020052680006Battery Pack · failedEMERGENCY BATTERY PACK IN AFT GALLEY CEILING LT FAILS CAPACITY CHECK. REPLACED LT EMERGENCY BATTERY PACK IN AFT GALLEY CEILING PER AMM 33-51-06.SDR SWAA2020052680007Battery Pack · dischargedEMERGENCY LIGHTS AT ROW20ABC FAILS CAPACITY CHECK. REPLACED EMERGENCY BATTERY PACK AT SEAT ROW 20 ABC PER AMM 33-51-06.SDR SWAA2021080379801Floorbeam · crackedCRACK IN FLOOR STRUCTURE (FLOOR BOARD PANEL 231UF AFT MOUNT BRACKET); AT STA540; 2 RBBL; WL208. / REMOVED CRACKED PANEL BREAK ASSY PER SRM 51-40-02-0G-0. INSTALLED SERVICABLE REPLACEMENT PN # 143A5240-36 @ STA 540; 0 BL - 24 RBL; WL 208 PER DWG # 143A0060 AND SDR SWAA2021080379800Floorbeam · crackedCRACK IN FLOOR STRUCTURE (FLOOR BOARD PANEL 231UF AFT MOUNT BRACKET); AT STA540; 2 LBBL; WL208. / REMOVED CRACK PANEL BREAK ASSY. PER SRM 51-40-02-0G-0. INSTALLED REPLACEMENT SERVICABLE PN # 143A5240-35 PER DWG # 143A0060 + SRM 51-40-02-0G-0 @ STA 540; 0 BL - SDR SWAA2021060279798Vapor Barrier · crackedRIGHT HAND MAIN LANDING GEAR FORWARD BULKHEAD AT B.S. 540 VAPOR BARRIER CRACKED IN TWO (2) LOCATIONS.PERFORMED INTERIM REPAIR PER REPAIR 57 EA-07683 FOR FURTHER CORRECTIVE ACTION REF 943 & #V005123REPETITVE ACTION REQUIRED:REMOVE ALUM FOIL TAPE AND PERFORM DETSDR SWAA2021060279797Vapor Barrier · crackedRIGHT HAND MAIN LANDING GEAR FORWARD BULKHEAD AT B.S. 540 VAPOR BARRIER CRACKED IN TWO (2) LOCATIONS.PERFORMED INTERIM REPAIR PER REPAIR 57 EA-07683 FOR FURTHER CORRECTIVE ACTION REF 943 & #V005123REPETITVE ACTION REQUIRED:REMOVE ALUM FOIL TAPE AND PERFORM DETSDR SWAA2020060479804Attach Angle · crackedLEFT HAND STA 663, LOWER ATTACH ANGLE, CRACKED AT LBL 7. REMOVED DAMAGED SECTION OF LEFT HAND STA 663, LOWER ATTACH ANGLE AT LBL 7 AND REPAIRED IAW SRM 51-10-10-2R-5 LEAK. CHECKED REPAIR AREA IAW AMM 28-11-00-400-801. LEAK CHECK GOOD.SDR SWAA2020060380012Baffle · crackedFORWARD CARGO COMPARTMENT LT BAFFLE, BS 500F - 500G, LBL 24 AND WL 156 CRACKED ON UPPER FLANGE. REMOVED CRACKED BAFFLE LT BS 500F TO 500G, LBL 24 AND WL 156 IAW SRM 51-40-02-0G-0. FABRICATED BAFFLE FROM 7075-T6 0.020 PO 473961/3 IAW SRM 51-30-01-0G-0 AND DWGSDR SWAA2020052179634Battery Pack · dischargedFWD ENTRY DOOR EMERGENCY LIGHTS INOP / R+R FWD EMERGENCY LIGHTS BATTERY PACK PER AMM 31-51-06SDR SWAA2021081679654Shield · corroded***CORROSION*** RH SHIELD AFT OF FWD CARGO DOOR STA 492 TO 500A RBL 23.5 WL 156 / REMOVED DAMAGED R/H SHIELD AFT OF FWD CARGO DOOR STA 492 TO 500A RBL 23.5 WL 156 IAW SRM 51-40-02. INSTALLED NEW R/H SHIELD PO # 793670 AFT OF FWD CARGO DOOR STA 492 - 500A RBL 2SDR SWAA2021071579337Support Angle · crackedAFT CARGO PIT FLOOR SUPPORT AT STA 727 CRACKED IN 2 PLACES / REPLACED FLOOR SUPPORT ANGLE AT AFT CARGO NEW ANGLE PART #453A2611-25 I-A-W BOEINBG DWG 453A2600 REV:B ANGLE INSTALLED ON AAR N/R Y222735 ATAG# WN4941SDR SWAA2020060379658Support Angle · corrodedCORROSION AFT BULKHEAD LT LOWER SUPPORT ANGLE STA 500I, LBL 32.5, S23L AND WL 160. CORROSION ON FWD CARGO AFT BULKHEAD LT LOWER SUPPORT ANGLE STA 500I, PN 143A9485-23 FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN SRM. REMOVED AND REPLACED AFT BULKHEAD LT LOWSDR SWAA2020060379659Channel · corrodedCORROSION FWD CARGO COMPARTMENT LT ZEE CHANNEL, STA 500C+9 TO STA 500I, WL 156 AND LBL 24. CORROSION ON FWD CARGO LT ZEE CHANNEL, STA 500C+9 - 500I FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED FWD CARGO LT ZEE CHANNEL PN 143A7501-81 SDR SWAA2020060379656Support Angle · corrodedCORROSION AFT BULKHEAD LOWER SUPPORT ANGLE STA 500I, RBL 25 TO LBL 25 AND WL 156. REMOVED AND REPLACED AFT BULKHEAD WITH NEW LOWER SUPPORT ANGLE STA 500I, RBL 25 TO LBL 25 AND WL 156 PO 778494 IAW SRM 51-40-02, SRM 51-40-05 AND DWG 143A9481, DUE TO NO LIMITS SDR SWAA2020060379655Channel · corrodedCORROSION FWD CARGO COMPARTMENT RT ZEE CHANNEL, STA 500A+11.5 TO STA 500I, RBL 24 AND WL 156. REMOVED FWD CARGO COMPARTMENT RT ZEE CHANNEL STA 500A+11.5 TO STA 500I, RBL 24 AND WL 156 IAW SRM 51-40-02. REPLACED RT ZEE CHANNEL WITH NEW ZEE CHANNEL PO 774274 ISDR SWAA2020052679282Seat Track · damagedCAPTIONS I/B AFT SEAT TRACK TO LIMITS. R AND R CAPTIONS I/B AFT SEAT TRACK PER AMM 25-11-11.SDR SWAA2020052179650Glowstrip · faultyL/H FWD EMERGENCY OVERWING EXIT SIDEWALL LIGHT HALF ILLUMINATED ( CABIN INTERIOR ILLUM BOEING SKY INTERIOR PHOTOLUMINESCENT ) / REPLACED LH FWD EMERGENCY EXIT WINDOW LIGHT ASSY IAW AMM 33-21-00. OPS CHK GOOD CL# 76655SDR SWAA2021081679169Attach Bracket · crackedCRACKED BRACKET ATTACHING RH WING DEFLECTION CONTROL RIB TO OUTBOAD END OF WING T/E PANEL RIB. APPROX. WS 282. / REMOVED CRACKED BRACKET + INSTALLED NEW BRACKET P/N 115A6260-2 IAW SRM 51-40-02-0G-0 + BOENG DWG 115A6200SDR SWAA2021081679062Shield · corrodedFORWARD CARGO PIT; RIGHT HAND SIDE SHIELD HAS CORROSION; BS:480+12 TO 500; RBL:24; WL:146. / REMOVED CORROSION ON R/H SHIELD @ STA 480+12' TO 500 IAW B737 SRM 51-10-02-0G-0 ORIGINAL MATERIAL IS .040 MATERIAL LOSS .009 MATERIAL REMAINING .031 MATERIAL WAS FOUNDSDR SWAA2021081679311Shield · corroded***CORROSION*** FWD CARGO SHIELD IN AFT CARGO BAY HAS MULTIPLE AREAS OF CORROSION FROM STA 767-794; RBL21; WL 158 / REMOVED DAMAGED FWD CARGO SHIELD IN AFT CARGO BAY STA 767-794; RBL 21; WL 158. INSTALLED NEW PART PN# 146A8127-12 PO# 777849 IAW SRM 51-40-02 ANSDR SWAA2021080579071Strip · corrodedAFT CARGO COMP.FLOOR PANEL SIDEWALL STRIPS CORRODED AROUND FASTNER HOLES BACK SIDE (1 EACH STRIPS) / EVALUATED CORROSION AT AFT CARGO COMP FLOOR PANEL SIDEWALL STRIP AT R/H STA 727E TO STA 727J THERES NO SRM REFERENCE TO BLEND CORROSION REPLACED FLOOR PANEL SISDR SWAA2021080579069Floor Panel · corrodedAFT CARGO COMP.FLOOR PANEL 140BF HAS CORROSION AROUND EDGE FASTNER HOLES / REMOVED CORROSION IAW SRM 51-10-02-0G-0 AND INSPECTED WITH 10X MAG; ACCULULATED DAMAGE LENGTH EXCEED 20'; LIMIT=20'; DAMAGE=40' FOUND OUT OF LIMIT IAW SRM 53-00-53-1A-1; VERIFIED MATERISDR SWAA2021080579068Floor Panel · corrodedAFT CARGO COMP.FLOOR PANEL 140AF HAS CORROSION AROUND EDGE FASTNER HOLES / REMOVED CORROSION FROM AFT CARGO FLOOR PANEL 140AF IAW SRM 51-10-02-0G-0 PAR 15 AND INSPECTED W/ 10X MAG GLASS. TOTAL LENGTH OF DAMAGE = 40 INCHES TOTAL LENGTH OF DAMAGE ALLOWED = 20 INSDR SWAA2021071579065Support Angle · corrodedFORWARD CARGO PIT; LOWER MIDDLE AFT BULKHEAD SUPPORT ANGLE HAS CORROSION; BS:500I; RBL:24 TO LBL:24; WL:146. / EVALUATED ALLOWANCE DAMAGE AT FWD CARGO PIT LOWER MIDDLE AFT BULKHEAD SUPPORT ANGLE (RAIL) 100% MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW B737 SRM SDR SWAA2021071579066Support Angle · corrodedFORWARD CARGO PIT; LEFT HAND SIDE AFT BULKHEAD SUPPORT ANGLE HAS CORROSION; BS:500I; LBL:25; WL:146. / REMOVED CORROSION FROM FWD CARGO L/H AFT BULKHEAD SUPPORT STA 500I LBL 25 ORIG 'T' 0.071' REMOVED 0.001' REMOANONG 0.070' WITHIN TOLERANCES IAW DWG 143A9485 SDR SWAA2020060579067Angle · corrodedFORWARD CARGO PIT LEFT HAND Z-ANGLE HAS CORROSION BS 500D TO 500I LBL 24 WL 146. REMOVED CORROSION AT FWD CARGO PIT LEFT HAND Z-ANGLE STA 500D TO 500I LBL 24 IAW SRM 51-10-02-0G-0 ITEM 15. ORIGINAL 'T' .040 REMAINING .034 LOSS .006 AT BETWEEN STA 500G TO 500FSDR SWAA2020060580013Floorboard · damagedPANEL 241DF UPPER SURFACE LOOSE/FRAYED FIBERS. REPAIRED DAMAGE FIBERS ON FLOORBOARD 241DF IAW SRM 53-00-50-2R-1 REV 69 AND SRM 53-00-50-2R-0 REPAIR GENERAL REV 69.SDR SWAA2020060579335Floor Panel · damagedLEFT SIDE FLOOR PANEL 241BF HAS STRANDS OF FIBER THAT HAS BEEN PULLED OFF. REPAIRED DAMAGED FIBERS ON FLOORBOARD 241BF IAW SRM 53-00-50-2R-1 REV 69 AND SRM 53-00-50-2R-0 REPAIR GENERAL REV 69.SDR SWAA2020060579190Floor Panel · damagedRIGHT SIDE FLOOR PANEL 232QF STRANDS OF FIBER PULLED IN SERVERAL AREAS ACROSS FLOOR PANEL. AREAS OF PULLED FIBER STRANDS REPAIRED ON FLOOR PANEL 232QF IAW SRM 53-00-50-2R-1 PARA 3.SDR SWAA2020060579063Angle · corrodedFORWARD CARGO PIT; RIGHT HAND Z-ANGLE HAS CORROSION; BS 500A TO 500I RBL 24 WL 146. REMOVED CORROSION AT FWD CARGO PIT RT Z-ANGLE AT STA 500A TO 500I RBL 24. IAW SRM 51-10-02-0G-0 ITEM 15. ORIGINAL 'T' .040 REMAINING .033 LOSS .007 AT BETWEEN STA 500C TO 500SDR SWAA2020060379314Attach Angle · crackedCUSTOMER REQUEST LT STA 663 UPPER ATTACH ANGLE LBL 8 IS CRACKED. REPAIRED LT STA 663 UPPER ATTACH ANGLE LBL 8 IAW SRM 57-10-10-2R-5.SDR SWAA2020060379313Attach Angle · crackedCUSTOMER REQUEST RT STA 663 UPPER ATTACH ANGLE RBL 8 IS CRACKED. REPAIRED DAMAGED RT 663 UPPER ATTACH ANGLE RBL 8 IAW SRM 57-10-10-2R-5.SDR SWAA2020060379310Channel · corrodedCORROSION RT Z-CHANNEL IN AFT CARGO BAY HAS MULTIPLE AREAS OF CORROSION FROM STA 727-767, RBL21 AND WL 158. CORROSION ON RT Z-CHANNEL IN AFT CARGO BAY FROM STA 727 - 767, RBL 21 AND WL 158 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL D. FABSDR SWAA2020060379309Channel · corrodedCORROSION LT Z-CHANNEL IN AFT CARGO BAY HAS MULTIPLE AREAS OF CORROSION FROM STA 727-847, LBL 21 AND WL 158. REMOVED LT Z-CHANNEL IN AFT CARGO AND INSTALLED NEW Z-CHANNEL O/N 146A1502-31 PO 786416 IAW SRM 51-40-02 AND B DWG 146A7500.SDR SWAA2020060279306Doubler · crackedCUSTOMER REQUEST ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER CRACKED AT FASTENER COMMON TO LOWER RUBBING BLOCK. REMOVED DAMAGE FROM BOTTOM OF ELECTRICAL GROUND POWER RECEPTACLE CUT-OUT IAW SRM 53-10-15-2R-4. FABRICATED REPAIR PARTS 2 DOUBLER .050 707SDR SWAA2020052179275Power Supply · inoperativeFLIGHT DECK EMERGENCY LIGHT IS NOT WORKING / REMOVED; REPLACED AND PERFORMED GOOD INSTALLATION TEST OF M1675 EMERGENCY EXIT LIGHT BATTERY PACK POWER SUPPLY IAW AMM 33-51-06-960-806. FLIGHT DECK EMERGENCY LIGHT CHECKS GOOD ATAG: WN0141SDR SWAA2021081578855Shield · corrodedAFT CARGO PIT FLOOR; RH SIDE SHIELD HAS CORROSION; BS:767 TO 787; RBL: 22; WL: 156. / REMOVED .026' MATERIAL FROM ORIGINAL .050' THICKNESS AFT CARGO FLOOR SIDE SHEILD STA 767-787 RBL 22 WL156. REMAINIG .024' IS OUT OF LIMITS IAW SRM 53-60-15-1A-1. REMOVED EXISSDR SWAA2021080578852Floor Panel · corrodedFWD CARGO COMPARTMENT FLOOR PANEL 120AF HAS CORROSION ON EDGES OF PANEL; MARKED. / EVALUATED FWD CARGO COMPARTMENT FLOOR PANEL 120AF FOUND TO EXCEED 20' MAXIMUM LENGTH IAW SRM 53-00-53-1A-1. FABRICATED NEW FLOOR PANEL IAW AMM 25-52-01-201-801SDR SWAA2021080578853Floor Panel · corrodedFWD CARGO COMPARTMENT FLOOR PANEL 120DF HAS CORROSION ON EDGES; MARKED. / EVALUATED CORROSION AT FWD CARGO COMPARTMENT FLOOR PANEL 120DF FOUND TO EXCEEDS 20' MAXIMUM LENGTH OUT OF LIMITS I/A/W SRM 53-00-53-1A-1; FABRICATED NEW PNL 120DF I/A/W AMM 25-52-01-201-SDR SWAA2021080578850Floor Panel · corrodedFWD CARGO COMPARTMENT FLOOR PANEL 120CF HAS SEVERAL AREAS OF CORROSION ON BOTH INBD AND OUTBD EDGES; MARKED. / FABRICATED NEW FWD CARGO FLOOR PANEL 120CF I/A/W AMM 25-52-01-201; AMM 51-00-58-201; AMM 51-21-72-370 AND SRM 53-00-33-1A; AND AMM 51-21-91-620SDR SWAA2020060578856Angle · corrodedAFT CARGO PIT FLOOR LT Z-ANGLE HAS CORROSION BS 727E TO 787 LBL 22 WL 156. REMOVED CORROSION AT LT Z ANGLE STA 727 E TO 787 LBL 22 AS MARKED IAW SRM 53-00-53-1A-2. ORIGINAL THICKNESS .040'; AFTER REWORK .028'; .012' MATERIAL LOSS; OUT OF LIMITS IAW SRM 53-00-SDR SWAA2020060478857Angle · corrodedAFT CARGO PIT FLOOR, RT Z-ANGLE HAS CORROSION, BS 727C TO 767, RBL 22 AND WL 156. REMOVED CORROSION FROM AFT CARGO RT Z-ANGLE, BS 727C TO 767 AND RBL 22. ORIGINAL MATERIAL THICKNESS .040, LOSS OF .009 WITH .031 IS OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVESDR SWAA2020052078609Light · faultySUPPLEMENTAL INFORMATION: L/H FWD EMERGENCY OVERWING EXIT SIDEWALL LIGHT HALF ILLUMINATED ( CABIN INTERIOR ILLUM BOEING SKY INTERIOR PHOTOLUMINESCENT ) / DMA# 0425642REPLACED LH FWD EMERGENCY EXIT WINDOW LIGHT ASSY IAW AMM 33-21-00. OPS CHECK GOODCLEAR# 76655
Back to Boeing 737-8H4