What was found
CUSTOMER REQUEST ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER CRACKED AT FASTENER COMMON TO LOWER RUBBING BLOCK. REMOVED DAMAGE FROM BOTTOM OF ELECTRICAL GROUND POWER RECEPTACLE CUT-OUT IAW SRM 53-10-15-2R-4. FABRICATED REPAIR PARTS 2 DOUBLER .050 7075T6 LOT 5032596 -3 AND FILLER, .040 2024T3 LOT 5087758. INSTALLED REPAIR PARTS ON ELECTRICAL GROUND POWER RECEPTACLE IAW SRM 51-40-02-0G-0 AND SRM 53-10-15-2R-4.