Boeing 737-8H4
Service difficulty reports · 24,363
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021080534834Floor Panel · corrodedFWD PIT FLOOR PANEL 120CF HAS CORROSION / REMOVED CORROSION FROM FWD CARGO PANEL # 120CF 30 INS OF CORROSION FROM R/H SIDE OF PANEL ALLOWED 20' OUT OF LIMITS I/A/W 737-800 SRM 53-00-53-1A-1 FABRICATED PANEL # 120 CF I/A/W 737 AMM 25-52-01-201-801; 737 AMM 51-2SDR SWAA2021080534833Floor Panel · corrodedFWD PIT FLOOR PANEL 120AF HAS CORROSION / EVALUATED CORROSION ON FWD PIT FLOOR PNL 120AF FOUND TO BE OUT OF LIMITS AS ACCUMULATED DAMAGE IS OVER 20' IAW SRM 53-00-53-1A-1 FIG 103; VERIFIED MAT IAW AIPC 25-52-10-17; SRM 53-30-53-01-1; AND BOEING DWG 452A1610 RESDR SWAA2021080534919Floor Panel · corrodedFWD PIT FLOOR PANEL 120DF IS CORRODED / DUE TO TOTAL CORROSION DAMAGE OF PANEL 120DF OVER 20' FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-1 FIG 102. FABRICATED A NEW FLOOR PANEL IAW B737 AMM 25-52-01-201-801 STEP F. TREATED AND PRIMED PANEL IAW B737SDR SWAA2021080534920Floor Panel · corrodedFWD PIT FLOOR PANEL 120AF IS CORRODED / EVALUATED FWD CARGO PIT FLOOR PANEL 120AF OUT OF LIMITS IAW SRM 53-00-53-1A-1; FIG 102; FABRICATED NEW FLOOR PANEL 120AF IAW 737 AMM 25-52-01-201-801; TREATED LOWER SURFACE IAW 737 AMM 51-21-41-370-802 APPLIED PRIMER TO SDR SWAA2021080534918Floor Panel · corrodedFWD PIT FLOOR PANEL 120CF IS CORRODED / REPLACED CORRODED FWD PIT FLOOR PANEL 120CF; VERIFIED MATERIAL AS .071; 2024 T3; ATAG # A39946; AND FABRICATED REPLACEMENT PANEL IAW AMM 25-52-01SDR SWAA2021080534914Floor Panel · corrodedAFT PIT FLOOR PANEL 140DF IS CORRODED / REPLACED AFT PIT FLOOR PANEL 140DF; VERFIED MATERIAL AS .071; 2024 T-3; AND FABRICATED REPLACEMENT PANEL IAW AMM 25-52-01SDR SWAA2021080534915Floor Panel · corrodedAFT PIT FLOOR PANEL 140BF IS CORRODED / REPLACED AFT PIT FLOOR PANEL 140BF; VERFIED MATERIAL AS .071; 2024 T-3; AND FABRICATED REPLACEMENT PANEL IAW AMM 25-52-01 A39933SDR SWAA2021080534913Floor Panel · corrodedAFT PIT FLOOR PANEL 140CF IS CORRODED / REMOVED CORROSION IAW SRM 51-10-02-0G-0 FOUND TO HAVE CORROSION LONGER THAN 20'. FOUND TO BE OUT OF LIMITS. VERIFIED NEW MATERIAL FOUND TO BE .071 2024-43 IAW SRM 25-52-01-201-801. FABRICATED NEW FLOOR PANEL 140CF IAW SRSDR SWAA2021080534912Floor Panel · corrodedAFT PIT FLOOR PANEL 140EF IS CORRODED / AFT PIT FLOOR PANEL 140EF EXCEEDED 20' OF CORROSIION; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. FABRICATED NEW PANEL IAW 25-52-01-201-801/ TREATED AND PRIMED IAW SRM 51-20-01-0G-0/ AMM 51-21-72-370-804 TAG A39935SDR SWAA2021080534921Strip · crackedAFT PIT #1 CAPSTRIP SPLICE IS CRACKED OUT / VERIFIED NEW CAP STRIP SPLICE PART # 453A21611-13; A-TAG # A03654 IAW B737 AIPC 25-52-10-04 ITEM # 460. CRACKED CAP STRIP FOR AFT PIT REPLACED WITH NEW CAPSTRIP ON WORK BENCH; INSTALLED ON SA-M 565S.SDR SWAA2020050434778Intercostal · bentINTERCOSTAL WEB BETWEEN FRAME STATIONS 500D AND 500E IS BENT. REFERENCE LOCATION STRINGER 25R / AT STR.25R/STA 500D-500E REMOVED AND REPLACED INTERCOASTAL WEB PER SRM 51-40-02.SA-M 326 ATTACHED A1164487SDR SWAA2020050434777Intercostal · bentINTERCOSTAL WEB BETWEEN FRAME STATIONS 500E AND 500F IS BENT. REFERENCE LOCATION STRINGER 25R / AT STR-25R/STA 500E-500F REMOVED AND REPLACED INTERCOASTAL WEB PER SRM 51-40-02SA-M 326 A1164486 ATTACHEDSDR SWAA2020050434776Intercostal · bentINTERCOSTAL WEB BETWEEN FRAME STATIONS 500G AND 500H IS BENT. REFERENCE LOCATION STRINGER 25R / REMOVED AND REPLACED INTERCOSTAL AT FWD CARGO; STA. 500G - 500H; STR - 25R PER SRM 51-40-02(SA-M 326 ATTACHED: A1164488)SDR SWAA2020042234838Attach Angle · crackedRIGHT HAND A/C BAY EVIDENCE OF CRACK AT FASTENER ON VAPOR BARRIER ATTACH ANGLE AT STA 663 APPROX RBL 9 / TRIMMED DAMAGED VAPOR BARRUER ATTACH ANGLE OUT FROM R/H STA 663 VAPOR BARRIER; FABRICATED P/N 4064019 00001 REPAIR ANGLE ; P/N 4064019 000002 REPAIR SPLICESDR SWAA2020042234821Web · crackedRH WING TRAILING EDGE; ORSS 297 - 16; 15' AFT OF REAR SPAR. LATTERAL WEB IS CRACKED IN UPPER FLANGE AT RIVET COMMON TO UPPER TRAILING EDGE PANEL / REMOVED CRACKED WEB AT R/H WING TRAILING EDGE AFT OF REAR SPAR LATTERAL WEB IA-W SRM 51-40-02-0G-0. DRILLED NEW WSDR SWAA2020040134769Light · inoperativeCEILING EMERGENCY EXIT LIGHT OVER ROW 27 ABC INOP. / REMOVED AND REPLACED CEILING AISLE EMERGENCY EXIT LIGHT ASSEMBLY OVER SEAT ROW 27 ABC PER AMM 33-51-03. OPS CHECK NORMAL AT THIS TIMESDR SWAA2020040134784Pump · failedA HYDRAULIC SYSTEM ENGINE DRIVEN PUMP LOW PRESSURE ILLUMINATED DURING CLIMB. A HYD. SYS. QTY INDICATED 105% UNTIL START OF DESCENT. A HYD. QTY. RAPIDLY DROPPED TO 20% AND HELD STEADY FOR REMAINDER OF FLIGHT. / FOUND UPPER CASE DRAIN LINE LOOSE FROM PYLON DISCOSDR SWAA2020040134812Eec · faultyON TAKEOFF; LEFT ENG CONTROL LIGHT ILLUMINATED. (LOW SPEED REJECT) APPROX 60-70 KTS / R&R #1 ENG EEC PER MM 73-21-60. ISSUE # 2845700. POS 1 P/N OFF 2042M67P02 S/N OFF FFFB0038 P/N ON 2042M67P04 S/N ON FFFH2497SDR SWAA2020032734788Floor Panel · poppedSUPPLEMENTAL INFORMATION: CENTER AISLE ABEAM ROW 17 THE FLOOR MAKES A POPPING SOUND WHEN YOU WALK ON IT. PERFORM GENERAL VISUAL EXAMINATION OF THE PANEL TO ENSURE PANEL IS FREE OF DEFECTS (CRACKS; DENTS; PUNCTURES; ETC.) IF DEFECTS ARE NOTED CONTACT SERVICE ENSDR SWAA2020032734763Vapor Barrier · crackedSUPPLEMENTAL INFORMATION: L.H W/W VAPOR BARRIER HAS A CRACK 6' IN LENGTH. C/W REPAIR PER SRM 57-10-10-1A-2 REPETITIVE ACTION REQUIRED DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FREQUENTLY. MAKE SURE THAT CRACK HAS NOT GROWSDR SWAA2021071634885Access Panel · corrodedRIGHT WING; FUEL TANK TANK ACCESS HOLE 632LB; LIP HAS FRETTING CORROSION. / REMOVED CORROSION FROM R/H WING FUEL TANK ACCESS HOLE 632LB LIP REMAINING THICKNESS 0.197' LIMITS IAW SRM 57-20-01-2R-1. REPAIRED IAW SRM 57-20-01-2R-1.SDR SWAA2021050634779Seal · damagedRH HORIZ. STAB. FWD SLIDING SEAL. FWD TRACK IS DAMAGED FROM SEAL CUTTING INTO. / REMOVED AND REPLACED R/H HORIZ. STAB. FWD. SLIDING SEAL FWD. LWR. TRACK PER SRM 51-40-02. SEE SAM FORMS FOR ADDITIONAL SIGN OFFS. (SA-M 326 ATTACHED # A1164493)SDR SWAA2020050434772Angle · damagedPREVIOUSLY SPLICED TRANSITIONAL ANGLE OUT OF LIMITS AT TA 500A-50013 AND STA 500H-500I (REPLACE COMPLETE ANGLE) R/H SIDE. / INSTALLED NEW SERVICEABLE RH TRANSITION ANGLE FROM STA 500 A TO STA 500 I IAW SRM 51-40-02SDR SWAA2020033134763Vapor Barrier · crackedL.H W/W VAPOR BARRIER HAS A CRACK 6' IN LENGTH. C/W REPAIR PER SRM 57-10-10-1A-2 REPETITIVE ACTION REQUIRED DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FREQUENTLY. MAKE SURE THAT CRACK HAS NOT GROWN PAST THE INTERIM SEAL /SDR SWAA2020033134788Panel · unknownCENTER AISLE ABEAM ROW 17 THE FLOOR MAKES A POPPING SOUND WHEN YOU WALK ON IT. PERFORM GENERAL VISUAL EXAMINATION OF THE PANEL TO ENSURE PANEL IS FREE OF DEFECTS (CRACKS; DENTS; PUNCTURES; ETC.) IF DEFECTS ARE NOTED CONTACT SERVICE ENGINEERING. PERFORMED PERMASDR SWAA2020033134814Light · loosePHOTO ILLUMINENCENT FLOOR LIGHTING IS LOOSE AT SEAT POSITION 20C / RESECURED FLOOR LIGHTING AT 20C PER S.I.PSDR SWAA2020033134537Filter · faulty'A' ENG HYD LOW PRESS ILLUMINATED AT TOP OF CLIMB. AT GATE A HYD QTY DROPPED TO 21% / R/R 'A' SYSTEM EDHP ISSUE #2844446 IAW AMM 24-11-11. INSPECTED AND REPLACED 'A' SYSTEM CASE DRAIN FILTER IAW AMM 29-11-51. INSPECTED AND REPLACED 'A' SYSTEM EHDP CASE DRAIN FSDR SWAA2020032634434Floor Panel · noisySUPPLEMENTAL INFORMATION: FLIGHT ATTENDANTS REPORTED CENTER AISLE ABEAM ROW 17 MAKES BANG WHEN THEY STAND IN CENTER AISLE. SOUND NOT HEARD WHEN STANDING SEATING IN SEAT ROW. C/W EA NO. 1-A53-31403 REV 1 REPETITIVE INSPECTION ACTION: ACTION REQUIRED: PERFORM GESDR SWAA2021081734574Slide · out of positionFA'S REPORT FWD ENTRY ESCAPE SLIDE RETENTION BAR VERY DIFFICULT TO GET INTO AND OUT OF FLOOR MOUNTED BRACKETS. / REPOSITION SLIDE OPS CK OK PER MT 725-61-05SDR SWAA2021070234375Angle · corrodedFWD CARGO COMPARTMENT RH TRANSITION ANGLE HAS SEVERE AREAS OF SURFACE CORROSION FROM STA 500B TO 500C / REPLACEMENT OF TRANSITION ANGLE TO BE ACCOMPLISHED ON NR# D441272 FROM STA 500A-500ISDR SWAA2021070234376Angle · corrodedFWD CARGO COMPARTMENT RH TRANSITION ANGLE HAS SEVERE AREAS OF SURFACE CORROSION FROM STA 500A TO 500B / REPLACEMENT OF TRANSITION ANGLE TO BE ACCOMPLISHED ON NR# D441272 FROM STA 500A-500ISDR SWAA2021070234373Angle · corrodedFWD CARGO COMPARTMENT RH TRANSITION ANGEL HAS SEVERE AREAS OF SURFACE CORROSION FROM STA 500D TO 500E / REPLACEMENT OF TRANSITION ANGLE TO BE ACCOMPLISHED ON NR# D441272 FROM STA 500A-500ISDR SWAA2021050534392Seal · damagedPANEL 333AB SLIDER SEAL DAMAGED / R&R'D SEAL PER SRM 51-40-02SDR SWAA2021050534393Seal · damagedPANEL 343AB SLIDER SEAL DAMAGED / R&R'D SEAL PER SRM 51-40-02SDR SWAA2021042934378Stringer Clip · crackedFWD CARGO COMP HAS A CRACKED STR METER CLIP AT STA 500H. STR 24L; FFEC VERIFIED PER 737 NDT MANUAL PART 6 51-00-00 PROC 23. / DAMAGE LOCATION INCORRECTLY IDENTIFIED AS STRINGER 24L. CRACK IS ON STRINGER CLIP 26L. REFERNECE NON- ROUTINE CARD D332425SDR SWAA2020050434386Floor Panel · damagedCABIN FLOOR PANELS 241AAF; AND 241 ABF DAMAGED / INSPECTED. REMOVED AND REPLACED CABIN FLOOR PANELS 241AAF; AND 241ABF PER AMM 53-21-00SDR SWAA2020050434387Floor Panel · damagedCABIN FLOOR PANELS 242RF; 242SF DAMAGED / INSPECTED REMOVED AND REPLACED CABIN FLOOR PANELS 242RF AND 2425F PER AMM 53-21-00SDR SWAA2020050434388Floor Panel · damagedCABIN FLOOR PANELS 242D; 242E AND 242F DAMAGED / INSPECTED. REMOVED AND REPLACED CABIN FLOOR PANELS 242D; 242E; AND 242F PER AMM 53-21-00.SDR SWAA2020050434389Floor Panel · damagedCABIN FLOOR PANEL 242UF DAMAGED / INSPECTED. REMOVED AND REPLACED CABIN FLOOR PANEL 242UF PER AMM 53-21-00.SDR SWAA2020050434380Floor Panel · damagedCABIN FLOOR PANELS DAMAGED; ZZ1AF;ZZ1BF; ZZ1CF AND ZZ1DF / REMOVED AND REPLACED CABIN FLOOR PANELS 221AF; 221BF; 221CF AND 221ADF PER AMM 53-21-00(INSPECTED BY D128)SDR SWAA2020050434381Floor Panel · damagedCABIN FLOOR PANELS 221EF; 221FF; 221GF DAMAGED / REMOVED AND REPLACED CABIN FLOOR PANELS 221EF; 221FF; 221GF; PER AMM 53-21-00. INSPECTED.SDR SWAA2020050434382Floor Panel · damagedCABIN FLOOR PANELS 222AF AND 222BF DAMAGED / REMOVED AND REPLACED CABIN FLOOR PANELS 222AF AND 222BF PER AMM 53-21-00. INSPECTEDSDR SWAA2020050434383Floor Panel · damagedCABIN FLOOR PANELS 222CF AND 222DF DAMAGED / REMOVED AND REPLACED CABIN FLOOR PANELS 222CF AND 222DF PER AMM 53-21-00. INSPECTEDSDR SWAA2020050434384Floor Panel · damagedCABIN FLOOR PANELS 241XF; 241YF AND 241ZF DAMAGED / REMOVED AND REPLACED CABIN FLOOR PANELS 241XF; 241YF; AND 241ZF PER AMM 53-21-00.INSPECTEDSDR SWAA2020050434385Floor Panel · damagedCABIN FLOOR PANELS 241D; 241E; AND 241F DAMAGED / REMOVED AND REPLACED CABIN FLOOR PANELS 241D; 241E; AND 241F PER AMM 53-21-00. INSPECTEDSDR SWAA2020041334568Attach Angle · crackedAFT PIT BS867; LBL12; OTBD SIDE OF FLOORBOARD ATTACH ANGLE; CLIP CRACKED. / REMOVED AND REPLACED AFT CARGO ATTACH CLIP STA 867 LBL 12 OTBD SIDE OF FLOORBOARD ATTACH IAW SRM 51-40-02 AND BOEING DWG 149A8102 REV A. ATAG A34482 PN: 149A8109-114SDR SWAA2020041334415Angle · corrodedAFT CARGO PIT RIGHTHAND Z ANGLE HAS CORROSION FROM STA. 727D TO STA. 727G APPROX. WL 156 RBL 20 / AFT CARGO RH Z-ANGLE STA 727D TO 727 6 REPAIRED ON SOUTHWEST NRC Y200113; REMOVED CORROSION ON Z-ANGLE IAW SRM 51-10-02-0G-0. MEASURED MATERIAL LOSS TO BE .007' OSDR SWAA2020041334411Angle · corrodedBS727H-BS767 RBL24 WL155 AFT CARGO COMPARTMENT Z-ANGLE MANY AREAS OF CORROSION / REMOVED CORROSION ON AFT CARGO 2-ANGLE EH STA 727C+9 TO STA 767 IAW SRM 51-10-02-0G-0. MEASURED MATERIAL LOSS ORIGNIAL (TP .040' REMAINING (T) .031' LOSS OF .009' OUT OF LIMITS IASDR SWAA2020041334299Angle · corrodedFWD CARGO. STA 500I; RBL 23; WL 155; CURVED SIDEWALL BULKHEAD ANGLE HAS CORROSION ON UPPER SURFACE / REMOVED CORROSION NO SRM LIMITS GIVEN. REMOVED AND REPLACED FWD CARGO STA 500I RBL 23 CURVED SIDEWALL BULKHEAD ANGLE IAW B-737 SRM 51-40-02 AND DWGS 143A9481 RSDR SWAA2020041334298Angle · corrodedFWD CARGO. STA 500I; RBL 22 TO LBL 22; WL 155; FLOOR SUPPORT BULKHEAD ANGLE HAS CORROSION ON UPPER SURFACE. / REMOVED CORROSION FROM FWD CARGO STA 500I RBL 22 TO LBL22 WL155 FLOOR SUPPORT BULKHEAD ANGLE NO SRM REPAIR LIMITS GIVEN IAW B737 SRM 51-10-02-0G-0; RE
Back to Boeing 737-8H4