As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SUPPLEMENTAL INFORMATION: L.H W/W VAPOR BARRIER HAS A CRACK 6' IN LENGTH. C/W REPAIR PER SRM 57-10-10-1A-2 REPETITIVE ACTION REQUIRED DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FREQUENTLY. MAKE SURE THAT CRACK HAS NOT GROWN PAST THE INTERIM SEAL / A) REPETITIVE ACTION REQUIRED COMPLIED WITH; NO ADDITIONAL DAMAGE OR DETERIORATION NOTED. OK TO CONTINUE SERVICE IN ACCORDANCE WITH REFERENCE SRM 57-10-10-1A-2