SDR ASAA2026092969105Floor Support · corrodedAFT CARGO COMPARTMENT, FLOOR SUPPORT RAIL SPLICE HAS CORROSION ON UPPER SURFACE BETWEEN STA 727I & 727J AT RBL-8 . MARKED IN RED. GROUNDED - YES. REMOVED AND REPLACED FLOOR SUPPORT SPLICE RAIL IAW SRM 51-40-02 AND 51-40-05.Sep 29, 2026 · N915AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026092969104Floor Support · corrodedAFT CARGO COMPARTMENT, FLOOR SUPPORT RAIL SPLICE HAS CORROSION ON UPPER SURFACE BETWEEN BS 727I & 727J AT RBL-3 . GROUNDED - YES. REMOVED AND REPLACED FLOOR SUPPORT SPLICE RAIL IAW B737-MAX9 SRM 51-40-02 AND 51-40-05.Sep 29, 2026 · N915AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026092919996Toilet · leakingWATER RAN ALL OVER AFT GALLEY FLOOR DURING THE FLIGHT EVEN THOUGH WATER VALVE WAS OFF. REF TO ECRA 2011-01000 GALLEY SPILL, CARRIED OUT INITIAL CLEAN UP ON AFT GALLEY SPILL AREA AROUND R2 DOOR AS PER GALLEY SPILL PARA A. ECRA 2011-01000 TOILET REPLACED ON CASep 28, 2026 · N37516 · Boeing 7379 · Waste Disposal SystemSDR CALA2026092919972Unknown · odorAFT FA REPORTS SULPHURIC ODOR COMING FROM AROUND R2 DOOR, INSPECTED AFT SECTION OF ACFT AND GALLEY OVENS EVERYTHING LOOKS CLEAN AND NO ODORS NOTED, RAN PACKS. NO DEFECTS NOTED.Sep 28, 2026 · N37531 · Boeing 7379 · Air Distribution SystemSDR CALA2026093020021Girt Bar · looseAFT LEFT GIRT BAR FABRIC NOT STOWED, IAW FLT ATTENDANT. STOWED AND CHECKED THE GIRT BAR OPS. ALL NORMAL IAW AMM 25-66-01.Sep 27, 2026 · N17420 · Boeing 7379 · Emergency EquipmentSDR CALA2026092819951Floor Support · crackedCRACKED MID WET AREA FLOOR SUPPORT, BL 0, BS 500C - 500D. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 143A5410.Sep 27, 2026 · N37528 · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026092819947Battery Pack · no testL1 DOOR EMERGENCY EXIT LIGHTS WILL NOT TEST. REMOVED, & REPLACED THE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06.Sep 27, 2026 · N37516 · Boeing 7379 · Emergency LightingSDR CALA2026092819945Battery Pack · no testRIGHT OVERWING EMERGENCY EXIT LIGHTS WILL NOT TEST. REMOVED, & REPLACED THE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06.Sep 27, 2026 · N37516 · Boeing 7379 · Emergency LightingSDR CALA2026092819943Battery Pack · no testR2 DOOR EMERGENCY EXIT LIGHTS WILL NOT TEST. REMOVED, & REPLACED THE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06.Sep 27, 2026 · N37516 · Boeing 7379 · Emergency LightingSDR CALA2026092819941Battery Pack · no testLEFT OVERWING EMERGENCY EXIT LIGHTS WILL NOT TEST, M01694. REMOVED & REPLACED THE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06.Sep 27, 2026 · N37516 · Boeing 7379 · Emergency LightingSDR ASAA2026092668921Power Supply · inoperativeCUSTOMER WALK ITEM: R2 EMERGENCY LOWER DOOR LIGHT INOP. GROUNDED - YES. REMOVED AND REPLACED M01672 EMERGENCY POWER SUPPLY, S/N 173592. OPS CHECK GOOD, IAW B737 MAX AMM 33-51-06.Sep 26, 2026 · N919AK · Boeing 7379 · Emergency LightingSDR CALA2026092819896Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK M1673 HAS LOW CHARGE. REMOVED, REPLACED, AND OPS CHECKED GOOD THE EMER LIGHT BATTERY PACK M1673 IAW AMM 33-51-06.Sep 26, 2026 · N47517 · Boeing 7379 · Emergency LightingSDR CALA2026092819892Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M3379 FAILS TO TEST. REPLACED AND OPS CHECKED GOOD OF M3379 BATTERY PACK IAW AMM 33-51-06. OPS CHKD GOOD.Sep 26, 2026 · N47517 · Boeing 7379 · Emergency LightingSDR CALA2026092819890Lamp · inoperativeEXTERIOR EMERGENCY LIGHT NEAR L2 DOOR IS INOPERATIVE. REPLACED THE LAMPS IAW AMM 31-51-04. OPS CHECK GOOD IAW AMM 31-51-04.Sep 26, 2026 · N47517 · Boeing 7379 · Emergency LightingSDR CALA2026092919963Proximity Sensor · faultedINTERMITTENT LE FLAP EXT LIGHT AND OVHD FLAP 1 FULL XTND INDICATOR, SPEED CMD DROPS TO .63. ON ARRIVAL FSEU BITE FAULTED F1 PROX EXTEND SWITCH, MSG 27-81217. ON GND, RAN FLAPS A COUPLE OF TIMES, FULL DOWN & UP. ALL NORMAL. REMOVED AND REPLACED LE FLAP 1, ESep 25, 2026 · N37473 · Boeing 7379 · Trailing Flap Position Indicating SystemSDR CALA2026101520374Seat Track · corrodedMID WET AREA SEAT TRACK, LBL 24.75 CORRODED AT BS 500E. INSTALLED A NEW SEAT TRACK SECTION & SPLICE REPAIR, LBL 24.75 BTWN BS 500B-C - 500E-F IAW SRM 53-00- 52-2R-4, FIGURE 202, DETAIL A, & DWG 143A5300.Sep 24, 2026 · N37528 · Boeing 7379 · Fuselage, Seat/Cargo Attach FittingsSDR CALA2026101220289Skin · gougedFOUND A GOUGE AT CROWN UPPER FUSELAGE SKIN UNDER WIFI RADOME FAIRING FWD OF RT FWD CLEVIS STRINGER 3R, BS 727J. CROWN UPPER FUSELAGE SKIN WAS REPAIRED IAW ESR-WI 2024672-4-15777 AND EC/RA 5360-02214.Sep 24, 2026 · N37528 · Boeing 7379 · Fuselage Main, Plate/SkinSDR CALA2026092819850Flashlight Assy · faultedCOCKPIT EMERGENCY FLASHLIGHT INOP REMOVED AND REPLACED COCKPIT EMERGENCY FLASHLIGHT AS REQD OPS CHECK GOOD.Sep 24, 2026 · N17529 · Boeing 7379 · Emergency EquipmentSDR CALA2026092519830Battery Pack · inoperativeRIGHT OVERWING EXIT LIGHTS INOPERATIVE. M1695 BATTERY PACK REMOVED AND REPLACED, OPS CHECKED GOOD M1695 BATTERY PACK IAW AMM 31-51-06.Sep 24, 2026 · N47517 · Boeing 7379 · Emergency LightingSDR CALA2026092519828Battery Pack · inoperativeR2 DOOR EMERGENCY LIGHTS INOP. M1672 BATTERY PACK. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 31-51-06.Sep 24, 2026 · N47517 · Boeing 7379 · Emergency LightingSDR CALA2026092319690Light · detached22C EMERGENCY LIGHT STRIP PANEL FELL OFF. SECURED UNDERSEAT TRIM BOX THAT HOUSES AISLE PATH LIGHT. OK FOR SERVICE. REF AMM 33-51-11.Sep 22, 2026 · N47524 · Boeing 7379 · Emergency LightingSDR CALA2026092419778Power Supply · faultedCHRONIC EMERGENCY EXIT LIGHTS AT OVERWING EXIT AND SEAT 20 AND 21 D,E,F ILLUMINATING RANDOMLY. REMOVED AND REPLACED POWER SUPPLY & BATTERY PACK IAW AMM 33-51-06. OPS CHECKED GOOD.Sep 21, 2026 · N47512 · Boeing 7379 · Emergency LightingSDR CALA2026092219637Power Supply · inoperativeFIRST CLASS EMERGENCY LIGHTS INOPERATIVE, ALL SEATS. REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK JUST AFT OF CONTROL CABIN DOOR IAW MM 33-51-06-960-802. OPS CHKD GOOD.Sep 21, 2026 · N37542 · Boeing 7379 · Emergency LightingSDR CALA2026092219636Battery Pack · inoperativeL1 DOOR EMERGENCY LIGHT INOPERATIVE. REPLACED POWER SUPPLY & BATTERY, OPS AND TESTED GOOD IAW AMM 33-51-06.Sep 21, 2026 · N37510 · Boeing 7379 · Emergency LightingSDR CALA2026092219654Power Supply · inoperativeR2 DOOR EMERGENCY LIGHTS INOPERATIVE. REPLACED THE POWER SUPPLY (M1672) IAW AMM 33-51-06 -960-803. OP CHECKED GOOD.Sep 19, 2026 · N27509 · Boeing 7379 · Emergency LightingSDR CALA2026092219650Battery Pack · no testEMERGENCY LIGHTS OPS CHKD, M1671 AND M3379 BATTERY PACKS INOPERATIVE. REPLACED THE BATTERY PACKS ON M1671 AND M3379 IAW AMM 33-51-06-960-802. OPS CHECK GOOD.Sep 19, 2026 · N47512 · Boeing 7379 · Emergency LightingSDR CALA2026092119565Light Sys · faultedEMERGENCY EXIT LIGHTS MOMENTARILY CAME ON OVER ALL FOUR OVERWING EXITS RIGHT BEFORE TAKEOFF ROLL. LIGHTS WENT OUT ON THEIR OWN. EMER EXIT LIGHT SWITCH TESTED GOOD. F/A VERIFIED ONLY RT OVERWING EMERG AND SURROUNDING LIGHTS CAME ON. ACCESSSED M1695 AND VERIFIEDSep 19, 2026 · N47512 · Boeing 7379 · Emergency LightingSDR CALA2026092119556Potable Water · contaminatedWATER FROM REAR COFFEE MACHINE SMELLS AND TASTES BAD. DRAINED AND REFILLED POTABLE WATER SYSTEM IN REF TO AMM 12-14-00. OPS CHECK BOTH REAR COFFEE MAKERS IN THE REAR OF THE AIRCRAFT IN REF TO AMM 25-32-01. THE WATER NO LONGER SMELLS.Sep 19, 2026 · N17574 · Boeing 7379 · Potable Water SystemSDR CALA2026092119555Potable Water · contaminatedBAD ODOR AND TASTE COMING FROM POTABLE WATER. DRAINED POTABLE WATER TANK AND REFILLED TANK, ALSO PURGED ALL FACETS AND COFFEE MAKERS, ODOR AND SMELL IS GONE. REF FIM 38-10 TASK 803.Sep 18, 2026 · N37555 · Boeing 7379 · Potable Water SystemSDR CALA2026092819916Shade · brokenDURING CABIN CHECK, FOUND WINDOW SHADES BROKEN AT SEATS 20A, 21A. APPLIED TAPE AND SECURED AFFECTED WINDOW SHADES IN THE FULL OPEN POSITION. WINDOW SHADES DO NOT POSE ANY HAZARD TO PASSENGERS OR CREW. STICKER APPLIED ON FWD ATTENDANTS PANEL.Sep 17, 2026 · N37531 · Boeing 7379 · Passenger Compartment EquipmentSDR CALA2026091719493Unknown · odorACRID OILY ODOR IN A/C AIR FOLLOWING HYDRAULIC SERVICING W/BOTH PACKS RUNNING OFF APU BLEED. ACP TASK FIM 21-00-830 SMOKE OR FUMES IN CABIN SOURCE UNKNOWN. RAN BOTH ENGINES FOR 5 MINUTES RAN BOTH PACKS AND VERIFIED NO ODOR IN FLT DECK AND WALKED THROUGH CABINSep 16, 2026 · N17431 · Boeing 7379 · Air Distribution SystemSDR ASAA2026091468746Light · inoperativeEMERGENCY SLIDE LIGHT AT L2 DOOR INOP. GROUNDED - YES. REMOVED AND REPLACED L2 DOOR EMERGENCY SLIDE LIGHT IAW AMM 33-51-04. OPS CHECKED GOOD.Sep 14, 2026 · N938AK · Boeing 7379 · Emergency LightingSDR CALA2026091619472Elec Connector · dirtyEMERGENCY AISLE LIGHTS INOPERATIVE AT SEAT 5AB. CLEANED CONNECTOR UNDERNEATH SEAT 5A. OPS CHECK GOODSep 14, 2026 · N37473 · Boeing 7379 · Light System WiringSDR CALA2026091419396Power Supply · inoperativeFIRST CLASS EMERGENCY EXIT PATH LIGHTS INOP. REMOVED AND REPLACED FORWARD EMERGENCY EXIT POWER SUPPLY PER AMM 33-51-06-960-803. OPS CHECK GOODSep 13, 2026 · N37542 · Boeing 7379 · Emergency LightingSDR CALA2026091519425Drain Valve · leakingSUSPECTED LEAK NEAR AFT LAV ACCOMPLISHED STEP 1, IMMEDIATE CLEANUP REQUIRES STEP 2 IN DEPTH CLEAN UP WITHIN 7 DAYS UPON INSPECTION, FOUND MASSIVE WATER PUDDLE BETWEEN LAVS IN THE AFT. FOUND LEAK BEHIND TOILET SHROUD IN LAV D. LEAK COMING FROM DRAIN VALVE. SHUTSep 12, 2026 · N37555 · Boeing 7379 · Waste Disposal SystemSDR CALA2026091519422Selector · faultedALL 3 MLG WOULD NOT RETRACT AFTER TAKEOFF. 3 GREEN, 3 RED. CREW REPORTED ALL 3 MLG FAILED TO RETRACT AS COMMANDED. 3 RED & 3 GREEN MLG INDICATION LIGHTS REMAINED ILLUMINATED THROUGHOUT FLT WITH MLG DOWN. ATTEMPTED RESET USING ALTERNATE MANUAL EXTENSION DOORSep 12, 2026 · N77575 · Boeing 7379 · Landing Gear Retraction/Extension SystemSDR ASAA2026091168686Cover · crackedFLOOR PHOTOLUMINESCENT STRIP COVER SLEEVE CRACKED AND PEELING UP. (A SECTION APPROX 20 INCHES IN LENGTH) LOCATED OUTBOARD AND FWD OF SEAT 1C. GROUNDED - YES. REMOVED AND REPLACED DAMAGED FLOOR PHOTOLUMINESCENT STRIP PER AMM 33-51-15-960-801.Sep 11, 2026 · N979AK · Boeing 7379 · Emergency LightingSDR CALA2026091419391Light · brokenEMERGENY LIGHT IN AISLE SEAT 14C BROKEN. REMOVED AND REPLACED EMERGENCY LIGHT AT 14C IAW AMM 33-51-11.Sep 11, 2026 · N37504 · Boeing 7379 · Emergency LightingSDR CALA2026091419384Unknown · odorSTRONG ODOR OF FUEL IN CABIN AFTER STARTING ENGINES. ACCOMPLISHED INITIAL EVALUATION REF FIM 21-00 TASK 830 CONDITIONAL INSP. PERFORMED CREW ASSISTED WITH BOTH ENGINE START AMM 21-00-00 COULD NOT DUPLICATE ODOR ENGINE RUN OK. BOTH PACKS OPERATE NORMAL NO SMSep 11, 2026 · N37554 · Boeing 7379 · Air Distribution SystemSDR ASAA2026090968864Transition Panel · corrodedFWD PIT R/H TRANSITION PANEL IS CORRODED OUT OF LIMITS BETWEEN STA 500K AND 500L. GROUNDED - YES. REPAIRED THE FWD PIT R/H TRANSITION PANEL FROM STA 500K TO 500L USING PN:BAC1496-444 7075-T6 IAW B737-MAX9 SRM 53-00-53-2R-5.Sep 9, 2026 · N919AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026090968848Support Angle · corrodedFWD CARGO, AFT LOWER BULKHEAD SUPPORT WAS CORRODED. GROUNDED - YES. REMOVED AND REPLACED THE SUPPORT ANGLE IAW SRM 51-40-02, UPON FURTHER EVALUATION NO ALLOWABLE DAMAGE LIMITS GIVEN IN THE SRM.Sep 9, 2026 · N919AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026090968847Transition Panel · corrodedAFT CARGO RT TRANSITION PANEL HAS MANY SPOTS OF CORROSION AT BS 727I+8 - 767. GROUNDED - YES. REMOVED CORROSION FROM AFT CARGO TRANSITION PANEL IAW SRM 53-00-53-1A-2. ORIG MATERIAL WAS .040" IAW SRM 53-60-53-01-2. REMOVED .006", REMAINING IS .034" FOUND TO Sep 9, 2026 · N919AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026090968846Transition Panel · corrodedAFT CARGO RT TRNASITION PANEL HAS MANY SPOTS OF CORROSION AT BS 727G+12 TO 727I+6. GROUNDED - YES. REMOVED CORROSION FROM AFT CARGO RT TRANSITION PANEL BS 727G+12 - 727I+6 IAW SRM 53-00-53-1A-2, ORIG MAT WAS .040" IAW SRM 53-60-53-01-2, REMOVED .008", REMAINSep 9, 2026 · N919AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026090968845Transition Panel · corrodedFWD CARGO BAY, LT TRANSITION PANEL IS CORRODED OUT OF LIMITS BTWN BS 500D - 500F+4. GROUNDED - YES. REPAIRED FWD CARGO BAY, LT TRANSITION PANEL BETWEEN STA 500D AND 500F+4 IAW SRM 53-00-53-2R-5.Sep 9, 2026 · N919AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026091019357Skin · dentedRT WING SLAT NR 6 DENTED OUT OF LIMITS. ACCOMPLISHED REPAIR AT RT WING SLAT #6 PER SRM 57-42-01-2R-1 REPAIR 1 PARAGRAPH 4.0 TABLE 201 FIG. 202.Sep 9, 2026 · N37530 · Boeing 7379 · Leading Edge DevicesSDR CALA2026090919339Sump · leakingWHILE SHUTDOWN AT GATE NR 1 ENGINE HAS MIST COMING FROM ENGINE I NLET AND SMELLS OF HYDRAULIC. ENGINE RUN CHECKLIST UPLOADED RAN NR 1 ENG AT IDLE IAW AMM 71-71-00-200-801-G00, FOUND B-SUMP DRAIN LEAKING 10 DROPS PER MINUTE (300CC). IAW AMM 71-71-00-200-801-G0Sep 8, 2026 · N37538 · Boeing 7379 · Hydraulic Power SystemSDR CALA2026090919325Skin · wornRIGHT WING INBD FIXED LEADING EDGE SKIN PANEL 611A IS WORN ON INBD SIDE OF NR 2 PYLON. REMOVED AND REPLACED RT WING INBD FIXED LEADING EDGE SKIN PANEL 611A IAW SRM 51-40-02 AND DWG 116A4412, REV-.Sep 8, 2026 · N47517 · Boeing 7379 · Wing, Plate/SkinSDR CALA2026090819314Light · detachedEMERGENCY EXIT LIGHT UNDER 30 ABC BROKEN OFF. REMOVED AND REPLACED 30ABC FLOOD IGHT AT SEAT ASSY. REF CMM 25-21-68-45-46. OPERATIONAL CHECK PROVES GOOD.Sep 8, 2026 · N47569 · Boeing 7379 · Emergency LightingSDR CALA2026090719271None · noneON TAXI IN, LT ENG. AFTER SHUTDOWN SWITCH TO APU AIR. STRONG FUEL ODOR FROM PACK. INSPECTED & FOUND THAT THE STRONG ODOR WAS FROM PREVIOUS NIGHT FUEL SPILL ON THE GROUND, OKAY FOR FLIGHTSep 6, 2026 · N37549 · Boeing 7379 · Standard Practices/StructuresSDR CALA2026090819310Oven · odorFWD GAL OVENS EMMITING ELEC SMELL. OVENS WILL REMAIN OFF REMAI NDER OF FLT. FWD GALLEY PERFORMED FWD GALLEY OVENS CLEANING REF AMM 25-32-03-100-801. NO BAD SMELL AT THIS TIME.Sep 6, 2026 · N77582 · Boeing 7379 · Buffet/Galleys
Back to Boeing 737-9