SDR CALA2026090719277Lamp · inoperativeEMERGENCY LIGHTS OPS CHECK, AFT LT EMERGENCY SLIDE LIGHT INOPERATIVE. RELAMPED AFT LT EMERGENCY SLIDE LIGHT IAW AMM 33-51-04-960-801, OPS CHKD GOOD.Sep 5, 2026 · N77558 · Boeing 7379 · Emergency LightingSDR CALA2026090719269Oven · inoperativeRIGHT FORWARD OVEN NOT HEATING AND HAS BURNING ODOR, NO SMOKE. WILL NOT USE. PERFORMED FWD GALLEY RT OVEN OPS TEST IAW AMM 25-32-03. OVEN WORKING NORMALLY. NO BURNING ODOR. OK FOR SERVICE.Sep 5, 2026 · N37554 · Boeing 7379 · Buffet/GalleysSDR CALA2026090719278Light · inoperativeRIGHT AFT SLIDE EMERGENCY LIGHT INOPERATIVE. REPLACED RT AFT SLIDE EMERGENCY LIGHT IAW AMM 33-51-04-960-801, OPS CHKD GOOD.Sep 4, 2026 · N17565 · Boeing 7379 · Emergency LightingSDR CALA2026090419240Fuse · blownEMERGENCY LIGHTS OPS CHK, LIGHTS INOPERATIVE ROW 1-5. PART NIS TPA ALSO NEED BATTERY AS A PRECAUTION. PART NIS TPA ALSO NEED BATTERY AS A PRECAUTION. PART NIS TPA INSTALLED MULTIPLE, VERIFIED FUNCTIONAL UNITS. NO HELP. TROUBLESHOT EMERGENCY LIGHT SYSTEM IN Sep 3, 2026 · N37507 · Boeing 7379 · Emergency LightingSDR CALA2026090419248Crossbeam · crackedCENTER SECTION UPPER CROSSBEAM AT BS 540 BL0 T CRACKED. REMOVED AND REPLACED NEW CROSSBEAM IAW B737-9 SRM 51-40-02, 51-40-05 , DWG 143A5240 REV-.Sep 2, 2026 · N37516 · Boeing 7379 · Fuselage Main, StructureSDR CALA2026090319227Battery Pack · inoperativeALL FIRST CLASS SEATS FLOOR PROXIMITY EMERGENCY LIGHTS INOP. REPLACE POWER SUPPLY- BATTERY PACK M1675 IAW AMM 33-51-06-960-802. ALL FIRST CLASS SEAT FLOOR PROXIMITY EMERGENCY LIGHTS OPS CHECKS GOOD.Sep 2, 2026 · N37507 · Boeing 7379 · Emergency LightingSDR CALA2026091519455Antenna · damagedBIRD STRIKE ON CLIMBOUT APROX 3000 FT PERFORMED INITIAL EVALUATION IAW AMM TASK 05-51-18. FOUND EXTERNAL DAMAGE IN NOSE RADOME AND FUSELAGE SKIN IN SECTION 41 BETWEEN FUS STA 130 AND FUS STA 178. PERFORMED BIRD STRIKE AND IN-FLIGHT HAIL STRIKE CONDITIONAL INSSep 1, 2026 · N27404 · Boeing 7379 · Localizer/VOR SystemSDR CALA2026090419232Battery Pack · inoperativeEMERGENCY LIGHTS INOP ON ALL FIRST-CLASS SEATS. REPLACED POWER SUPPLY AND BATTERY IAW AMM 33-51-06. OPS CHECK GOOD.Sep 1, 2026 · N37542 · Boeing 7379 · Emergency LightingSDR CALA2026083119055Light · illuminatedFWD ENTRY DOOR LIGHT ON TO COMPLIED WITH FIM 52-20 TASK 801. NO ACTIVE MESSAGES, FAULT IS INTERMITTENT. OPS CHECK GOOD AT THIS TIME.Aug 30, 2026 · N47470 · Boeing 7379 · Emergency LightingSDR CALA2026083119070Door · openHIGH FREQUENCY VIBRATION HEARD & FELT ON FLIGHT DECK & FWD LAV. FOUND EXTERNAL POWER DOOR OPEN UPON ARRIVAL. INSPECTED EXTERNAL POWER DOOR AND SURROUNDING AREA. NO DEFECTS NOTED. VERIFIED EXTERNAL POWER DOOR CLOSES AND SECURES PROPERLY IAW AMM 52-49-02-40Aug 29, 2026 · N77552 · Boeing 7379 · Accessory Compartment DoorsSDR CALA2026090119170Oven · fumesFWD GALLEY OVEN (205) REQUIRES REPLACEMENT DO TO FUMES. REMOVED FWD GALLEY OVEN 205. INSPECTED AREA, ELEC CONNECTIONS, AAC CLEANED ANY DIRT, GRIM, & DEBRIS. INSTALLED NEW OVEN IAW AMM 25-32-03/501. OVEN IS BAD FROM STOCK. WILL NOT STAY ON, TRYED SWITCHED Aug 28, 2026 · N17599 · Boeing 7379 · Buffet/GalleysSDR CALA2026083119116Oven · odorACFT REQUIRES SMOKE ODOR INSPECTION IAW AMM 05-51-56-200-801. PERFORMED SMOKE ODOR INSPECTION IAW AMM 05-51-56-200-801 AND FOLLOWED FIM 21-00 TASK 830. PERFORMED VISUAL INSPECTION OF LT & RT A/C PACKS, NO DEFECTS NOTED. C/W APU ON & USING APU BLEED ON, RAAug 28, 2026 · N17599 · Boeing 7379 · Buffet/GalleysSDR CALA2026083119041Unknown · odorBURNING ODOR IN FLIGHT DECK DURING CLIMB, LASTED 2 MINS. F/A'S DID NOT SMELL ANYTHING. PIREP OVENS ONLY USED IN CRUISE AFTER ODOR EVENT. NO VISIBLE SMOKE PRESENT. ODOR ONLY REPORTED FROM COCKPIT CREW. HYDRAULIC SYS WAS SERVICED CORRECTLY. RAN APU & DID NAug 28, 2026 · N17599 · Boeing 7379 · Air Distribution SystemSDR CALA2026083119060Power Supply · faultedEMERGENCY LIGHTS AT ROWS 8-14, MID LAV EMERGENCY LIGHTS, ROW 2 CEILING AND LEFT FWD EXTERIOR OVERWING EMERGENCY LIGHTS COME ON AND OFF WITH EMERGENCY LITE SWITCHES OFF. OCCURRED 3 TIMES AND HAS HISTORY. T/S IAW FIM 33-51 T 815, WDM 33-51-12-4, FOUND POWER SUPAug 27, 2026 · N37506 · Boeing 7379 · Emergency LightingSDR CALA2026083119031Oven · odorINTERMITTENT FAINT BURNING PLASTIC ODOR IN FLT DECK & CABIN. THROUGHOUT FLT LASTING 1 MIN FAINT BURNING ODOR IN COCKPIT. ODOR PRESENT AT HIGH POWER SETTINGS, SUGGEST TAKING ACFT TO THE RUN-UP PAD TO ISOLATE ODOR. APU WAS OFF WHEN ODOR WAS PRESENT. OPS PACKSAug 26, 2026 · N17599 · Boeing 7379 · Buffet/GalleysSDR CALA2026083119027Oven · faultyFOUL ODOR FROM RT SIDE FLT DECK THRU FWD GALLEY & ENDS AFT 1ST CLASS, FOUND FOUL ODOR COMING FROM OVEN 205 FWD GALLEY. R & R FWD GALLEY OVEN 205. IAW AMM 25-32-03-400-804. NO ODORS. OPS CHKD OK.Aug 26, 2026 · N17420 · Boeing 7379 · Buffet/GalleysSDR CALA2026082618931Unknown · odorSMOKE ODOR CONDITIONAL INSPECTION, REQUIRED IAW AMM 05-51-XX, DUE TO AN INCIDENT REPORTED BY THE CREW.FA REPORTED ODOR DURING CLIMB THAT DISSIPATED ODOR RETURNED ON DESCENT. RAN PACKS FULL HOT 3 X BURN OUT. WALKED UP AND DOWN CABIN. NO OILY PETROLEUM SMELL NOAug 26, 2026 · N17599 · Boeing 7379 · Air Distribution SystemSDR CALA2026090219192Strap · corrodedCORROSION IN MULTIPLE LOCATIONS ON THE LT TRANSITION STRAP IN THE AFT PIT BETWEEN BS 727G & 787. REMOVED DAMAGED AREA ON TRANSITION STRAP AT STA 727G AND 787. ACCOMPLISHED REPAIR PER B737 MAX SRM 53-00-53-2R-5 REPAIR 5.Aug 25, 2026 · N47517 · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026082518917Transition Panel · puncturedTRANSITION PANEL BETWEEN STA 727F AND 727E LT SIDE IS PUNCTURED. REMOVED DAMAGE ON TRANSITION PANEL AT 727F AND 727E. ACCOMPLISHED REPAIR IAW SRM 53-00-53-2R-5, REPAIR 5.Aug 25, 2026 · N47517 · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026082518872Lamp · inoperativeDOOR L2 EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-04.Aug 24, 2026 · N37551 · Boeing 7379 · Emergency LightingSDR CALA2026082418822Wire · brokenEMERGENCY LIGHTS OPERATIONAL CHECK, LT ROW 36 AISLE PATH LIGHTING INOP. FOUND BROKEN WIRE ON AISLE PATH LIGHT ASSY, REMOVED AND REPLACED LIGHT ASSY, OPS CHECKED GOOD AMM 33-51-00.Aug 22, 2026 · N37525 · Boeing 7379 · Light System WiringSDR CALA2026082318808Unknown · noneOFF THE GATE FLIGHT CREW REPORTS THAT A PASSENGER SMELLED FUEL. PERFORMED SMOKE OR FUMES IN CABIN IAW AMM 05-51-56-280-001. FLIGHT ATTENDANTS ALL REPORT OF NO ODOR IN THE CABIN AND MTX DID NOT NOTICED ANY ODOR PERFORMED SMOKE OR FUMES IN CABIN IAW AMM 05-51-56Aug 21, 2026 · N27515 · Boeing 7379 · Air Distribution SystemSDR ASAA2026081968119Battery Pack · inoperativeAFT EMERGENCY LIGHT INOP. GROUNDED - YES. REPLACED BOTH AFT BATTERY PACKS IAW AMM 33-51-06 OPS CHECK GOOD NO FAULT AT THIS TIME.Aug 19, 2026 · N964AK · Boeing 7379 · Emergency LightingSDR ASAA2026081968110Bulb · burned outR/H AFT OVERWING EXIT EXTERIOR EMERGENCY LIGHT IS INOP. ODR REQUIRED. GROUNDED - YES. RELAMPED AND OP CHECKED R/H AFT OVERWING EXTERIOR EMERGENCY LIGHT IAW AMM 33-51-04-960-801. NEW LIGHT OP CHECKS GOOD.Aug 19, 2026 · N709AL · Boeing 7379 · Emergency LightingSDR CALA2026081918732Smoke Detector · false activationSMOKE DETECTOR WENT OFF IN THE MID LAVATORY WHEN A PASSENGER WAS IN THERE. NO EVIDENCE OF SMOKE OR FIRE. INSPECTED LAV T AND SMOKE DETECTOR, NO SMELL OR DEFECTS NOTED. SMOKE ALARM PASSED SELF TEST AND SMOKE TEST REF AMM 26-14-00.Aug 18, 2026 · N57466 · Boeing 7379 · Smoke DetectionSDR CALA2026081718684Power Supply · inoperativeIN SEAT EMERGENCY LIGHTS IN FIRST CLASS, INOPERATIVE. R & R FWD EMERGENCY LIGHT POWER SUPPLY. OPS CHKD GOOD IAW AMM 33-51-06.Aug 16, 2026 · N37532 · Boeing 7379 · Emergency LightingSDR CALA2026081918735Power Supply · inoperativeOVERHEAD AISLE EMERGENCY LIGHT 10DEF INOPERATIVE. VERIFIED SURROUNDING AISLE LIGHTS OPERATIVE. MEL 3351A APPROVED. C/W MEL REPLACED EMERGENCY AISLE LIGHT ASSY AT ROW DEF. IAW AMM 33-51-03-960-801. NO HELP. LIGHT STILL INOPERATIVE. REPLACED POWER SUPPLY M1Aug 15, 2026 · N37506 · Boeing 7379 · Emergency LightingSDR CALA2026081818709Floorbeam · corrodedAFT WET AREA FLOOR BEAM WITH CORROSION AREA AROUND HARD POINT FITTING BS 947 LBL 50. INSTALLED REPAIR ON STA 947.5 TRANSVERSE FLOOR BEAM UPPER CHORD IN ACCORDANCE WITH SRM 53-70-51-2R-5, AAR-MIA ESR-WI NO.: 2024492-4-15612 REV. IR, AND UNITED EC/RA 5370-01250 Aug 15, 2026 · N37518 · Boeing 7379 · Fuselage Main, Floor BeamSDR ASAA2026081568004Light Sys · intermittentFA REPORTS AFT EMERGENCY LIGHTS RANDOMLY TURNED ON WITHOUT BEING ACTIVATED. GROUNDED - YES. PERFORMED IFIM 33-51-00-810-817 OPS TEST PASS, COULD NOT DUPLICATE DEFECT,NO HISTORY 30 DAYS.Aug 15, 2026 · N912AK · Boeing 7379 · Emergency LightingSDR CALA2026081718683Power Supply · inoperativeEMERGENCY LIGHTS FROM ROW 28 TO 34 INOP. REMOVED AND REPLACED POWER SUPPLY FOR M3378 IAW AMM 33-51-06-960-803. OPERATIONAL CHECK GOOD.Aug 15, 2026 · N17566 · Boeing 7379 · Emergency LightingSDR CALA2026081718676Floor Support · corrodedCORROSION ON AFT WET AREA FLOOR SUPPORT, BS 947 - 967, WITH CORRODED AREA AROUND HARD POINT FITTING, RBL 50. R & R FLOOR SUPPORT BETWEEN BS 947 - 967, RBL 50 IAW SRM 51-40-02-0G-0 & DWG 147A5650.Aug 15, 2026 · N37518 · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026081718674Unknown · odorFLIGHT CREW REPORTED FLIGHT ATTENDANTS AT THE BACK OF THE AIRPLANE ODOR FUMES IN THE CABIN DURING TAKEOFF. COMPLETED CONDITIONAL INSP IAW AMM 05-51-56. ACCORDING TO CONFIG REPORT FORM 46-6020, NO ODORS DETECTED AT THIS TIME. OK FOR SERVICE.Aug 14, 2026 · N37551 · Boeing 7379 · Air Distribution SystemSDR CALA2026081718654Light · faultedALL FIRST CLASS EEPL WILL NOT ILLUMINATE REPLACED FUSES NO HELP. TRACED WIRES REF WDM 33-51-21. GOOD CONTINUITY THROUGHOUT CIRCUIT. INSPECTED ALL WIRES ALONG FLOOR IN FIRST CLASS, NO BREAKS OR DAMAGED WITING. SHOOK BUNDLES AND RECONNECTED ALL CONNECTORS. OPS CAug 14, 2026 · N37507 · Boeing 7379 · Emergency LightingSDR CALA2026081418641Filter · odorELECTRICAL BURNING ODOR FROM AFT GALLEY. PERFORMED FIM 21-00, TASK 830, STEP I. ELECTRICAL FAULTS PROCEDURE UNTIL STEP 1A. STARTED APU. TURNED ON ALL OVENS & COFFEE MAKERS IN AFT GALLEY OPENED AFT GALLEY CEILING EMERGENCY EXIT SIGN PANEL, FOUND NO DEFECTSAug 14, 2026 · N77576 · Boeing 7379 · Air Distribution SystemSDR CALA2026081718680Light · intermittentEMERGENCY LIGHTS PUSH TO TEST LIGHT DOES NOT ILLUMINATE WHEN PUSHED. ALL EMERGGENCY LIGHTS OPS NORMAL. AFT FA PANEL EMERGENCY LIGHT BUTTON ILLUMINATES WHEN PRESSED. UNABLE TO DUPLICATE FAULT.Aug 13, 2026 · N37504 · Boeing 7379 · Emergency LightingSDR ASAA2026081168263Angle · corrodedAFT CARGO RT LOWER FRAME BS 727L AT TRANSITION PANEL CORRODED AT NUTPLATE. GROUNDED - YES. REMOVED CORROSION FROM THE AFT PIT R/H LOWER FRAME LINER BRACKET AT STA 727L STR 25R IAW B737-9 SRM 53-00-07-1A-1.2.B. ORIG THICKNESS IS .063" IAW B737-9 SRM 53-60-07-01Aug 11, 2026 · N913AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026081168187Transition Panel · corrodedAFT CARGO RT TRANSITION PANEL CORRODED FROM BS 727+4 TO STA 727I+8. GROUNDED - YES. REMOVED CORROSION FROM THE AFT PIT RT TRANSITION PANEL AT BS 727+4 - 727I+8 IAW SRM 53-00-53-1A-2.2. ORIG. THICKNESS IS .040" IAW SRM 53-30-53-01-2, TABLE 2. REMOVED .008", REMAug 11, 2026 · N913AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026081168186Transition Panel · corrodedAFT CARGO RT TRANSITION PANEL CORRODED FROM BS 727I+8 - 767. GROUNDED - YES. REMOVED CORROSION FROM THE AFT PIT RT TRANSITION PANEL AT BS 727I+8 - 767 IAW SRM 53-00-53-1A-2.2. ORIG THICKNESS IS .040" IAW SRM 53-30-53-01-2 TABLED. REMOVED .009", REMAINING THICKAug 11, 2026 · N913AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026081168185Transition Panel · corrodedAFT CARGO LT TRANSITION PANEL CORRODED FROM BS 727I+8 TO 847. GROUNDED - YES. REMOVED CORROSION FROM AFT PIT LT SIDE TRANSITION PANEL FROM BS 727I+8 - 847 IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL WAS .040 IAW SRM 53-00-53-01-2, REMOVED .009 REMAINING .031 FOUNAug 11, 2026 · N913AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026081168184Transition Panel · corrodedAFT CARGO LT TRANSITION PANEL CORRODED FROM STA 727+4 TO 727I+8. GROUNDED - YES. REMOVED CORROSION FROM AFT PIT L/H SIDE TRANSITION PANEL FROM BS 727+4 TO 727I+8 IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL WAS .040 IAW SRM 53-00-53-01-2, 100% MATERIAL LOSS FOUNDAug 11, 2026 · N913AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR ASAA2026081067916Battery Pack · failedAFT LEFT EMERGENCY LIGHT FAILED FUNCTIONAL CHECK. GROUNDED - YES. REPLACED M1673 BATTERY POWER SUPPLY REF BOEING AMM TASK 33-51-06-960-802. OP TEST GOOD WITH AFT LEFT EMERGENCY LIGHTS ILLUMINATING AS REQUIRED. NO FURTHER DEFECTS.Aug 10, 2026 · N920AK · Boeing 7379 · Emergency LightingSDR CALA2026081718686Target · out of adjustALERTING {52-71003} PSEU AFT ENTRY DOOR SWITCH SENSOR IS TARGET FAR IN AIR, FAULTING 5 OF 10 LEGS. AS PRECAUTION. CARRIED BY ELB PERFORMED FIM 52-10, TASK 802, FOUND SENSOR TARGET FOR AFT ENTRY IN MARG POSITION, ADJUSTED THE SENSOR IAW AMM 52-71-11. OPS Aug 9, 2026 · N77573 · Boeing 7379 · Passenger/Crew DoorsSDR CALA2026081318572Structure · odorSMOKE ODOR CONDITIONAL INSP REQUIRED IAW AMM 05-51-XX DUE TO AN INCIDENT REPORTED BY THE CREW. FLT ATTENDANTS REPORTED ODOR ON CLIMB & DESCENT. NEW ACFT ODOR. DEBRIEFED FLT ATTENDANTS REGARDING ODOR. THE ODOR OBSERVED BY THE FLT ATTENDANTS AS CHEMICAL IN NAug 9, 2026 · N17468 · Boeing 7379 · Cabin Equipment/FurnishingsSDR ASAA2026080867883Lamp · inoperativeROW 17ABC LOWER EMERGENCY EXIT LIGHT ASSY HAS BULBS INOP. GROUNDED - YES. RELAMPED 17ABC LWR EMERY EXIT LIGHT ASSY, OPS CHECK GOOD REF B737 AMM 33-51-04.Aug 8, 2026 · N921AK · Boeing 7379 · Emergency LightingSDR CALA2026080918419Unknown · odorFAS REPORT STRONG RUBBER BURNING ODOR AFT ACFT RT. PER CREW, ODOR OCCURRED JUST AFTER TAKEOFF AND DISSIPATED QUICKLY. DID NOT SMELL ANYTHING FOR THE REMAINDER OF THE FLIGHT. INSPECTED ACFT & FOUND NO FAULTS. SUSPECT ODOR CAME FROM OUTSIDE ACFT. ACFT OK FAug 8, 2026 · N17413 · Boeing 7379 · Air Distribution SystemSDR ASAA2026080768183Support Angle · corrodedFWD CARGO AFT BULKHEAD LOWER SUPPORT HAS CORROSION. GROUNDED - YES. UPON FURTHER EVAL OF FWD PIT LOWER BULKHEAD SUPPORT FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS GIVEN IN BOEING B737-9 SRM. REMOVED AND REPLACED FWD CARGO LOWER BULKHEAD SUPPORT IAW SRM 51-40-0Aug 7, 2026 · N913AK · Boeing 7379 · Fuselage Miscellaneous StructureSDR CALA2026080918420Unknown · odorPILOT REPORT STRONG ODOR & LIGHT SMOKE OCCURED IN FLT DECK WITH PACKS RUNNING, HYDS ON. NARROWED DOWN TO EVENT HAPPENED WHEN ONLY NR 2 PACK ON. AFT CABIN, FLT ATTEND REPORTED SMOKE & STRONG ODOR COMING FROM CEILING DURING EVENT. TURNED HYDS OFF & PACK 2 OFF,Aug 7, 2026 · N77543 · Boeing 7379 · Air Distribution SystemSDR CALA2026080918417Unknown · odorELECTRIC BURNING ODOR FROM CABIN DURING TAXI. RETURN TO GATE. MET WITH FLIGHT CREW AFTER RETURN TO GATE SPOKE WITH THE CAPTAIN AND SAID EVERYTHING WAS GOING OK WITH ONLY RT ENG RUNNING THEN HEAVY RAIN STARTED TO FALL AND THEN THE ODOR CAME INTO THE CABIN. NAug 7, 2026 · N37510 · Boeing 7379 · Air Distribution SystemSDR CALA2026080918384Battery Pack · inoperativeEMERGENCY LIGHTS OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - 29D EMERGENCY CEILING LIGHT INOP. REMOVED AND REPLACED BATTERY PACK M3379 IN REFERENCE WITH AMM 33-51-06-960-802. OPS CHECK NORMAL AT THIS TIME.Aug 7, 2026 · N37513 · Boeing 7379 · Emergency LightingSDR CALA2026080918382Lamp · inoperativeEMERGENCY LIGHTS OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - FWD DOOR 1 EXIT LIGHT ASSY. OVER DOOR ONE LIGHT INOP. REPLACED ONE LAMP IN REFERENCE WITH AMM 33-51-01-960-801. OPS CHECK NORMAL AT THIS TIME. ONE LAMP REPLACED WITHIN ASSEMBLY. OPS CKD OKAug 7, 2026 · N37513 · Boeing 7379 · Emergency Lighting
Back to Boeing 737-9