SDR ASAA2018032624044Roller · bindingCREW REPORTED THE R2 DOOR DID NOT FULLY CLOSE. ACFT GROUNDED. FOUND THE UPPER HINGE ROLLERS JAMMED OVER DOOR CLOSED SWITCH. FREED THE DOOR. NO DEFECTS OR DAMAGE NOTED AMM 52-41-00. ACFT GOOD FOR SERVICE.SDR ASAA2018031424005Stringer Clip · crackedFWD CARGO BAY FRAME, BS 500A HAS A CRACKED STRINGER CLIP 21L. ACFT GROUNDED. REMOVED AND REPLACED THE STRINGER CLIP IAW SRM 51-40-02-0G-0, ITEM D PAGE 6.SDR ASAA2018031424004Support · corrodedAFT WET AREA GALLEY GUTTER BS 990, LBL 36 TO LBL 48 IS CORRODED. ACFT GROUNDED. REMOVED AND REPLACED THE GALLEY GUTTER IAW SRM 51-40-02-0G.SDR ASAA2018031324203Cargo Track · crackedAFT CARGO PIT FLOOR TRACK SUPPORT IS CRACKED IN RADIUS ABOVE ATTACH POINTS AT RBL 16 STA 727E, 727G, 727I, AND 727J. GROUNDED - YES. CUT OUT AND REPAIRED DAMAGED SECTION OF TRACK IAW SRM 53-00-53-2R-3.SDR ASAA2018031324117Door Frame · crackedR1 DOOR, BS 294 LOWER DOOR SURROUND CLOSE OUT STRUCTURE CRACKED AT THE BOTTOM ATTACH HOLES. ACFT GROUNDED. ACCOMPLISHED A REPAIR OF THE STUB FRAME IAW EA 900-53-EA-20070.SDR ASAA2018031324019Transition Panel · corrodedAFT CARGO BAY, LT TRANSITION PANEL HAS MULTIPLE AREAS OF CORROSION FROM BS 727A TO 807. ACFT GROUNDED. REMOVED CORROSION WAS FOUND TO BE OUT OF LIMITS, REPAIRED THE TRANSITION PANEL IAW SRM 53-00-53-2R.SDR ASAA2018031324016Baffle · bentBENT BAFFLE BETWEEN BS 727A TO 727B LT. ACFT GROUNDED. REMOVED AND REPLACED THE BAFFLE BETWEEN STA 727A AND 727B IAW B737 900 SRM 51 40 02 0G 0 PARA 7D.SDR ASAA2018031224205Cargo Track · corrodedAFT CARGO PIT FLOOR SUPPORT TRACK HAS CORR AROUND TIE DOWN POINT AT STA 727A LBL16. GROUNDED - YES. REPAIRED DAMAGED SECTION OF CARGO TRACK IAW SRM 53 00 53 2R 3 W 1IN. O .072 R .054 L 3FT. D .018.SDR ASAA2018031123986Skin · crackedCRACK, 3.5" AFT OF EXISTING REPAIR, JUST INBOARD OF STAB STA 138.70 RT SIDE. CRACK LENGTH APPROX 1" IN LENGTH. GROUNDED - YES. REMOVED EXISTING DOUBLER ON RT HORIZ STAB IAW SRM 51-40-02. FABRICATED NEW DOUBLER, INCORPORATING NEW AND OLD DOUBLER IN 1 DOUBLER IASDR ASAA2018031024006Floorbeam · corrodedAFT CABIN FLOORBEAM TEE CAP CORRODED AT BS 947, RBL 50. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51. FABRICATED A REPAIR IAW SRM 53-70-51-2R-5. ALODINED IAW SRM 51-20-01. PRIMED IAW SOPM 20-41-02. INSTALLED REPAIR IAWSDR ASAA2018031023984Strap · corrodedAFT CABIN, FLOOR STRAP CORRODED. BS 1006 - BS 1018, RBL 3. GROUNDED - YES. REMOVED AND REPLACED FABRICATED FLOOR STRAP P/N 147A5714-4 AT BS 1006, BS 1018 RBL 3 IAW WG 147A5700 REV A AND SRM 51-40-02.SDR ASAA2018031023896Strap · corrodedAFT CABIN, FLOOR STRAP CORRODED AT BS 1026, LBL 17. ACFT GROUNDED. REMOVED AND REPLACED THE STRAP IAW DWG 147A5700, REV A, AND SRM 51-40-02.SDR ASAA2018030924102Stringer · corrodedCORRODED STRINGER 25L IN THE AFT OF AFT CARGO BAY, BS 986 - 1006. ACFT GROUNDED. REMOVED AND REPLACED THE STRINGER IAW SRM 53-00-03-2R-1.SDR ASAA2018030924070Floor Support · corrodedMAIN CABIN FLOOR SUPPORT CORRODED AT SEVERAL AREAS, BS 294.5 - 328, RBL 58. ACFT GROUNDED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-10-15. REPLACED IAW SRM 51-40-02, 51-40-05 AND DWG 141A8310.SDR ASAA2018030924069Floor Panel · corrodedAFT CARGO BAY, RT SIDE FLOOR PANEL HAS SEVERAL NUTPLATES CORRODED BETWEEN BS 767 AND 787. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15. FABRICATED A REPLACEMENT IAW DWG 146A0081, REV A, DWG #146A8123, REV--. REMOVED ANDSDR ASAA2018030923976Intercostal · crackedMAIN CABIN FLOOR SUPPORT, INTERCOSTAL CRACKED BS 294.5 - BS 285, BL 0. GROUNDED - YES. REPLACED INTERCOSTAL BS 294.5 - BS 285, BL 0 P/N 141A5410U3 PO 911662.1 PER BAC DWG 141A5400 REV AG.SDR ASAA2018030923975Transition Panel · corrodedAFT PIT RT SIDE FLOOR TRANSITION PANEL HAS SEVERAL NUTPLATE CORRODED BETWEEN STA 727I+8 AND STA 767. GROUNDED - YES. REMOVED CORROSION - ORIG MAT=.040, MAT REMOVED=.013, REMAINING MAT=.027. FOUND TO BE OUT OF LIMITS BY SRM 53-00-53-1A-2. REMOVED AND REPLACED ASDR ASAA2018030923973Transition Panel · corrodedAFT PIT LT SIDE FLOOR TRANSITION PANEL FROM STA 727G TO STA 727K HAS CORROSION AT NUTPLATE LOCATIONS. GROUNDED - YES. REMOVED CORROSION ON TRANSITION PANEL AT AFT PIT LT STATION 727G +10, 727I AND 727K +10 WITH 100 PERCENT MAT LOSS. FOUND TO BE OUT OF LIMITS ISDR ASAA2018030923855Floor Support · crackedMAIN CABIN FLOOR SUPPORT CRACKED BETWEEN BS 312 & 328, RBL 31. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DRAWING 141AS400, REV.SDR ASAA2018030824064Channel · corrodedR2 DOOR MOP SILL CORRODED, BS 960 - 996. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-15-1A-1, FIG 103, DET D. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE MOPSILLIAW SRM 51-40-02, DWG 147A8540, REV B. AND DWG 147A8501, REV B.SDR ASAA2018030823992Stiffener · corrodedMAIN CABIN AFT WET AREA BS 947, RBL 50 STIFFENER CORRODED. ACFT GROUNDED. REMOVED IAW SRM 51-40-02. LOCATED AND DRILLED IAW DWG 147A5650, REV A. INSTALLED IAW DWG 147A5650, REV A.SDR ASAA2018030823970Stiffener · corrodedMAIN CABIN AFT WET AREA BS 988, RBL 45 STIFFENER CORRODED. ACFT GROUNDED. REMOVED AND REPLACED THE STIFFENER IAW SRM 51-40-02, AMM 51-21-41, AND DWG 147A5700.SDR ASAA2018030823969Stiffener · corrodedMAIN CABIN AFT WET AREA BS 1016, RBL 28 STIFFENER CORRODED. ACFT GROUNDED. REMOVED THE STIFFENER , LOCATED, DRILLED, AND DEBURED A NEW STIFFENER IAW SRM 51-40-02, AND AMM 51-2-41. INSTALLED THE NEW STIFFENER IAW SRM 51-40-02, AND DWG 147A5700.SDR ASAA2018030823967Strap · corrodedMAIN CABIN AFT WET AREA, BS 1016 - 1020, LBL 2, CORRODED ON STRAP. ACFT GROUNDED. REMOVED AND REPLACED THE STRAP IAW DWG 147A5700, REV A, AND SRM 51-40-02.SDR ASAA2018030823966Strap · corrodedMAIN CABIN AFT WET AREA BS 1016, RBL 20, CORRODED ON STRAP. ACFT GROUNDED. REMOVED, LOCATED, AND DRILLED A NEW STRAP IAW AMM 51-21-41, AND SRM 51-40-02. INSTALLED THE NEW STRAP IAW SRM 51-40-02, AND DWG 147A5700.SDR ASAA2018030823964Strap · corrodedMAIN CABIN AFT WET AREA BS 1008, LBL 26 CORRODED ON STRAP. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR STRAP IAW DWG 147A5700, REV A, AND SRM 51-40-02.SDR ASAA2018030724140Battery Pack · no testL1 DOOR EMERGENCY LIGHT BATTERY FAILED A CHECK. ACFT GROUNDED. REMOVED AND INSTALLED A SERVICEABLE BATTERY PACK, OPS CHECKED GOOD IAW AMM 33-51-06-960-805.SDR ASAA2018030724139Battery Pack · no testR1 DOOR EMERGENCY LIGHT BATTERY FAILED A CHECK. ACFT GROUNDED. REMOVED AND INSTALLED A SERVICEABLE R1 DOOR EMERGENCY EXIT LIGHT BATTERY PACK IAW AMM 33-51-06-960-805.SDR ASAA2018030724130Battery Pack · no testLEFT FWD OVERWING EMERGENCY LIGHT BATTERY FAILED A CHECK. ACFT GROUNDED. REMOVED, AND REPLACED THE LT OVERWING EMERGENCY LIGHT BATTERY PACK M1694. EMERGENCY LIGHTS OPS CHECKED GOOD IAW AMM 33-51-06-960-805.SDR ASAA2018030623993Doubler · crackedL1 DOOR UPPER HINGE CUTOUT INTERNAL SURROUND DOUBLER IS CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE DOUBLER IAW DWG 141A8180, REV C, AND SRM 51-40-02.SDR ASAA2018030623965Bulkhead Web · crackedPRESSURE BULKHEAD WEB CRACKED LBL 40, LBL 45.64, BS 663. ACFT GROUNDED. CUT AND REMOVED THE DAMAGED PRESSURE BULKHEAD WEB, AND ACCOMPLISHED A CATEGORY B REPAIR IAW SRM 57-10-10-2R-3, REPAIR 3, ALTERNATIVE 2.SDR ASAA2018030623946Door Sill · corrodedR1 MOPSILL CORRODED. GROUNDED - YES. REMOVED CORR ON R1 MOPSILL AND FOUND TO BE OUT OF LIMITS IAW B737 900 SRM 53 10 15 1A 2 REMOVED MOPSILL (INNER CHORD) AND REPLACED WITH NEW INNER CHORD IAW 737 900 SRM 51 40 02 0G 0 W 3" O .080" R .069" L 6" D .011".SDR ASAA2018030523948Support Angle · corrodedL1 DOORWAY LOWER SILL I/B SCUFF PLATE SUPPORT ANGLE CORRODED. GROUNDED - YES. REMOVED CORR ON L1 DOORWAY LOWER SILL SCUFF PLATE SUPPORT ANGLE AND FOUND TO BE OUT OF LIMITS IAW SRM 53 10 15 1A. REMOVED ANGLE AND REPLACED WITH NEW ANGLE IAW SRM 51 40 02 0G 0 W 1SDR ASAA2018030523920Flange · corrodedAPU INTAKE FLANGE LEADING INTO APU COMPARTMENT HAS CORROSION AROUND FASTENER HOLES ON THE OTBD SIDE. ACFT GROUNDED. REMOVED AND REPLACED THE APU INTAKE FLANGE IAW SRM 51-40-02-0G-0, FIG 8, AND PARA 4, 7D.SDR ASAA2018030523908Flange · corrodedAFT SERVICE AREA, APU INTAKE PLENUM FLANGE ON BULKHEAD BS 1088 HAS CORROSION ON THE FWD FACE. ACFT GROUNDED. REMOVED AND REPLACED AFT SERVICE AREA, APU INTAKE PLENUM FLANGE IAW B737 900 SRM 51 40 02 0G 0 FIR 8 AND PARA 4 W 1.50 O .071 R .061 L 6 D .010.SDR ASAA2018030324047Pan · crackedEXTERNAL POWER RECEPTACLE DOOR INTERNAL PAN FWD DOOR LANDING IS CRACKED. ACFT GROUNDED. REPAIRED EXTERNAL POWER DOOR LANDING IAW EA900 53EA 20021.SDR ASAA2018030223750Sign · inoperativeAFT RT EXIT SIGN NOT ILLUMINATING. GROUNDED - YES. REPLACED COVER AND REPLACED AFT RT EXIT SIGN REF AMM 33-51-01. OPS CHK GOOD.SDR ASAA2018030124073Track · corrodedAFT CARGO BAY RT TRANSITION PANEL TRACK FROM BS 727F TO 727I HAD AREAS OF CORROSION. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED A NEW TRACK IAW SRM 53-00-53-1A-2, AND SRM 51-40-05-0G-0.SDR ASAA2018030124072Transition Panel · corrodedAFT CARGO BAY, LEFT TRANSITION PANEL FROM BS 727 TO 727D HAD AREAS OF CORROSION. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-10-2, REMOVED AND REPLACED THE TRANSITION PANEL IAW SRM 51-40-02-0G-0, FIG 8, AND PARA 4.SDR ASAA2018030124071Transition Panel · corrodedAFT CARGO BAY, LEFT TRANSITION PANEL FROM BS 727I TO 787 HAS AREAS OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE TRANSITION PANEL IAW SRM 51-40-02-0G0, FIG 8, AND PARA 4, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2.SDR ASAA2018030124018Floor Support · damagedAFTER REMOVAL OF FLOORBOARD IN AFT CARGO BAY, FOUND A DAMAGED NUTPLATE AT BS 770 BL0. ACFT GROUNDED. REMOVED AND REPLACED THE DAMAGED FLOOR SUPPORT IAW EA 900 53, EA 20018, REV 00, REV.SDR ASAA2018030123921Transition Panel · corrodedAFT CARGO BAY LT TRANSITION PANEL FROM BS 727D TO 727I HAS AREAS OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE TRANSITION PANEL IAW SRM 51-40-02-0G-0, FIG 8, AND PARA 4.SDR ASAA2018030123919Transition Panel · corrodedAFT CARGO BAY, RT TRANSITION PANEL FROM BS 727I - 767 HAS AREAS OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE TRANSITION PANEL IAW SRM 51-40-02-0G-0, FIG 8, AND PARA 4.SDR ASAA2018030123918Transition Panel · corrodedAFT CARGO BAY RT TRANSITION PANEL FROM BS 727 TO 727E HAS AEAS OF CORROSION. ACFT GROUNDED. REMOVED AND REPLACED THE TRANSITION PANEL IAW SRM 51-40-02-0G-0, FIG 8, AND PARA 4.SDR ASAA2018030123873Door Sill · corrodedAFT CARGO PIT DOOR CUTOUT LOWER SILL WEB HAS CORR. GROUNDED - YES. REMOVED SILL WEB, SILL WEB HAD 100% MATERIAL LOSS, LOCATED, DRILLED AND INSTALLED NEW SILL WEB IAW SRM 51 40 0G 0 SRM 53 60 15 1A 1 AND SRM 51 40 05 0G 0.SDR ASAA2018022823956Web · corrodedFWD CARGO DOOR CUTOUT LOWER SILL WEB CORRODED AT SCUFF PLATE ATTACH HOLES. ACFT GROUNDED. REMOVED AND REPLACED THE WEB IAW SRM 51-40-02-0G-0, FIG 10, AND PARA 5.SDR ASAA2018022523702Sign · unsecureEXIT SIGN IN AFT GALLEY HANGING DOWN. GROUNDED - YES. REMOVED AND REPLACED AFT GALLEY CEILING EXIT SIGN PER AMM 33-51-01. OPS TEST GOOD.SDR ASAA2018020723648Baffle · crackedBAFFLE BETWEEN BS 500G AND 500H IS CRACKED. ACFT GROUNDED. REMOVED AND REPLACED BAFFLE IAW SRM 51-40-02-0G-0.SDR ASAA2018020723647Baffle · crackedBAFFLE BETWEEN BS 500I AND 500J IS CRACKED. ACFT GROUNDED. REMOVED AND REPLACED IAW SRM 51-40-02-0G-0.SDR ASAA2018020723568Baffle · crackedBAFFLE BETWEEN 500H AND 500I IS CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE BAFFLE IAW SRM 51-40-02-0G-0, FIG 8, AND PARA 7D.
Back to Boeing 737-990