Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014051391019Status Message · activatedNO LAND 3 STATUS, LT FCC FAIL. IAW MM 22-10-00 ACCOMPLISHED MCP & FCC TESTS ACFT DOWNGRADED TO CAT 1 STATUS IAW SEQ 5576 001. NEED TO ACCOMPLISH GND RECERTIFICATION TO RESTORE ACFT TO FULL CAT 2 - 3 CAPABILITY STATUS.SDR CALA2014050991006Tension Tie · crackedSTATION 1180 RT SIDE TENSION TIE CRACKED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR IAW SRM 53-40-30 REPAIR 2.SDR CALA2014050991005Tension Tie · crackedSTATION 1200 RT SIDE TENSION TIE CRACKED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR IAW SRM 53-40-30 REPAIR 1.SDR CALA2014050991004Tension Tie · crackedSTATION 1120 LT SIDE TENSION TIE CRACKED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR IAW SRM 53-40-30 REPAIR 1.SDR CALA2014050991003Tension Tie · crackedSTATION 1120 LT SIDE TENSION TIE CRACKED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR IAW SRM 53-40-30 REPAIR 2.SDR CALA2014050991002Tension Tie · crackedSTATION 1160 LT SIDE TENSION TIE CRACKED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR IAW SRM 53-40-30 REPAIR 1.SDR CALA2014050991001Tension Tie · crackedSTATION 1120 RT SIDE TENSION TIE CRACKED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-40-30 REPAIR 2.SDR CALA2014050990999Light · inoperativeIAW A CHECK, 9AB CEILING EMER LIGHT INOPERATIVE. REPLACED BULB & BATTERY CHARGER, NO HELP. NO LIGHT ASSEMBLY AVAILABLE.SDR CALA2014050991000Display · faultyFIRST OFFICER`S PFD BLANKED OUT TWICE WITH EICAS, IDS & DU STATUS MSG. REPLACED FIRST OFFICER`S PFD IAW MM 31- 61-02, TEST & OPERATIONS OK.SDR CALA2014050690978Light · inoperativeIAW A CHECK, SEAT EEL 47ABC INOPERATIVE. REPLACED SEAT EEL AT 47A, OPERATIONS CHECKED OK.SDR CALA2014050690980Skin · dentedDENT ON APU RT DOOR EXTERNAL SKIN AT STATION 2472 S=0.4X0.4 HFEC, NO CRACK. MEASURED THE DENT DEPTH=0.002 & WIDTH=0.46 WIDTH=W & DEPTH=Y SO W-Y=230>30 & Y<0.125.SDR CALA2014050690977Unknown · malfunctionedEMERGENCY LIGHTS FLICKER IN FLIGHT. SUSPECT DOOR 1L SWITCH INTERMITTENT. CHECKED EMERGENCY LIGHTS SWITCH AT DOOR 1L, NO FAULT NOTED. UNABLE TO DUPLICATE THE PROBLEM. REVIEWED WORK HISTORY, REPLACED BATTERY PACK FOR ROW 22 - 26R M6006 AS PRECAUTIONARY. ACCOSDR CALA2014050690982Warning System · false activationSTATUS MSG ENG 1 OVHT LP B DISPLAYED ON EICAS. SWAPPED CARDS NO HELP.SDR CALA2014050690981Battery · dischargedDOOR 1R EMER SLIDE LIGHT IS INOPERATIVE. REPLACED BATTERIES IN LIGHT ASSEMBLY. OPERATIONS CHECKED GOOD.SDR CALA2014050290952Power Supply · inoperativeRIGHT OVERWING EEL LIGHTS OUT, 4 EACH. CHANGED THE PACK WHEN ONLY THE TOP TWO WERE OUT. NOW NONE OF THE FOUR LIGHTS WILL RUN. REPLACED POWER SUPPLY M79 20 IAW SSM 33-51-04.SDR CALA2014043090922Skin · cracked2.5 INCH SKIN CRACK, DOOR 5L UPPER AFT CORNER. TRIMMED OUT DAMAGE & INSTALLED DOUBLER-TRIPLER-QUAD REPAIR IAW ECRA 5330-04828, N R 169517.SDR CALA2014043090927Light · inoperativeIAW A CHECK, SEAT EEL AT 36ABC, INOPERATIVE. REPLACED SEAT EEL LIGHT.SDR CALA2014043090926Battery Pack · dischargedIAW A CHECK, LT SIDE OVERWING EMERGENCY LIGHTS, 2 EACH AFT, INOPERATIVE. CHANGED BATTERY PACK, OPERATIONS CHECKED GOOD.SDR CALA2014043090925Battery Pack · weakIAW A CHECK, DR 1R, DOOR EXIT SIGN DIM. REPLACED BATTERY PACK.SDR CALA2014043090924Light · inoperativeIAW A CHECK, DR 4L, DOOR LIGHT, INOPERATIVE. REPLACED DOOR LIGHT AT DR 4L.SDR CALA2014043090923Light · defectiveIAW A CHECK, DOOR 1R, EXIT SIGN & DOOR LIGHT ARE BOTH DIM. REPLACED LIGHT ASSEMBLY, OPERATIONS CHECKED OK.SDR CALA2014043090921Warning System · false activationREV 1 INTERLOCK EICAS STATUS MSG DISPLAYED. NR 1 ENG REVERSER INTERLOCK FAILURE. OPERATED NR 1 REV & INTER LOCK MSG CLEARED.SDR CALA2014042590904Jack · inoperativeFLIGHT INTERPHONE JACK AT NOSE IS INOPERATIVE.SDR CALA2014042190891Actuator · leakingNR 4 TR ACTUATOR LEAKING 8 DROPS PER MINUTE STATIC FROM PRESS FITTING FROM LOWER ACTUATOR AT 7 O CLOCK POSITION. REPLACED LOWER ACTUATOR INBD SIDE LOWER.SDR CALA2014042190890Fire Warning · false activationENG 1 FIRE LOOP B STATUS MSG DISPLAYED ON EICAS. MX MSG 26021, CMC GND TEST WOULD NOT RESET STATUS MSG. IAW FIM 26-11 TASK 852, ENG 1 FIRE WARNING DETECTION CARD LOOP RESISTANCE CHECK WITHIN LIMIT, 1.512 KOHM, FOR PRECAUTION DETECTION CARD. REPLACED IAW MM SDR CALA2014041790859Battery Pack · dischargedEEL SLIDE LIGHTS OUT, LT SIDE, LOWER 2 LIGHTS. REPLACED BATTERY PACK IAW MM33-51-00-032-001, MM33-51-00-432-006 & MM33-51-04-902-001. OPERATIONS CHECKED GOOD IAW PARAGRAPH D OF MM33-51-902-001.SDR CALA2014041790858Light · inoperativeFLOOR LEVEL EEL LIGHT OUT AT SEAT 35C. REPLACED EEL STRIP, OPERATIONS CHECKED OK.SDR CALA2014041790846Fire Warning · faultedENG 1 FIRE LOOP B STATUS MSG DISPLAYED ON EICAS. MAINT MSG 26021, CMC GND TEST WOULD NOT RESET STATUS MSG.SDR CALA2014041790842Control Unit · faultyAIRCRAFT FROM HANGAR WITH BCU 1 FAULT WITH ASSOCIATED EIU L MESSAGES. REPLACED BCU 1 IAW AMM 24 -23-01, OPERATIONS CHECKED NORMAL.SDR CALA2014041490829Unknown · malfunctionedCAPTAIN`S NR 2 WINDOW HEAT INOPERATIVE. CYCLED CB, OPERATIONS CHECKED OK NO FAULTS FOUND.SDR CALA2014040890790Roller · brokenWHILE OPENING THE DOOR 5L UPON ARRIVAL, THE RAMP AGENT REPORTED THAT HE HEARD A LOUD BANG & THE DOOR WAS THEN HANGING CROOKED. FOUND L5 DOOR EMERGENCY SYS LINKAGE ARM ROLLER & BEARING BROKEN. CLOSED & LOCKED L5 DOOR. PERFORMED PRESS CHECK, NO LEAKS NOTED. SDR CALA2014040390767Unknown · out of adjustWHILE FILLING THE NR 2 RESERVE FUEL TANK TO FULL, 9.2, FUEL STARTED TO MOVE OUT OF THE FWD VENT TUBE IN THE LT SURGE TANK. VENT TUBE LOCATED IN THE CEILING OF THE OTBD ACCESS PANEL FOR THE LT SURGE TANK. THE FWD FUEL VENT DRAIN VLV WAS SUSPECTED BAD. CHECKESDR CALA2014033190740Power Supply · malfunctionedROWS 51 TO 61HJK EMERGENCY LIGHTS INTERMITTENT. LIGHTS ILLUMINATE WHEN SELECTED ON, INTERMITTENT FLASH WHEN SELECTED OFF, ADJACENT LIGHTS NORMAL. IAW CH1727 REPLACED POWER SUPPLY M6012 ABOVE DOOR 5RT, EEL PATH LIGHTS ROW 51HJK TO 61HJK CHECKED OK IAW WD33-51SDR CALA2014031990647Cover · out of adjustAISLE EMERGENCY GUIDANCE LIGHTS ON WHEN NOT COMMANDED TO BE ON. ROWS 54 - 60 RT SIDE ADJUSTED DOOR 1L SWITCH COVER.SDR CALA2014031990645Fan · faultyHOT OIL OR SMOKE ODOR IN AFT CABIN ALONG WITH RECIRCULATION FAN UPPER RT MSG, TURNED OFF UPPER RECIRCULATION FAN & ODOR DIMINISHED. PULLED & CAPPED CB FOR RT UPPER RECIRCULATION FAN. INSPECTED CABIN LIGHTING, GALLEYS & CEILING FOR ANY DEFECTS, NONE FOUND. CSDR CALA2014031990646Connector · dirtyENG 2 SQUIB TEST USING TEST SW NR 2 DOES NOT ILLUMINATE GREEN SQUIB TEST LIGHT. CLEANED & RESEATED SQUIB CONNECTORS DM228B & DM229B IAW SSM26-21-02. SQUIB TESTED NORMAL IAW AMM26-21-00.SDR CALA2014031290597Connector · unsecureSEAT 51HJK EMERGENCY EXIT LIGHT STRIP INOPERATIVE. SECURED CONNECTOR IAW MM 33-51-12-201-C03, OPERATIONS CHECKED OK.SDR CALA2014031290587Connector · unsecureSEAT 51 HJK EMERGENCY EXIT LIGHT STRIP INOPERATIVE. SECURED CONNECTOR IAW MM 33-51-12-201-C03, OPERATIONS CHECKED OK.SDR CALA2014031090580Battery · dischargedEMERGENCY LIGHT STRIPS ON INTERMITTENTLY ROW 51 TO 61. REPLACED BATTERY ASSEMBLY.SDR CALA2014030790549Unknown · malfunctionedON LANDING GOT EICAS OUTFLOW VLV RT. VLV HAS BEEN DEACTIVATED, CLOSED REMAINING VLV. OPERATED NORMALLY ON AUTO & MAN CB`S P6 PANEL RT. CABIN PRESS CONTROL RT ICU & PANEL 414 CABIN PRESS ICU RT ARE OPEN & SAFE TIED.SDR CALA2014030390535Light · inoperativeLT CEILING EMERGENCY LIGHT ROW 6 INOPERATIVE. RELAMPED IAW MM 33-51-07- 201.SDR CALA2014030390534Light · inoperativeAFT SEAT EMERGENCY LIGHT INOPERATIVE SEAT 15AB. RELAMPED IAW MM 33-51-12- 201-C03.SDR CALA2014030390533Light · inoperativeEMERGENCY CEILING LIGHT INOPERATIVE & LENS MISSING ROW 13. RELAMPED IAW MM 33-51-07- 201 & ORDERED LIGHT ASSEMBLY 585-1836 FOR LENS.SDR CALA2014030390531Unknown · malfunctionedEMERGENCY LIGHTS ON WHEN SWITCH IN OFF POSITION. SWITCH CYCLED, OPERATIONS CHECKED OK.SDR CALA2014030390532Socket · damagedELECTRICAL BURNING SMELL AT ROW 16 UPPER DECK. FOUND MELTED SOCKET AT SIDE WALL LIGHT 15A. REMOVED FLUORESCENT LIGHT BULB TO ISOLATE EVIDENCE OF SMELL, INSPECTED AREA IAW FIM 21-00-810, NO MORE SMELL NOTED. REPLACED BURNED SOCKET & RELAMPED, LIGHTS INOPERATSDR CALA2014030390530Skin · crackedNR 1 PYLON RT SIDE SKIN AT NACELLE STATION 244, ACCESS PANEL 482ER CUTOUT AFT LOWER CORNER CRACKED. REPAIRED IAW ECRA 5450-02150.SDR CALA2014030390529Skin · crackedNR 1 PYLON RT SIDE SKIN AT NACELLE STATION 244, ACCESS PANEL 452ER CUTOUT AFT LOWER CORNER CRACKED. REPAIRED IAW ECRA 5450-02149.SDR CALA2014022790492Light · inoperativeOVERWING EMERGENCY SLIDE LIGHTS INOPERATIVE. FOUR EACH, UPPER TWO SLIDE LIGHTS ON THE RT SIDE & LOWER TWO SLIDE LIGHTS ON THE LT. CHANGED POWER SUPPLIES FOR BOTH SIDES, NO HELP. RELAMPED BOTH SIDES, NO HELP. CHANGED NR 3 LT SLIDE LIGHT ASSEMBLY, NO HELP. SDR CALA2014022590440Aileron · damagedLT AILERON TE HAS SPEED TAPE PEELING OFF, .6 INCHES OF THE REPAIR MATERIAL MISSING & 3 INCHES PEELING OFF. NO DELAMINATION ON LOWER UPPER SURFACE OF AILERON TE. REMOVED DAMAGED CONDUCTIVE STRIP & REPLACED WITH NEW FABRICATED PART IAW AMM57-51-03P80 1. MEASURSDR CALA2014022190428Trim Panel · defectiveEMERGENCY LIGHTS AT LAVATORY 102 SIDEWALL WIRES EXPOSED. REPLACED CORNER TRIM.
Back to Boeing 747-422