SDR CALA2013090591054Channel · crackedBS 1160 LT TENSION TIE FWD CHANNEL CRACKED AT FASTENER HOLE. REMOVED DAMAGE, MANUFACTURED & INSTALLED REPAIR CHANNELS & ANGLES IAW SRM 53-40-30 REPAIR 2.SDR CALA2013090591053Channel · crackedBS 1120 TENSION TIE RT FWD CHANNEL CRACKED AT FASTENER. REMOVED DAMAGE, MANUFACTURED & INSTALLED REPAIR CHANNELS & ANGLES IAW SRM 53-40-30 REPAIR 2. 5.SDR CALA2013090591052Channel · crackedBS 1120 LT TENSION TIE FWD CHANNEL CRACKED AT TWO FASTENER HOLES. REMOVED DAMAGE, MANUFACTURED & INSTALLED REPAIR CHANNEL & ANGLES IAW SRM 53-40-30, REPAIR 2.SDR CALA2013090591051Web · crackedMAIN DECK COMPARTMENT FLOOR BEAM SUPPORT WEB IS CRACKED STATION 142, LBL 42. CUTOUT DAMAGE & INSTALLED REPAIR IAW SRM53-10-51-RPR 7. N-R 0370636.SDR CALA2013090591050Frame · crackedBS 1180 TENSION TIE RT FRAME CRACKED AT FASTENER HOLE. INSTALLED NEW FRAME SEGMENT IAW SRM 53-40-07 REPAIR 4.SDR CALA2013090591049Frame · crackedBS 1160 RT TENSION TIE FRAME CRACKED AT FASTENER HOLE. INSTALLED NEW FRAME SEGMENT IAW SRM 53-40-07 REPAIR 3.SDR CALA2013090591048Frame · crackedBS 1120 RT TENSION TIE FRAME CRACKED AT FASTENER HOLE. INSTALLED NEW FRAME SEGMENT IAW SRM 53-40-07 REPAIR 1.
SDR CALA2013090591042Shear Web · crackedBS 1120 RT CANTED SHEAR WEB CRACKED AT FASTENER HOLE. REMOVED DAMAGE, MANUFACTURED & INSTALLED REPAIR DOUBLER IAW AMM 53-10-99 PAGE 208 PARA 10 D.SDR CALA2013090591041Shear Web · crackedBS 1120 LT CANTED SHEAR WEB CRACKED AT FASTENER HOLE. REMOVED DAMAGE, MANUFACTURED & INSTALLED REPAIR DOUBLER IAW AMM 53-10-99 PAGE 208 PARA 10 D.SDR CALA2013082990846Control Panel · faultyWEATHER RADAR WILL NOT TEST. FOUND MESSAGE 34010. REPLACED WEATHER RADAR CONTROL PANEL, IAW FIM & AMM. SYSTEM CHECKED GOOD.SDR CALA2013082990830Wire Harness · damagedSEATS 33C-43C EMERGENCY EXIT LIGHTS INOPERATIVE. FOUND DAMAGED WIRE RUN AT SEATS 42ABC BETWEEN SEAT ELECTRONICS UNIT & EMERGENCY LIGHT ASSEMBLY AT EDGE OF SEAT ASSEMBLY, REMOVED DAMAGED WIRE HARNESS PN:7844-65,PCN 560-4778.SDR CALA2013082990829Light · inoperativeEMERGENCY CEILING LIGHT ROW 17 INOPERATIVE. RELAMPED IAW MM.SDR CALA2013082990828Light · inoperativeSEAT 16B AFT EMERGENCY LIGHT INOPERATIVE. RELAMPED & TESTED IAW MM 33-51-00-501.SDR CALA2013082990827Light · inoperativeCEILING EMERGENCY LIGHT AT ROW 15 INOPERATIVE. RELAMPED.SDR CALA2013082990826Light · inoperativeSEAT 50H EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED SEAT 50H EMERGENCY EXIT LIGHT ASSEMBLY. OPERATIONS CHECKED OKAY.SDR CALA2013082990825Light · inoperativeSEAT 23C EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED SEAT 23C EMERGENCY EXIT LIGHT ASSEMBLY, OPERATIONS CHECKED OKAY.SDR CALA2013090290895Connector · unsecureEMERGENCY LIGHTS AT DOOR 3L & DOOR 4L AFT SIDE IS INOPERATIVE. RESECURED LIGHT ASSEMBLY CONNECTOR AT BOTH DOOR 3L & DOOR 4L. OPERATIONS CHECKED GOOD.SDR CALA2013090290894Light · inoperativeEMERGENCY LIGHT AT CEILING ABOVE SEATS 8 LT, SEAT 10 LT & SEAT 25 LT AISLES INOPERATIVE. RELAMPED EMERGENCY CEILING LIGHTS AT SEATS 8 LT & 10LT & 25 LT AISLE. OPERATIONS OKAY.SDR CALA2013082690768Light · inoperativeEMERGENCY LIGHT UPPER DECK AISLE LT AT SEAT 13LT AFT POSITION & SEAT 15LT AFT POSITION INOPERATIVE. RELAMPED 13LT & 15LT AFT POSITIONS. CHECKED OK.SDR CALA2013082690756Power Supply · inoperativeMAWEA ID CARD. REPLACED MAWEA CARD POWER SUPPLY B. MESSAGE CLEARED & TESTED GOOD.SDR CALA2013082690755Light · inoperativeEMERGENCY LIGHT AT DOOR2 X-AISLE (CTR) & DOOR5 LT X-AISLE IS INOPERATIVE. RELAMPED DOOR2 X-AISLE (CTR), CHECKED OK. DOOR5 LT X-AISLE EMERGENCY EXIT LIGHT STILL INOPERATIVE. EMERGENCY LIGHT AT DOOR2 X-AISLE (CTR) & DOOR 5 LT X-AISLE IS INOPERATIVE. RELAMPEDSDR CALA2013082390696Switch · inoperativeFUEL MAIN TANK 1 AFT SWITCH LIGHT IN COCKPIT OVERHEAD WILL NOT ILLUMINATE. REPLACED NR 1 AFT MAIN TANK PRESSURE SWITCH IAW AMM. LEAK AND OPS CK OK.SDR CALA2013082390695Battery Pack · inoperativeEMERGENCY LIGHTS ON AT LT DOOR ON LANDING. REPLACED BATTERY PACK. OPS CHECKED GOOD.SDR CALA2013082390704Sensor · dirtyCABIN TEMP CONTROL ISSUES LV2 CLEANED TEMP SENSORS, AND CHECKED FANS FOR AIRFLOW.SDR CALA2013082190642Window · crackedPER EQ6149 CHECK NR 3 RT WINDOW. ON CHECK FOUND NR 3 RT WINDOW FORWARD LOWER CORNER CRACK. WINDOW REPLACED PER AMM AND WINDOW HEAT CHECKED SATIS.SDR CALA2013082190636Battery · dischargedMAIN AND APU BATTERY DISCHARGED AND NEEDED TO BE CHANGED. INSTALLED APU AND SHIP BATTERY PER MM.SDR CALA2013082190635Fairing · gougedON W-A FOUND GOUGE IN FUSELAGE. ON W-A FOUND GOUGE IN FUSELAGE BODY FAIRING 191DDL. DAMAGE PENETRATED OUTER SKIN OF PANEL LENGTH 4.25 INCHES. DEPTH 0.025 WIDTH 1 INCH. AS PER ECRA 5320-02141 ACP VISUAL CHECKED EVERY 500 HRS AND RPR PER PART 3 ON OR BEFORE SDR CALA2013082190638Seal · brokenLIFE VEST SEALS BROKEN, MISSING 2A, 3A, 6K , 8G, 10K. KICK PANEL SEALS BROKEN, MISSING 10A, 20K, 21K, 22K, 23K, 24A, 24K, 25K. REPLACED MISSING SECURITY SEALS.SDR CALA2013082190637Isolation Valve · faultyAPU BLEED VALVE WILL NOT OPEN. REPLACED APU BLEED ISOLATION VALVE PER MM. CHECKED OKAY.SDR CALA2013082190633Motor · failedCREW LOST CABIN PRESS, RTFL LEFT OUTFLOW VALVE FAILED & CABIN ALT HORN CAME ON AT 10000 FT. CREW LOST THE CABIN, DESCENDED TO 8000 FT RT OUTFLOW VALVE WOULD NOT MAINTAIN CABIN PRESS. INVEST FOUND MAINT MESS 21207 DISPLAYED & LATCHED HARD. REF MAINT MESS 2120SDR CALA2013082090611Fitting · crackedBS 1000 STRINGER 38L LBL 78, CRACK FOUND AT BATH TUB FITTING INSIDE CENTER TANK DURING HMV VISIT. REPLACED FITTING IAW SRM AND SEALANT APPLIED PER MM.SDR CALA2013082190641Button · unsecureMIC SEL CAP ON CAPTAIN`S RADIO CONTROL PANEL PA BUTTON CAME OFF. REPLACED AUDIO CONTROL PANEL.SDR CALA2013082190634Connector · disconnectedCEILING EMERGENCY LIGHT AT ROW 59HJK INOPERATIVE. RELAMPED CEILING LT AT 59HJK (RT AISLE) BUT NO HELP. RANG FOR POWER--NO POWER. DROPPED CEILING PANEL & FOUND CONNECTOR DISCONNECTED. RESECURED CONNECTOR & OPERATION GOOD. RE-INSTALLED CEILING PANEL.SDR CALA2013082090585Smoke Detector · failedSTATUS MESSAGE-EE CLNG SUP FAN. FOUND EQUIPMENT COOLING SMOKE DETECTOR FAILED. INSTALLED NEW DETECTOR. SYSTEM OPS CHECKED NORMAL.SDR CALA2013082090584Duct · leakingNR 1 ENGINE HAS PNEUMATIC LEAK BELOW J-BOX 11:30 POSITION. PRESSURIZED DUCT, NO LEAKS NOTED. NO EVIDENCE OF BLEED AIR LEAKS NOTED.SDR CALA2013082190639Unknown · unknownEMERGENCY EVACUATION SYSTEM IS EMITTING LOW LEVEL OFF BEAT SIGNAL. PULLED CIRCUIT BREAKER TO SILENCE ALARM, REVIEWED WDM TO VERIFY CIRCUIT BREAKER IS SOLELY FOR EVAC SIGNAL SYSTEM 25- 63-11 & -12. RDF-T :DISCONNECTED ALL DOORS EVAC UNIT & OVERSTAIR & RECONNESDR CALA2013081990534Girt Bar · out of alignmentR2 DOOR DOES NOT ARM. GIRT BAR REALIGNED.SDR CALA2013081990533Panel · damagedOTBD NR 1 SAIL TAIL DOOR HAD POPPED RIVETS ON L/E APPROX 1 FT FROM LOWER EDGE. INSTALLED PANEL.SDR CALA2013081990512Line · leakingEXTREME STRONG ODOR OF FUEL IN CABIN. APPEARS TO BE CENTERED AROUND THE OVERWING AREA. REPLACED ALL HST FUEL LINES.SDR CALA2013081990510Blade · nickedNR 2 ENGINE FAN BLADE NICKED. ACCOMPLISHED INITIAL BLEND. PERFORMED EDDY CURRENT INSPECTION ON BLENDED FAN BLADES. NO CRACK INDICATIONS FOUND. ACCOMPLISHED FINAL BLEND ON BLADES IAW MM.SDR CALA2013081990531Antenna · inoperativeWEATHER RADAR WILL NOT TEST. WXR ANNTENA REPLACED IAW AMM & CMC GROUND TEST PASS.SDR CALA2013090490985Light · inoperativeLT COVER AT GALLEY LT 609 AT ECONOMY GALLEY 431 BURNT. REPLACED LENS 560-3997 & RELAMPED IAW MM, OPERATIONS CHECKED OK.SDR CALA2013081990532Blade · damagedNR 2 ENGINE FAILED BORESCOPE IAW EM4166, HPT T2 BLADE ONE HALF A BLADE MISSING AND BLADE NEXT TO IT HAS TIP DAMAGE. REPLACED NR 2 ENG IAW MM.SDR CALA2013081990511Pump · faultyNR 1 HYD LOW QTY EICAS MESSAGE CAME ON AT .27 AND CONTINUED DOWN TO .17. FOLLOWED CHECKLIST PROCEDURES AND SHUTDOWN NR 1 EDP AND ADP. QUANTITIES AND PRESSURES FOR 2, 3 & 4 ARE NORMAL. REPLACED NR 1 ENG HYD PUMP, LEAK AND OPS CK GOOD.SDR CALA2013081990509Tube · leakingNR 3 ENGINE, FUEL DRIPPING FROM INSIDE THRUST REVERSER COWL AT A RATE OF 40 DROPS A MINUTE. ACCOMPLISHED IDLE AFTER ENG SHUTDOWN FOUND FUEL LEAKING FROM FM 11 TUBE AND SHROUD TORN. REMOVED FM11. LEAK CHECKED AND TEST IAW MM. SECURE (PARTIAL). VERIFIED SASDR CALA2013081990508Wire Harness · failed"DET FIRE-OHT 3" EICAS ADVISORY MESSAGE DISPLAYED. NR 3 ENGINE LOOP "A" AND "B" FAILURES FOR FIRE OR OVERHEAT. REPLACED WIRE HARNESS AT FWD LOWER SECTION FOR THE LOOP. FIRE AND OVERHEAT TEST FUNCTIONALLY DONE IAW AMM.SDR CALA2013081690490Seal · failedNR 4 ENGINE IDG HAS BAD SEAL TO GEARBOX.SDR CALA2013081390384Seal · leakingR5 DOOR AIR LEAK. RESEALED DOOR AREA AND PRESS CHECKED. STILL LEAKING OUT OF LOWER GATE ROD ARM ATTACH AREA. FILLED WITH SEALANT IN SAID AREA.SDR CALA2013081390383Wire Harness · faulty"ENG 3, FIRE LP A" DISPLAYED. FOUND WIRE HARNESS W3506- 503-16R AT FAULT BETWEEN LWR FWD AND LWR AFT LOOP IAW WDM 26-11-3-4 PG1.SDR CALA2013081290356Structure · crackedFORWARD CARGO DOOR DENTED AND CRACKED 12" FROM AFT EDGE AND BOTTOM OF CARGO DOOR. IAW ECRA 5230-01927 NEED TO ACP PERMANENT SRM SKIN REPAIR WITHIN 3 A-C CYCLES (PTC 10693 MAX) IAW SRM 52-30-01, REPAIR 2. DVI REPAIR AREA IS TO BE ACP PRIOR TO EACH DEPARTURE C