Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011011200195Lamp · inoperativeEMERGENCY LIGHT ALONG DR2 RT AISLE INOP. RELAMPED. OP CHECKED NORMAL.SDR UALA2011011200194Feeder Cable · faultedEMERGENCY LIGHT FWD AND SIDE OF MAIN GALLEY WALL ON L4 DOOR INOPERATIVE. REPLACED EMERGENCY CABLE ALONG FWD WALL GALLEY. OP CHECKED NORMAL.SDR UALA2011011200193Feeder Cable · damagedEMERGENCY LIGHT ROW 45 THROUGH 53 INOP. REPLACED EMERGENCY CABLE. OP CHECKED NORMAL.SDR UALA2011011200165Lavatory · underservicedLAVS INOP, FLIGHT DIVERTED. APPEARS FWD TANKS (LT AND RT) ARE SHUTDOWN. NO AHM DATA SHOWING ANY FAILURES. SENSOR "INOP" LIGHTS ARE ILLUMINATED ON ACCESS PANEL (R2 DOOR) FOR LAV BOTH FWD LAV TANKS. LAVATORY TANKS SERVICED PROPERLY AND ALL LIGHTS WENT OUT WISDR UALA2011011200164Light · unsecure21HJK SEAT MOUNTED EMERGENCY LIGHT STRIP ADRIFT. SECURED EMERGENCY LIGHT. OPS NORMAL.SDR UALA2011011200163Light · damagedLAV 102 EMERGENCY EVACUATION LIGHT AT BOTTOM OF LAV COMING OFF. REPAIRED LIGHT.SDR UALA2011011000154Window · crackedFLIGHT DECK WINDOW R3 HAS MULTIPLE CRACKS AROUND EDGES. WINDOW REMOVED CONTINUE INSTALLATION PER MM. REPLACED NR 3R WINDOW PER MM.SDR UALA2011011000152Fuse · inoperativeLEFT OVERWING 2 AFT EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE, CHECKS OKAY.SDR UALA2011011000151Lamp · inoperativeRT EMERGENCY CEILING LIGHT INOP ACROSS FROM FIRST CLASS GALLEY. RELAMPED, CHECKS OKAY.SDR UALA2011011000150Lamp · inoperativeSEAT 45R EMERGENCY LIGHT INOPERATIVE. RELAMPED, CHECKS OKAY.SDR UALA2011011000149Lamp · inoperativeSEAT 43L EMERGENCY LIGHT INOPERATIVE. RELAMPED CKS OK.SDR UALA2011011000147Skin · crackedLARGE CRACK IN RIGHT WING FIXED LEADING EDGE UPPER SKIN PANEL JUST INBOARD OF NR 3 ENG. ACCOMPLISHED 250 DEG. PREP REG REPAIR AND APPLIED NON CHROMATED COMPOSITE PRIMER. NEEDS TOP COATED.SDR UALA2011011000145Skin · damagedEVIDENCE OF LEFT WING TIP SCRAPE ON UPPER TOP SURFACE AFTER TOW INTO GATE ON AIRCRAFT ARRIVAL. WINGLET TIP SCRAPE LENGTH 34 INCH. MAIN GOUGE AREA IS 2 INCH LONG, STARTING 3'5 INCH FROM AFT TIP EDGE, DEEPEST GOUGE DEPTH IS 0'118 INCH. AFT TIP CURL IS 0'551 ISDR UALA2011010700105Lamp · inoperativeEMERGENCY LIGHT ON GALLEY WALL LT ACROSS LAV 100 INOP. RELAMPED EMERGENCY LIGHT. OP CK NORMAL.SDR UALA2011010600080Feeder Cable · inoperativeEMERGENCY CROSSOVER LIGHT BETWEEN LAVS NEAR FLOOR BETWEEN DOORS 3R AND 3L IS INOP. REPLACED FEEDER CABLE CHECKED OKAY.SDR UALA2011010600099Battery · dischargedCHARGER BATTERY APU STATUS MESSAGE FOUND DURING PREFLT CHECK. REPLACED APU BATTERY AND CHARGER PER MM.SDR UALA2011010400070Lamp · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 2 GALLEY AREA CENTER LOWER WALL. RELAMPED.SDR UALA2011010400069Lamp · inoperativeEMERGENCY EXIT LIGHT INOP SEAT ROW 50 RIGHT. REPLACED LAMP.SDR UALA2011010400068Lamp · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 5 RIGHT AFT SILL. RELAMPED.SDR UALA2011010400067Lamp · inoperativeEMERGENCY EXIT LIGHT INOP ACROSS DOOR 3 LEFT LOWER WALL. RELAMPED.SDR UALA2011010400066Connector · shortedEMERGENCY EXIT LIGHTS INOP SEAT ROWS 45 THRU 54 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LEFT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ONSDR UALA2011010400065Feeder Cable · faultyEMERGENCY EXIT LIGHTS INOP. ACROSS DOOR 3 RIGHT LOWER WALL AND EMERGENCY LIGHT BETWEEN LAVS 111 AND 112 LOWER WALL. REPLACED POWER FEEDER CABLE. LIGHTS OPS CHECKED NORMAL.SDR UALA2011010400064Light · unsecureEMERGENCY EXIT LIGHT HANGING FROM WALL AT DOOR 1 RIGHT CORNER OF LAV 101. LIGHT WORKS. SECURED LIGHT ASSY.SDR UALA2011010400063Lamp · inoperativeEMERGENCY EXIT LIGHT INOP BY DOOR 2 RIGHT CORNER OF LAV 102 BOTTOM LIGHT. RELAMPED. OPS CHECKED NORMAL.SDR UALA2011010400062Lamp · inoperativeUPPER DECK EMERGENCY EXIT LIGHT INOP AT SEAT 16 LT AFT LIGHT. RELAMPED, OPS CKS NORMAL.SDR UALA2011010400071Light · unsecureEMERGENCY LIGHTS AND STRIP OF TRIM ARE FALLING OFF THE WALL. SECURED TRIM PIECE AND VERIFIED EMERGENCY LIGHTS WORKING OK.SDR UALA2011010400045Angle · crackedWEB ANGLE FOR LT INBOARD BODY GEAR DOOR HINGE SUPPORT STRUCTURE HAS 3 INCH CRACK. REMOVED LT BODY GR DR, AFT DR FTG AND CTR PNL FOR ACCESS. REMOVED CRACK CHANNEL, REPLACED.SDR UALA2011010300031Wire · brokenSEAT 2A EMERGENCY LIGHT INOP. REPAIRED BROKEN WIRE UNDER FOOT CUSHION, OPS CHECKS GOOD.SDR UALA2011010300030Lamp · inoperativeEMERGENCY LIGHT ON WALL DOOR 2R 1 INOP. RELAMPED. OP CHECKED NORMAL.SDR UALA2011010300022Fuse · inoperativeLEFT WING OVERWING EMERGENCY LIGHT 2 TOP INOP. REPLACED FUSE ON BATTERY CHARGER. OPS CHECKED NORMAL.SDR UALA2011010300023Lamp · inoperativeEMERGENCY LIGHT, 1 LIGHT ALONG AISLE BETWEEN L2 DOOR. RELAMPED. OP CHECKED NORMAL.SDR UALA2011010300019Lamp · inoperativeDR 4L UPPER SILL EMERGENCY LIGHT INOP. RELAMP SILL LIGHT DR 4L, OPS CHECKED OK.SDR UALA2011010300018Lamp · inoperativeUPPER DECK EMERGENCY LIGHT ROW 15 INOP. RELAMP ROW 15 CEILING LAMP OPS CHECKED OK.SDR UALA2011010300017Light · inoperativeCEILING EMERGENCY LIGHT UPPER DECK ROW 14 INOPERATIVE. RELAMPED, OPS CHECK OK.SDR UALA2011010300016Lamp · inoperativeUPPER DK CEILING EMERGENCY LIGHT INOP, ROW 17. RELAMPED CEILING LAMP, OPS CK OK.SDR UALA2011010300015Lamp · inoperativeCOCKPIT EMERGENCY CEILING LIGHT INOP. RELAMP OPS CK OK.SDR UALA2010123004769Light · looseEMERGENCY LIGHT STRIP ALONG LAV WALL BY DOOR 1R IS FALLING OFF THE WALL AND WIRES EXPOSED. EMERGENCY LIGHT STRIP RESECURED, OPS NORMAL.SDR UALA2010123004779Fuse · inoperativeLT WING OVERWING EXTERIOR EMERGENCY EXIT LIGHTS INOP. MOST AFT 2 LIGHT ASSY'S. REPLACED FUSE, CHECKS OK.SDR UALA2010122904759Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. FWD STAIRWELL CEILING AFT LIGHT. RELAMPED, CHECKS OK.SDR UALA2010122804752Elevator · odorELECTRIC ODOR WHEN ELEVATOR OPERATED. INSPECTION AND OPS CHECK ON WIRING AND MOTORS, NO EVIDENCE OF OVERHEATING OR ABNORMALITY, OPS SUSPECT RESIDUAL GREASE ON MOTORS. MOTORS FULLY CLEANED. LIFT OPERATED DURING CATERING LOADING, NO ODOR.SDR UALA2010122804751Bulkhead · damagedFOUND FWD BULKHEAD LEAKING, RT SIDE FROM 1200 TO 0600 AT Y CHORD AREA, MARKED LEAK CHECKED FWD PRESSURE BULKHEAD AGAIN, FOUND 3 EA AREAS LEAKING BETWEEN OUTER RING CORD RADIUS AND FUSELAGE SKIN AT 1 O'CLOCK, 2 O'CLOCK & 11 O'CLOCK, AND NUMEROUS LEAKS AT WEB TSDR UALA2010122804750Cart · failedPIG TAIL P42, INOP, HAS ELECTICAL ODOR, AND HOT TO THE TOUCH. COMPLIED WITH MEL PROC, D. CYC: TEST PASS IAW NEW GALLEY CART TESTER, SUSPECT CART WAS BAD.SDR UALA2010122804742Washer · missingFOUND ON THE SUPPORT ROD INSTLALLATION FOR THE OTBD AILERON ACTUATOR POWER CONTROL UNIT WASHERS ARE MISSING FROM UNDER THE NUT SIDE ON THE RT OTBD SUPPORT ROD. RT OTBD AILERON SUPPORT ROD INSTALLATION IS CORRECT.SDR UALA2010122804741Washer · missingFOUND ON THE SUPPORT ROD INSTL FOR THE OTBD AIL ACTUATOR POWER CONTRIL UNIT WASHERS ARE MISSING FROM UNDER THE NUT SIDE ON THE LT OTBD SUPPORT ROD. LT OTBD AILERON SUPPORT ROD INSTALLATION IS CORRECT.SDR UALA2010122704727Charger · inoperativeEICAS STATUS MESSAGE "BATTERY CHARGER". REPLACED APU BATTERY AND REPLACED APU BATTERY CHARGER IAW MM, GROUND OPS CK OK. NO FAULTS NOTED.SDR UALA2010122704706Battery · dischargedAPU BATTERY COMPLETELY DEAD, DUE TO BAT SW BEING LEFT ON WITH NO POWER SOURCE AVAIL TO ACFT. REPLACED APU BATTERY.SDR UALA2010122304700Light · missingEMERGENCY EGRESS LIGHT STRIP MISSING FROM SEAT 48HJK. REPLACED AND ALL OPS NOW NORMAL.SDR UALA2010122104668Actuator · overheatedGALLEY CART LIFT UPPER DECK HAS BURNING ODOR AND RT AREA WARM. UPPER ACTUATOR HOT TO THE TOUCH AND HAS BEEN DISCONNECTED.SDR UALA2010122004654Feeder Cable · inoperativeEMERGENCY LIGHT FWD WALL OF MAIN GALLEY DOOR INOP. REPLACED EMERGENCY LIGHT CABLE. OP CK NORMAL.SDR UALA2010122004653Feeder Cable · failedEMERGENCY LIGHT ROW SEAT 45 THROUGH 51 LT INOP. REPLACED EMERGENCY LIGHT CABLE. OP CK NORMAL.
Back to Boeing 747-422