Boeing 747-451
Service difficulty reports · 2,469
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1015906315Light · disconnectedDURING LINE CHECK, MAINTENANCE FOUND ROW 51 TO 61 RIGHT EMERGENCY PATH LIGHTS INOPERATIVE. MAINTENANCE RECONNECTED THE LIGHT ASSEMBLY. OPERATIONAL CHECK WAS GOOD.SDR DALA1015896302Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THE MOST AFT EMERGENCY EXIT SIGN INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. OPERATIONAL CHECK WAS GOOD.SDR DALA1015956314Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND A/C RIGHT EXTERNAL EMERGENCY LIGHT (3RD FROM FWD) INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AND BATTERY PACK. OPERATIONAL CHECK WAS GOOD.SDR DALA1015916314Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND LEFT EXTERNAL EMERGENCY LIGHT (2ND FROM FRONT) INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AND BATTERY PACK. OPERATIONAL CHECK WAS GOOD.SDR DALA1015346309Power Supply · inoperativeDURING LINE CHECK MAINTENANCE FOUND 2 RIGHT EMERGENCY OVERWING LIGHTS INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. OPERATIONAL CHECK WAS GOOD.SDR DALA1015336309Light · missingDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHT AT G3C MISSING. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. OPERATIONAL CHECK WAS GOOD.SDR DALA1015326313Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHT AT 66H INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. OPERATIONAL CHECK WAS GOOD.SDR DALA1015136312Connector · damagedDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHTS AT ROW 51HJK THROUGH 65HJK INOPERATIVE. MAINTENANCE REPAIRED CONNECTION AT THE LIGHT ASSEMBLY. OPERATIONAL CHECK WAS GOOD.SDR DALA1015116304Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THREE EMERGENCY PATH LIGHTS AT LAV DR1L1 AND DR1L2 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT MODULE. OPERATIONAL CHECK WAS GOOD.SDR UALA2010062402251Connector · saturatedEMERGENCY EXIT LIGHTS VERY DIM SEAT ROWS 45 THRU 53 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. FOUND WATER PUDDLING IN GALLEY AREA UNDER GALLEY MAT AT SDR UALA2010062402250Light · inoperativeEMERGENCY EXIT LIGHT INOP, SEAT ROW 57 LT. REPLACED LIGHT ASSY, OPS CHECK NORMAL.SDR UALA2010062402249Light · inoperativeEMERGENCY EXIT LIGHT INOP. SEAT ROW 53, RT. REPLACED LIGHT ASSY. OPS CK NORMAL.SDR UALA2010062402248Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, UPPER DECK CEILING ROW 15. RELAMPED. OPS NORMAL.SDR UALA2010062402247Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. DOOR 2 GALLEY AREA RT LOWER FWD WALL. RELAMPED. OPS NORMAL.SDR UALA2010062402246Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. UPPER DECK CEILING ROW 14. RELAMPED, OPS NORMAL.SDR UALA2010062402245Lamp · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE IN FLIGHT DECK. RELAMPED. OPS NORMAL.SDR UALA2010062402244Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. UPPER DECK CEILING JUST FWD OF ROW 13. RELAMPED, OPS NORMAL.SDR DALA1014526311Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT BS 1700 LBL50-LBL77. REPAIRED IAW SRM 53-60-51 FIGURE 201.SDR DALA1014516311Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 1680- BS 1720 RBL 40. REPAIRED IAW SRM 53-00-52, FIG 201.SDR DALA1014506311Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 1660- BS 1680 LBL 40. REPAIRED IAW SRM 53-00-52 FIG 201.SDR DALA1014496311Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 1700-1740 LBL 40. REPAIRED IAW SRM 53-00-52 FIG 201.SDR DALA1014486311Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT BS 1700 RBL 40-77. REPAIRED IAW SRM 53-60-51 FIG 201.SDR DALA1014546308Connector · unsecureDURING LINE CHECK, MX FOUND EMERGENCY PATH LIGHTS AT ROWS 72 AND 73 INOPERATIVE. MX RESECURED THE LIGHT CONNECTIONS. OPS CHECK WAS GOOD.SDR DALA1014476311Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT BS540 RBL 98. REPAIRED IAW SRM 51-10-02, DWG 142U5210, AMM 20-51-01.SDR DALA1014406311Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT BS1700 LBL50-LBL77. REPAIRED IAW SRM 53-60-51, FIG 201.SDR DALA1014396311Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT BS540 RBL98. REPAIRED IAW SRM 51-10-02, DWG 142U5210 AND AMM 20-51-01.SDR DALA1014536308Connector · looseDURING LINE CHECK, MX FOUND EMERGENCY EXIT SIGN AT DOOR 2L INOPERATIVE. MX REPAIRED LOOSE CONNECTOR NEAR LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA1014436311Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON PANEL SUPPORT AT BS 880 LBL48 TO RBL20. REPAIRED IAW DWG SA35890-50.SDR DALA1014176304Light · inoperativeDURING LINE CHECK, MX FOUND 3 EMERGENCY PATH LIGHTS AT LAV DOOR 2R INOPERATIVE. MX REPLACED THE LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA1013886311Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK BETWEEN BS 2250 & 2260 RBL 11. REPAIRED IAW SRM 53-00-52.SDR DALA1013876311Intercostal · crackedDURING M-CHECK FOUND CRACK IN INTERCOSTAL UPPER ANGLE BETWEEN BS 1700-1720 RBL 65. REPAIRED IAW SRM 51-10-02, SRM 51-40-02 & DWG 65B08914.SDR DALA1013866311Bracket · crackedDURING M-CHECK FOUND CRACK IN FLOOR WEB JOINT BRACKET AT DOOR 1R. REPAIRED IAW SRM 51-10-02, DWG 65B08300, SRM 51-40-02.SDR DALA1013856311Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON UPPER DECK FLOOR SUPPORT BETWEEN BS 1000-1020 RBL 30. REPAIRED IAW DWG65B264449 AND SRM 51-10-02.SDR DALA1013306306Light · inoperativeOUTBOUND FLIGHT CREW FOUND THE LT ZONE B EMERGENCY PATH LIGHTS INOPERATIVE. MX REPAIRED THE FLOOR LIGHTS. OPS CHECK WAS GOOD.SDR DALA1012836315Light · inoperativeDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHTS AT ROWS 22-31 LT INOPERATIVE. MX REPLACED THE LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA1012646310Light · inoperativeDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHT BESIDE DOOR 4L JUMPSEAT INOPERATIVE. MX REPLACED THE FLOOR LIGHT. OPS CHECK WAS GOOD.SDR DALA1012266303Lamp · inoperativeDURING LAYOVER CHECK, MX FOUND THE FIRST 2 UPPER DECK EMERGENCY PATH LIGHTS INOPERATIVE. MX RECONNECTED, AND REPLACED, THE LAMPS. OPS CHECK WAS GOOD.SDR DALA1011426304Light · inoperativeDURING LAYOVER CHECK, MX FOUND THE EMERGENCY EXIT LIGHT AT DOOR 4L INOPERATIVE. MX REPLACED THE LIGHT ASSY. OPS CHECK WAS GOOD.SDR UALA2010052601813Element · contaminatedH21 THE COFFEE WARMER SMELLS LIKE SOMETHING IS BURNING WHEN TURNED ON. FOUND MELTED PLASTIC ON ELEMENT, CLEANED.SDR DALA1011136301Skin · corrodedDURING L-CHECK FOUND CORROSION ON FUSELAGE SKIN AT RT AFT WASTE VACUUM EXHAUST BS 2080- BS 2100. REPAIRED IAW SRM 51-10-02 AND DWG 65B04153.SDR DALA1011146301Skin · corrodedDURING L CHECK FOUND CORROSION IN SKIN AT LT BS 1240 LBL106. REPAIRED IAW ERA480448-14AD SECTION I. SECTION II REQUIRES INSP PRIOR TO ACCUMULATION OF 20,000 TOTAL ACFT CYCLES OR 100,000 FLIGHT HOURS WHICHEVER COMES FIRST. THEREAFTER REPEAT INSP EVERY 8000 CYCLSDR DALA1011116301Intercostal · damagedDURING L-CHECK FOUND OTBD INTERCOSTAL LOWER CHORD FASTENER HOLE OVERSIZED. REPLACED INTERCOSTAL LOWER CHORD IAW SRM 51-10-02 AND DWG 65B13386.SDR DALA1011106301Doubler · damagedDURING L-CHECK FOUND OVERSIZED HOLES ON FRAME DOUBLER AT OTBD BS 1265 BELOW FLOOR. REPAIRED IAW SRM 51-10-02 & DWG 624U0060.SDR DALA1011096301Frame · damagedDURING L-CHECK FOUND OVERSIZED FASTENER HOLE IN RT BS 1265 OTBD FRAME WEB JUST BELOW S27R OTBD CHORD AREA. REPAIRED IAW ERA 480443-14AD SECTION I. SECTION II REQUIRES PERMANENT REPAIR IN 24 MONTHS OR 2000 CYCLES AFTER 19 MAY 2010 WHICHEVER COMES FIRST.SDR DALA1011086301Bulkhead · damagedDURING L-CHECK FOUND 2 EA OVERSIZED HOLES ON RT BULKHEAD AFT INNER CHORD AT BS 2598. REPAIRED IAW ERA 480446-14AD.SDR DALA1011076301Bulkhead · damagedDURING L-CHECK FOUND 2 EA OVERSIZED HOLES ON LT BULKHEAD AFT INNER CHORD AT BS 2598. REPAIRED IAW ERA 480446-14AD.SDR DALA1011066301Intercostal · crackedDURING L-CHECK FOUND CRACK IN LT BS 1265 S26L INTERCOSTAL UPPER CHORD FRAME WEB HOLE A. REPAIRED IAW SRA 480444-14AD SECTION I. SECTION II REQUIRES REPETITIVE INSPECTIONS EVERY 1,000 CYCLES UNTIL PERMANENT REPAIR ACCOMPLISHED IAW SECTION III.SDR DALA1011056301Doubler · crackedDURING L-CHECK FOUND CRACK IN LT BS 1265 FRAME INTERCOSTAL DOUBLER CHORD HOLE A. REPLACED INTERCOSTAL DOUBLER IAW SRM 51-10-02 AND DWG 624U0060 AND ERA480444-14AD SECTION I. SECTION II REQUIRES REPETITIVE INSPECTIONS EVERY 1,000 CYCLES UNTIL PERMANENT REPAIR SDR DALA1010906301Attach Angle · crackedDURING L-CHECK FOUND FRAME ATTACH ANGLE CRACKED AT BS 480 S16R. FABRICATED ATTACH ANGLE AS IAW DWG65B08301 AND INSTALLED IAW SRM 51-10-02.SDR DALA1010856301Beam · damagedDURING L-CHECK AND DOOR NR 5 CREW REST SHEAR BEAM MODIFICATION FOUND SHORT EDGE MARGIN ON SHEAR WEB FASTENER HOLES. REPAIRED AND INSTALLED IAW ERA 480439-14AD.
Back to Boeing 747-451