Boeing 747-451
Service difficulty reports · 2,469
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR NWAA081216310Frame · crackedDURING "M" CHECK, FOUND CRACK IN FRAME RT WEB AT BS 1265 S26R. REPAIRED PER EA 63-212257 SECT I. REPETITIVE INSPECTIONS TO BE ACCOMPLISHED AT 2000 CYCLE INTERVALS PER SECT II UNTIL SECT III PERMANENT REPAIR IS ACCOMPLISHED.SDR NWAA081026307Battery Pack · inoperativeDURING OVERNIGHT CHECK, FOUND UPPER DECK FORWARD EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY M335 AND BATTERY. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR 2008UALA01545O-Ring · leakingOVERWATER CHECK FOUND DOOR 2L SLIDE BOTTLE PRESSURE OUT OF GREEN BAND. FOUND FAULTY O-RING. REPLACED SLIDE RAFT ASSEMBLY. AC OK FOR SERVICE.SDR NWAA080876306Connector · disconnectedDURING OVERNIGHT CHECK, FOUND ZONE B LEFT SIDE EMERGENCY LIGHTS WON'T ILLUMINATE. MAINTENANCE RECONNECTED ELECTRICAL CONNECTORS. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.
SDR NWAA080866306Connector · disconnectedDURING OVERNIGHT CHECK, ZONE D LEFT SIDE EMERGENCY LIGHTS WON'T ILLUMINATE. MAINTENANCE RECONNECTED ELECTRICAL CONNECTORS. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR NWAA080856309Power Supply · inoperativeDURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT LIGHTS ON RIGHT SIDE AFT WING TO BODY FAIRING INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.
SDR NWAA081596310Skin · damagedDURING "M" CHECK, FOUND SHORT EDGE MARGIN ON FUSELAGE SKIN FASTENER HOLES ABOVE DOOR 1 LT BS 460. REPAIRED PER EA 63-212523.SDR NWAA081586310Skin · damagedDURING "M" CHECK, FOUND SHORT EDGE MARGIN ON FUSELAGE SKIN FASTENER HOLES ABOVE DOOR 1 RT AT BS 460. REPAIRED PER EA 63-212524.SDR NWAA080736302Oven · contaminatedAFTER TAKEOFF, NR 2 MAIN TANK FORWARD PUMP MESSAGE AND LIGHT CAME ON, FOLLOWED BY RIGHT UTILITY BUSS LIGHT AND MESSAGE. PERFORMED FUEL PUMP PROCEDURE AS PER COM FIRST AND COMPLIED. THEN PERFORMED RIGHT UTILITY PROCEDURE AS PER COM AND COORDINATED WITH PURSERSDR NWAA081576310Seat Track · corrodedDURING "M" CHECK, FOUND SURFACE CORROSION ON SEAT TRACK AT BS 1090 RBL 98. REPAIRED PER EA 63-212530.SDR NWAA080716304Oven · fireFLIGHT ATTENDANT REPORTED A SMALL PIECE OF TAPE WAS STUCK IN THE OVEN AT DOOR 4 OVEN BELOW UNIT 3-57, AND HALON BOTTLE AT 4L WAS USED, BECAUSE OF A SMALL FIRE DID ERUPT. MAINTENANCE CONFIRMED SOURCE OF SMOKE WAS CATERING TAG/TAPE. REMOVED AND REPLACED OVEN, SDR NWAA080726311Oven · smokeDURING FLIGHT, FLIGHT ATTENDANT REPORTED THAT OVEN NR 1, IN GALLEY NR 2 HAD SMOKE COMING FROM UPPER RT OF SEAL. FIRE EXTINGUISHER WAS USED (REFERENCE LOG PAGE 2810194). FLIGHT CONTINUED ON, AND LANDING WAS UNEVENTFUL. MAINTENANCE FOUND OVEN CONTROL C/B POPPSDR NWAA08736302Electrical Sys · malfunctionedAFTER TAKE OFF NR 2 MAIN TANK FORWARD PUMP MSG AND LIGHT CAME ON FOLLOWED BY RT UTILITY BUS LIGHT AND MSG. PERFORMED FUEL PUMP PROCEDURE AS PER COM FIRST AND COMPLIED. THEN PERFORMED RT UTILITY PROCEDURE AS PER COM AND COORDINATED WITH PURSER. HER REPORT WASDR NWAA081606310Floorbeam · corrodedDURING "M" CHECK, FOUND CORROSION ON UPPER DECK FLOORBEAM AT BS 1040 RBL 42. REPAIRED PER EA 63-212526.SDR NWAA081226310Frame · crackedDURING "M" CHECK, FOUND CRACKS IN 4 FRAME WEB FASTENER HOLES COMMON TO TENSION TIE AREA AT BS 1220. REPAIRED PER EA 63-212263.SDR NWAA080776309Stringer · crackedDURING "M" CHECK, FOUND CRACKS IN STRINGER 10L AT BS 500. REPAIRED PER EA 63-212202.SDR NWAA080936309Stringer · crackedDURING M" CHECK FOUND CRACKS IN STRINGER 10L AT BS 480. REPAIRED PER EA 63-212201.SDR NWAA080926309Stringer · crackedDURING "M" CHECK, FOUND CRACKS IN STRINGER 10R AT BS 500. REPAIRED PER EA 63-212202.SDR NWAA080756309Stringer · crackedDURING "M" CHECK, FOUND CRACKS IN STRINGER 10R AT BS 460. REPAIRED PER EA 63-212199.SDR NWAA070766309Stringer · crackedDURING "M" CHECK, FOUND CRACKS IN STRINGER 10R AND STRINGER 10L AT BS 480. REPAIRED PER EA 63-212201.SDR NWAA070756309Stringer · crackedDURING "M" CHECK, FOUND CRACKS IN STRINGER 10R AT BS 460. REPAIRED PER EA 63-212199.SDR NWAA081396310Frame · crackedDURING "M" CHECK, FOUND CRACK IN FRAME WEB AT BS 2664 LT WL 310. REPAIRED PER EA 63-211713.SDR NWAA080816309Skin · crackedDURING "M" CHECK, FOUND CRACK IN FUSELAGE SKIN AT BS 1480 HOLE NR 11. REPAIRED PER EA 63-211896 SECT I. REPETITIVE INSPECTIONS TO BE ACCOMPLISHED EVERY 5,500 CYCLES THEREAFTER PER SECT II OF EA 63-211896.SDR 2008UALA00804Battery · dischargedSEVERAL EEL LAMPS INOP NEAR DOOR 4L. REPLACED BATTERY.SDR 2008UALA00803Lamp · inoperativeSEAT 49A SEAT EEL LIGHT INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00802Lamp · inoperativeSEAT 3A AFT EEL LIGHT INOP. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00801Lamp · inoperativeEEL CEILING LIGHT NEAR SEAT 23A INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR NWAA080436314Light · disconnectedDURING OVERNIGHT CHECK, FOUND EMERGENCY LIGHTS LT AISLE IN A ZONE INOP. MAINTENANCE RECONNECTED LIGHT ASSEMBLY. OPERATIONAL CHECKED OK AND AIRCRAFT WAS RETURNED TO SERVICE.SDR NWAA080426308Seat Track · corrodedDURING "M" CHECK, FOUND CORROSION ON SEAT TRACK AT BS 1080 AND BS 1210 RBL 33.99. REPAIRED PER EA 63-211709.SDR NWAA080396308Floorbeam · damagedDURING "M" CHECK, FOUND DOUBLE DRILLED FASTENER HOLES IN UPPER DECK FLOORBEAM AT BS 380 LBL 20 AND LBL 40. REPAIRED PER EA 63-211700.SDR NWAA080406308Floorbeam · damagedDURING "M" CHECK, FOUND DOUBLE DRILLED FASTENER HOLES IN UPPER DECK FLOORBEAM AT BS 400 LBL 20 AND LBL 40. REPAIRED PER EA 63-211701.SDR NWAA080316316Battery Pack · no testDURING LINE CHECK, FOUND RT UPPER DECK DOOR RIGHT BATTERY PACK FAILED TEST. REPLACED EMERGENCY POWER SYSTEM BATTERY PACK PER MM 52-23-14. FUNCTION CHECKED GOOD AND AIRCRAFT HAS RETURNED TO SERVICE.SDR NWAA080446308Failsafe · crackedDURING "M" CHECK, FOUND FAIL/SAFE CHORD FASTENER HOLES CRACKED AND WITH SHORT EDGE MARGIN AT BS 1140 RT AND LT. REPAIRED PER EA 63-211705.SDR NWAA080286311Control Unit · malfunctionedDURING CLIMB-OUT, SMOKE BEGAN POURING OUT OF THE FIRST OFFICER FRONT WINDSHIELD AREA. PERFORMED FIRE/SMOKE CHECKLIST, RETURNED TO MNL AND LANDING WAS UNEVENTFUL. AFTER LANDING FLIGHT ATTENDANT REPORTED SMELLING SMOKE AT DOOR 3 LEFT. MAINTENANCE REMOVED AND SDR NWAA080246312Web · damagedDURING "L" CHECK AND ACCOMPLISHMENT OF CREW REST MODIFICATION FOUND FLOOR WEB AT BS 2300 RBL 60-RBL 80 WITH SHORT EDGE MARGIN. REPAIRED PER EA 63-211481.SDR NWAA080176301Power Supply · inoperativeDURING OVERNIGHT CHECK, FOUND EXTERIOR EMERGENCY LIGHT BELOW DOOR 3R 3RD AND 4TH POSITIONS WILL NOT ILLUMINATE. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR NWAA080126301Circuit Card · damagedDURING TAKEOFF, APU FIRE WARNING ACTUATED. TAKEOFF WAS ABORTED AT LESS THAN 30 KNOTS. MAINTENANCE REMOVED AND REPLACED APU FIRE WARNING AND DETECTION CARDS. OPERATIONAL CHECKED GOOD, AIRCRAFT WAS RETURNED TO SERVICE.SDR NWAA080116301Terminal · damagedDURING CLIMB HAD 2 VERY BRIEF (1-2 SECOND) INTERMITTENT APU FIRE WARNINGS (EICAS MESSAGE AND MASTER LIGHT/BELL). AFTER CONSULTING WITH DISPATCH, MC AND FLEET TRAINING CAPTAIN APU FIRE HANDLE WAS PULLED BUT NOT TURNED. APU HAD BEEN SHUT DOWN NORMALLY PRIOR TOSDR NWAA080096316Power Supply · inoperativeDURING OVERNIGHT CHECK, FOUND ZONE E RIGHT SIDE PATH AND EXIT LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY. OPERATIONAL CHECKED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR 2008UALA00112Lamp · inoperativeDOOR 4 LEFT CEILING EMERGENCY LIGHT IS INOP. RELAMPED.SDR 2008UALA00111Lamp · inoperativeDOOR 3R FWD SILL & DOOR 4L BOTH SILLS EMERGENCY LIGHTS ARE INOPERATIVE. RELAMPED.SDR 2008UALA00110Lamp · inoperativeSEAT 3A FWD EMERGENCY LIGHT IS INOP. RELAMPED.SDR NWAA080016306Battery Pack · inoperativeDURING LINE CHECK, FOUND LT UPPER DECK EMERGENCY DOOR BATTERY PACK INOPERATIVE. REPLACED BATTERY PACK PER AMM 52-23-14.SDR NWAA074396308Web · puncturedDURING "M" CHECK, FOUND PUNCTURE IN WEB BELOW UPPER DECK FLOOR AT BS 940 RBL 34. REPAIRED PER EA 63-210899.SDR NWAA074146307Fitting · misinstalledDURING "M" CHECK, DURING ACCOMPLISHMENT OF DOOR 5 CREW REST MODIFICATION PER SB 747-53-2481 FOUND NEW FITTING AT BS 2040-2060 S11R-S12R WITH INSUFFICIENT EDGE MARGIN. REPAIRED PER EA 63-211300.SDR NWAA074106307Skin · crackedDURING "M" CHECK, FOUND CRACK IN SKIN FASTENER HOLES AND SHORT EDGE MARGIN ON FRAME AT BS 460 BETWEEN S14 AND S16. REPAIRED PER EA 63-211348.SDR NWAA074166307Sill · corrodedDURING "M" CHECK, FOUND CORROSION THE UNDERSIDE OF OUTBOARD FLANGE OF BULK CARGO LOWER MAIN SILL CHORD AT BS 1990. REPAIRED PER EA 63-211345.SDR NWAA074136307Frame · crackedDURING "M" CHECK, FOUND 3 HOLES WITH CRACKS AT BS 1180 FRAME TENSION TIE AREA. REPAIRED PER EA 63-211310.SDR NWAA074096307Shear Web · crackedDURING "M" CHECK, FOUND CRACK IN TENSION TIE AREA GUSSET AND SHEAR WEB AT BS 1120. REPAIRED PER EA 63-211013.SDR 2007UALA04965Wire · failedF-C REPORTED FIRE LOOP A 3 ENG. REPLACED WIRES W3506-503 AND 506 REF SWP 20-30-11, CHECKED ROUTING OF WIRES ON AC 8174 ENG 3-4, AC 8105 ENG NR 3, WIRES ROUTED DIFFERENTLY, REROUTED REPLACED WITH CORRECT CLAMPS. ACCOMP TEST REF MM26-11-00, OPS CHECK PASSED.
Back to Boeing 747-451