Boeing 747-451
Service difficulty reports · 2,469
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747451' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 0401086315Computer · odorDURING CRUISE, AN ELECTRICAL BURNING ODOR EMITTED FOLLOWED BY AN AUTO THROTTLE DISCONNECT CAUTION AND EICAS MESSAGE. THE SMELL DISSIPATED AND THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE AUTO THROTTLE TACHOMETER AND FLIGHT SDR 0400966301Power Supply · inoperativeDURING LINE CHECK, FOUND C-ZONE LEFT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY. OPERATIONAL CHECK GOOD.SDR 0400896305Wire · inoperativeDURING LINE CHECK, FOUND D-ZONE RIGHT AND E-ZONE LEFT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED WIRING AT 43J AND DOOR 4L. OPERATIONAL CHECK GOOD.SDR 0400886302Battery Pack · inoperativeDURING LINE CHECK, FOUND B-ZONE RIGHT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY PACK. OPERATIONAL CHECK GOOD.SDR 0400866309Socket · inoperativeDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21C-31C. REPLACED EMERGENCY LIGHT SOCKET ASSEMBLY AT SEAT 21C. OPERATIONAL CHECK GOOD.SDR 0400856309Socket · damagedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21C-31C. REPLACED EMERGENCY LIGHT SOCKET ASSEMBLY AT SEAT 21C. OPERATIONAL CHECK GOOD.SDR 0400796306Connector · inoperativeDURING LINE CHECK, FOUND ZONE-D LEFT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. RESEATED CONNECTOR. OPERATIONAL CHECK GOOD.SDR 0400916303Skin · crackedDURING L-CHECK FOUND CRACK IN FUSELAGE SKIN BETWEEN BS 2638 & BS 2658 WL 310. REPAIRED PER EA 63-194964.SDR 0400686316Connector · looseDURING LINE CHECK, FOUND LT SIDE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 51-65. SECURED LOOSE CONNECTION ON LIGHT SOCKET. OPERATIONAL CHECK GOOD.SDR 0400636313Power Supply · inoperativeDURING LINE CHECK, FOUND ZONE 'A' AND 'B' RIGHT SIDE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY. OPERATIONAL CHECK GOOD.SDR 0400606303Oven · smokeDURING FLIGHT, SMOKE EMITTED FROM THE NBR 2 OVEN IN GALLEY 2B. PULLED CIRCUIT BREAKERS AND AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN AND OVEN CONTROL CIRCUIT BREAKER. OPERATIONAL CHECK GOOD.SDR 0400576301Wire · damagedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 51-63JK. REPAIRED WIRING. OPERATIONAL CHECK GOOD.SDR 0400526306Bulb · inoperativeDURING LINE CHECK, FOUND THE RIGHT SIDE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21-41. REPLACED BULBS. OPERATIONAL CHECK GOOD.SDR 0400476307Wire · disconnectedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 51AB-62AB. RECONNECTED WIRE AT LIGHT ASSEMBLY. OPERATIONAL CHECK GOOD.SDR 0400426314Light · inoperativeDURING LINE CHECK, FOUND E-ZONE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPAIRED LEFT AND RIGHT FLOOR PATH EMERGENCY LIGHTS. OPERATIONAL CHECK GOOD.SDR 0400386309Power Supply · inoperativeDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE ON THE LEFT SIDE OF THE AIRCRAFT AND BETWEEN DOOR 2R AND 3R. REPLACED THE POWER SUPPLY FOR THE LIGHTS ON THE LEFT SIDE OF THE AIRCRAFT AND REPLACED A LIGHT ASSEMBLY TO REPAIR THE LIGHTS BETWEEN SDR 2004UALA00200Frame · corrodedAFT PIT FRAME 1920 T-CHORD EXFOLIATED AT RBL 57. MAJOR REPAIR ACCOMPLISHED. REPLACED CORRODED T-CHORD SECTION.SDR 2004UALA00199Bulkhead · dentedAFT PRESSURE BULKHEAD (STA 2360) HAS 2 EACH DENTS JUST BELOW WL 274.87 AT RBL 45 AND RBL 55. MAJOR REPAIR ACCOMPLISHED. INSTALLED 2 EACH REPAIR DOUBLERS.SDR 2004UALA00198Frame · corrodedBULK CARGO PIT FRAME STA 1920 UPPER CHORD AFT FLANGE IS EXFOLIATED UNDER NUT PLATES AT LBL 20, RBL 3, 6 & 12, LBL 20, RBL 3, RBL 6, RBL 12. MAJOR REPAIR ACCOMPLISHED. SPLICED IN NEW CHORD SECTION.SDR 0400316314Oven · smokeDURING FLIGHT, SMOKE EMITTED FROM THE NR 3 OVEN IN THE NR 3 GALLEY CAUSING THE CIRCUIT BREAKER TO TRIP. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN AND OVEN CONTROLLER. OPERATIONAL CHECK GOOD.SDR 0400296307Oven · odorDURING FLIGHT, A SMOKE ODOR EMITTED FROM THE RIGHT OVEN IN GALLEY 1B. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN AND THE OVEN CONTROL CIRCUIT BREAKER. OPERATIONAL CHECK GOOD.SDR 2004UALA00144Frame · dentedUPPER T-CHORD ON THE FRAME AT BS 1780, APPROX RBL 27 HAS A DENT IN THE HORIZONTAL FLANGE OF THE CHORD. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR ANGLE, SHIMS, INTERCOSTAL WEB & FILLERS.SDR 2004UALA00143Frame · dentedUPPER T-CHORD ON THE FRAME AT BS 720, APPROX RBL 15 HAS A DENT IN THE HORIZONTAL FLANGE OF THE CHORD. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR ANGLES, SHIMS AND FILLER.SDR 2004UALA00117Floorbeam · crackedUPPER DECK FLOORBEAM WEB IS DENTED AND CRACKED STA 380 RBL 14. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED WEB, TAPER SHIM & STIFFENER REPAIRS.SDR 2004UALA00116Door Frame · crackedLEFT NR 5 MED, FWD FRAME INBOARD WEB IS CRACKED AT LOWER DOOR HINGE AREA. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00115Door Frame · crackedRIGHT NR 5 MED, FWD FRAME INBOARD WEB CRACKED AT LOWER DOOR HINGE AREA. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2004UALA00114Floorbeam · damagedAFT CARGO COMPARTMENT FLOORBEAM AT STA 1820 BL0 DAMAGED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED T-CHORD REPAIR.SDR 0400206302Light · inoperativeDURING LINE CHECK, FOUND LEFT AND RIGHT SIDE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPAIRED LIGHTS. OPERATIONAL CHECK GOOD.SDR 0400236309Light · inoperativeDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21 TO 31. REPLACED LIGHT ASSEMBLY. OPERATIONAL CHECK GOOD.SDR 0400226315Connector · looseDURING LINE CHECK, FOUND B-ZONE FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. SECURED LOOSE CONNECTION ON LIGHT ASSEMBLY. OPERATIONAL CHECK GOOD.SDR 0400156302Light · inoperativeDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROW 21A TO DOOR 4L. REPAIRED LIGHT ASSEMBLY AT DOOR. OPERATIONAL CHECK GOOD.SDR 0400126303Light · disconnectedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21ABC-31ABC. RECONNECTED FLOOR PATH LIGHTS. OPERATIONAL CHECK GOOD.SDR 0400046301Battery Pack · inoperativeDURING LINE CHECK, FOUND C-ZONE LEFT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK GOOD.SDR 0400056302Wire · brokenDURING L-CHECK, FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21ABC - 31ABC. REPAIRED WIRING. OPERATIONAL CHECK GOOD.SDR 0302166315Controller · smokeDURING FLIGHT, SMOKE EMITTED FROM THE NR 1 GALLEY AS BOTH OVENS IN THE NR 1 GALLEY TURNED OFF AND ON TRIPPING THE NR 1 CIRCUIT BREAKER. THE CIRCUIT BREAKERS ON BOTH OVENS WERE PULLED AND THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLSDR 0302136315Smoke · detectedDURING FLIGHT, SMOKE EMITTED FROM THE NR 2 OVEN IN NR 1 GALLEY. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. RESET THE CIRCUIT BREAKER. OPERATIONAL CHECK GOOD.SDR 0302116314Lamp · inoperativeDURING L-CHECK, FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 10L-22L. RELAMPED EMERGENCY LIGHTS. OPERATIONAL CHECK GOOD.SDR 0302076310Wire · brokenDURING FLIGHT, AN ELECTRICAL BURNING SMELL EMITTED FROM THE COFFEEMAKERS IN GALLEY 3B. PULLED CIRCUIT BREAKERS AND THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPAIRED WIRE AND REPLACED TERMINAL FOR HOTPLATE IN GALLEY 3C POSITIONS 3-47SDR 0320046302Compressor · malfunctionedDURING CRUISE, AN ELECTRICAL BURNING SMELL EMITTED IN THE CABIN AND FLIGHT DECK. TURNED OFF CABIN VIDEO AND FOLLOWED COM PROCEDURES FOR ELECTRICAL SMOKE AND REMOVED POWER TO THE RECIRCULATION AND GASPER FANS. SMELL DISSIPATED AND AIRCRAFT CONTINUED TO DESTINSDR 0301926307Wire · damagedDURING LINE CHECK, FOUND LT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROW 1-14. REPAIRED WIRING. OPERATIONAL CHECK GOOD.SDR 0301796314Oven · burnedDURING FLIGHT, THE NR 2 OVEN IN GALLEY 1B EMITTED A BURNING ODOR. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED OVEN. OPERATIONAL CHECK GOOD.SDR 0301776310Light · odorDURING FLIGHT, AN ELECTRICAL BURNING ODOR EMITTED IN THE AREA OF 4B. THE AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPOSITIONED AND SECURED THE SLEEP LIGHT ABOVE DOOR 1L THAT WAS COMING IN CONTACT WITH THE PLASTIC SURROUND. OPERATIONAL CHESDR 0301726313Connector · inoperativeDURING LINE CHECK, FOUND ZONE (D) RT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. RECONNECTED ELECTRICAL PLUGS AT 52JHK. OPERATIONAL CHECK GOOD.SDR 0301706301Light · inoperativeDURING LINE CHECK FOUND ZONE "C" RIGHT FLOOR PATH EMERGENCY LIGHTS INOP. INSTALLED NEW LIGHT ASSEMBLY AT 29H. OPERATIONAL CHECK GOOD.SDR 0301666303Connector · inoperativeDURING LINE CHECK, FOUND ZONE 'B' LEFT AND ZONE 'E' RT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM THE DOOR TO ROW 12. REPAIRED ELECTRICAL CONNECTIONS LIGHT ASSEMBLIES. OPERATIONAL CHECK GOOD.SDR 0301646308Wire · disconnectedDURING LINE CHECK, FOUND LEFT FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM THE DOOR TO ROW 12. RECONNECTED LIGHT ASSEMBLY. OPERATIONAL CHECK GOOD.SDR 0301716303Control Panel · inoperativeDURING TAKEOFF, RECEIVED (SMOKE DR5 REST) MESSAGE ACCOMPANIED WITH AN EICAS AND MASTER CAUTION. AIRCRAFT ABORTED TAKEOFF AT 75 KNOTS AND RETURNED TO THE GATE WITHOUT FURTHER INCIDENT. REPLACED THE P24 PANEL AND 4 CREW REST SMOKE DETECTORS. OPERATIONAL CHECK GSDR 0301566302Wire · disconnectedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE FROM ROWS 21-31. RECONNECTED WIRES. OPERATIONAL CHECK GOOD.SDR 0301536301Wire · disconnectedDURING LINE CHECK, FOUND 'D' ZONE RIGHT AND UPPER DECK FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. RECONNECTED WIRES. OPERATIONAL CHECK GOOD.SDR 0301466305Wire · damagedDURING LINE CHECK, FOUND FLOOR PATH EMERGENCY LIGHTS INOPERATIVE AFT OF DOOR 1R. REPAIRED WIRE. OPERATIONAL CHECK GOOD.
Back to Boeing 747-451