Boeing 757-21B
Service difficulty reports · 1,078
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75721B' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75721B' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201012264752Girt Bar · bindingLEFT FWD ENTRANCE DOOR (L1) SLIDE LIGHT - INOP. RELEASED FOR SERVICE IAW MEL: 52-11-01-A CATEGORY: B EXPIRATION: 27DEC10 "MEL 52-11-01-A: L1 DOOR SLIDE - INOP (INOP OR MISSING)." THE GIRT BAR IS NOT FULLY ENGAGING THE DOOR THRESHOLD BRACKET. IT APPEARS THSDR FDEA201011264492Slide · looseL1 DOOR ESCAPE HAS DROPPED DOWN AND APPEARS TO BE UNATTACHED. RELEASED FOR SERVICE IAW MEL: 52-11-01-A. "MEL 52-11-01-A: L1 DOOR SLIDE- INOP (IDENTIFY INOP OR MISSING)." SAFELY PLACED SLIDE IN THE HSG. FOUND THAT BOTH UPPER STRAP CLASPS WOULD NOT TIGHTLY SESDR ANCF2010060800062Governor · malfunctionedPILOT REPORT: RTO DUE TO LEFT ENGINE EPR WAS 1.27 WITH THE THRUST LEVER AT FULL FWD POSITION, EPR TARGET WAS 1.61 WITH 50C FLEX TEMP. IAW B757 MM 73-21-01 PG 401-420 REMOVED AND REPLACED LEFT ENGINE FUEL FLOW GOVERNOR. IAW B757 AMM 71-00-00/501 PERFORMED LTSDR FDEA200912024322Keelbeam · corrodedFWD CARGO BS 780 TO 800 STR 28R CORRODED. CORRODED AREA REPAIRED IAW EA F-5310-133438 (CORROSION REPAIR ON KEEL BEAM CHORD BETWEEN BS 779-883 AND STRINGER 28R). REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR FDEA200912024321Panel · corrodedAFT CARGO RT SIDE PANEL FROM STA 1440-1640 FOUND WITH SEVERAL AREA CORRODED AS MARKED. CORRODED SIDE PANEL FROM STA 1440 TO STA 1640 REMOVED AND REPLACED IAW F-5320-133446 (FABRICATION OF DECK AND REPAIR OF SIDE WALL PANELS). REPAIR IS CLASSIFIED AS MINOR IASDR FDEA200912024320Support Angle · corrodedFWD CARGO BS 840 STR 22R TO 26R SIDEWALL TO BULKHEAD SUPPORT ANGLE CORRODED. CORRODED ANGLE AT BS 840 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014319Floor Panel · corrodedAFT CARGO NR 4 FLOOR PANEL (STA 1510 - STA 1640) FOUND WITH SEVERAL AREA CORRODED AS MARKED. CORRODED PANEL BETWEEN STA 1510 AND STA 1640 REMOVED AND REPLACED IAW EA F-5320-133446 ( FABRICATION OF DECK AND REPAIR OF SIDE WALL PANELS). REPAIR IS CLASSIFIED ASSDR FDEA200912014318Floor Panel · corrodedAFT CARGO NR 3 FLOOR PANEL (STA 1470-STA 1510) FOUND WITH SEVERAL AREA CORRODED AS MARKED. CORRODED FLOOR PANEL BETWEEN STA 1470 AND STA 1510 REMOVED AND REPLACED IAW EA F-5330-133446 (FABRICATION OF DECK AND REPAIR OF SIDE WALL PANELS). REPAIR IS CLASSIFIEDSDR FDEA200912014317Floor Panel · corrodedAFT CARGO NR 2 FLOOR PANEL (STA 1330-STA 1470) FOUND WITH SEVERAL AREA CORRODED AS MARKED. CORRODED FLOOR PANEL BETWEEN STA 1330 AND STA 1470 REMOVED AND REPLACED IAW EO 5320-133446 (FABRICATION OF DECK AND REPAIR OF SIDEWALL PANELS). REPAIR IS CLASSIFIED ASSDR FDEA200912014316Floor Panel · corrodedAFT CARGO NR 1 FLOOR PANEL (STA 1200-STA 1330) FOUND SEVERAL AREA CORRODED AS MARKED. CORRODED FLOOR PANEL BETWEEN STA 1200 AND STA 1330 REMOVED AND REPLACED IAW EO F-2550-7-5000 PT 3. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014315Floor Splice · corrodedFWD CARGO COMPT - FLOOR PLATE SPLICE STRAP AT BS 750 FOUND CORRODED. CORRODED STRAP AT BS 750 REMOVED AND REPLACED IAW SRM 51-40-02. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014314Floor Splice · corrodedFWD CARGO COMPT - FLOOR PLATE SPLICE STRAP AT BS 550 FOUND CORRODED. CORRODED STRAP AT BS 550 REMOVED AND REPLACED IAW SRM 51-40-02. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014313Floor Splice · corrodedFWD CARGO COMPT - FLOOR PLATE SPLICE STRAP AT BS 654 FOUND CORRODED. CORRODED SPLICE STRAP AT BS 654 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014312Cargo Track · corrodedAFT CARGO COMPARTMENT BETWEEN STA 1380 AND 1620 TIE DOWN FITTINGS CORRODED AROUND NUTPLATES AND UPPER SURFACE. CORRODED TIE DOWN FITTINGS BETWEEN STA 1380 AND STA 1620 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-SDR FDEA200912014311Strap · corrodedFWD CARGO COMPT - RT SIDEWALL LWR RETAINING STRAP AT BS 540 TO 560 FOUND CORRODED. CORRODED STRAP FROM BS 540 TO 560 REMOVED AND REPLACED AMM 20-11-00 REV 5. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014310Cargo Track · corrodedAFT CARGO COMPARTMENT TIE DOWN FITTINGS HAVE CORROSION AROUND NUTPLATES AND UPPER SURFACE CORROSION FROM STA 1220 TO 1380. TIE DOWN FITTING FROM STA 1220 TO STA 1380 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-10SDR FDEA200912014309Floor Panel · corrodedFWD CARGO NR 1 FLOOR PANEL (STA 508-STA 550) FOUND WITH SEVERAL AREA CORRODED AND QTY 1 EXISTING REPAIR AS MARKED. CORRODED FLOOR PANEL FROM STA 508 TO STA 550 REMOVED AND REPLACED. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014308Floor Panel · corrodedFWD CARGO NR 2 FLOOR PANEL (STA 550-STA 653) FOUND WITH SEVERAL AREA CORRODED AS MARKED. CORRODED NR 2 FLOOR PANEL FROM STA 550 TO STA 653 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MIINOR IAW GMM 6-2-100.SDR FDEA200912014307Intercostal · crackedINTERCOSTAL FOUND CRACK BETWEEN STA 440-460, STR 23L TO 22L. CRACKED INTERCOSTAL BETWEEN STA 440 AND STA 460 REMOVED AND REPLACED UNDER PTF MOD WORK CARD 11850370ZSR01 (DELETION AND SALVAGE MODULE) AND CARD 118150066FL1R02 (INSTALLATION MODULE). REPAIR IS CSDR FDEA200912014306Fitting · corrodedAFT CARGO DOOR SILL FITTING NR 4 CORRODED AT STA 1435 CORRODED FITTING AT STA 1435. REMOVED AND REPLACED IAW AMM 20-11-00 REV 5. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200912014305Panel · corrodedFWD CARGO OTBD SIDE PANEL FOUND WITH EXISTING REPAIR AT STA 660 AS MARKED. RT SIDE PANEL AT STA 660 FOUND WITH CORROSION. PANEL REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304304Strap · corrodedAFT CARGO COMPARTMENT DOOR SILL NUT PLATE RETENTION STRAP CORRODED ENTIRE LENGTH FROM STA 1380-1440, RBL 24. CORRODED NUTPLATE RETENTION STRAP FROM STA 1380 TO STA 1440 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-1SDR FDEA200911304303Panel · corrodedAFT CARGO COMPARTMENT TRANSITION PANEL UPPER AND LOWER SURFACES CORRODED AT STA 1410-1453 LBL 22. CORRODED TRANSITION PANEL BETWEEN STA 1410 AND STA 1453 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304302Torque Box · corrodedTORQUE BOX ASSY, ELEVATOR CONTROL SYSTEM LOWER ARM AFT AREA FOUND CORROSION. CORROSION ON TORQUE BOX ASSY REPAIRED IAW EA F-2710-133433 (ELEVATOR QUADRANT ASSY TORQUE TUBE AND TOQUE BORE CORROSION REPAIR). REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304301Cargo Track · corrodedAFT CARGO COMPARTMENT BETWEEN STATION 1380 AND 1620 HAS CORRODED TIEDOWNS AROUND NUTPLATES AND UPPER SURFACE AT STRINGER 26L. CORRODED TIE-DOWN FITTINGS FROM STA 1380 TO STA 1620 REMOVED AND REPLACED IAW SRM 51-40-02 REV.98. REPAIR IS CLASSIFIED AS MINOR IAW SDR FDEA200911304300Cargo Track · corrodedAFT CARGO COMPT TIE DOWN FITTING HAS CORROSION AROUND NUTPLATES AND UPPER SURFACE FROM STA 1220 TO 1380 LBL 23". CORRODED TIE-DOWN FITTING FROM STA 1220 TO STA 1380 REMOVED AND REPLACED IAW SERM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CSDR FDEA200911304299Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE AT STA 1610, LBL 7 CORRODED. CORRODED SUPPORT FROM STA 1500 TO STA 1640, LBL 7, REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304298Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE LWR SURFACE CORRODED AT STA 1580-1600, LBL 12. CORRODED SUPPORT ANGLE FROM STA 1500 TO STA 1640 REMOVED AND REPLACED IAW SRM 51-40-02 REV.98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304297Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE UPPER/ LOWER SURFACES CORRODED AT STA 1560-1580, RBL 12. CORRODED FLOOR SUPPORT FROM STA 1560 TO STA 1580 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304296Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE UPPER/LOWER SURFACES CORRODED AT STA 1540-1560, RBL 7. CORRODED SUPPORT ANGLE FROM STA 1500 TO STA 1640 , RBL 7, REMOVED AND REPLACED IAW SRM 51-40-02 REV.98, REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200911304295Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE HAS SEVERAL CORRODED NUTPLATES FROM STA 1460-1480, RBL 9.5. CORRODED SUPPORT FROM STA 1445 TO STA 1500, RBL 10.5, REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304294Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE HAS SEVERAL CORRODED NUT PLATES FROM STA 1460-1480, RBL 5. CORRODED FLOOR SUPPORT FROM STA 1445 TO STA 1500 REMVOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304293Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE HAS SEVERAL CORRODED NUTPLATES FROM STA 1460-1480, BL 0. CORRODED FLOOR SUPPORT FROM STA 1445 TO STA 1500 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304292Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE HAS CORRODED NUT PLATE AT STA 1470, LBL 5. CORRODED SUPPORT ANGLE FROM STA 1445 TO STA 1500 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304291Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE HAS SEVERAL CORRODED NUTPLATES FROM STA 1460-1480, LBL 9.5. CORRODED SUPPORT ANGLE FROM STA 1460 TO STA 1480, LBL 9.5 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304290Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE HAS SEVERAL CORRODED NUT PLATES FROM STA 1460-1480 , LBL 13.5. CORRODED SUPPORT FROM STA 1460 TO STA 1480 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304289Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE LOWER SURFACE CORRODED AT STA 1460-1480, LBL 16.10. CORRODED SUPPORT ANGLE FROM STA 1460 TO STA 1480 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304288Floor Support · corrodedFLOOR SUPPORT ANGLE AT STA 1637 LBL 3 CORRODED AT LWR SURFACE AT NUTPLATE. CORRODED FLOOR SUPPORT AT STA 1637 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304287Floor Support · crackedFLOOR SUPPORT ANGLE AT STA 1640 RBL 3 CRACKED. CRACKED SUPPORT ANGLE AT STA 1640 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304286Floor Support · corrodedAFT CARGO BS 1342 TO 1445 RBL 3, 8, 12, 16 FLOOR SUPPORTS CORRODED. CORRODED FLOOR SUPPORTS FROM BS 1342 TO BS 1445, RBL 3, 8, 12, 16 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304285Floor Support · corrodedAFT CARGO BS 1342 TO 1445, LBL 3, 8, 12, 16 SUPPORTS CORRODED. CORRODED SUPPORTS FROM BS 1342 TO BS 1445 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200911304284Floor Support · corrodedFWD CARGO BS 630 TO 710 RBL3, FLOOR SUPPORT CORRODED. CORRODED SUPPORT FROM BS 630 TO BS 710, RBL 3, REPAIRED IAW SRM 51-70-12 FIG 1 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304283Floor Support · corrodedFWD CARGO BS 630 TO 710 LBL 3, FLOOR SUPPORT CORRODED. CORRODED FLOOR SUPPORT FROM BS 630 TO BS 710 REMOVED AND REPLACED IAW SRM 51-40-02 REV. 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200911304282Panel · corrodedFWD CARGO BS 770 TO 840 RT SIDE TRANSITION PANEL CORRODED. CORRODED TRANSITION PANEL FROM BS 770 TO BS 840 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MNOR IAW GMM 6-2-100.SDR FDEA200911304281Panel · corrodedFWD CARGO BS 560 TO 630 RT SIDE TRANSITION PANEL CORRODED. CORRODED TRANSITION PANEL FROM BS 560 TO BS 630 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200911304280Floor Support · corrodedFWD CARGO BS 508 TO B30 RBL 3, FLOOR SUPPORTS CORRODED. CORRODED FLOOR SUPPORT FROM STA 508 TO STA 630 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED IAW GMM 6-2-100 CRITERIA.SDR FDEA200911304279Floor Support · corrodedFWD CARGO STA 508 TO STA 630 LBL 3 FLOOR SUPPORT CORRODED. STA 508 TO STA 630 LBL 3 CORRODED FLOOR SUPPORT REPAIR CARRIED OUT IAW SRM 51-70-012 FIG 1, REV 98. FLOOR SUPPORT CORROSION REMOVED, REMAINED THICKNESS 0.030", ORIGINAL THICKNESS 0.063" AND MATERIAL SDR FDEA200911304278Panel · corrodedFWD CARGO LT SIDE PANEL AT STA 660 TO STA 845 FOUND WITH SEVERAL AREA CORRODED AS MARKED. CORRODED LT SIDE PANEL AT STA 660 TO STA 845 FOUND EXCEEDED LIMIT IAW SRM 53-00-53 FIG 101 REV 98 SIDE PANEL. REMOVED AND REPLACED WITH NEW SIDE PANEL 143N5366Y76 ANDSDR FDEA200911304277Panel · corrodedFWD CARGO LT SIDE PANEL FROM STA 510 TO STA 585 FOUND SEVERAL AREA CORRODED AS MARKED. STA 510 TO STA 585, LT SIDE CORRODED PANEL REMOVED AND REPLACED WITH NEW SIDE PANEL 143N5366Y83 AS PER SRM 51-4-02 REV 98. SIDE PANEL FOUND CORRODED EXCEEDED LIMITS IAW SDR FDEA200911304249Panel · corrodedAFT CARGO COMPARTMENT TRANSITION PANEL CORRODED AT STA 1405, RBL 22. CORRODED TRANSITION PANEL AT STA 1405 REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.
Back to Boeing 757-21B