What was found
FWD CARGO STA 508 TO STA 630 LBL 3 FLOOR SUPPORT CORRODED. STA 508 TO STA 630 LBL 3 CORRODED FLOOR SUPPORT REPAIR CARRIED OUT IAW SRM 51-70-012 FIG 1, REV 98. FLOOR SUPPORT CORROSION REMOVED, REMAINED THICKNESS 0.030", ORIGINAL THICKNESS 0.063" AND MATERIAL REMOVED 0.033" FOUND EXCEEDED LIMIT IAW SRM 53-00-53 FIG 101, REV 98. CORRODED FLOOR SUPPORT REMOVED AND REPLACED IAW SRM 51-40-02 REV 98. REPAIR IS CLASSIFIED AS MINOR REPAIR IAW GMM 6-2-100 CRITERIA.