Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2008121506874Light · inoperativeEMERGENCY EGRESS LIGHT AT ROW 15A IS INOP. REPLACED LIGHT AND OPS CHECK GOOD.SDR UALA2008121506897Shutoff Valve · faultyLEFT ENGINE BLEED VALVE WILL NOT CLOSE WHEN SWITCH IS MOVED TO THE OFF POSITION. DUCT PRESS RISES WHEN THROTTLES WERE ADVANCED. REMOVED AND REPLACED PRSOV. OP CHECKS AND LEAK CHECKS GOOD.SDR UALA2008121506872Mechanism · out of adjustDOOR 1L EMERGENCY POWER TRIGGER MECHANISM OUT OF ADJUSTMENT. ACCOMP ADJUSTMENT AND OPS CHECKS GOOD.SDR UALA2008121106853Lamp · inoperativeNR 4 RT MAIN ENTRY DOOR (EXT) EMERGENCY EXIT LIGHT INOP. RELAMPED EMERGENCY LIGHT. OPERATES NORMAL.SDR UALA2008121106854Skin · dentedEXTERNAL FUSELAGE STA 1680 BETWEEN STR 27L AND 28L DENTED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR.SDR UALA2008120806781Lanyard · unsecureTHE R3 DOOR SLIDE PACK HAS LANYARD STICKING OUT OF THE BOTTOM OF THE SLIDE PACK DOOR. SLIDE PACK UNDISTURBED. DOOR ARMS AND DISARMS NORMALLY. SECURED D-RING STRAP.SDR UALA2008120806784Start Valve · malfunctionedL ENG STARTER EICAS WHEN START SELECTOR SWITCH PLACED INTO GND. REPLACED START VALVE AND CHECK OKAY.SDR UALA2008120806782Fuel Control · malfunctionedLEFT ENGINE SHUTDOWN BY ITSELF AFTER START. REPLACED FUEL CONTROL UNIT.SDR UALA2008120806780Bearing · missingRT WING T/E FLAP AFT FLAP INBOARD SUPPORT TRACK LOWER AFT BEARINGS ATTACHED ON T/E FLAP REAR SPAR ARE MISSING AND THRU BOLT IS SHEARED OFF. REPLACED ROLLER SUPPORT ASSY.SDR UALA2008120506765Anti-Ice Valve · faultyEICAS MSG WING ANTI-ICE DISPLAYED. REPLACED ANTI-ICE VALVE RIGHT WING. ANTI-ICE VALVE SENSE LINE FITTING AND B-NUT STRIPPED AT LINE TO VALVE. NEEDS NEW LINE AND FITTING. BOTH ENDS OF SENSE LINE STRIPPED NEED NEW LINE AND BOTH UNIONS REPLACED. REPLACED LINSDR UALA2008120806776Structure · corrodedG4B GALLEY PRESSURE DECK STA 1682-1720, RBL 53 UNDER WATER DRAIN CHANNEL HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION, TRIMMED OUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR.SDR UALA2008120806775Door Frame · dentedFWD CARGO DOOR DENTED, LOWER AFT INSIDE CORNER. MAJOR REPAIR ACCOMPLISHED. REPLACED LWR AFT CORNER FRAME P/N 143N6618-5.SDR UALA2008120806774Door Frame · gougedFWD CARGO DOOR LOWER FWD FRAME CORNER GOUGED. MAJOR REPAIR ACCOMPLISHED. REMOVED CORNER SECTION OF FRAME AND INSTALLED NEW CORNER FRAME P/N 143N6618-6.SDR UALA2008120506760Fitting · missingMED 2 RT EMER TRIGGER MECH. MISSING ADJUSTMENT SAFETY CLIP. REPLACED SAFETY CLIP.SDR UALA2008120506759Mechanism · wornMED 1 RT EMER. TRIGGER MECH. WORN. REPLACED EMERGENCY TRIGGER.SDR UALA2008120406757Oil System · malfunctionedNR 2 ENGINE OIL PRESSURE LOSS. FLIGHT DIVERTED.SDR UALA2008120406751Structure · damagedL-2 DOOR REQUIRES DOUBLER REPAIR AT UPPER HINGE CUTOUT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED A REPAIR DOUBLER.SDR UALA2008120406750Frame · dentedFWD PIT FRAME DENTED STA 520 AT STR 24L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED I/B FLANGE AND INSTALLED J-ANGLE REPAIR.SDR UALA2008120406742Ballast · inoperativeINOP OVERWING LT EXIT LIGHT (INTERIOR). REPLACED BALLAST.SDR UALA2008120306733Frame · dentedFWD PIT FRAME DENTED AT BS 620 AND STR 24L. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FLANGE AND FABRICATED A REPAIR ANGLE AND INSTALLED.SDR UALA2008120306732Frame · dentedDENT IN FUSELAGE FRAME AT STA 1420, STR 26L. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FLANGE AND FABRICATED A J-ANGLE REPAIR.SDR UALA2008120306731Frame · dentedAFT PIT AT STA 1480, STR 26L FRAME DENTED AT INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FLANGE AND FABRICATED A J-ANGLE REPAIR AND INSTALLED.SDR UALA2008120306739Computer · faultyACMS SYSTEM FAULTY. ACCMP FLIGHT DATA ACQUISITION MGMT UNIT SOFTWARE UPLOAD.SDR UALA2008120106713Idg · faultyLT GEN CAME OFF LINE 2 TIMES, SPOKE TO SAM, DURING RUN UP IS WHEN GEN CAME OFF AT =40% N1. REPLACED NR 1 IDG.SDR UALA2008120106684Cable · out of adjustLT OFF WING BACK UP CABLE DIMENSION FROM SUPPORT SHROUD TO THE BACK UP CABLE THREADS FOUND OUT OF LIMITS. ADJUSTED THE SUPPORT SHROUD TO CABLE BACK UP CABLE THREAD DIMENSION NOW AT .060.SDR UALA2008120106682Light · unsecureEMERGENCY LIGHTING STRIP STICKING UP FROM FLOOR AT SEATS 13ABC. RESECURED EEL LIGHTING STRIP, OPS CHECKS OK.SDR UALA2008120106681Girt Bar · lack of lubeDOOR 1L DIFFICULT TO ARM. LEVER VERY TIGHT. CHECKED GIRT BAR AREA AND LUBED, CK'D GOOD.SDR UALA2008112606679Connector · faultedNR 1 L FIRE BOTTLE WILL NOT TEST. ACCOMPLISHED LEFT ENGINE EXTINGUISHER BOTTLE SQUIB TEST CIRCUIT TEST. RANG OUT WIRING FROM M32 SQUIB TEST PANEL TO LEFT SQUIB CONNECTOR D2188 ON BOTTLE 1, B17. CHECKED GOOD. CONNECTOR D2188 ON SQUIB CHECKED GOOD. REPLACEDSDR UALA2008112506672Module · no testTRAILING EDGE FLAP ASYMMETRY ON FINAL APP BETWEEN 15 & 20. FOUND THE NR 8 JACKSCREW STOP OUT OF RIG. PERFORMED A COMPLETE RE-RIG OF RT OUTBOARD FLAP. ACP FIM 27-51-60, FAILED DEPRESS MODULE OPS CHECK FOR UNCOMMANDED MOTION. REPLACED MODULE MR 27597 ON CARD 3SDR UALA2008112506661Controller · faultyAPU INOP. CAUSE WAS FOUND TO BE THE APU CONTROLLER. THIS PART HAS BEEN CHRONIC AND HAS A LONG HISTORY OF NFF.SDR UALA2008112406640Sign · out of positionEXIT SIGN FELL OFF BY 2L. INSTALLED EMERGENCY EXIT SIGN DOOR 2L.SDR UALA2008112406639Lanyard · out of positionDOOR 1R, HAS LANYARD HANGING FROM DOOR SLIDE. RE-INSTALLED LANYARD INTO SLIDE PACK.SDR UALA2008112406637Battery · faultyFLASHLIGHT FWD GALLEY NEEDS BATTERIES REPLACED. REPLACED BATTERY AND RESEALED.SDR UALA2008112406626Connector · misinstalledCONNECTOR ON T/E BYPASS VALVE V105 ALSO HAS INSULATOR DAMAGE FROM CONNECTOR NOT BEING INSTALLED PROPERLY. REPLACED VALVE ASSY. ALSO FOUND T/E FLAP BYPASS VALVE CONNECTOR D1716 NOT CONNECTED AT LT WHEEL WELL WHILE DOING OPS TEST FOR FLAP AND SLAT ALTERNATE DRSDR UALA2008112406621Skin · dentedFUSELAGE SKIN DENT STA 760, AT STR 17L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR.SDR UALA2008112406620Floorbeam · corrodedMAIN CABIN FLOORBEAM STA 1640, RBL 57 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF T-CAP, RBL 0 TO RBL 64. FAB NEW SECTION AND SPLICES.SDR UALA2008112406618Frame · dentedAFT PIT AT STA 1560, STR 26R, FRAME DENTED AT INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2008112106608Oxygen Mask · defectivePILOTS O2 MASK HAS DEFECTIVE AIRFLOW. REPLACED MASK & OP CHECKS OK.SDR UALA2008112106607Engine · bird ingestionRTFL DUE TO BIRD STRIKE. PERFORM NR 1 ENG BURNOUT PROCEDURE DUE TO ODOR IN CABIN (BIRD STRIKE NR 1 ENGINE). REMOVE NR 1 ENGINE DUE TO LPC STG 1 BOOSTER DAMAGE AND LINER SEPARATION.SDR UALA2008112106609Anti-Ice Valve · faultyWHEN LT ENG ANTI-ICE SWITCHED ON, VALVE INTRANSIT LIGHT FAILED TO COME ON BRIEFLY. REPLACED TAI VALVE. TESTED, WORKS FINE.SDR UALA2008112106606Frame · dentedAFT PIT AT STA 1500, STR 26L FRAME DENTED AT INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME REPAIR.SDR UALA2008112006591Frame · dentedAFT PIT AT STA 1520, STR 26L FRAME DENTED AT INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED FRAME SECTION AND INSTALLED DOUBLER REPAIR.SDR UALA2008112006584Wire · exposedCREW REPORT: EXPOSED WIRE AT SEAT 5A THIS IS A LIVE ELECTRICAL WIRE.SDR UALA2008112006582Duct · damagedPRESSURIZATION PROBLEM. RTFL. REPLACED BLOWN FLEX DUCT.SDR UALA2008112406614Pressure Panel · damagedAFT PRESSURE DECK BS 1681.8 AT RBL 42" AND RBL 52" HAS CORROSION DAMAGE. MAJOR REPAIR ACCOMPLISHED. REMOVED PREVIOUSLY INSTALLED REPAIR DOUBLER-TRIPLER. FABRICATED A NEW REPAIR DOUBLER.SDR UALA2008112006593Oxygen System · faultyCAPT O2 RESET - TEST SLIDE STICKS IN TEST POSITION. REPLACED O2 BOX PER MM 35-11-51.SDR UALA2008112006590Switch · failedTHE O2 SYSTEM FAILS ALTITUDE SWITCH, OPS CHECKS. REPLACED ALTITUDE PRESSURE SWITCH, OPS CHECKS GOOD.SDR UALA2008112006588Light · inoperativeLAV K FLOOR PATH LIGHT STRIP INOP. REPLACED FLOOR PATH LIGHT STRIP.SDR UALA2008112006586Wire · chafedWIRE BUNDLES AND COAX HAVE CHAFING, 1 EA BROKEN WIRE, NOT SECURED UNDER MAIN CABIN FLOOR STA 996 TO 1180, LBL 48. SECURED WIRE BUNDLES AND COAX UNDER MAIN CABIN FLOOR AT BS 996-1180, LBL 48 PER BSWPM 20-10-42. OPS CHECK OF HYDRAULIC RESERVOIR TEMP GOOD AND OSDR UALA2008112006585Frame · dentedAFT PIT FRAME DENTED STA 1520, RBL 8 TO RBL 9. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED J-ANGLE DOUBLER REPAIR.
Back to Boeing 757-222