SDR 2008UALA06233Oxygen Mask · leakingCAPT O2 MASK HAS CONSTANT FLOW WHEN IN USE. FOUND MASK LEAKING. REPLACED CAPT OXYGEN MASK. LEAK & OPS TEST OKAY.SDR 2008UALA06232Gate · corrodedDOOR 4R LWR GATE CORRODED AND MISSING PIECES. REPLACED LOWER GATE.SDR 2008UALA06240Indicator · no testSTANDBY ENGINE INDICATOR (SEI) WILL NOT BITE TEST. REPLACED SEI. OP CHECKS NORMAL.SDR 2008UALA06230Unknown · odorBURNING ODOR REPORTED. RFTL.SDR 2008UALA06229Frame · dentedFWD PIT AT STA 600, STR 23L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR 2008UALA06228Frame · dentedAFT CARGO COMPT FRAME AT BS 1580 AND STR 26R HAS 2 DENTS AT FRAME INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED FRAME SECTION AND INSTALLED DOUBLER REPAIR.SDR 2008UALA06227Frame · dentedAFT CARGO COMPT, FRAME AT BS 1480 LT AND STR 26L HAS A DENT AT INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR UALA2008111306188Power Supply · dischargedEMERGENCY LIGHT PROBLEM DISCOVERED ON 1SV. REPLACED POWER SUPPLY M10818, M10817 AND BATTERY PACKS FOR BOTH POWER SUPPLIES.SDR UALA2008111306195Slat · damagedNR 1 AND NR 2 LEADING EDGE SLAT AND UNDER WING PANEL 521MB DAMAGED BY AIR STAIR. SLATS REPLACED.SDR 2008UALA06199Slide · low pressureDOOR 1L SLIDE PRESSURE NEEDLE INDICATES LOW. PRESSURE BELOW DISPATCH LIMITS. REPLACED SLIDE ASSEMBLY.SDR 2008UALA06195Slat · damagedNR 1 AND NR 2 LEADING EDGE SLAT DAMAGE.SDR 2008UALA06188Power Supply · faultyEMERGENCY LIGHT PROBLEM DISCOVERED ON 1SV. REPLACED POWER SUPPLY M10818, M10817 AND BATTERY PACKS FOR BOTH POWER SUPPLIES.SDR UALA2008111306209Light · inoperativeDOOR 4R EMERGENCY LIGHT OUT - OUTSIDE. RELAMPED EMERGENCY EXIT LIGHT AT R4 DOOR AND OPS CHECKED GOOD.SDR UALA2008111306184Light · shortedDOOR 2R AND PARTS OF AFT CABIN EMER EXIT LIGHTS ARE ON. REPLACED SHORTED BULB FOR DOOR 2 RIGHT EXTERNAL EMERGENCY LIGHT AND REPLACED INOP BATTERY PACK AT STA LOC 1240 ITEM M10699 REF WDM 33-51-14 PG 1 AND MM 33- 51-06 AND MM 33-51-07. SYS CHECKD NORMAL.SDR UALA2008111306181Light · improper partOVERHEAD READING LIGHT OVER ROW 26ABC OVERHEATED CAUSING BURNING SMELL IN CABIN. DEADHEADING FLT CREW REMOVED BULB AND SMELL DISSIPATED. REMOVED BULB IS IN COCKPIT. FLT ATTENDANT REPORTED AFT CABIN FWD LAV DOME LIGHT, THAT CAUSED OVERHEAD SMELL AT 26ABC. TSDR 2008UALA06209Light · inoperativeDOOR 4R EMERGENCY LIGHT OUT, OUTSIDE.SDR 2008UALA06197Gcu · malfunctionedLOST RIGHT GENERATOR. FLIGHT DIVERTED. REPLACED GCU. OK FOR SERVICE.
SDR 2008UALA06184Light · shortedDOOR 2R AND PARTS OF AFT CABIN EMERGENCY EXIT LIGHTS ARE ON. REPLACED SHORTED BULB FOR DOOR 2 RIGHT EXTERNAL EMERGENCY LIGHT AND REPLACED INOP BATTERY PACK AT STA LOC 1240 ITEM M10699 REF WDM 33-51-14 PG 1 AND MM 33-51-06 AND MM 33-51-07. SYS CHECKED NORMAL.SDR 2008UALA06181Light · improper partOVERHEAD READING LIGHT ROW 26ABC OVERHEATED CAUSING BURNING SMELL IN CABIN. DEADHEADING FLT CREW REMOVED BULB AND SMELL DISSIPATED. THE REMOVED BULB IS IN COCKPIT, MAINT TO RETRIEVE BULB AND VERIFY PART NUMBER. FLT ATTENDANT REPORTED AFT CABIN FWD LAV DOME SDR 2008UALA06180O-Ring · leakingLIFE RAFT AT AFT LOWERED CEILING PANEL, CYLINDER PRESSURE FAILED. LOW BOTTLE PRESSURE. LEAKING AT GAUGE TO VALVE O-RING. REMOVED & REPLACED O-RING.SDR UALA2008111306178Sensor · faultyDOOR 2R SLIDE ANNUNCIATOR ALWAYS ON EVEN WHEN DOOR NOT ARMED. REPLACED DOOR 2R GIRT BAR SENSOR S10220. OPS CHECKS GOOD.SDR UALA2008111306174Cable · failedLT OVERWING MANUAL BACKUP CABLE FAILS OPS CHECK. REPLACED BACK-UP CABLE. OPS CHECKS GOOD.SDR UALA2008111306173Battery Pack · dischargedDURING EMERG LITE TEST, FOLLOWING BULLNOSE LIGHTS INOP, 4AB, 6AB, 10CD, 13 CD, 14 AB, 15 AB, 20 CD, 21 AB, 23 CD, 27 CD, AND 29 AB. LAMPED ALL LISTED LOCATIONS. ALSO REPLACED BATTERY PACK M10568, OPS CHECKS GOOD. INSTALLED JIFFY SPLICES ALL LOCATIONS. FOUNSDR UALA2008111306177Lock Nut · misalignedDOOR 2L EMERGENCY POWER ASSIST PRESSURE RESERVOIR RED BAND ON EMERGENCY POWER SPRING CYLINDER ALIGNED IMPROPERLY. ADJUSTED CABLE TERMINAL LOCK NUT TO ACHIEVE DIMENSION.SDR 2008UALA06206Structure · damagedBS 500 BETWEEN STR 25L & 26L HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED. REMOVED EXISTING REPAIR & INSTALLED NEW REPAIR PER EVA 72035.SDR 2008UALA06178Sensor · faultyDOOR 2R SLIDE ANNUNCIATOR ALWAYS ON EVEN WHEN DOOR NOT ARMED. REPLACED DOOR 2R GIRT BAR SENSOR S10220. OPS CHECKS GOOD.SDR 2008UALA06177Lock Nut · out of adjustDOOR 2L EMERGENCY POWER ASSIST PRESSURE RESERVOIR RED BAND ON EMERGENCY POWER SPRING CYLINDER ALIGNED PROPERLY. ADJUSTED CABLE TERMINAL LOCK NUT TO ACHIEVE DIMENSION PER FIG 401 A-A OF MM 52-11-33.SDR 2008UALA06176Skin · chafedRIGHT WING INBOARD FORE FLAP OUTBOARD END UPPER SURFACE HAS CHAFED REPAIR. REMOVED DAMAGED REPAIR AND BONDED ON NEW REPAIR REO G12468, REV B.SDR 2008UALA06175Skin · debondedLEFT WING INBOARD FWD FLAP OUTBOARD END UPPER SKIN DISBONDED DOUBLER. REMOVED PREVIOUS REPAIR. BONDED ON NEW DOUBLER REF REO G12468 REV B.SDR 2008UALA06174Skin · damagedLT OVERWING MANUAL BACKUP CABLE FAILS OPS CHECK. CUT OUT DAMAGED SKIN REF SRM 53-00-01 FIG 201. FAB FILLER AND DOUBLER REF BAC DWG 146N3750 AND SRM 53-00-01 FIG 201, AND INSTALLED.SDR 2008UALA06173Light · inoperativeDURING EMERGENCY LIGHT TEST, FOLLOWING BULLNOSE LIGHTS INOP, 4AB, 6AB, 10CD, 13 CD, 14 AB, 15 AB, 20 CD, 21 AB, 23 CD, 27 CD, AND 29 AB. RELAMPED ALL LISTED LOCATIONS. ALSO REPLACED BATTERY PACK M10568, OPS CHECKS GOOD REF MM 33-51-07 AND 33-51-05.SDR 2008UALA06171Switch · faultyINSTALL JIFFY SPLICES ON EMERGENCY EXIT SWITCH, FWD F/A CALL INDICATORS AND DOOR SLIDE LIGHTS. INSTALLED JIFFY SPLICES ALL LOCATIONS PER BOEING SWPM 20-90-14. FOUND SWITCH S10219 BAD, REPLACED PER AND TEST GOOD PER MM 25-66-11. FOUND MID CABIN EMERGENCY TESSDR 2008UALA06154Light · damagedEEL LIGHT FLOOR STRIP AT 13ABC DAMAGED. REINSTALLED LOOSE EEL STRIP AND SECURED EEL COVER, OPS CHECKED OKAY.SDR 2008UALA06151Floorbeam · corrodedCORROSION ON UPPER T-CAP WHERE IT ATTACHES TO RT CUSP AT BS 1640. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED & INSTALLED A NEW SECTION OF T-CAP.SDR 2008UALA06152Skin · damagedFOUND DENT AND GOUGE JUST AFT OF DOOR 2 LEFT, ON LOWER RIGHT CORNER, AT STATION 760, 8.5 INCHES UP OF WATER LINE. LENGTH OF GOUGE IS 2 INCHES LONG AND DENT WIDTH IS 1 INCH WITH A DEPTH OF .062 DEEP. CLEANED AREA, AND SMOOTHED AREA. AREA IS FREE FROM CRACKS SDR 2008UALA06150Video Unit · smokeSMOKE DETECTED AT MID GALLEY LAV. SMOKE COMING OUT OF VIDEO SYSTEM CONTROL UNIT DURING PREFLIGHT. STOPPED WHEN POWER TURNED OFF. REPLACED VIDEO CONTROL UNIT. OP CHECKS OKAY.SDR 2008UALA06149Slide · unserviceableBOTTLE INADEQUATE. OUTSIDE SERVICE STATION MISTAKE. OVERHAUL AND REPACK SLIDE PER CMM.SDR 2008UALA06141Girt Bar · unsecureDOOR 1R WILL NOT ARM. FOUND GIRT BAR OFF DOOR. SECURED GIRT BAR. OPS CHECK GOOD.SDR 2008UALA06140Bracket · obstructedDOOR 1R WILL NOT ARM OR DISARM PROPERLY. CLEANED DEBRIS FROM GIRT BAR BRACKETS. ARMED AND DISARMED NORMAL.SDR 2008UALA06137Splice · corrodedCABIN, BS 365, RBL 5, T-CAP SPLICE CORRODED. MAJOR REPAIR ACCOMPLISHED. REMOVED STRAP SPLICE. FABRICATED & INSTALLED A NEW STRAP SPLICE.SDR 2008UALA06135Splice · corrodedCABIN, BS 365, RBL 30, T-CAP SPLICE CORRODED. MAJOR REPAIR ACCOMPLISHED. REMOVED OLD SPLICE STRAP, FABRICATED & INSTALLED A NEW STRAP SPLICE.SDR 2008UALA06133Mechanism · defectiveDOOR 4R AFTER ARMING SLIDE GRIT BAR FEEL OFF. AFTER REPLACING SHEARED RIVET, REINSTALLED SLIDE. GIRT BAR STILL COMES OFF WHEN OPENING UNARMED DOOR, NEEDS T/S OF GIRT BAR MECHANISM. OPS CHECKS GOOD.SDR 2008UALA06125Cylinder · misalignedDOOR 4L EMERGENCY POWER ASSIST RESERVOIR RED BAND ON EMERGENCY POWER SPRING CYLINDER NOT ALIGNED PROPERLY. ADJUSTED CHECK NUT TO ACHIEVE DIMENSIONS INDICATED ON FIG 401 VIEW A-A PAGE 402. CABLE TRAVEL CHECKED PER MM 52-11-36. CHECKED GOOD.SDR 2008UALA06124Frame · dentedFWD PIT STA 660 FRAME DENTED ABOUT STR 245. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME & INSTALLED DOUBLER REPAIR.SDR 2008UALA06123Frame · dentedFWD CARGO PIT FUSELAGE FRAME AT STA 600 DENTED IN UPPER FLANGE IN AREA BETWEEN STR 23L AND 24R. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE & INSTALLED DOUBLER REPAIR.SDR 2008UALA06122Frame · dentedFWD CARGO PIT FUSELAGE FRAME AT STA 680 IS DENTED IN UPPER FLANGE BETWEEN STR 24L TO 25L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE SECTION OR RIB AND INSTALLED DOUBLER REPAIR.SDR 2008UALA06121Frame · dentedFWD CARGO PIT FUSELAGE FRAME AT STA 660 IS DENTED IN UPPER FLANGE AT STR 24L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION & INSTALLED DOUBLER REPAIR.SDR 2008UALA06084Light · inoperativeDOOR 4 RT EMERGENCY EXIT LIGHT INOP (EXT). LAMPS INOP. RELAMPED EMERGENCY LIGHT, SYS IS NORMAL.SDR 2008UALA06083Light · inoperativeDOOR NR 2 LT AND RT EMERGENCY EXIT LIGHT INOP (EXT). LAMPS INOP. RELAMPED, OPS NORMAL.SDR 2008UALA06076Fitting · dirtyDOOR 4R ESCAPE SLIDE GIRT BAR STILL ENGAGE NOTICED BY CATERING DURING DOOR OPENING. DIRT AND DEBRIS ACCUMULATION UNDER GIRT BAR. CLEANED AND LUBRICATED GIRT BAR FITTINGS. DOOR ARMS/DISARMS NORMALLY.