What was found
FWD CARGO PIT FUSELAGE FRAME AT STA 660 IS DENTED IN UPPER FLANGE AT STR 24L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION & INSTALLED DOUBLER REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.