Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA05871Trigger · faultyRIGHT OVERWING SLIDE FAILS PNEUMATIC DEPLOY. TRIGGER IS FAULTY. REPLACED TRIGGER. OP CHECKS GOOD.SDR 2008UALA05870Slide · out of positionDOOR 2L SLIDE DISLODGED FROM MOUNT. REINSTALLED DOOR 2L SLIDE.SDR 2008UALA05872Frame · dentedAFT PIT STA 1600 FRAME DENTED AT STR 22L TO 23L. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR 2008UALA05852Oil System · leakingFOUND OIL LEAKING FROM BOTTOM OF PNEUMATIC SUPPLY DUCT COMING OFF APU IN APU COMPARTMENT WHILE ACCOMPLISHING SERVICE TIP, APU HOC. NO OTHER OIL LEAKAGE NOTED. REMOVED & REPLACED APU.SDR 2008UALA05808Skid Shoe · damagedLEFT WING, AFT OF NR 3 LEADING EDGE SLAT ON TOP OF WING, A PREVIOUS OVERLAY REPAIR IS PEELING UP. AREA 2 BY 9 INCHES. DAMAGE BETWEEN LEADING EDGE SLAT AND FWD WING SPAR. PREVIOUS HOT BOND REPAIR ON NR 3 L/E SLAT IS SEPARATING. REMOVED DAMAGED MATERIAL FROM SDR 2008UALA05838Housing · crackedELEV ASYM AND STAB TRIM EICAS MESSAGE ON LOWER EICAS ON TAKEOFF, REPEAT GRIPE. FOUND L SAM MODULE BAD, FOUND HOUSING BODY CORRODED AND CRACKED 360 DEGREES AROUND. REPLACED SAM MODULE, REPLACED ELEVATOR ASSYMETRY ACTUATOR, PERFORMED ELEVATOR ASYM TEST 85625 -SDR 2008UALA05822Fitting · corrodedDOOR 4L LWR FWD LOCKING CRACK FITTING CORRODED BEYOND LIMITS. REPLACED THE CRANK FITTING. REPLACED THE CRANK FITTING.SDR 2008UALA05821Rub Strip · crackedDOOR R2 LWR GATE LWR RUB STRIP CRACKED. FOUND CORROSION AND OVERSIZED HOLES FOR STRIP ATTACH. REPLACED GATE.SDR 2008UALA05814Wire · brokenRT OVER WING SLIDE BOTTLE FAILS PRESSURE TEST. FOUND WIRE LEADING TO CONNECTOR DO5542 BROKEN. REPAIRED WIRE. OPS CHECKS GOOD.SDR 2008UALA05812Gauge · leakingAFT CABIN LIFE RAFT COMPT, 1 LIFE RAFT FAILED PRESSURE CHECK. LEAK FOUND AT GAUGE. REMOVED AND REPLACED GAUGE.SDR 2008UALA05811Structure · dentedEXTERNAL FUSELAGE BETWEEN BS 605 AND 625 AND BETWEEN STR 16L AND 17L, PREVIOUS REPAIR DOUBLER IS DENTED. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGED DOUBLER AND INSTALLED SKIN DOUBLER REPAIR.SDR 2008UALA05810Guard · out of positionDOOR 1L CAN BE ARMED WITHOUT MOVING ARMING GUARD. REPOSITIONED THE GUARD TO PREVENT ARMING WITHOUT MOVING GUARD.SDR 2008UALA05798Engine · sparksSEVERAL LARGE SPARKS SHOOTING OUT OF THE APU TAIL PIPE. FOUND INTERNAL TURBINE FAILURE. REPLACED APUSDR 2008UALA05803Lanyard · unsecureDOOR 1R WILL NOT ARM. SECURED LOOSE LANYARD ON SLIDE.SDR 2008UALA05787Light · malfunctionedEMERGENCY EXIT LIGHTS ARE DIM ON THE FLOOR IN FIRST CLASS. REPLACED LIGHT AT MID GALLEY.SDR 2008UALA05782Charger · faultyMAIN BATTERY CHARGER EICAS MESSAGE. REPLACED MAIN BATTERY CHARGER.SDR 2008UALA05781Oxygen Mask · no testCAPTAIN'S O2 MASK DOES NOT TEST OK. REPLACED O2 MASK STOWAGE BOX. TESTS OKAY.SDR 2008UALA05770Idg · vibrationLT GEN DRIVE LIGHT WITH VIBRATION. FLIGHT DIVERTED. REPLACED NR 1 ENGINE IDG. SERVICED IDG. RAN ENGINE. OPS CHECK NORMAL.SDR 2008UALA05776Bypass Valve · leakingFOUND LEADING EDGE BYPASS VALVE (V10059) LEAKING, CRACKED CASTING. CRACK (FATIGUE) IN CASTING. REPLACED LEADING EDGE BYPASS VALVE.SDR 2008UALA05765Light · inoperativeEEL FLOOR STRIP INOP AT FWD AFT LAV. SHORT IN EEL WIRING. REPLACED EEL STRIP. CHECK OK.SDR 2008UALA05764Light · inoperativeEEL FLOOR STRIP INOP AT FRONT OF COACH. EEL DAMAGE. REINSTALLED LIGHT STRIP. CHECKS OKAY.SDR 2008UALA05779Door Frame · damagedR-2 DOOR REQUIRES A REPAIR DOUBLER AT THE UPPER HINGE CUT-OUT OF FRAME. MAJOR REPAIR ACCOMPLISHED, INSTALLED A FRAME DOUBLER REPAIR.SDR 2008UALA05778Lamp · inoperativeNR 2 LT MAIN ENTRY DOOR EXTERIOR EMERGENCY LIGHT INOP. RELAMPED. OPS CHECK GOOD.SDR 2008UALA05775Idg · malfunctionedRIGHT GEN DRIVE LIGHT NOT ILLUMINATED AT GATE. REPLACED IDG, ALL OPS CHECKS NORMAL.SDR 2008UALA05756Valve · faultySPLIT DUCTS AT 30000 RT 10 PSI HIGHER THAN LEFT AT CRUISE THRUST SMALLER SPLIT AT IDLE THRUST. NR 2 HIGH STAGE VALVE WEAK. REPLACED NR 2 HIGH STAGE VALVE. OPS CHECK ON GROUND RUN NORMAL.SDR 2008UALA05741Gasket · failedFOUND LT OFFWING SLIDE INFLATION HOSE GASKET BROKEN. REPLACED INFLATION GASKET.
SDR 2008UALA05730Idg · inoperativeLEFT IDG DRIVE LIGHT ON AFTER TAKEOFF. FOUND DEFECTIVE IDG. REPLACED LEFT ENG IDG. IDG OPS AND LEAK CHECK GOOD. SAFETIED LEFT GENERATOR DISCONNECT SWITCH GUARD. OK FOR SERVICE.SDR 2008UALA05697Floorbeam · corrodedMAIN CABIN T-CAP AT BS 324, RBL 58, IS CORRODED BEYOND LIMITS. *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF T-CAP. FABRICATED & INSTALLED A NEW REPAIR SECTION.SDR 2008UALA05713Lamp · inoperativeDOOR 2L SLIDE ARMING LIGHT INOP. FOUND SLIDE LIGHT INOP. DOOR VERIFIED TO BE ARMED. RELAMPED ARMING LIGHT, CHECKS OKAY.SDR 2008UALA05718Frame · dentedAFT PIT STA 1540 FRAME DENTED AT STR 25L AT INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED FRAME SECTION AND INSTALLED DOUBLER REPAIR.SDR 2008UALA05717Frame · dentedFRAME DENTED AFT PIT BS 1400 STR 26L-25L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR 2008UALA05716Frame · dentedFRAME DENTED AFT PIT BS 1410 AND STR 26L - 25L. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION AND INSTALLED DOUBLER REPAIR.SDR 2008UALA05715Frame · dentedAFT PIT STA 1580, STR 25L, FRAME DENTED INBOARD FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION AND INSTALLED DOUBLER FRAME REPAIR.SDR 2008UALA05714Frame · damagedAFT PIT FRAME AT STA 1520 (LEFT SIDE) IS DENTED AND HAS GOUGES AT LOWER SECTION. MAJOR REPAIR ACCOMPLISHED. REMOVED PRODUCTION SPLICE AND DAMAGED SECTION OF FRAME. INSTALLED DOUBLER REPAIR.SDR 2008UALA05711Shutoff Valve · malfunctionedPRESSURIZATION PROBLEMS. FLIGHT DIVERTED. FOUND RT ENGINE HPSOV FAILED. REPLACED RT HPSOV. OPS AND LEAK CHECKED. NO DISCREPANCIES NOTED. BLEED SHIFT OPS NORMAL.
SDR 2008UALA05683Lamp · inoperativeDOOR 1L ARMED LIGHT INOP. RELAMPED DOOR 1L ARM LIGHT. AFTER RELAMP LIGHT OPERATED NORMALLY.SDR 2008UALA05684Lanyard · unsecureUNABLE TO ARM DOOR 1R. SECURED LANYARD. OPS OKAY.SDR 2008UALA05690O-Ring · blownLOW BOTTLE. O-RING ON FILLER VALVE BLOWN OUT. REMOVED & REPLACED ALL EXTERNAL O-RINGS PER JD.SDR 2008UALA05687Structure · damagedON INBOUND RECEIVING INSPECTION, A TEAR WAS FOUND ON THE NR 6 SLAT, RT INBOARD IN THE UPPER INBOARD CORNER OF THE TRAILIING EDGE WEDGE. THE TEAR GOES FROM THE TRAILING EDGE 3.3 INCHES INTO THE WEDGE. THE TEAR GOES COMPLETELY THROUGH THE WEDGE, BOTH FACES ANDSDR 2008UALA05685Battery · faultyBATTERY CHARGER STATUS MESSAGE WILL NOT ERASE. REPLACED BATTERY. OPS GOOD. NO FAULTS.SDR 2008UALA05675Girt Bar · out of alignmentDOOR 3R ARMING LIGHT WILL NOT ILLUMINATE. FOUND GIRT BAR OUT OF ALIGNMENT. REALIGNED GIRT BAR. OPS CHECKED GOOD.SDR 2008UALA05679Light · brokenEMERGENCY LIGHT STRIP, LAST FEW FEET BROKEN OFF. REPAIRED EMERGENCY LIGHT WIRING AND REPLACED TRACK.
SDR 2008UALA05651Lamp · inoperativeSLIDE LIGHT INOP AT DOOR 2R. LAMP INOPERATIVE. REPLACED LAMP. CHECKED GOOD.SDR 2008UALA05655Transceiver · defectiveLEFT HF DOES NOT TRANSMIT ON 8843. SUSPECT LEFT COUPLER. REPLACED LT TRANSCEIVER. REPLACED LT COUPLER. OPS NORMAL.SDR 2008UALA05652Lamp · inoperativeSLIDE LIGHT INOP AT DOOR 4R. FOUND LAMP INOPERATIVE. REPLACED LAMP. OP CHECKS GOOD.SDR 2008UALA05627Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT AT DOOR NR 4 RT. LIGHT FOUND DEFECTIVE. REPLACED LAMP. OPS CHK GOOD.SDR 2008UALA05626Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT LT NR 1 DOOR. LIGHT FOUND INOP. REPLACED LAMP. OP CKS GOOD.SDR 2008UALA05624Inverter · failedCENTER SECTION BY FWD CTR EMERGENCY EXIT WILL NOT ILLUMINATE DURING TEST, FOUND INVERTER FOR ASSOCIATED AREA COLD. SUSPECT INVERTER FAILURE. REPLACED INVERTER. OPS CHECK GOOD.SDR 2008UALA05625Generator · leakingHMG TEST FAILED WITH ONLY PARTIAL VOLTAGE SHOWING ON EICAS. REPLACED HMG PER MM 24-25- 01. PERFORMED OPERATIONAL TEST AND LEAK CHECK. FOUND HYDRAULIC FLUID LEAKING FROM MAIN BODY PARTING SURFACES. RE-INSTALLED ORIGINAL HMG, OPS CHECK GOOD.SDR 2008UALA05611Lamp · inoperativeNR 4 DOOR LT EMERGENCY EXTERIOR LIGHT INOP. RELAMPED, OPS CHECK GOOD.