SDR 2008UALA02810Slide · unsecureLEFT OVERWING SLIDE PACK FOUND UNLEASHED. REMOVED AND REPLACED OFF WING SLIDE.SDR 2008UALA02779Switch · shortedNR 1 RT GALLEY DOOR SLIDE ARM LIGHT ONLY FUNCTIONS ON DIM. *S/D* GIRT BAR SWITCH HAS ELECTRICAL SHORT. REPLACED GIRT BAR SWITCH IN FWD POSITION, OPS CHECKED GOOD.SDR 2008UALA02776Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED STA 324, RBL 40 TO RBL 54. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW MM 53-00-98 RPR XXV FIG 824.SDR 2008UALA02789Light · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 2L INOP. LAMP INOP. RELAMPED LIGHT AT DOOR 2L.SDR 2008UALA02778Wire · nickedPAX REPORTED RECEIVING A ELECTRIC SHOCK IN MID LAV. FOUND VERY TINY NICK ON DOOR SWITCH WIRE, GROUNDING TO LAV STRUCTURE. REPAIRED WIRE.SDR 2008UALA02766Tank · fullMID LAV FULL PER CREW. FLT DIVERTED. SERVICED LAVS, OPS NORMAL.SDR 2008UALA02713Warning System · activatedLT ENGINE OIL FILTER MSG ON START. FOUND GEARBOX BEARING FAILURE. REPLACED NR 1 ENGINE.SDR 2008UALA02750Light · inoperativeDOOR NR 4R SLIDE LIGHT INOP. RELAMPED. OPS CHECKED OK.SDR 2008UALA02745Unknown · odorSTRONG ODOR LIKE FAILING BEARING IN COCKPIT. CHRONIC WRITE-UP. ACP FULL INSPECTION IAW FI M 21-00-01 SMOKE OR FUMES. RAN ENGINES INDEPENDANTLY WITH PACKS ISOLATED. RAN APU AND PACKS. DID VISUAL OF ALL ASSOCIATED SYSTEM FOR HYD OR OIL LEAKS. NO OBVIOUS LEAKS SDR 2008UALA02709Radar · malfunctionedLOST WEATHER RADAR. FLIGHT DIVERTED. REPLACED WX TRANSCEIVER, INSTLD SVCBL SCANNERSDR 2008UALA02748Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 3L. RELAMPED, OPS GOOD.SDR 2008UALA02746Lamp · inoperativeBOTH 2 AND 3 DOOR EXTERIOR EMERGENCY LIGHTS INOP. RELAMPED, ALL LIGHTS WORK AS NORMAL.SDR 2008UALA02744Switch · faulty"R" LAV SMOKE DETECTOR RESET SWITCH BAD. REPLACED "R" LAV SMOKE DETECTOR., OPS CHECKED GOOD.SDR 2008UALA02724Gate · damagedL-2 DOOR LOWER GATE HAS ELONGATED AND OVERSIZE HOLES FROM RUB STRIP MOUNTING. WELDED LOWER GATE AND INSTALLED RUB STRIP.SDR 2008UALA02723Structure · damagedDOOR 2L UPPER HINGE ARM CUTOUT REQUIRES DOUBLER REPAIR. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE AND INSTALLED DOUBLER REPAIR.SDR 2008UALA02722Structure · crackedDOOR 2R UPPER HINGE ARM CUTOUT CRACKED. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE AND INSTALLED DOUBLER REPAIR.SDR 2008UALA02749Girt Bar · obstructedDOOR 1R WILL NOT ARM. DEBRIS UNDER GIRT BAR. CLEANED DEBRIS, STOWED LANYARD AND DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA02747Light · unsecureEXIT PATH LIGHTING BY SEAT 13C IS PULLING AWAY FROM THE CARPET. SECURED EEL LIGHT COVERSDR 2008UALA02743Slide · low pressureNR 1L DOOR ESCAPE SLIDE BOTTLE PRESSURE LOW. FOUND DURING NR 3 SERVICE. REPLACED SLIDE, TESTS GOOD.SDR 2008UALA02699Idg · failedLEFT IDG RECHECK TOOK MORE THAN 75 PUMPS. IDG ARRIVED WORKING. BPP SHOWS LEFT IDG HIGH TEMP AND HIGH RISE LAST TWO LEGS. FUEL/OIL COOLER FAILURE CONTRIBUTED TO IDG FAILURE. REPLACED IDG AND FUEL/OIL COOLER.SDR 2008UALA02685Control Unit · malfunctionedLOST GALLEY LOAD SHED ON CLIMBOUT. RELATED TO SDR 2008UALA02620. THIS ISSUE WAS VERY DIFFICULT TO DIAGNOSE AND REQUIRED THREE WEEKS OF CONSTANT TROUBLESHOOTING. AFTER ALL WIRES WERE HAND OVER HAND CHECKED AND FOUND NORMAL, K1 AND K2 RELAYS WERE CHANGED, BUSSDR 2008UALA02697Control System · malfunctionedCAN'T CONTROL COCKPIT OR CABIN TEMP WITH OR WITHOUT TRIM AIR EITHER TO HOT OR TO COLD.
SDR 2008UALA02672Strap · out of positionSTRAP HANGING OUT OF SLIDE PACK AT 2L. SECURED D-RING STRAP.SDR 2008UALA02670Wire · shortedINTERPHONE SYSTEM HOT TO FLIGHT DECK FROM ALL THREE FLIGHT ATTENDANT POSITIONS. WIRES SHORTED AT 4251Y-22 AND 4251G-22 AT PARTITION DOOR 1 LEFT HANDSET CONNECTOR D939. REPAIRED AND SOLDERED 4251Y-22 AND 4251G-22 AT PARTITION DOOR 1 LEFT HANDSET CONNECTOR D93SDR 2008UALA02661Frame · dentedAFT PIT STA 1540 STR 26L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE AND INSTALLED "J" ANGLE REPAIR.SDR 2008UALA02660Frame · dentedAFT PIT BS 1400 AT STR 26L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE AND INSTALLED "J" ANGLE REPAIR.SDR 2008UALA02698Relay · failedSPOILERS ONLY PARTIALLY DEPLOYED ON LANDING. RELAY K217 FAILED ELECTRICALLY. REPLACED AUTO SPEEDBRAKE RELAY (EXTEND) K217, OPS CHECKED NORMAL.SDR 2008UALA02684Fitting · looseHYDRAULIC QUANTITY DECREASED TO 47. QUANTITY STABLE WITH PUMPS OFF, CENTER SYSTEM. CREW COMMENTS, C HYD QTY .38 WITH PUMPS ON. SUPPLEMENTAL DATA UPDATE, FOUND C2 PRESS INLET UNION TO FILTER MODULE SPRAYING HYDRAULIC FLUID. SECURED UNION FITTING AND SERVICESDR 2008UALA02683Wire · mislocatedLAV "A" WIRE BURNED AT TOP OF VANITY LIGHT ASSY, HAS CHAFED WIRES, 1 SCREW MISSING FROM ASSY BASE. WIRES MISLOCATED, INSTALLED IMPROPERLY. REPLACED WIRES.SDR 2008UALA02666Shutoff Valve · failedFUEL CONFIG LIGHT ON. IMBALANCE OF 3000 POUNDS BETWEEN LEFT AND RIGHT TANKS WITH BOTH CROSSFEED. SUPPLEMENTAL DATA UPDATE, RT FUELING SHUTOFF VALVE INOP. REPLACED RT FUELING SHUTOFF VALVE, OPS CHECKED NORMAL.SDR 2008UALA02648Slide · out of positionRT OVERWING SLIDE PACK FOUND UNLEASHED. SUPPLEMENTAL DATA UPDATE, UNKNOWN DAMAGE. REPLACED SLIDE PACK.SDR 2008UALA02646Control Unit · intermittentLEADING EDGE FLAP DISAGREE INDICATION. RTFL SFO. FSEU INTERMITTENT FAILURES. REPLACED FSEU NR 3 AND RIGGED PDU TRANSMITTER AND LEFT SLAT TRANSMITTER. OPS CHECKED OK.SDR 2008UALA02652Frame · dentedAFT PIT BS 1620 AT STR 26L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE. INSTALLED 'J' ANGLE REPAIR.SDR 2008UALA02651Frame · dentedAFT PIT BS 1540 AT STR 25R FRAME DENTED. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE. INSTALLED "J" ANGLE REPAIR.SDR 2008UALA02649Frame · damagedFRAME REPAIRED AT BS 580 BETWEEN STR'S 22L AND 23L. MAJOR REPAIR ACCOMPLISHED, INSTALLED NEW FRAME REPAIR.SDR 2008UALA02639Skin · damagedR2 DOOR UPPER HINGE ARM CUT-OUT HAS DAMAGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED: RMV'D DAMAGE. FABRICATED & INSTALLED A REPAIR ANGLE & TAPERED FILLERS.SDR 2008UALA02638Arm · crackedL2 DOOR UPPER HINGE ARM CUTOUT HAS CRACKS. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. FABRICATED & INSTALLED A REPAIR ANGLE & TAPERED FILLERS.SDR 2008UALA02640Door Frame · gougedFUSELAGE DOOR FRAME GOUGED DUE TO LATCH ON ACCESS DOOR 113AL. TRIMMED OUT DAMAGE AND ACP 'D HFEC INSPECTION PER NDT 6-51-00-19, AND FABRICATED A REPAIR A NGLE AND FILLER AND INSTALLED PER REO G12327, REV. B ON NO N ROUTINE 28814. PER EVA 71516,SDR 2008UALA02633Lanyard · unsecureDOOR 4R WILL NOT ARM. FOUND SLIDE LANYARD INTERFERING. SECURED LANYARD, OPS ARMS/DISARMS NORMALLY.SDR 2008UALA02632Door · obstructedDOOR 1L DOES NOT DISARM. FOUND FOD UNDER DOOR. REMOVED SCREW FROM UNDER AFT GATE AREA, DISARMS NORMALLY.
SDR 2008UALA02620Control Unit · failedLOST AFT GALLEY POWER ON CLIMB-OUT. THIS ISSUE WAS VERY DIFFICULT TO DIAGNOSE AND REQUIRED THREE WEEKS OF CONSTANT TROUBLESHOOTING. AFTER ALL WIRES WERE HAND OVER HAND CHECKED AND FOUND NORMAL, K1 AND K2 RELAYS WERE CHANGED, BUSS TIE BREAKERS WERE ALSO CHANGSDR 2008UALA02605Slide · faultyDOOR 4R SLIDE BOTTLE PRESSURE IS ONE NEEDLE WIDTH TO THE LEFT OF THE GREEN BAND. SLIDE BOTTLE PRESSURE IS LOW. AFTER SETTING FOR TWO HRS NEEDLE AT END OF GREEN BAND WITHIN CF LIMITS, SLIDE WAS SCHEDULED TO BE REPLACED.SDR 2008UALA02597Skin · damagedL-2 DOOR UPPER HINGE ARM CUT-OUT IS OUT-OF-TOLERANCE. INSTALLED NEW DOUBLER-L-2 DOOR UPPER HINGE ARM CUT-OUT REQUIRES DOUBLER PER MM 52-11-87, ACCOMPLISHED HFEC INSP AND FOUND .25 " CRACK AT AFT LOWER CORNER.SDR 2008UALA02623Bulb · inoperativeDR 3L SLIDE LIGHT OUT. FOUND INOPERATIVE BULB. REPLACED BULB. OPS CHECKED OK.SDR 2008UALA02611Feeder Cable · damagedBULL NOSE LIGHT AT STA 1370R AND FLOOR LIGHT AT K LAV INOP. FOUND CABLE DAMAGE TO LIGHT ASSY. R EPAIRED LIGHT CABLE ASSY AND RELAMPED. OPS NORMALSDR 2008UALA02609Frame · dentedAFT PIT BS 1500 BETWEEN STRS 26L AND 25L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR 2008UALA02608Frame · dentedAFT PIT BS 1440 BETWEEN STRS 26L AND 25L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR.
SDR 2008UALA02607Frame · dentedAFT PIT BS 1420 BETWEEN STRINGERS 26L AND 25L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR 2008UALA02569Stringer · damagedAFT PIT STA 1400 STR 26L HAS ENLONGATED HOLES IN SIDES OF STRINGERS DUE TO REPLACEMENT STRINGER CLIPS ON FRAME REPAIR. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE, STA 1390 TO 1410. INSTALLED NEW SECTION AND FILLER AND REPAIR SPLICES.SDR 2008UALA02568Stringer · damagedAFT PIT STA 1400 STR 25L HAS ELONGATED HOLES IN SIDES OF STRINGER DUE TO REPLACEMENT STRINGER CLIPS ON FRAME REPAIR. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE. INSTALLED FILLER AND 2 REPAIR SPLICES.