Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA00799Frame · damagedFUSELAGE FRAME AT BS 1600 STR 26L AND BS 1320 STR 28L IS DAMAGED. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00792Lanyard · out of positionAFT RIGHT DOOR WON'T ARM. LANYARD INTERFERENCE. REPOSITIONED LANYARD, DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA00768Sign · looseAFT SIDE OF OVERWING EXIT SIGN IS LOOSE ON THE RIGHT SIDE OF AIRCRAFT. RESECURED EXIT SIGN.SDR 2008UALA00790Circuit Card · faultyAFT CARGO FIRE WARNING SYSTEM INOPERATIVE. INDICATION ISSUE WITH FIRE DET CIRCUIT CARD. REPLACED BOTH FWD AND AFT FIRE DET CIRCUIT CARDS, ACCOMPLISHED ALL CHECKS FOR SYSTEM OPS.SDR 2008UALA00766Gate · corrodedR-1 DOOR LOWER GATE CORRODED AND DAMAGED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED: REPLACED DOOR 1R GATE.SDR 2008UALA00769Lanyard · out of positionDOOR 1R WILL NOT ARM. LANYARD INTERFERENCE. SECURED LANYARD, DOOR ARMS/DISARMS NORMALLY.SDR 2008UALA00767Light · inoperativeLEFT LAMP INOP IN FLT DECK DOOR (LOCK FAIL) INDICATOR. BULB OUT (BURNED OUT). REPLACED BULB, OPS CHECKS OK.SDR 2008UALA00765Structure · damagedR-2 DOOR UPPER HINGE ARM CUTOUT REQUIRES DOUBLER. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00764Structure · damagedL-2 DOOR UPPER HINGE ARM CUTOUT REQUIRES DOUBLER INSTALLATION. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00751Circuit Card · faultyFLIGHT DIVERTED DUE TO AFT CARGO FIRE INDICATION. INDICATION ISSUE WITH CONTROL CARD. REPLACED FIRE DET CIRCUIT CARD M10427 FOR FWD AND AFT CARGO SMOKE DETECTION. ALL OPS CHECKS PERFORMED WERE SATISFACTORY.SDR 2008UALA00780Light · inoperativeEMERGENCY LIGHT AT DOOR 4 RT INOP (EXT). LIGHT BULB VIBRATED LOOSE. SECURED LIGHT BULB AND OPS CHECKED GOOD.SDR 2008UALA00713Switch · faultySTATUS MESSAGE: FLAP ISLN VAL. PTU PRESSURE SWITCH FAULTY. REPLACED PTU PRESSURE SWITCH, OPS AND LEAK CHECKED OK.SDR 2008UALA00699Light · looseEMERGENCY LIGHT AT DOOR 4 RT INOP (EXT). LIGHT BULB VIBRATED LOOSE. SECURED LIGHT BULB AND OPS CHECKED GOOD.SDR 2008UALA00701Gate · corrodedR4 DOOR LOWER GATE SKIN HAS CORROSION. REPLACED LOWER GATE.SDR 2008UALA00700Gate · crackedR-1 DOOR UPPER GATE CRACKED.SDR 2008UALA00686Wire · out of positionDOOR 4L DOOR SLIDE ARM LIGHT DOES NOT COME ON WHEN ARMED, POPS C-B. FOUND WIRES AT GIRT BAR SWITCH CONTACTING GROUND. REPOSITIONED WIRES CORRECTLY, OPS CHECKED OK.SDR 2008UALA00688Structure · crackedR-1 DOOR HANDLE BOX CRACKED AT CAM BASKET HOLES. STRESS CRACK TO HANDLE BOX. REMOVED AND REPLACED HANDLE BOX AT GSO.SDR 2008UALA00687Torque Tube · gougedR-1 DOOR UNDER UPPER HINGE TORQUE TUBE, WEB AND SKIN GOUGED BEYOND SRM LIMITS. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00660Fuel Cell · contaminatedRTFL DUE TO L ENGINE FUEL FILTER MSG. FOUND POSSIBLE MICROBIAL CONTAMINATION ON FILTER. ACCOMPLISHED FUEL CONTAMINATION TEST PER MM28-10-00 ON LT AND RT FUEL TANKS. RT TANK TESTED NEGATIVE -- LT TANK TESTED LOW POSITIVE.SDR 2008UALA00658Pressure Switch · faultyRIGHT HYDRAULIC SYSTEM RESERVOIR LIGHT ILLUMINATED. FOUND PRESSURE SWITCH FAULTY. REPLACED PRESSURE SWITCH, NO REPEATS.SDR 2008UALA00675Idg · faultyTHE L BUSS TIE WILL NOT COME ON-LINE. LT (NR 1 ENG) IDG IS FAILING. REPLACED IDG, ALL TESTS NORMAL.SDR 2008UALA00669Frame · damagedAIRCRAFT RECEIVED DAMAGE TO THE BS 1681 FRAME AT WL 210, NEAR THE THRESHOLD AT DOOR 4R. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00708Control Panel · shortedAFT CARGO FIRE SYS SWITCH LT DOES NOT ILLUMINATE DURING TEST. ASSOC EICAS MSG DOES DISPLAY. CARGO FIRE TEST PANEL SHORT. REPLACED CARGO FIRE TEST PANEL. ALL OPS CHECKS ARE GOOD.SDR 2008UALA00651Light · brokenR-4 DOOR SURROUND PANEL (BLACK) EMERGENCY LIGHT BROKEN. REMOVED AND REPLACED R4 DOOR SLIDE LIGHT.SDR 2008UALA00650Switch · brokenL-4 DOOR SURROUND PANEL, EMERGENCY SWITCH TEST IS BROKEN. FOUND DAMAGE TO EMER LIGHT TEST SWITCH. REPLACED EMER LIGHT TEST SWITCH, OPS CHECKED NORMALLY.
SDR 2008UALA00652Skin · gougedRT INBOARD FLAP VANE UPPER EXTERNAL SURFACE IS GOUGED AT OUTBOARD END OF VANE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00610Lamp · inoperativeSEAT 17C EEL LIGHT OUT. FOUND LAMP BURNED OUT. RELAMPED LIGHT, OPS CHECKED NORMAL.SDR 2008UALA00611Solenoid · failedLEFT MAIN LANDING DOOR WILL NOT CLOSE. LT MLG DOOR CONTROL VALVE SOLENOID FAILED. REPLACED LT MLG DOOR CONTROL VALVE, OPS CHECKED OK.SDR 2008UALA00609Lanyard · misriggedDOOR 4R, DOOR SLIDE WILL NOT FULLY DISARM. FOUND DOOR SLIDE LANYARD WRAPPED IN MECHANISM FOR SLIDE GIRT BAR. STOWED LANYARD PROPERLY, DOOR SLIDE ARM/DISARM NOW WORKS FREELY. NO REPEATS.SDR 2008UALA00592Aspirator · damagedFLAPPER VALVES ON ASPIRATOR LEAKING. FOUND SLIDE WAS DEPLOYED AND COULD BE THE CAUSE OF DAMAGED ASPIRATOR. REPLACED ASPIRATOR, OPS CHECKED NORMAL.SDR 2008UALA00587Oxygen Mask · misinstalledF-O OXYGEN MASK AND SPEAKER ARE INSTALLED IN REVERSE POSITIONS. FOUND TO BE INSTALLATION ERROR (QA). REINSTALLED OXYGEM BOX AND SPEAKER BOX IN CORRECT POSITIONS.SDR 2008UALA00588Oxygen Mask · faultyCREW REPORT: CAPT OXYGEN MASK MIC INOPERATIVE. FOUND ELECTRICAL SHORT IN WIRING IN CAPT O2 MASK MIC. REPLACED CAPT O2 MASK AND MIC ASSY. OPS CHECKED NORMAL.SDR 2008UALA00528Structure · damagedLOWER RUDDER DAMAGED. MAJOR REPAIR ACCOMPLISHED ON A/C.SDR 2008UALA00545Skin · dentedCREW REPORT: A CREASE ON THE LOWER FUSELAGE AFT OF THE AFT GALLEY DRAIN IS ABOUT A FOOT LONG. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00506Frame · dentedAFT PIT FRAME DENTED AT STR 26L STA 1420 ON INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00505Frame Splice · damagedAFT PIT STA 1520 BETWEEN STR 24R AND 25R FRAME SPLICE HAS TOOL MARKS. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00521Light · inoperativeLEFT AFT OVERWING EMERGENCY LIGHT INOP AND LENS CRACKED RIGHT AFT OVERWING EMERGENCY LIGHT INOP ALSO. REPLACED BOTH BULBS AND REPLACED LIGHT ASSY.SDR 2008UALA00503Bearing · failedFOUND METAL ON MASTER CHIP AND GEARBOX CHIP DETECTORS. FOUND BEARING FAILURE. REPLACED ENGINE.
SDR 2008UALA00498Knob · brokenOBSERVERS O2 MASK EMERGENCY KNOB BROKEN. REPLACED OBS O2 MASK ASSY.
SDR 2008UALA00557O-Ring · out of positionDR 1R NO ARM AT DEPARTURE. FOUND O-RING IN THE WAY OF ARMING LEVER. REPOSITIONED O-RING, ARMS/DISARMS OK.SDR 2008UALA00502Gearbox · making metalL ENG PRI CONT EICAS MSG DISPLAYED AND NO IND SEC TOOK OVER. INTERNAL GEARBOX FAILURE INDICATED BY LARGE CHUNKS OF METAL ON CHIP DETECTORS.SDR 2008UALA00475Switch · faultyCARGO FIRE (RED AFT) ARM SW LIGHT INOPERATIVE. REPLACED SWITCH ASSY.SDR 2008UALA00474Gate · damagedL1 DOOR LOWER GATE HAS HOLE IN INSIDE LIP. INSTALLED FILL WELD REPAIR.SDR 2008UALA00472Feeder Cable · damagedEEL LIGHTING POWER FEED CABLE BURNT AND ARCHING AT ROW 18. EEL LIGHTS INTERMITTENT, 8 FOOT SECTION. REPLACED POWER FEEDER CABLE.SDR 2008UALA00471Screw · missingEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 4R. REPLACED MISSING SCREWS. OPS CHECKS GOOD.SDR 2008UALA00470Light · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 2L. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00476Bottle · low pressureTHE 1L DOOR ASSIST BOTTLE NOT IN GREEN BAND. REPLACED DOOR ASSIST BOTTLE 1L DUE TO CHRONIC LEAKING.SDR 2008UALA00473Girt Bar · out of adjustDOOR R1 FAILS MIDWAY CHECK. FOUND GRIT BAR OUT OF ADJUSTMENT. ADJUSTED GIRT BAR. CHECKS NORAMALLY.SDR 2008UALA00455Doubler · corrodedAFT CARGO COMP ANTENNA DOUBLER FWD LT FASTENER NUT PLATE HAS EXFOLIATION CORROSION. REMOVED CHANNEL ASSY. FABRICATED & INSTALLED NEW RADIUS FILLER. MAJOR REPAIR.SDR 2008UALA00454Arm · damagedL-2 DOOR UPPER HINGE ARM CUT OUT IS DAMAGED. ACCOMPLISHED MAJOR REPAIR AT GSO.
Back to Boeing 757-222